Tender Value
Refer Docs
EMD Value
₹10 L
Closing Date
1 Feb 2022, 10:00 amClosed
CE D and R
CE D and R Office
Supply of materials for new DT S/S, 33KV, 11KV and LT Lines under DDUGJY-NEW scheme for electrification of Balance UE-HHs in Nagaland
2022_DP_427_2
CEL/DR/D2/UE-HHs/PKG-A
Open Tender
Electrical Works
Item Wise
30 days
Nagaland
Refer tender Doc
3 documents required · 3 mandatory
₹10,000
Chief Engineer D and R
₹10 L
Yes
1 Feb 2022
31 Jan 2022
1 Feb 2022
31 Jan 2022
1 Feb 2022
31 Jan 2022
Amount
Supply of Materials for new 33 KV lines
GI MS Channel 100x50x6mm for top Cross Arm - 2.2 M Long weighing 20.24 kg each
GI M.S Angle 50x50x6x5000 mm each weighing 22.5 Kg (for DP Bracing - 5 nos and SP cross arm bracket 2.5m each - 5 nos) (Galvanised)
33 kV Polymer Disc insulator (70KN)
33 KV Polymer Pin insulator alonwith GI Pin
Supply of Materials for new 11KV lines
GI MS Channel 100x50x6mm for top Cross Arm - 2.2 M Long weighing 20.24 kg each
GI Angle 50X50X6x2500mm each weighing 11.25Kg (for guard bracket- 5 Nos and for SP Cross Arm Brackets -5 nos)
GI M.S Angle 50X50X6X5000 mm each weighing 22.5Kg for DP Bracing
11 kV Polymer Disc insulator 70 KN
11 KV polymer pin insulator
Supply of Materials for construction of 11/0.4 KV, 25 KVA DT Sub-Stations
25 KVA, 11/0,4 KV Transformer (CU Wound) floor mounted
GI Channel 100x50x6 mm for X arm, switch D.O. etc. (2.2 Mtrs length weighing 20.24 Kg each))
M.S. Angle 50x50x6 mm for DT LT Bus Bar (2.2 mtr weighing 10 Kg each)
Lightning arrestor, (9KV, 10KA, 1Ph).
11 KV GO air break switch complete 3-ph (heavy duty)
11 KV D.O. fuse with operating rod (heavy duty)
11 KV polymer pin insulator complete with GI Pin
11 kV Polymer Disc insulator 70 KN
LT XLPE Single Core Aluminium Conductor Power Cable (for DT terminal to LT Bus Bar and LT Bus bar to feeder Pole)
i). 70 Sqmm (AL) ( DT Terminal to LT Bus)
ii) 25 Sqmm (AL) (for Bus to line 1 CKt)
iii). 25 Sqmm (AL) (for Neutral)
Copper Tubular Terminal ends/Lugs heavy duty (for DTs only)
ii) 70 Sqmm
ii) 25 Sqmm
Kit Kat for LT Feeder
i). 30 Amp (for DT protection)
ii) 25 Amp (Feeder protection)
Supply of materials for construction of 11/0.4 KV, 63 KVA DT Sub-Station
63 KVA, 11/0,4 KV Transformer (CU Wound) floor mounted
GI Channel 100x50x6 mm for X arm, switch D.O. etc. (2.2 Mtrs length weighing 20.24 Kg each))
M.S. Angle 50x50x6 mm for DT LT Bus Bar (2.2 mtr weighing 10 Kg each)
Lightning arrestor, (9KV, 10KA, 1Ph).
11 KV GO air break switch complete 3-ph (heavy duty)
11 KV D.O. fuse with operating rod (heavy duty)
11 KV polymer pin insulator complete with GI Pin
11 kV Polymer Disc insulator 70 KN
LT XLPE Single Core Aluminium Conductor Power Cable
i). 95 Sqmm (AL) ( DT Terminal to LT Bus)
ii) 70 Sqmm (AL) (for Bus to line 2 CKt)
iii). 25 Sqmm (AL) (for Neutral)
Copper Tubular Terminal ends/Lugs heavy duty (for DTs only)
i) 95 Sqmm
ii) 70 Sqmm
iii) 25 Sqmm
Kit Kat for LT Feeder
i). 85 Amp (for DT protection)
ii) 63 Amp (Feeder protection)
Supply of materials for construction of 11/0.4 KV, 100 KVA DT Sub-Station
100 KVA, 11/0,4 KV Transformer (CU Wound) floor mounted
GI Channel 100x50x6 mm for X arm, switch D.O. etc. (2.2 Mtrs length weighing 20.24 Kg each))
M.S. Angle 50x50x6 mm for DT LT Bus Bar (2.2 mtr weighing 10 Kg each)
Lightning arrestor, (9KV, 10KA, 1Ph).
11 KV GO air break switch complete 3-ph (heavy duty)
11 KV D.O. fuse with operating rod (heavy duty)
11 KV polymer pin insulator complete with GI Pin
11 kV Polymer Disc insulator 70 KN
LT XLPE Single Core Aluminium Conductor Power Cable
i). 120 Sqmm (AL) ( DT Terminal to LT Bus)
ii) 95 Sqmm (AL) (for Bus to line 2 CKt)
iii). 70 Sqmm (AL) (for Neutral)
Copper Tubular Terminal ends/Lugs heavy duty (for DTs only)
i) 120 Sqmm
ii) 95 Sqmm
iii) 70 Sqmm
Kit Kat for LT Feeder
i). 140 Amp (for DT protection)
ii) 70 Amp (Feeder protection)
Supply of materials for construction of 33/0.4 KV, 25 KVA DT Sub-Stations
25 KVA, 33/0.4 KV Transformer (CU Wound) floor mounted
GI Channel 100x50x6 mm for X arm, switch D.O. etc. (2.2 Mtrs length weighing 20.24 Kg each))
M.S. Angle 50x50x6 mm for DT LT Bus Bar (2.2 mtr weighing 10 Kg each)
Lightning arrestor, (9KV, 10KA, 1Ph).
33 KV GO air break switch complete 3-ph (heavy duty)
33 KV D.O. fuse with operating rod (heavy duty)
33 KV polymer pin insulator complete with GI Pin
33 kV Polymer Disc insulator 70 KN (DP-42Nos, SP-84Nos)
LT XLPE Single Core Aluminium Conductor Power Cable (for DT terminal to LT Bus Bar and LT Bus bar to feeder Pole)
i)70 Sqmm (AL) ( DT Terminal to LT Bus)
ii) 25 Sqmm (AL) (for Bus to line 1 CKt)
iii)25 Sqmm (AL) (for Neutral)
Copper Tubular Terminal ends/Lugs heavy duty (for DTs only)
ii) 70 Sqmm
ii) 25 Sqmm
Kit Kat for LT Feeder
i) 30 Amp (for DT protection)
ii) 25 Amp (Feeder protection)
Supply of materials for construction of 33/0.4 KV, 63 KVA DT Sub-Station
63 KVA, 33/0.4 KV Transformer (CU Wound) floor mounted
GI Channel 100x50x6 mm for X arm, switch D.O. etc. (2.2 Mtrs length weighing 20.24 Kg each))
M.S. Angle 50x50x6 mm for DT LT Bus Bar (2.2 mtr weighing 10 Kg each)
Lightning arrestor, (9KV, 10KA, 1Ph).
33 KV GO air break switch complete 3-ph (heavy duty)
33 KV D.O. fuse with operating rod (heavy duty)
33 KV polymer pin insulator complete with GI Pin
33 kV Polymer Disc insulator 70 KN (DP-42Nos, SP-84Nos)
LT XLPE Single Core Aluminium Conductor Power Cable
i). 95 Sqmm (AL) ( DT Terminal to LT Bus)
ii) 70 Sqmm (AL) (for Bus to line 2 CKt)
iii). 25 Sqmm (AL) (for Neutral)
Copper Tubular Terminal ends/Lugs heavy duty (for DTs only)
i) 95 Sqmm
ii) 70 Sqmm
iii) 25 Sqmm
Kit Kat for LT Feeder
i). 85 Amp (for DT protection)
ii) 63 Amp (Feeder protection)
Supply of Materials for New LT lines
GI LT Angle cross arm (40x40x5x1500 mm) wiighing 5.25 Kg each
LT Pin Insulator (Porcelain) with G.I Pin
Shackel Insulator (Porcelain)
Description of Work / Item(s)
Amount
Supply of Materials for new 33 KV lines
GI MS Channel 100x50x6mm for top Cross Arm - 2.2 M Long weighing 20.24 kg each
GI M.S Angle 50x50x6x5000 mm each weighing 22.5 Kg (for DP Bracing - 5 nos and SP cross arm bracket 2.5m each - 5 nos) (Galvanised)
33 kV Polymer Disc insulator (70KN)
33 KV Polymer Pin insulator alonwith GI Pin
Supply of Materials for new 11KV lines
GI MS Channel 100x50x6mm for top Cross Arm - 2.2 M Long weighing 20.24 kg each
GI Angle 50X50X6x2500mm each weighing 11.25Kg (for guard bracket- 5 Nos and for SP Cross Arm Brackets -5 nos)
GI M.S Angle 50X50X6X5000 mm each weighing 22.5Kg for DP Bracing
11 kV Polymer Disc insulator 70 KN
11 KV polymer pin insulator
Supply of Materials for construction of 11/0.4 KV, 25 KVA DT Sub-Stations
25 KVA, 11/0,4 KV Transformer (CU Wound) floor mounted
GI Channel 100x50x6 mm for X arm, switch D.O. etc. (2.2 Mtrs length weighing 20.24 Kg each))
M.S. Angle 50x50x6 mm for DT LT Bus Bar (2.2 mtr weighing 10 Kg each)
Lightning arrestor, (9KV, 10KA, 1Ph).
11 KV GO air break switch complete 3-ph (heavy duty)
11 KV D.O. fuse with operating rod (heavy duty)
11 KV polymer pin insulator complete with GI Pin
11 kV Polymer Disc insulator 70 KN
LT XLPE Single Core Aluminium Conductor Power Cable (for DT terminal to LT Bus Bar and LT Bus bar to feeder Pole)
i). 70 Sqmm (AL) ( DT Terminal to LT Bus)
ii) 25 Sqmm (AL) (for Bus to line 1 CKt)
iii). 25 Sqmm (AL) (for Neutral)
Copper Tubular Terminal ends/Lugs heavy duty (for DTs only)
ii) 70 Sqmm
ii) 25 Sqmm
Kit Kat for LT Feeder
i). 30 Amp (for DT protection)
ii) 25 Amp (Feeder protection)
Supply of materials for construction of 11/0.4 KV, 63 KVA DT Sub-Station
63 KVA, 11/0,4 KV Transformer (CU Wound) floor mounted
GI Channel 100x50x6 mm for X arm, switch D.O. etc. (2.2 Mtrs length weighing 20.24 Kg each))
M.S. Angle 50x50x6 mm for DT LT Bus Bar (2.2 mtr weighing 10 Kg each)
Lightning arrestor, (9KV, 10KA, 1Ph).
11 KV GO air break switch complete 3-ph (heavy duty)
11 KV D.O. fuse with operating rod (heavy duty)
11 KV polymer pin insulator complete with GI Pin
11 kV Polymer Disc insulator 70 KN
LT XLPE Single Core Aluminium Conductor Power Cable
i). 95 Sqmm (AL) ( DT Terminal to LT Bus)
ii) 70 Sqmm (AL) (for Bus to line 2 CKt)
iii). 25 Sqmm (AL) (for Neutral)
Copper Tubular Terminal ends/Lugs heavy duty (for DTs only)
i) 95 Sqmm
ii) 70 Sqmm
iii) 25 Sqmm
Kit Kat for LT Feeder
i). 85 Amp (for DT protection)
ii) 63 Amp (Feeder protection)
Supply of materials for construction of 11/0.4 KV, 100 KVA DT Sub-Station
100 KVA, 11/0,4 KV Transformer (CU Wound) floor mounted
GI Channel 100x50x6 mm for X arm, switch D.O. etc. (2.2 Mtrs length weighing 20.24 Kg each))
M.S. Angle 50x50x6 mm for DT LT Bus Bar (2.2 mtr weighing 10 Kg each)
Lightning arrestor, (9KV, 10KA, 1Ph).
11 KV GO air break switch complete 3-ph (heavy duty)
11 KV D.O. fuse with operating rod (heavy duty)
11 KV polymer pin insulator complete with GI Pin
11 kV Polymer Disc insulator 70 KN
LT XLPE Single Core Aluminium Conductor Power Cable
i). 120 Sqmm (AL) ( DT Terminal to LT Bus)
ii) 95 Sqmm (AL) (for Bus to line 2 CKt)
iii). 70 Sqmm (AL) (for Neutral)
Copper Tubular Terminal ends/Lugs heavy duty (for DTs only)
i) 120 Sqmm
ii) 95 Sqmm
iii) 70 Sqmm
Kit Kat for LT Feeder
i). 140 Amp (for DT protection)
ii) 70 Amp (Feeder protection)
Supply of materials for construction of 33/0.4 KV, 25 KVA DT Sub-Stations
25 KVA, 33/0.4 KV Transformer (CU Wound) floor mounted
GI Channel 100x50x6 mm for X arm, switch D.O. etc. (2.2 Mtrs length weighing 20.24 Kg each))
M.S. Angle 50x50x6 mm for DT LT Bus Bar (2.2 mtr weighing 10 Kg each)
Lightning arrestor, (9KV, 10KA, 1Ph).
33 KV GO air break switch complete 3-ph (heavy duty)
33 KV D.O. fuse with operating rod (heavy duty)
33 KV polymer pin insulator complete with GI Pin
33 kV Polymer Disc insulator 70 KN (DP-42Nos, SP-84Nos)
LT XLPE Single Core Aluminium Conductor Power Cable (for DT terminal to LT Bus Bar and LT Bus bar to feeder Pole)
i)70 Sqmm (AL) ( DT Terminal to LT Bus)
ii) 25 Sqmm (AL) (for Bus to line 1 CKt)
iii)25 Sqmm (AL) (for Neutral)
Copper Tubular Terminal ends/Lugs heavy duty (for DTs only)
ii) 70 Sqmm
ii) 25 Sqmm
Kit Kat for LT Feeder
i) 30 Amp (for DT protection)
ii) 25 Amp (Feeder protection)
Supply of materials for construction of 33/0.4 KV, 63 KVA DT Sub-Station
63 KVA, 33/0.4 KV Transformer (CU Wound) floor mounted
GI Channel 100x50x6 mm for X arm, switch D.O. etc. (2.2 Mtrs length weighing 20.24 Kg each))
M.S. Angle 50x50x6 mm for DT LT Bus Bar (2.2 mtr weighing 10 Kg each)
Lightning arrestor, (9KV, 10KA, 1Ph).
33 KV GO air break switch complete 3-ph (heavy duty)
33 KV D.O. fuse with operating rod (heavy duty)
33 KV polymer pin insulator complete with GI Pin
33 kV Polymer Disc insulator 70 KN (DP-42Nos, SP-84Nos)
LT XLPE Single Core Aluminium Conductor Power Cable
i). 95 Sqmm (AL) ( DT Terminal to LT Bus)
ii) 70 Sqmm (AL) (for Bus to line 2 CKt)
iii). 25 Sqmm (AL) (for Neutral)
Copper Tubular Terminal ends/Lugs heavy duty (for DTs only)
i) 95 Sqmm
ii) 70 Sqmm
iii) 25 Sqmm
Kit Kat for LT Feeder
i). 85 Amp (for DT protection)
ii) 63 Amp (Feeder protection)
Supply of Materials for New LT lines
GI LT Angle cross arm (40x40x5x1500 mm) wiighing 5.25 Kg each
LT Pin Insulator (Porcelain) with G.I Pin
Shackel Insulator (Porcelain)
Description of Work / Item(s)
Amount
TAXES & DUTIES APPLICABLE ON EQUIPMENTS & MATERIALS
Description of Work / Item(s)
Amount
TOTAL SCHEDULE NO. 1
Ex-works supply of materials
TOTAL SCHEDULE NO. 2
Local Transportation, Insurance and other Incidental Services
TOTAL SCHEDULE NO. 3
Taxes and Duties
M/s Mecavo Power Works
NATIONAL POWER SYSTEMS
NATIONAL POWER SYSTEMS
NATIONAL POWER SYSTEMS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .