Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAdmitted-Finance | ₹1.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.8 Cr+₹67,605.88 (0.39%)Admitted-Finance | ₹1.8 Cr+₹67,605.88 (0.39%) | L2 | Admitted-Finance |
| 3 | L3₹1.8 Cr+₹76,822.72 (0.44%)Admitted-Finance | ₹1.8 Cr+₹76,822.72 (0.44%) | L3 | Admitted-Finance |
| 4 | L4₹1.8 Cr+₹3.0 L (1.73%)Admitted-Finance | ₹1.8 Cr+₹3.0 L (1.73%) | L4 | Admitted-Finance |
| 5 | L5₹1.8 Cr+₹4.5 L (2.55%)Admitted-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹1.8 Cr+₹4.5 L (2.55%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | mantech engineers L1 | Vijaypower Generators Limited L5 | DEEPAK ELECTRICALS L7 | VIRTUSTECHNO L4 | ADARSH ELECTRIC WORKS L2 | Leapfrog Engineering Services Private Limited L3 | Suvarna Infrateck L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of 500 KVA Diesel Generator set with following specifications (confirming to CPCB IV+ norms amended from time to time)
Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002 /ISO 3046 Generator set specifications.
(A) Diesel Engine:
Diesel generating set are rated at 1500 RPM and conform to ISO 8528 specifications.The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046.The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor,A1 Class. Spin-on lube oil filter,Spin-ondual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation
(B) Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation
(C) Alternator:
Alternator is suitable for operation at 1500 RPM, 415V, 0.8 pf(lag) suitable for 50Hz ,3phase , 4wire systems, conforming to IS /IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. Thealternator shall have ±1.0% Voltage regulation (max) instatic conditions- IP: 23 protections with insulation class F&H.
(D)Mounting arrangement: Engine and alternator aremounted on a common MS fabricated base frame with AVM pads
(E) Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1ph or 3ph line to line and line to neutral voltage, Current (1ph or 3ph), kVA (3ph and total), Frequency, Provide Engine Data,Starting battery voltage,Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions,Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,-Auto start mode accepts a ground signal from remote devices to automatically start the DGset The remote start will also wake up the control system from sleep mode.
(F) Engine Starting- The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 secs to start after remote start signal and time delayof 0 600secs prior to shut down after stop signal genset is not working. Engine Protective functions include ,Configurable alarm output, Emergency stop: Annunciated whenever an emergencystop signal is receivedby the control. Lowlube oil pressure warning and Shutdown, High engine water temp warning / Shutdown, Low coolant temp warning, Sensor failure indication, Low and high battery voltage warning, Weak battery warning, Fail to start shut down, Cracking lockout: Control will not allow the starter to engage or to crank the running engine Cyclic cranking: Configurable for the number of starting cycle, (1to 7) and duration of crank and rest periods. Alternator Protective functions includes,-High and Low AC voltage shutdown, Under and Over frequency shutdown / warning, Loss of sensing voltage input shut down.
(G) Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 m sound levels specified by Ministry of Environment & Forest The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1m at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish,With UV resistant powder coating, can withstand extreme environment,Use of special hardware for longer life, Insulation material meets exacting IS 8183 specifications for better sound attenuation, Flush styling-n oprojections, Fluid drains for lube oil and fuel,Fuel filling point inside the enclosure. The complete set shall have sufficient safety and adhere to NEC ,NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. | 2 | Set | 39,85,000 ₹94,04,600 | 46,08,000 ₹1,08,74,880 | 44,30,000 ₹1,04,54,800 | 45,20,650 ₹1,06,68,734 | 42,10,000 ₹99,35,600 | 39,13,558 ₹92,35,996.88 Lowest | 41,25,500 ₹97,36,180 |
| 2.00 | Supply, Erection, testing and commissioning of Microprocessor based AMF cum Synchronizing DG Set controller panel suitable for 2 x 500 KVA DG sets with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage and frequency sensing as per DG Set manufacturer standard Practice controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on , ON / OFF Push buttons, AMF mode, bypass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility.
DG Set controller should have Auto Synchronizing, Auto Load Sharing, Load Dependent Start/ Stop facility etc. inbuilt without depending on external PLC. The panel is of cubical type base / floor mounting made of 1.6 mm thick MS sheet powder coated with 7 tank process with hinged doors, undrilled bottom gland plate, 1600 A aluminium Bus Bar with the following switch gears.
Incoming:
(1) EB Incomer: 1200A 4 pole microprocessor based LSI EDO type ACB,50kA - 1 No.
(2) DG Incomer: 800A 4 pole microprocessor based LSI EDO type ACB,50kA - 2 Nos.
(3) Outgoing: 1 x 630 A,35kA 4 pole microprocessor based LSI MCCB and 2 x 400 A, 35 KA, 4 pole microprocessor based LSI MCCB
Each feeder have individual Multi Function Meter to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH & PF. LED Indicating lamps for load ON, Mains ON and load on DG set, Fuse/ MCB for instruments. Auto/Manual/Test/Off selector switch , Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-0.5 for metering. Providing suitable screened control cable and 1.5 Sq.mm UG copper control cable between DG set & Synchronizing panel, ensuring proper shielding and reliable signal transmission.
The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. (Make: Woodword or similar approved) | 1 | Each | 14,00,000 ₹16,52,000 | 10,05,000 ₹11,85,900 | 16,00,000 ₹18,88,000 | 9,95,258.3 ₹11,74,404.79 | 6,25,950 ₹7,38,621 Lowest | 16,77,300 ₹19,79,214 | 20,35,000 ₹24,01,300 |
| 3.00 | EXHAUST SYSTEM ACCESSORIES:
Supply and installation of 250 mm dia (NB) exhaust pipe of thickness not less than 5 mm thick with supply of all required materials complete as required | 70 | Mtr | 3,620 ₹2,99,012 | 5,100 ₹4,21,260 | 6,612 ₹5,46,151.2 | 6,720 ₹5,55,072 | 4,446 ₹3,67,239.6 | 2,729 ₹2,25,415.4 Lowest | 3,565 ₹2,94,469 |
| 4.00 | Supply and installation of 250 mm dia (NB) MS bend with all necessary accessories | 4 | Nos | 3,960 ₹18,691.2 | 750 ₹3,540 Lowest | 3,000 ₹14,160 | 2,352 ₹11,101.44 | 1,111.5 ₹5,246.28 | 2,678 ₹12,640.16 | 4,197.5 ₹19,812.2 |
| 5.00 | Providing thermal insulated mineral wool / rack wool of min 50 mm thick, lagging with chicken mesh and 24 gauge aluminum cladding over the 250mm dia (NB) exhaust pipe including supply of all required materials complete as required. | 70 | Mtr | 1,550 ₹1,28,030 | 850 ₹70,210 Lowest | 2,500 ₹2,06,500 | 1,740 ₹1,43,724 | 3,627 ₹2,99,590.2 | 1,661 ₹1,37,198.6 | 1,725 ₹1,42,485 |
| 6.00 | Supply & Installation of 40mm dia Class 'C MS pipe including necessary valves and accessories required for the supply lines from existing fuel pipe line to the day fuel tank of the be set. The pipe shall be painted with primer over which 2 coats of approved color paint shall be applied, supply of fixing accessories, control valves,necessary piping accessories, necessary supports, plastic emulsion painting and all required materials complete as required. Scope is inclusive of interconnection with existing fuel pipe line including supply all necessary materials required. | 150 | Mtr | 690 ₹1,22,130 | 570 ₹1,00,890 | 280 ₹49,560 Lowest | 1,020 ₹1,80,540 | 1,345.5 ₹2,38,153.5 | 639 ₹1,13,103 | 546.25 ₹96,687 |
| 7.00 | Design, manufacture, supply, installation, testing and commissioning of 990 Lts. capacity fuel tank made of 3 mm thick MS sheet, primer and double coat of painting with 3 Nos ball valve suitable for 40 mm dia MS pipe for connecting day fuel tank and 2 nos. 500 KVA DG sets with nessary suppoort etc as required. | 1 | Job | 97,750 ₹1,15,345 | 45,000 ₹53,100 Lowest | 85,000 ₹1,00,300 | 60,000 ₹70,800 | 58,500 ₹69,030 | 91,825 ₹1,08,353.5 | 81,650 ₹96,347 |
| 8.00 | Supply and fixing of float valve in the existing diesel tank inside DG set enclosure to close the diesel intake from the external fuel tank. | 2 | Nos | 17,250 ₹40,710 | 5,400 ₹12,744 | 3,000 ₹7,080 | 1,800 ₹4,248 | 8,775 ₹20,709 | 11,174 ₹26,370.64 | 1,000 ₹2,360 Lowest |
| 9.00 | Supply, fabrication and erection of structure made of MS support suitable for exhaust pipe, residential silencer, etc. using angles/ channels, steel sections, U Clamps etc.complete with one coat of zinc chromate primer and 2 coats of black enamel paint. Supplying and fixing Red colour LED Aviation lamp with necessary UG armoured cable to be fixed on top of the MS structure. | 8,000 | Kgs | 125 ₹11,80,000 | 108 ₹10,19,520 | 170 ₹16,04,800 | 102 ₹9,62,880 Lowest | 128.7 ₹12,14,960 | 120 ₹11,32,800 | 126.5 ₹11,94,160 |
| 10.00 | Supply, loading, transportation and unloading of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.
i) 400 Sqmm, 3.5 Core, (39 GI Strips - 4 x 0.8 mm) | 450 | Mtr | 1,690 ₹8,97,390 Lowest | 2,253 ₹11,96,343 | 1,770 ₹9,39,870 | 2,054.1 ₹10,90,728 | 1,813.5 ₹9,62,968.5 | 2,153 ₹11,43,243 | 2,070 ₹10,99,170 |
Tender Value
Refer Docs
EMD Value
₹3.6 L
Closing Date
18 Dec 2025, 3:00 pmClosed
Registrar
Registrar office, IISc, Bangalore
Supply Installation Testing and Commissioning of 2 x 500 KVA Diesel Generator set at CIDR
2025_IISC_887603_1
IISc/CIDR/01/2025
Open Tender
Electrical Works
Works
90 days
CIDR, IISc, Bangalore
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹3.6 L
Yes
Online
14 Jan 2026
28 Nov 2025
19 Dec 2025
28 Nov 2025
18 Dec 2025
6 Dec 2025
4 Dec 2025
Amount
EXHAUST SYSTEM ACCESSORIES: Supply and installation of 250 mm dia (NB) exhaust pipe of thickness not less than 5 mm thick with supply of all required materials complete as required
Supply and installation of 250 mm dia (NB) MS bend with all necessary accessories
Providing thermal insulated mineral wool / rack wool of min 50 mm thick, lagging with chicken mesh and 24 gauge aluminum cladding over the 250mm dia (NB) exhaust pipe including supply of all required materials complete as required.
Supply & Installation of 40mm dia Class 'C MS pipe including necessary valves and accessories required for the supply lines from existing fuel pipe line to the day fuel tank of the be set. The pipe shall be painted with primer over which 2 coats of approved color paint shall be applied, supply of fixing accessories, control valves,necessary piping accessories, necessary supports, plastic emulsion painting and all required materials complete as required. Scope is inclusive of interconnection with existing fuel pipe line including supply all necessary materials required.
Design, manufacture, supply, installation, testing and commissioning of 990 Lts. capacity fuel tank made of 3 mm thick MS sheet, primer and double coat of painting with 3 Nos ball valve suitable for 40 mm dia MS pipe for connecting day fuel tank and 2 nos. 500 KVA DG sets with nessary suppoort etc as required.
Supply and fixing of float valve in the existing diesel tank inside DG set enclosure to close the diesel intake from the external fuel tank.
Supply, fabrication and erection of structure made of MS support suitable for exhaust pipe, residential silencer, etc. using angles/ channels, steel sections, U Clamps etc.complete with one coat of zinc chromate primer and 2 coats of black enamel paint. Supplying and fixing Red colour LED Aviation lamp with necessary UG armoured cable to be fixed on top of the MS structure.
Supply, loading, transportation and unloading of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. i) 400 Sqmm, 3.5 Core, (39 GI Strips - 4 x 0.8 mm)
ii)300 Sqmm, 3.5 Core, (32 GI Strips - 4 x 0.8 mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. as required. Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. i) 3½ X 400 sq. mm (82mm)
ii) 3½ X 300 sq. mm (70mm)
Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with excavation, backfilling, charcoal/ coke and salt as required.
Supplying and laying 50 mm X 6 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm and with protection sleeve)
Supplying and fixing Moulded Case Circuit Breaker(MCCB) over the existing panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as per IS/ IEC60947-2. (Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short- Cicrcuit/ OverLoad. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and interna lpower circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 4P -800 A, 50 kA
Supply and fixing in Rotary handle for MCCB
Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic /FRP/ DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 1000 A double run of 4 x 60 x 10 mm Aluminium Strips
ISI Marked 4.5kg capacity CO2 Fire Extinguisher with bracket etc.,
Fire Buckets 3 Nos with MS stand filled with Sand and water with roof top cover
Disconnection of 630A and 400A MCCB, bus bar erection / termination, modification of exisiting panel and fixing of 800A MCCB in same panel.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates Including shuttering & centering.
Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, inculding shuttering , deshuttering materials, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Including shuttering & centering.
Preparation of necessary drawings for DG Sets, getting approval from the Chief Electrical Inspectorate/Electrical Board/ Pollution Control Board before taking up work and to furnish completion report, arranging for inspection, giving trial run on load, obtaining approval for commissioning the sets by paying necessary fees for inspection etc., as required.
Disconnection of existing LT cable 3C x 400 Sq mm , 3C x 240 Sqmm and Fixing, crimping, jointing of Aluminum lugs for 3C x 400 sq.mm Flat wire armoured cable complete with colour coded insulated tapes and interchage the cable from LT feerder panel to LT kiosk, and etc.,as required.
Supplying & fixing of FIRST AID CHART (English, Hindi & Kannada) with lamination complete as required.
Supplying and Providing Pre cast Cable Route/ Joint marker using M15 grade Concrete, MS rods / GI plate / of approved size/ shape (as per the approved drawings) to be laid in UG cable works. The rate includes the cost of material, labour charges, loading, unloading, handling, transportation charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure.
Supplying and installation of RUBBER MAT 1mtr x 1mtr -10 mm thick. complete including cost of materials, labour, usage charges of machinery complete as per specifications.
ADARSH ELECTRIC WORKS (BID ID -3330003)
Leapfrog Engineering Services Private Limited (BID ID -3330859)
VIRTUSTECHNO (BID ID -3335320)
Vijaypower Generators Limited (BID ID -3335732)
Suvarna Infrateck (BID ID -3333796)
DEEPAK ELECTRICALS (BID ID -3335768)
stage.html
html • 0.04 MB
techsummary_932959.pdf
BOQ Comparative Chart
xlsx
cancelled_1.pdf
pdf • 0.18 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
2X500KVADGCIDRTenderdocument.pdf
Tender Documents • 0.97 MB
BOQ_932959.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .