Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.3 LAccepted-AOC RAHAM TANDWA DISTT CHATRA PIN 825321 | CHATRA | JHARKHAND | 825321 | ₹2.3 L Quoted ₹2.0 L | L-1 | Accepted-AOC As per recommendation of TC and Approval of Competent Authority |
| 2 | L-2₹2.3 LRejected-Finance DAKRA COLLIERY PO DAKRA CHURI RANCHI NEAR GURUDWARA GM OFFICE ROAD RANCHI HAZARIBAG JHARKHAND 829210 UDYAM JH 20 0002793 | RANCHI | JHARKHAND | 829210 | ₹2.3 L | L-2 | Rejected-Finance As per recommendation of TC and Approval of Competent Authority |
| 3 | Rejected-Technical ARA P O GANESHPUR DIST LATEHAR PIN 829202 | LATEHAR | JHARKHAND | 829202 | - | - | Rejected-Technical As Per NIT |
| Sl No | Description | Qty | Unit | MAA VAISHANVI CONSTRUCTION AND CO L2 | M/S HEMANT KUMAR YADAV L1 |
|---|---|---|---|---|---|
| 1.00 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,4 pole | 5 | nos | 7,123 ₹35,615 | 6,975.9 ₹34,879.50 |
| 2.00 | Supplying and fixing of following ways surface recess mounting, vertical type, 415 V,TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs(but without MCBs and incomer)as required. (Note: Vertical type MOB TPDB Is normally used where 3 phase outlets are required.) | 1 | nos | 12,100 ₹12,100 | 11,577.51 ₹11,577.51 |
| 3.00 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 А, 16 КА, ТРМССВ | 1 | nos | 3,321 ₹3,321 | 3,394.8 ₹3,394.80 |
| 4.00 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door | 1 | nos | 2,159.98 ₹2,159.98 | 1,943.73 ₹1,943.73 |
| 5.00 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. as required.Group A | 22 | Point | 1,350 ₹29,700 | 818.68 ₹18,010.96 |
| 6.00 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch,connections, painting etc. as required | 14 | nos | 315.6 ₹4,418.40 | 293.94 ₹4,115.16 |
| 7.00 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 5 15/16 A Socket Outlet and 15/16 A piano type | 4 | Nos | 580 ₹2,320 | 411.93 ₹1,647.72 |
| 8.00 | Wiring for circuit/submain wiring alongwith earth wire with the 2 x 1.6 sn. mm + 1 X 1.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | 100 | Mtr | 190.6 ₹19,060 | 196.65 ₹19,665 |
| 9.00 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit | 20 | Mtr | 397 ₹7,940 | 288.76 ₹5,775.20 |
| 10.00 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker single pole and neutral for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required | 4 | pcs | 700 ₹2,800 | 533 ₹2,132 |
Tender Value
₹2.2 L
EMD Value
₹2,790
Closing Date
26 May 2025, 5:00 pmClosed
Staff Officer (EnM),Magadh -Sanghmitra Area
Office of The General Manager M-S Area
Controlling the power switching arrangement of 05 shelters kept in the premises of the project office from the coal sampling office and the extension of the JBVNL power supply arrangement for AC in the transient camp of Avantika room numbers (111, 11
2025_CCL_335273_1
GM(MS)/SO(EnM)/e-NIT/25-26/11
Open Tender
Electrical and Maintenance Works
10 days
Office Of the Project Officer Magadh OCP, M-S Area
Please Refer NIT
4 documents required · 4 mandatory
₹2,790
31 Dec 2025
15 May 2025
27 May 2025
16 May 2025
26 May 2025
16 May 2025
16 May 2025 - 23 May 2025
Amount
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,4 pole
Supplying and fixing of following ways surface recess mounting, vertical type, 415 V,TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs(but without MCBs and incomer)as required. (Note: Vertical type MOB TPDB Is normally used where 3 phase outlets are required.)
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 А, 16 КА, ТРМССВ
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. as required.Group A
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch,connections, painting etc. as required
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 5 15/16 A Socket Outlet and 15/16 A piano type
Wiring for circuit/submain wiring alongwith earth wire with the 2 x 1.6 sn. mm + 1 X 1.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker single pole and neutral for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door
Providing of 25 sq mm 4 core isi marked, upto 1.1 kv grade Alluminium armoured cable for portable shelters service wire.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of size not exceeding 35 sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. As required
Providing of 16 sq mm 4 coreisi marked, upto 1.1 kv grade Alluminium armoured cable for AC input power.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of size not exceeding 35 sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. As required
Earthing with copper earth plate 600 mm X 600 mm X 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/coke and salt as required.
Supply of wall mounted fan 400 mm
Fixing Charge of supplied items no 17 at 15% of item cost
Total impact of GST for the purpose of CTC
MAA VAISHANVI CONSTRUCTION AND CO (BID ID -1154811)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid