Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹26.0 L+₹1.1 L (4.34%)Rejected-Finance 17 23 K P ROY LANE KOLKATA 700 031 | KOLKATA | KOLKATA | WEST BENGAL | 700031 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹26.5 L+₹1.6 L (6.39%)Rejected-Finance B 16 280 KALYANI NADIA 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹49,896
Closing Date
5 Jan 2026, 1:30 pmClosed
EE/DED
Opposite of PWD Inspection Bungalow Kachari Road, Siliguri 734001, District Darjeeling
Electrical work for Creation of Burn Care Unit at 2nd floor of Trauma Care Building inside NBMCH , Darjeeling -- Air conditioning system
2025_WBPWD_973507_1
WBPWD/EE/DED/e-NIT-61 of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
SILIGURI
Please refer Tender documents.
4 documents required · 4 mandatory
₹49,896
16 Jan 2026
15 Dec 2025
7 Jan 2026
15 Dec 2025
5 Jan 2026
15 Dec 2025
Amount
S&+B13:B19D of Concealed type split AC machines (a set of full metal body indoor and outdoor unit) having Cooling Capacity range (26.4 KW - 27.2 KW), with fixed speed rotary compressor, refrigerant gas R32/R410 ,minium Air flow range CFM (2800-3000) or better, both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas) [ Male Ward & Female Ward ]
S&D of Concealed type split AC machines (a set of full metal body indoor and outdoor unit) having Cooling Capacity range (17.5 KW - 18.0 KW), with fixed speed rotary compressor, refrigerant gas R32/R410 ,minium Air flow range CFM (2800-3000) or better, both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas)[ OT-1 , OT -2 & Emeregency OPD + Triage ]
S&D of Concealed type split AC machines (a set of full metal body indoor and outdoor unit) having Cooling Capacity range (9.8 KW - 11.00 KW), with fixed speed rotary compressor, refrigerant gas R32/R410 ,minium Air flow range CFM (1150-1250) or better, both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas). [ Step Down Unit ]
S&D of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (5.2 KW - 5.3 KW), with fixed speed rotary compressor, refrigerant gas R32/ R410A,, Air flow range CFM (560 - 600), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas). [Room , DDC Room]
S&D of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (6.6 KW - 7.0 KW), with fixed speed compatible rotary compressor, refrigerant gas R 32 / R 410A, Air flow range CFM (780 - 850), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas) [ Visiting room ]
Supply, installation & Commissioning of hard/soft copper refrigerent pipe line with 9mm nitral rubber insulation and Al foil tape complete with fittings,elbows bends, supporting arrangements on wall (Make- Uniflow/Rajco/Nippon /Venum ) Liquid Line (3/8" OD with 0.6mm thick) [ for 5 TR/7.5 TR ]
Liquid Line (1/4" OD with 0.6mm thick) [ for 1.5 TR/2 TR/3 TR]
Suction Line (5/8" OD with 0.7mm thick) [ for 1.5TR/2TR/3TR/ 5 TR/7.5 TR ]
Supply, design, fabrication, installation of MS structural (ISI-Make) work for supports IDU/ODU both where needed i.e., 25x6 mm MS flat bar/ 50x50x6 mm MS Angle/ 50x6 MS C channel/ 25x25x6 mm MS Angle etc with 2 coat painting (Approved by EIC) and vibration pad, stainless steel (SS-304) nut bolts as per site requirement.incl scraffolding and carring charges. (ODU/IDU Support) (As per direction of E.I.C)
Supply, installation & commissioning PVC Drain pipe line (25mm OD HD 1 mm thick) with Class O fire rated nitrile rubber insulation & supports & brackets as per direction of EIC
Supply and Fixing Al powder coated Grill (Make-Primer/Air kolkata)
Supply & Installation Charges for Trap door (for IDU Maintenance) with Aluminiun channel & ACP Board (3 mm thick) (Make : Aludecor/ Protap Bond) with 19 mm. Nitral Rubber insulation, complete with linkages, levers, fittings, supports & all necessary accessories to complete the job as per direction of E.I.C
Charges for drop ceiling to cover the Indoor units made of ACP 3 mm thick. ( Make Audecor or PWD approved) as per direction of The E.I.C
ANAMICA ENTERPRISE (BID ID -7808023)
REFRICON (BID ID -7657070)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .