Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | ₹24.9 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹26.0 LRejected-Finance 17 23 K P ROY LANE KOLKATA 700 031 | KOLKATA | KOLKATA | WEST BENGAL | 700031 | ₹26.0 L | L2 | Rejected-Finance Being L2 |
| 3 | L3₹26.5 LRejected-Finance B 16 280 KALYANI NADIA 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | ₹26.5 L | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹49,896
Closing Date
5 Jan 2026, 1:30 pmClosed
EE/DED
Opposite of PWD Inspection Bungalow Kachari Road, Siliguri 734001, District Darjeeling
Electrical work for Creation of Burn Care Unit at 2nd floor of Trauma Care Building inside NBMCH , Darjeeling -- Air conditioning system
2025_WBPWD_973507_1
WBPWD/EE/DED/e-NIT-61 of 2025-26
Open Tender
ELECTRICAL WORKS ORG
45 days
SILIGURI
Please refer Tender documents.
4 documents required · 4 mandatory
₹49,896
16 Jan 2026
15 Dec 2025
7 Jan 2026
15 Dec 2025
5 Jan 2026
15 Dec 2025
Amount
S&+B13:B19D of Concealed type split AC machines (a set of full metal body indoor and outdoor unit) having Cooling Capacity range (26.4 KW - 27.2 KW), with fixed speed rotary compressor, refrigerant gas R32/R410 ,minium Air flow range CFM (2800-3000) or better, both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas) [ Male Ward & Female Ward ]
S&D of Concealed type split AC machines (a set of full metal body indoor and outdoor unit) having Cooling Capacity range (17.5 KW - 18.0 KW), with fixed speed rotary compressor, refrigerant gas R32/R410 ,minium Air flow range CFM (2800-3000) or better, both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas)[ OT-1 , OT -2 & Emeregency OPD + Triage ]
S&D of Concealed type split AC machines (a set of full metal body indoor and outdoor unit) having Cooling Capacity range (9.8 KW - 11.00 KW), with fixed speed rotary compressor, refrigerant gas R32/R410 ,minium Air flow range CFM (1150-1250) or better, both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas). [ Step Down Unit ]
S&D of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (5.2 KW - 5.3 KW), with fixed speed rotary compressor, refrigerant gas R32/ R410A,, Air flow range CFM (560 - 600), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas). [Room , DDC Room]
S&D of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (6.6 KW - 7.0 KW), with fixed speed compatible rotary compressor, refrigerant gas R 32 / R 410A, Air flow range CFM (780 - 850), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas) [ Visiting room ]
Supply, installation & Commissioning of hard/soft copper refrigerent pipe line with 9mm nitral rubber insulation and Al foil tape complete with fittings,elbows bends, supporting arrangements on wall (Make- Uniflow/Rajco/Nippon /Venum ) Liquid Line (3/8" OD with 0.6mm thick) [ for 5 TR/7.5 TR ]
Liquid Line (1/4" OD with 0.6mm thick) [ for 1.5 TR/2 TR/3 TR]
Suction Line (5/8" OD with 0.7mm thick) [ for 1.5TR/2TR/3TR/ 5 TR/7.5 TR ]
Supply, design, fabrication, installation of MS structural (ISI-Make) work for supports IDU/ODU both where needed i.e., 25x6 mm MS flat bar/ 50x50x6 mm MS Angle/ 50x6 MS C channel/ 25x25x6 mm MS Angle etc with 2 coat painting (Approved by EIC) and vibration pad, stainless steel (SS-304) nut bolts as per site requirement.incl scraffolding and carring charges. (ODU/IDU Support) (As per direction of E.I.C)
Supply, installation & commissioning PVC Drain pipe line (25mm OD HD 1 mm thick) with Class O fire rated nitrile rubber insulation & supports & brackets as per direction of EIC
Supply and Fixing Al powder coated Grill (Make-Primer/Air kolkata)
Supply & Installation Charges for Trap door (for IDU Maintenance) with Aluminiun channel & ACP Board (3 mm thick) (Make : Aludecor/ Protap Bond) with 19 mm. Nitral Rubber insulation, complete with linkages, levers, fittings, supports & all necessary accessories to complete the job as per direction of E.I.C
Charges for drop ceiling to cover the Indoor units made of ACP 3 mm thick. ( Make Audecor or PWD approved) as per direction of The E.I.C
ANAMICA ENTERPRISE (BID ID -7808023)
REFRICON (BID ID -7657070)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid