Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAdmitted-Finance | ₹2.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.9 Cr+₹22.4 L (8.45%)Admitted-Finance | ₹2.9 Cr+₹22.4 L (8.45%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | INGENIOUS ENERGY INFRATECH L2 | GUARDIAN ENGINEERS L1 |
|---|---|---|---|---|---|
| 1.00Supply ,Erection testing and commissioning of 02 Nos of new 33 KV line( Dool-I & Dool -II) | |||||
| 2.00 | 11 Mtr. Long ST Pole (ST-540SP56) | 450 | Nos | 1,80,00,000 ₹1,80,00,000 | 1,53,00,000 ₹1,53,00,000 Lowest |
| 3.00 | GI Channel X-arm including clamps and braces | 11,124 | Kg | 11,01,276 ₹11,01,276 Lowest | 15,12,864 ₹15,12,864 |
| 4.00 | 100 mm² ACSR Dog Conductor | 55.62 | Km | 55,06,380 ₹55,06,380 Lowest | 57,28,860 ₹57,28,860 |
| 5.00 | PG Clamps for 100 mm² ACSR Conductor | 324 | Nos | 25,920 ₹25,920 Lowest | 64,800 ₹64,800 |
| 6.00 | 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm | 918 | Nos | 4,40,640 ₹4,40,640 | 3,67,200 ₹3,67,200 Lowest |
| 7.00 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm | 432 | Nos | 3,06,720 ₹3,06,720 Lowest | 4,32,000 ₹4,32,000 |
| 8.00 | Galvinized Nuts and Bolts. | 450 | kg | 38,250 ₹38,250 Lowest | 58,500 ₹58,500 |
| 9.00 | Danger Plates with Clamps | 400 | Nos | 44,000 ₹44,000 Lowest | 1,60,000 ₹1,60,000 |
| 10.00 | Anti-Climbing Device with Clamps | 450 | Nos | 67,500 ₹67,500 Lowest | 1,80,000 ₹1,80,000 |
Tender Value
₹2.6 Cr
EMD Value
₹5.2 L
Closing Date
11 Oct 2021, 4:00 pmClosed
OFFICE OF THE EXECUTIVE ENGINEER STD DODA
OFFICE OF THE EXECUTIVE ENGINEER STD DODA
Shifting Re-alignment of 33 KV Dool-I n II lines emanating from NHPC Grid station Kishtwar by way of laying of 02 Nos new 33 KV Lines of 9 Km each Dool-I n II from the same Grid Station upto proposed tapping Point at Hunjella
2021_PDD_134011_1
STD/Doda/21-22/ 16 of 2021
Open Tender
Electrical Works
Turn-key
180 days
KISHTWAR
KINDLY REFER TO SBD
2 documents required · 2 mandatory
₹4,000
THE EXECUTIVE ENGINEER STD DODA
₹5.2 L
Yes
7 Dec 2021
11 Aug 2021
13 Oct 2021
11 Aug 2021
11 Oct 2021
11 Aug 2021
11 Aug 2021 - 17 Aug 2021
Supply ,Erection testing and commissioning of 02 Nos of new 33 KV line( Dool-I & Dool -II)
11 Mtr. Long ST Pole (ST-540SP56)
GI Channel X-arm including clamps and braces
100 mm² ACSR Dog Conductor
PG Clamps for 100 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .6cum /pole
Stone Pad (300 mm x 300 mm x 75 mm)
Aluminium Jointing Sleeves
Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete
Guard netting
INGENIOUS ENERGY INFRATECH
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.18 MB
Tendernotice_2.pdf
PDF • 1.21 MB
BOQ_267673.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .