| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.8 L+₹1.0 L (5.45%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance REFER SUMMARY | |
| 3 | L3₹19.9 L+₹1.1 L (5.65%)Rejected-Finance | L3 | Rejected-Finance REFER SUMMARY | |
| 4 | L4₹21.4 L+₹2.6 L (14.0%)Rejected-Finance NEW HOSPITAL ROAD UDHAMPUR UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance REFER SUMMARY | |
| 5 | L5₹21.7 L+₹2.9 L (15.3%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L5 | Rejected-Finance REFER SUMMARY |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
27 Sept 2022, 6:00 pmClosed
GE AF UDHAMPUR
GE AF UDHAMPUR
REPAIR/REPLACEMENT /RENEWAL OF OLD UNSV FITTING ALONGWITH CONVERSION OF ALUMINIUM WIRING INTO COPPER WIRING AND CONNECTED MISC WORK AT LOWER CAMP AT 39 WING AF STATION UDHAMPUR
2022_MES_549075_1
GE/AFU-47/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE AF Udhampur
as per tender documents
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹50,000
Yes
23 Oct 2022
1 Sept 2022
29 Sept 2022
1 Sept 2022
27 Sept 2022
15 Sept 2022
1 Sept 2022 - 7 Sept 2022
Amount
Taking down carefully aluminum/copper point wiring (light/ fan/socket or power) complete with fittings such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCBs, Main switches from control board and making good disturbed surfaces of walls, floor to match with existing specifications complete all as specified and as directed by Engineer-in-Charge.
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through existing conduits, with new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified and as directed by Engineer-in-Charge. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Description all as per serial item No.2 here-in-before but for one 6 Amps socket outlet on the Independent board complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No.2 here-in-before but for one 6 Amps socket outlet on the same board board complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No.2 here-in-before but for one 6 Amps on the Bell point complete all as specified and as directed by Engineer-in-Charge.
Point wiring for one 16 Amps socket outlet independent with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through existing conduits with new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified and as directed by Engineer-in-Charge. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified and as directed by Engineer-in-Charge. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Description all as per serial item No.7 here-in-before but 2 way point controlled by two switches complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No.7 here-in-before but for one 6 Amps socket outlet on the same board complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No. 7 here-in-before but for one 6 Amps socket outlet on the Independent board complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No. 7 here-in-before but for one 6 Amps on the bell point complete all as specified and as directed by Engineer-in-Charge..
Point wiring for one 16 Amps socket outlet independent with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified and as directed by Engineer-in-Charge. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Switch piano type 6 AMP,two way conforming to IS-3854 complete all as specified and as directed by Engineer-in-Charge.
Switch piano type 6 AMP,one way conforming to IS-3854 complete all as specified and as directed by Engineer-in-Charge.
Socket shuttered outlet 2 in 1 6 Amp complete all as specified and as directed by Engineer-in-Charge.
Switch Socket combination 5 in 1 , 6 Ampcomplete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of 15 Amps switch socket combination including taking down complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of Bell push flush type 5 Amps complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of Bell AC 230Volt single pole complete all as specified and as directed by Engineer-in-Charge.
Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed by Engineer-in-Charge.
Lamp holder, insulated body, cord grip pattern SP 230 volt,as per existing size suitable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of steped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as requied including taking down complete all as specified and as directed by Engineer-in-Charge.
Modular electronic fan regulator normal step type 230 volts complete all as specified and as directed by Engineer-in-Charge.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid concealed conduit, heavey duty and connected to main board and making good disturbed surfaceas per existing colour after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed by Engineer-in-Charge. Note: Two runs each of 4.00 sqmm main cable and one RM of 4.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire, drawn through Heavey duty surface PVC conduit and connected to main board and making good disturbed surface as per existing colour after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed by Engineer-in-Charge. Note: Two runs each of 4.00 sqmm main cable and one RM of 4.00 sqmm cable as earth wire together shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire, drawn through Heavey duty PVC casing caping and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed by Engineer-in-Charge. Note: Two runs each of 6.00 sqmm main cable and one RM of 6.00 sqmm cable as earth wire together shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid concealed conduit, heavey duty and connected to main board and making good disturbed surfaceas per existing colour after taking out old unserviceable sub main wiring and disposing from sitecomplete all as specified and as directed by Engineer-in-Charge. Note: Two runs each of 10.00 sqmm main cable and one RM of 10.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Supply and fixing of VTPN MCCB 125 Amps DB lk-09 isolator Neutral bar, insulated busbar assembly D/D distribution board, VTPN, 4 way 440 volts having HSNCODE 8537 protection, double door with provision for fixing of MCCBs as incomer and MCBs as outgoing complete after taking down existing unservicable main switch, busbar, GI box including accessories therein & disposing from site including taking down complete all as specified and as directed by Engineer-in-Charge.
MCCB 4P 100 Amps, 415 Volts, 16 KA having breaking capacity including taking down existing old unservicable including accessories therein & disposing from sitecomplete all as specified and as directed by Engineer-in-Charge.
MCCB 4P 63 Amps, 415 Volts,16KA having breaking capacity including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed by Engineer-in-Charge.
MCB TPN 63 Amps, 415 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed by Engineer-in-Charge.
Sheet metal enclosures for DBs SPN 8 way with 200Amps rated busbar (when MCBs to be used) flush mounted including taking down existing unserviceable DBs /board /box including accessories therein and disposing off complete all as specified and as directed by Engineer-in-Charge.
Sheet metal enclosures for DBs SPN 12 way with 200Amps rated busbar (when MCBs to be used) flush mounted including taking down existing unserviceable DBs /board /box including accessories therein and disposing off complete all as specified and as directed by Engineer-in-Charge.
MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed by Engineer-in-Charge.
MCB SP 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 03mm thick Hylem sheet (white colour) suitable for ceiling fan/wall plug etccomplete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of fan round sheet plastic PVC fan sheet cover Wall plug size 160 mm complete all as specified and as directed by Engineer-in-Charge.
Cutting of existing wall and fixing of Exaust fan and making good such as plaster /randering and white wash etc and fixing exhaust fan bracket with and suitable size of faistner not less than 30cm complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of PVC Exhaust Fan 100 mm with lovour complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs plug top 3 pin 15 Amp ISI marked complete all as specified and as directed by Engineer-in-Charge.. Make Anchor / Havells / Bajaj .
Supply and fixing Plug socket board with metal socket and plug DP 20 Amp (I Phase ,1 Neutral and earth ) complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 3 core PVC insulated copper cable of size 40/0.0076 multi stranded complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs of Heavey Stainless steel geyser connection pipe 304 Grade Graiding for extra connection including taking down complete all as specified and as directed by Engineer-in-Charge. . (size 18" mm)
S&F in repairs of Heavey duty PVC pipe( 36" inch for geyser connection pipe for extra connection inclluding taking down complete all as specified and as directed by Engineer-in-Charge. Make : Usha / Bajaj/ Crompton
Taking down carefully old serviceable/ unserviceable existing conventional light fittings such as T-5/ T-8/ box type /bulk head, 1x40 watt; 1x20 watt, ceiling panel lights etc from existing buildings and disposing off from site complete all as specified and as directed by Engineer-in-Charge. Note : Existing serviceable LED luminaries will not be taken down / replaced.
Supply and fixing LED lights fitting 1x 20W LED 6500K, 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy box type four feet with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking downcomplete all as specified and as directed by Engineer-in-Charge.
S&F in replacement LED retrofit lamp with maximum wattage 7 watt (lumen output not less than 900 lumens) with B 22 holder base with thermal conductive engineering plastic white colour housing and aluninium heat sink with specially designed fins clear/cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation long life burning hours 50000 hours complete all as specified.(including taking down of existing serviceable /unserviceable lamps and disposing off complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 10 W LED 6500 K, 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy box type Two feet with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Decorative wall LED lights fixture made up of polycarbonate suitable for 9 watt retrofit LED Lamp B-22 base complete all as specified and as directed by Engineer-in-Charge. Havells or its equivalent Bajaj/philips.
S&F integrated LED bulk head luminarie fittings in engineering plastic housing with clear prismatic /opal diffuser /pressure aluminium die cast housing in white powder coating minimum IP-65 protection, system wattage not more than 10 watt (lumen output not less than 800 lumen) power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation light fitting long life burning hours 50000 hours with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and as directed by Engineer-in-Charge..
Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion complete all as specified and as directed by Engineer-in-Charge..
Supply and fixing of Earth continuity conductor or main4mm Galvanised iron streep strip or main earthing lead fixed to wall on battenor recess or chases including plastic type insulatoror buried inground or drawn in conduit/pipe orfixed to poles or any other indicatedsituation for loop earthing etc. all as required and including taking out old unsv up to building height .complete all as specified and as directed by Engineer-in-Charge.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 50 Sqmm 3.5 core laid on walls/floors or in air with saddles and gutties including pvc conduit pipe clips,nails etc complete all as specified and as directed by Engineer-in-Charge.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 70 Sqmm 3.5 core laid on walls/floors or in air with saddles and gutties including pvc conduit pipe clips,nails etccomplete all as specified and as directed by Engineer-in-Charge.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 35 Sqmm 3.5 core laid on walls/floors or in air with saddles and gutties including pvc conduit pipe clips,nails etc complete all as specified and as directed by Engineer-in-Charge.
Suppy and fixing of GI tube light grade of bore 80 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable up to building height complete all as specified and as directed by Engineer-in-Charge.
PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in foundation of poles/stays etc complete all as specified and as directed by Engineer-in-Charge.
PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in coping around including necessary form work and fair finishing of exposed surfaces complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for foundation, laying of pipes and LT cable and getting out, complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and as directed by Engineer-in-Charge.
Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , ccomplete all as specified and as directed by Engineer-in-Charge.
Dry sand cushioning to under ground cable all as per clause 19.75 of SSR Part - I laid before and after laying of cable, complete all as specified and as directed by Engineer-in-Charge.
Sub class 'B' old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable in repair , complete all as specified and as directed by Engineer-in-Charge.
DAVINDER SINGH
KARAN TRADERS
MAHAJAN TRADING CO
ANIKET TRADERS
JANDIAL ENTERPRISES
PARAS RAM ASGOTRA AND SONS
RANBIR ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .