Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.8 LAccepted-Finance | ₹71.8 L | L1 | Accepted-Finance L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| Sl No | Description | Qty | Unit | SALIEABS SOLUTIONS LLP L1 |
|---|---|---|---|---|
| 1.00SOLAR PLANT | ||||
| 1.10 | On Grid Solar PV Plant comprising of: i) Solar panels of type Mono Crystline, PERC, etc.ii) Power Conditioning Unit (PCU)with MPPT, Inverter, Controls, Protection Devices, Interconnecting D.C. cables, Connectors, Junction Boxes and accessories. iii) D.C. D.Biv) A.C. D.B v) A.C. cables and accessoriesvi) Lightning arrestor, earthing, etc. vii) Module Metallic Mounting Structuresviii) Installation, Testing and Commissioning corresponds to BIS and IEC requirements | 4 | Kwp | 60,075 ₹2,40,300 Lowest |
| 1.20Supply and delivery of floor mounted type FCMA Air/ Oil Cooled soft starter suitable for the LTmotor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable fornext standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button. | ||||
| 1.30 | 40HP | 1 | No | 3,68,125 ₹3,68,125 Lowest |
| 1.40 | Supply and fixing of the Blower with the capacity of 1034m3/h with 0.5 kg pressure and 3ph 415V 40 HP Induction motor . | 1 | No | 7,16,400 ₹7,16,400 Lowest |
| 1.50CLARIFIER | ||||
| 1.60 | Clarifier mechanism - Service Centrally driven clarifier mechanism to suit tank size of 24.0 m dia x 3.0 m SWD, 3.2 m TD, 5 HP motor with suitable reduction gear box with 1.0 m ht, handrail, Recondtioning of Scrapper rake arms by Welding and Griding of Arms, Gear box shall be worm reduction, foot mounted.filling of oil and rerection. | 1 | No | 3,73,500 ₹3,73,500 Lowest |
| 1.70DECANT RECEVING TANK | ||||
| 1.80Supply and delivery of submersible centrifugal sewage non-clog pumps, vertical spindle type pump , wear resistance with submersible motor for the various duty conditions. Pump shall be capable of handling min 100 mm solid size with sewage specific gravity of up to 1.05. Pump shall be of robust construction, Liquid passages shall be finished smooth and designed as to allow free passage to solids. Pump Impeller should be of Non-clog semi open type , single vane / multi vane preferably contra bloc or vortex impeller design. Double mechanical seal with silicon carbide faces should be provided to protect the motor from ingress of sewage along the shaft. The critical speed of the rotor shall be at least 30% above the operating speed. Pumps should have double bearings between the pump & motor. The bearings life shall be minimum 100,000 hrs of operation with greased for life. Pump should be provided with automatic coupling device including pedestal, duck foot bend, stainless steel guide pipe or related accessories of suitable size to facilitate lifting and lowering into guide rails for easy maintenance. Pump shall be provided with a stainless steel lifting chain conforming to BS 970 Gr 304. Pump speed shall be of 9600 rpm for high duty pumps and 960/1450 rpm for low duty pumpsets. Casing and impeller should be of CI Gr. FG 260:IS210 more preferably with hardened impeller.Shaft should be of stainless steel AISI 410. All the fasteners and bolts shall be of AISI 410.The submersible motor shall be operated with 3ph, 415 V(+or– 10%), 50Hz(+or-5 %) dry induction type. Motor shall be capable of giving rated output without reduction in the expected life span when operated continuously. The rotating assembly shall be dynamically balanced as per standards. The starting current of the motor shall not exceed 200% of rated full load current for Star / Delta or ATS starting under any circumstances .The motor shall be suitable for full voltage star delta / ATS starting. The locked rotor current of the motor shall not exceed 600% of full load current unless otherwise specified. Motor shall be designed to withstand 120% of rated speed for two minutes without any mechanical damage, in either direction of rotation. The motor vibration shall be within the limit specified in applicable standards . Motor should be of IE2, explosion proof compatible for VFD operation together with star-Delta /ATS starter, protection against increase in stator winding temperature (15 deg Celsius), bearing temperature, leakage in the stator housing and terminal box shall be provided and to be suitably interlocked with the control panel for tripping the pump in case of increase in temperature beyond set limit. Insulation class shall be of “Class H” and degree of protection shall be of IP 68 as per IS 4691. Motor shall be suitable for continuous operation in fully submerged or partially submerged condition.The pumpset shall be supplied with power cable of PVC insulated and PVC sheathed, copper, flexible, round type with required conductor size and number of cores as per starting method and of specified length for continuous use under water and air. The control cable of PVC insulated, PVC sheathed, flexible for stator winding temperature sensor 3core x 1.5 sq.mm copper conductor and for bimetallic switches 2core x 1.5 sqmm copper conductor shall be provided. Motor shall be supplied with 10m of round submersible copper cable of suitable size. The non clog submersible pumpset shall be provided with suitable starter control panel having all protections as mentioned above. (upto 5 HP - DOL Starter, above 5 HP to 25 HP -Star Delta Panel and beyond 25 HP shall be ATS) | ||||
| 1.90 | Discharge upto 610 M3/hour | 1 | No | 17,13,722 ₹17,13,722 Lowest |
Tender Value
₹95 L
EMD Value
₹95,000
Closing Date
18 Mar 2026, 3:00 pmClosed
THE COMMISSIONER, SALEM CITY MUNICIPAL CORPORATION
Salem City Municipal Corporation, Fort Main Road, Salem.
Improvement Works to 13 MLD Vellakuttai STP in Salem Coperation.
2026_MAWS_673139_1
SS1-EST-NO-427-2025-2026
Open Tender
Civil Works
Lump-sum
90 days
Salem City Municipal Corporation
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹95,000
Salem City Municipal Corporation
29 Jun 2026
11 Mar 2026
18 Mar 2026
11 Mar 2026
18 Mar 2026
11 Mar 2026
13 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SOLAR PLANT | |||||
| 1.1 | On Grid Solar PV Plant comprising of: i) Solar panels of type Mono Crystline, PERC, etc.ii) Power Conditioning Unit (PCU)with MPPT, Inverter, Controls, Protection Devices, Interconnecting D.C. cables, Connectors, Junction Boxes and accessories. iii) D.C. D.Biv) A.C. D.B v) A.C. cables and accessoriesvi) Lightning arrestor, earthing, etc. vii) Module Metallic Mounting Structuresviii) Installation, Testing and Commissioning corresponds to BIS and IEC requirements | 4 | Kwp | - | - |
| 1.2 | Supply and delivery of floor mounted type FCMA Air/ Oil Cooled soft starter suitable for the LTmotor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable fornext standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button. | - | - | - | - |
| 1.3 | 40HP | 1 | No | - | - |
| 1.4 | Supply and fixing of the Blower with the capacity of 1034m3/h with 0.5 kg pressure and 3ph 415V 40 HP Induction motor . | 1 | No | - | - |
| 1.5 | CLARIFIER | - | - | - | - |
| 1.6 | Clarifier mechanism - Service Centrally driven clarifier mechanism to suit tank size of 24.0 m dia x 3.0 m SWD, 3.2 m TD, 5 HP motor with suitable reduction gear box with 1.0 m ht, handrail, Recondtioning of Scrapper rake arms by Welding and Griding of Arms, Gear box shall be worm reduction, foot mounted.filling of oil and rerection. | 1 | No | - | - |
| 1.7 | DECANT RECEVING TANK | - | - | - | - |
| 1.8 | Supply and delivery of submersible centrifugal sewage non-clog pumps, vertical spindle type pump , wear resistance with submersible motor for the various duty conditions. Pump shall be capable of handling min 100 mm solid size with sewage specific gravity of up to 1.05. Pump shall be of robust construction, Liquid passages shall be finished smooth and designed as to allow free passage to solids. Pump Impeller should be of Non-clog semi open type , single vane / multi vane preferably contra bloc or vortex impeller design. Double mechanical seal with silicon carbide faces should be provided to protect the motor from ingress of sewage along the shaft. The critical speed of the rotor shall be at least 30% above the operating speed. Pumps should have double bearings between the pump & motor. The bearings life shall be minimum 100,000 hrs of operation with greased for life. Pump should be provided with automatic coupling device including pedestal, duck foot bend, stainless steel guide pipe or related accessories of suitable size to facilitate lifting and lowering into guide rails for easy maintenance. Pump shall be provided with a stainless steel lifting chain conforming to BS 970 Gr 304. Pump speed shall be of 9600 rpm for high duty pumps and 960/1450 rpm for low duty pumpsets. Casing and impeller should be of CI Gr. FG 260:IS210 more preferably with hardened impeller.Shaft should
be of stainless steel AISI 410. All the fasteners and bolts shall be of AISI 410.The submersible
motor shall be operated with 3ph, 415 V(+or– 10%), 50Hz(+or-5 %) dry induction type.
Motor shall be capable of giving rated output without reduction in the expected life span when
operated continuously. The rotating assembly shall be dynamically balanced as per standards.
The starting current of the motor shall not exceed 200% of rated full load current for Star / Delta
or ATS starting under any circumstances .The motor shall be suitable for full voltage star delta
/ ATS starting. The locked rotor current of the motor shall not exceed 600% of full load current
unless otherwise specified. Motor shall be designed to withstand 120% of rated speed for two
minutes without any mechanical damage, in either direction of rotation. The motor vibration
shall be within the limit specified in applicable standards . Motor should be of IE2, explosion
proof compatible for VFD operation together with star-Delta /ATS starter, protection against
increase in stator winding temperature (15 deg Celsius), bearing temperature, leakage in the
stator housing and terminal box shall be provided and to be suitably interlocked with the control
panel for tripping the pump in case of increase in temperature beyond set limit.
Insulation class shall be of “Class H” and degree of protection shall be of IP 68 as per IS 4691.
Motor shall be suitable for continuous operation in fully submerged or partially submerged
condition.The pumpset shall be supplied with power cable of PVC insulated and PVC sheathed,
copper, flexible, round type with required conductor size and number of cores as per starting
method and of specified length for continuous use under water and air. The control cable of
PVC insulated, PVC sheathed, flexible for stator winding temperature sensor 3core x 1.5 sq.mm
copper conductor and for bimetallic switches 2core x 1.5 sqmm copper conductor shall be
provided. Motor shall be supplied with 10m of round submersible copper cable of suitable size.
The non clog submersible pumpset shall be provided with suitable starter control panel having
all protections as mentioned above. (upto 5 HP - DOL Starter, above 5 HP to 25 HP -Star Delta
Panel and beyond 25 HP shall be ATS) | - | - | - | - |
| 1.9 | Discharge upto 610 M3/hour | 1 | No | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
BOQ_809015.xls
BOQ • 0.32 MB
BOD.pdf
Tender Documents • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .