Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.5 CrAccepted-AOC | ₹1.5 Cr Quoted ₹1.6 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹1.8 Cr+₹25.9 L (16.5%)Rejected-Finance | ₹1.8 Cr+₹25.9 L (16.5%) | 2 | Rejected-Finance Not Lowest |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
3 Jan 2022, 6:00 pmClosed
CWE Bathinda
CWE Bathinda
SPL REPAIR OF HQ CE BTZ BLDG NOS P199 P200 P277 AND P885 OF HQ CE BTZ AT BATHINDA MIL STN
2021_MES_486020_2
CWE BTD 8232/E8
Open Tender
Civil Works
Item Rate
270 days
Bathinda
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (North) Bathinda
₹2.6 L
Yes
10 Feb 2022
13 Dec 2021
5 Jan 2022
13 Dec 2021
3 Jan 2022
21 Dec 2021
13 Dec 2021 - 20 Dec 2021
Amount
Dismantling of brick tiles or terracing tiles, single layer on roof including any type of water proofing membrane and disposal of retrieved material upto a distance not exc 250 mtr away complete all as specified.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness recovered or only a part there of) including removing the demolished material not exceeding 250 mtr away from site and disposal off in low lying area complete.
Demolition of PCC padding including APP membrane from roof surface of any floor in roof treatment complete all as specified.
Removal of PUFF insulation on roof surface including removal of rubbish and cleaning complete all as specified.
M & L rendering 10 mm thick plaster in CM 1:3 with WPC as per manufacturers instructions on roof surface for roof treatment complete all as specified.(Note :- WPC shall be measured and paid for separately.)
M & L for applying bituminous primer on plastered surface of roof at the rate of 400 ml per sqm complete all as specified.
M & L for APP based polymeric membrane mat finished top of weighing not less than 3 Kg / Sqm and minimum 3mm thick reinforced with polyester non woven fabric (Weight not less than 150 Gms / Sqm) laid on primed surface by forced application complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking , sweeping , clean and washing down with water to remove dust etc and brushing with neat cement slurry @ 3.0 Kg of cement per Sqm all as directed
M & L for providing brick lime concrete on roof etc complete all as specified in para 4.1 D of SSR Part-II as directed.
M & L for 40 mm thick brick tiles laid / bedded in CM (1:6) joints grouted flush in CM 1:3 mixed with integral liquid water proofing compound as per manufacturers instruction all as specified (Note :- WPC shall be measured and paid for separately.)
All as per ser item No. 10 here-in-above but except tiles
M & L for 25 mm thick PCC (1:2:4) type B0 using 12.5mm graded stone aggregate as in flooring/ roof padding including mixing with WPC and finished even and fair complete all as specified.(Note :- WPC shall be measured and paid for separately.)
Supply only liquid water proofing material, ISI marked.
M & L for UV stable single component fibre reinforced elastomeric liquid applied water proofing membrane having solid content of 55 % formulated with PU Hybrid polymers and reinforcing acrylic fibers and having sun reflectivity index ( SRI) of 106. The application of the material should be done in 3 coats ( 6 hrs gap between each coat ) on the sub strate applying 1st self priming coat @ ratio of damp proof ultra and water 1:3 then 2 undulated coat of damp proof ultra obtaining coverage @ 1Ltr / 10 Sq ft in 3 coats. The vital physical and chemical parameters shall be as under:- (a) Minimum Elongation at break off 350 % . (b) Crack bridging ability of 2.5 mm @ 650 Microns thickness (c) Resist positive hydro static pressure of upto 10 Bars. Note :- The material shall be applied with bruch or roller complete in all respect as directed by Engineer-in-Charge. Also proper surface preparation along with coning at comers.
M & L for Cutting grooves in brick wall , 75mm wide and 65mm deep and shaping horizontal face of grooves with cement mortar 1:3 complete all as specified and as directed.
M & L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, watering, grouting with cement and sand slurry (1:3) complete all as specified.
Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc complete all as specified.
M & L for rendering 10 mm thick in cement mortar (1:6) on fair or other then fair faces of brick work or concrete surfaces and finishing even & smooth without using extra cement complete all as specified.
M & L for rendering 15 mm thick in cement mortar (1:4) to fair faces of brick work or concrete surfaces including mixing of water proofing compound, and finishing even & smooth without using extra cement complete all as specified.
M&L for rendering 5 mm thick in cement mortar in (1:3) finishing the surfaces even and smooth on ceiling complete all as specified.
M&L for rendering 15 mm thick in cement mortar in (1:3) to fair faces of brick wall or concrete surfaces , finishing the surfaces even and smooth without using extra cement complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M & L for vitrified ceramic tiles, 10 mm thick double charged, dark shade, area of each tiles exceeding 0.36 Sqm but not exc 0.42 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 15 mm thick Screed bed or bedding layer in CM (1:6) complete all as specified. Note: Only course sand shall be used in screed bed.
M & L for vitrified ceramic tiles, 10 mm thick double charged, dark shade, area of each tiles exceeding 0.42 Sqmbut not exc 1 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 15 mm thick Screed bed or bedding layer in CM (1:6) complete all as specified. Note: Only course sand shall be used in screed bed.
All as per ser item No. 24 here-in-before but as in skirting over and including 10 mm thick including rendering CM (1:4) complete all as specified
M & L for non skid joint free ceramic coloured tiles, 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles and including 15 mm thick screed bed of cement motor (1:6) complete all as specified.
M & L for non skid joint free ceramic coloured tiles, 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles and including 10 mm thick screed bed of cement motor (1:6) complete all as specified.
S & F glazed ceramic coloured tiles 450 x 350mm, 7 to 8mm thick in vertical surfaces such as dado / skirting, set and jointed in neat cement slurry and pointed in white or coloured cement pigmented to the match the shade of tiles laid over and including 15 mm thick rendering in cement mortar (1:4) as backing coat and finish the surface rough to receive the tile complete all as specified.
M & L 16 to 20 mm thick machine cut black marble stone slab as in flooring, steps, over and including 10 mm thick cement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified.
All as per ser item No. 29 here-in-before but as in skirting riser etc over and including 10 mm rendering CM (1:4) complete all as specified
M & L for machine cut kota stone slab as in flooring, steps, 20-25 mm thick over and including 15 mm thick cement screed bad in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified.
All as per ser item No. 31 here-in-before but as in skirting riser etc over and including 10 mm thick rendering as CM (1:4) complete all as specified
M & L for PCC (1:3:6) type C1 using 20mm graded stone aggregate in hold fast blocks including necessary forms, moulds etc complete all as specified.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified.
M & L for 100 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base, floor, path, pavings etc complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified.
M&L for machine pressed rubber moulded precast interlocking paver block with grey cement and pigment, factory made, any shape and size, conforming to IS 15658-2006 of 60 mm thickness, made out of M-35 grade & including minimum 25mm thick sand cushioning below interlocking paving block complete laid dry of any description in floors, aprons etc complete all as directed. (Sample to be approved by GE)
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified.
M & L for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as floors, plinth protection, path etc and finishing the surface even and smooth without using extra cement complete all as specified.
M & L for PCC (1:2:4) type B2 using 40mm graded stone aggregate in surface channels and drains including necessary form work complete all as specified.
Demolition of RCC as in roof slabs (other than ground floors), beams, stair case, landing, chajjas, and similar suspended work (reinforcement cut as required to facilitate demolition).
M & L for RCC M 25 design mix (using 20mm graded stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, deck slabs and in shelves and the like. (Reinforcement will be measured and paid for separately)
M & L for RCC M 25 design mix (using 20mm graded stone aggregates) as in fins, fascias, louvers, parapets, and railings exc. 60cm in height, balustrade, and the like. (Reinforcement will be measured and paid for separately)
M & L for RCC M 25 design mix (using 20mm graded stone aggregates) as in beams, lintels and similar items complete all as specified.
Use and waste of form work to sides and soffits of floor or roof beams , cantilevers, shelves etc rough finished surface complete all as specified.
Use and waste of form work to sides and soffits of fins, louvers, fascia and similar items rough finished surface complete all as specified.
Use and waste of form work to sides and soffits of floor or roof slabs and similar items shelves etc rough finished surface complete all as specified.
S & F mild steel TMT bars 10 mm dia , and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to Fe 410-W, Gde E-250 complete all as specified .
All as per ser item No. 48 here-in-before but 6 to 8mm dia complete all as specified.
All as per ser item No. 48 here-in-before but 6 to 8mm dia in stirrups, spacess and binders complete all as specified.
M & L for guniting/ short crating of RCC columns, beams , fins, facias and similar items as per manufacturers instruction average thickness not exc 40 mm complete all as specified.
M & L for guniting/ short crating of RCC columns, beams , fins, facias and similar items as per manufacturers instruction average thickness not exc 25 mm complete all as specified.
M&L for applying three coats of white wash on ceiling including preparation of newly plastered surfaces complete all as specified .
M&L for applying one coat of white wash on ceiling including preparation of old treated surfaces complete all as specified .
M & L for Preparation of old surfaces of walls and applying two coats of distemper oil emulsion with 3 mm thick wall putty over and including a coat of alkali resistance primer including complete removal of existing treatment complete all as specified.
M & L for Preparation of new surfaces of walls and applying two coats of distemper oil emulsion with 3 mm thick wall putty over and including a coat of alkali resistance primer complete all as specified.
M & L for Complete removal of existing treatment of old wall by any description preparation of surfaces by mechanised sander having suction vacuum bag using smart periodical methodology complete all as specified and applying the following:- (a) Applying wall care putty in two coats ( each coat 2 mm thick) on wall surfaces & smoothening the surfaces with sand papers mechanised sanding etc (Preparatory to paint as directed) complete all as specified. (b) Two coats of exterior acrlic emulsion by using airless spray/ roller over and including a coat of acrlic emulsion external primer complete all as specified
M & L for Preparation of new plastered surfaces complete all as specified and applying the following:- (a) Applying wall care putty in two coats ( each coat 2 mm thick) on wall surfaces & smoothening the surfaces with sand papers mechanised sanding etc (Preparatory to paint as directed) complete all as specified. (b) Two coats of exterior acrlic emulsion by using airless spray/ roller over and including a coat of acrlic emulsion external primer complete all as specified. Note :- Contractor may use manual scrapping tools for complete removal and surfaces preparation with prior approval of Engr -in-Charge in case using of mechanical equipments are not possible.
M & L for complete removal of existing treatment and applying two coats of plastic emulsion paint ( interior emulsion) of approved tint/ colour after preparation of surface complete all as specified.
M & L for preparation of new surfaces including applying 3 mm thick wall putty and applying two coats of plastic emulsion paint ( interior emulsion) of approved tint/ colour complete all as specified.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified.
M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6) complete all as specified and directed.
M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:6) complete all as specified and directed.
Taking down chowkats or frames with shutters of any type and specification (without taking off shutters from the frame) not exc 1.5 sqm each and removal from site of work complete all as specified.
Taking down chowkats or frames with shutters of any type and specification (without taking off shutters from the frame) exc 1.5 sqm but n. exc 4 Sqm each and removal from site of work complete all as specified.
Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each and removal from site of work complete all as specified..
Taking dow & refixing the same opening shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each complete all as specified.
S&F factory made pressed steel frames of frame size 105 mm x 60mm with one or more rebates including necessary fixing lugs, lock strike plate, SS Hevy duty 2.5 mm thick butt hinges etc, compete, all as specified.
S&F factory made second class hard wood plain, framed, panelled solid shutters (any number of panels), 35mm thick, with panels of timber flat on both sides (feather edges), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats.
S & F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified in Preamble 8B.3.1 of SSR Part -II (2020) and all as shown on drawing of SSR Part-II (2020).
S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement all as per instruction and drawing shown for item No 8080 of SSR Part II.
S & F butt hinges, stainless steel heavy duty 125 mm long 2.5 mm thick complete all as specified .
S & F 125 mm long anodised aluminium handles, 'D' type complete all as specified.
S & F 150 mm long anodised aluminium handles, 'D' type complete all as specified.
S & F 200 mm long anodised aluminium barrel tower bolt complete all as specified.
S & F 150 mm long anodised aluminium barrel tower bolt complete all as specified.
S & F aluminium 250mm long, anodised aluminium sliding door bolt with hasp, staple (bolt type), and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified.
S & F factory made steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat primer complete all as specified..
S & F factory made steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including one shop coat primer complete all as specified..
S & F MS framed work such as grills, gratings, etc., with end of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified.
S & F sheet glass, 4mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified.
S & F galvanised steel wire cloth, 0.56 mm nominal dia of wire & average width of aperture 1.18mm and fixed with tinned tacked or galvanized steel wire staples complete.
M & L for preparation of new or previously untreated wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat of Pink primer complete all as specified.
M & L for preparation of new or previously untreated steel surfaces surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified.
M & L for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for.
M&L for applying evenly a coat of blown type bitumen @ 1.50 Kg / Sqm and blinding with clean dry sand @ 0.05 Cum /Sqm complete all as specified.
M&L polythene film, 150 micron thick, heavy duty, laid on a coat of bitumen primer @ 0.30 to 0.50 Kg/Sqm complete all as specified.
M & L for 30mm thick PCC (1:2:4) type B0 using 12.5 mm graded stone aggregate with using water proofing compound as per manufacturer's instruction as in sunken floor all as specified.. (Note :- WP Materials shall be measured and paid for separately.)
M & L for rendering 15 mm thick in cement mortar (1:4) in sunken floor finishing even & smooth with using water proofing compound complete all as specified.(Note :- WP Materials shall be measured and paid for separately.)
M & L for PCC (1:5:10) type E-2 using 40 mm graded stone aggregate as in sub base of floor mass filling as in sunken floor complete all as specified.
M&L for 100 mm dia cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1 complete all as specified.
Dismantling of cast iron pipes of any dia and any description including all fittings complete all as specified.
M & L 100 mm dia (spun type ) cast iron soil waste & vent pipe drain pipes fixed to wall incl all fittings, jointed in cement mortar including taking out old pipes, if required.
M & L 75 mm dia (spun type ) cast iron soil waste & vent pipe drain pipes fixed to wall incl all fittings, jointed in cement mortar including taking out old pipes, if required.
S&F factory made powder coated standared aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. (minimum thickness of powder coating shall be 50 micron)
S&F factory made powder coated anodised aluminium door shutters, aluminium sections weighing not less than 1.10 kg/metre including necessary joining cleats, glazing clips, rubber neoprene packing, handle 2 Nos 150 mm long and hinges 100 mm size 03 Nos in each shutter, including anodised aluminium snap beading, screws etc complete all as specified.
S & F three track aluminium powder coated sliding windows using two tracks for glazed window shutter and one track for wire gauged shutter including provision of necessary rubber gasket fixing glass panes/ wire mesh etc. complete all as shown in drawing No. CE BT/SK-936 R Sheet 1/1. Note :- Glass panes & wire mesh shall be measured and paid for separately under respective schedule.
S&F factory made powder coated anodised aluminium window and ventilator shutters, (Power coating of any colour, thickness of powder coating not les than 50 micron) fixed type without sash bar, aluminium sections weighing not less than 1.10 kg/metre including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws etc complete all as specified.
S & F aluminium anodised snap grid frame work 605mm x 605mm for false ceiling comprising of main / cross tee / wall angle weighing not less than 0.36 Kg/RM to be fixed to ceiling with 6mm dia GI wire supporting hanger upto 1200mm length adjusting level fixed to roof slab at 600 mm c/c by means of 'J' bolt with necessary bolt , nuts and washers or expansion hold fasteners 12.5mm dia and 40 mm long as per manufacturer’s instruction including M & L for 12 mm tapered edge gypsum board of size 600 x 600mm (conforming to IS-2095-1982) shall be fixed to ceiling section with 25 mm dia wall screws at 230 mm centre to centre , screw fixing shall be done mechanically either with screw driver or drilling machine with suitable attachment and finally the boards shall be jointed and finished so as to have a flush look including dismantling of old false ceiling of any type / any size complete all as specified.
M & L for perforated prelaminated particle board/tiles for insulation and acoustic purposes, ISI marked, 60 x 60 cm in size with staples on snap and grid building boards fixed or laid / inserted to aluminium frame work with screws as in false ceiling fixed in ceiling flat or sloping complete all as specified.
S & F sheet glass, 4mm thick ordinary quality and glazing with aluminium beads in square exceeding 0.5 Sqm in each pane complete all as specified.
S&F Solar control film 25 micron reflective type ( greater sun control or equivalent) complete all as specified.
S & F in repairs door closer hydraulically regulated, designation No 3, universal type, aluminium (die cast) body, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed.
S & F in repairs vitreous china squatting pan, 'Orissa' pattern, size 580mm x 440mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. including making good to floor and excluding flushing cistern, flush pipe and waste pipe complete.
S & F in repairs PVC valveless, syphonic action type, flushing cistern, 10 liters capacity, low level, dual syphon and button system, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe 32mm dia upto 1250 mm long all as per Cat Part No FLS-WHT-5201C of Jaquar or equivalent Cat Part of make mentioned in Appendix 'B' complete.
S & F in repair PVC connections 15 mm bore, 600 mm length, heavy duty, with CP nuts complete all as specified.
Supply and fixig in repairs 6 mm thick mirror bevelled edges fixed to chromium plated screws complete all as specified and directed.
S & F 100 mm bore cast iron soil, waste and vent spun pipes in any length with or without ears fixed with chemical cement joints laid in trenches or in floor complete all as specified.
S & F 100mm dia cast iron traps 'P' or 'S' complete all as specified.
Taking up or down 15mm bore GI water tubing and fitting including segregating of serviceable steel tubing and connection complete.
All as per ser item No. 111 here-in-before but pipe 20 mm bore
All as per ser item No. 111 here-in-before but pipe 25 mm bore
S & F GI water tubing medium grade, 15 mm bore ISI marked with all fittings and fixed to walls & ceiling or laid in floors complete all as specified
All as per ser item No. 114 here-in-before but pipe 20 mm bore
All as per ser item No. 114 here-in-before but pipe 25 mm bore
S & F GI water tubing light grade, 25 mm bore ISI marked as in over flow pipe with all fittings and fixed to walls & ceiling or laid in floors complete all as specified
S&F 15 mm bore chromium plated, fancy type, long body bib taps cast copper alloy with crutch or butterfly handle, screwed for iron pipe, or for brass ferrule as per Cat Part No CON-107KN of Jaquar or equivalent Cat Part of make mentioned in Appendix 'B'.
S & F in repairs angular stop valves, chromium plated, fancy type, quarter turn, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe complete all as specified.
S&F in repairs pillar taps, cast copper alloy, with capstan heads, fancy type, quarter turn, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe for 15mm bore dia of pipe.
S&F in repairs 20 mm bore dia brass ball valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified.
M & L in repairs for prelaminated particle board, 18/19 mm thick, exterior grade, ISI marked, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete.
S&F in repairs 40 mm width of flap (when open) Continuous (piano) hinges, mild steel, bright finish or electro galvanised complete all as specified.
S&F in repairs 125mm size Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified.
S & F in repairs floor door stopper 150mm of aluminium alloy body, and tongue, ISI marked, anodised, with hard drawn steel spring, fixed in floor complete all as specified.
S & F in repairs PTMT/ CP grating doom 125 mm dia with/ without waste hole (minimum weight 40 gms) complete all as specified.
M&L for granite (of any type) work 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
M & L for preparation of old painting surfaces of steel surface of any description, over 10 cm in width or girth, not otherwise described with one coat of synthetic enamel paint complete all as specified.
S&F in repairs sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm including 40mm waste fittings, brass chromium plated with long screwed shanks and flynuts, flange end bedded in red lead cement complete all as specified.
Dismantling water tank of capacity 500/1000 litres and removing to store.
S & F 1000 litres capacity Rotational moulded polyethylene in white colour, three layered, ISI marked, water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as directed.
S & F vitreous china wash hand basin, white, of size 450mm x 300mm , excluding waste, chain and plug and porcelain stopper but including 32 mm dia waste coupling fancy type chromium plated ,and PVC waste pipe of 32 mm dia and fixed all as directed complete, .
M & L for providing and injecting chemical emulsion for post constructional anti-termite treatment of soil under existing floors using emulsion @ 1.00 litre per hole, 300mm apart including drilling and plugging 12mm dia holes with CM (1:2) (1 cement : 2 coarse sand) to match the existing floors.
M & L for providing and injecting chemical emulsion for post constructional anti-termite treatment along external wall below concrete or masonry apron using chemical emulsion @ 2.25 liters per linear meter including drilling and plugging holes etc in apron.
S & F vierous china urinal flat back size 315 x 300 x 545 mm white with grating and union for discharge pipe, 32 mm dia flush pipe including providing and fixing plugs, beding urinal against wall in CM (1:2) securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement mortar complete all as specified.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards / slabs / blankets, any thickness, including cover fillets.
M & L for double layer POP false ceiling of approved design complete all as specification.
S & F in repairs vitreous china wash down EWC (pedestal Pattern) , white, including connection to drain or outgoing pipe , and to flushing pipe, anti-syphonage pipe, etc. including making good to floor and excluding flushing cistern, flush pipe and waste pipe all as specified.
S&F in repairs plastic water closet seat cover black or white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified.
S & F in repair wash basin, Vitreous China wall hung basin with pedestal and cupling all fittings size 590x 490x185 mm including cutting for and pinning in ends of brackets or erecting. Make Jaguar Cat Part No. LYS-WHT-38801 Vol 15A
S & F in repair Vitreous China wash down water closet pan (pedestal pattern) single piece WC with UF soft close seat cover hinges fixing accessories set and accessories set size 365x655x760 mm. Make Jaguar Cat Part No. LYS-WHT-38853S. Vol 15A
S&F vanishing blinds width of blinds size 100/150 mm colour approved by Engr-in-Charge.
S & F 15 mm bore wash basin mixer fancy type cast copper alloy chromium plated screwed down high pressure with or without lettered 'Hot' or Cold' with long screw shanks screwed for iron pipe or union complete. Make Jaguar.
S & F Health faucet with 8 mm dia 1.2 tr long flexible tube & wall hook with NRV (BLACK FLOW PREVENTER ) Make Jaguar
S & F Cromium towel ring Make Jaguar.
S & F Cromium plated toilet paper holder Make Jaguar.
S & F in repairs brass chromium plated tubular towel rail 20 mm dia 600 mm long, fixed complete all as specified and as directed. Make Jaguar
S&F in repairs 25mm dia drapery rod, stainless steel, chromium plated with fixing brackets, stops, rollers etc as in curtain rails. (Note : The cost of brackets and knobs is deemed to be including in the quoted unit rate. Nothing extra shall be paid on this account.)
S&F solid PVC wall lining consisting of 5 mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame including PVC beading on edges & top etc as per specification all as per specifications .
S&F 5 mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame all as per specifications.
M & L for grills and frame work of stainless steel with welding joins and design as pre requirements all as per specifications.
S & F in repairs , PVC (SWR) 110mm bore pipes, single socketed, in any length with rubber ring joints, fixed to walls (RWP) complete all as specified.
S & F in repairs health faucet brass body with wall hook and 1 metre SS pipe complete all as per Cera Cat part No. F8030301 or equivalent model of make mentioned in Appendix 'B' complete.
M & L for removal of apparent visible efflorescence first cleaned using hard wire brush and all crystal deposits to be removed, the bricks shall then be cleaned using soft brush of powdery crystals then make a 1:4 solution of vinegar and water ( 1 part vinegar to 4 parts water) and apply it to the efflorescence affected area using a nylon brush. Allow the vinegar/ water solution to sit on the surface of the affected area for 15 minutes, but do not allow the solution to dry and rinse the area with clean water using low pressure jet, Two cycles of cleaning using vinegar water solutions shall be repeated.
M & L for pointing of cleaned joints of bricks work with cement putty made at site using latex / SBR polymer diluted at ratio (1:4) with water. The solution so made shall be used to be mixed with cement to make a putty consistency paste and the cement puttty shall be then worked out in the joints which are clean and in SSD condition complete all as per manufactures instructions. (Make: Sika/ BASF/ FOSROC)
M & L for clearing of dust and deposte from pointed brick work by using brush. A undiluted single component acrylic polymer shall be used to prime the brick surface and the primer while being tacky the first coat of water proofing coating is done, second coat is applied after a time interval of 4 to 6 hrs after the first coat has dried, the water proofing coating shall be two component polymer modified cementatious coating having a thickness of 1.5mm in two coats. Note : (i) The material to be factory batched and ready to use. (ii) The two components shall be mixed using low speed drill having a RPM 350 to 450 and fitted with a paddle. (iii) The mixing to be done for 3 to 4 minutes to give a brushable consistency mix. (iv) The coating shall be done using 100 to 150 mm wide brush. (v) Care should be taken that the material while being used a agitated every 3 to 5 min to avoid powder part getting settled. (vi) The water proofing coating shall have below properties tensile strength of 4.56 N/mm2 at after 14 days exposure ( according to ASTM D 2370) bond strength 2.0 N/mm2 at+ 27 degree celcius (failure in substrate). (vii) After application of second coat and while the material is still wet, coarse sand is sprinkled over the coating so as to ensure proper mechanical key is provided for subsequent plaster. (Make: Sika/ BASF/ FOSROC)
M & L for 15 mm thick plastering in CM (1:4) with acrylic polymer on treated surface of brick work work with acrylic polymer @ 3% by weight of cement complete all as specified.
Taking out from trenches any size of cable all as specified and directed
Supply, laying, fixing or laid in trenches/ ducts/ through pipes/ in floors/ under roads/ hard standing / along poles and testing LT cable XLPE , PVC insulated screened bedded galvanised steel strip or wire armourd cable ( heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 240 Sqmm 3.5 core conforming to IS-7098 (Part-I) complete all as specified.
All as per ser item No. 159 here-in-before but size 150 sqmm, 3.5 core
All as per ser item No. 159 here-in-before but size 16 sqmm, 4 core
All as per ser item No. 159 here-in-before but size 10 sqmm, 4 core
All as per ser item No. 159 here-in-before but size 16 sqmm, 2 core
M & L for making the hole under road and hard standing not less than 1 metre depth and suitable for laying and inserting pipe upto 100 mm dia any length by mechanical drill system or Auger system and making the surface good as per existing surface insulator with aluminium binding complete. Note: GI tubing shall be measured and paid separately.
Supply and laying in replacement GI tubing, light grade, 100mm bore complete with all fittings for cable and earth continuity strip protection laid in trenches/fixed to poles/ along wall /under road/across the drain complete all as specified.
Supply and laying in replacement GI tubing, light grade, 40mm bore complete with all fittings for cable and earth continuity strip protection laid in trenches/fixed to poles/ along wall /under road/across the drain complete all as specified.
Supply, fabricating, installation, testing , commissioning and electrically connecting LT panel Board of size 120 cm x 120cm x 50cm, 415 volts, factory made, machine pressed, dust and vermin proof for out door type made with stainless steel sheet SS304 sheet 3 mm thick LT panel except inner sheath of 2 mm thick without powder coated machine pressed both side opening in two halves with rubber beading including aluminium bus bar of size 40mmX20mm( 1Amp=1Sqmm) capacity 4 strip mounted on porcelain insulator bus bar chamber, provided with inspection covers, each MCCB /cubical switch shall have independent opening, panel shall be mounted an angle iron frame and legs made from angle of size 40x40x5mm frame including lifting arrangement and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, grouted in PCC (1:2:4) type B-1 ( using 20 mm graded stone aggregate) complete including all connections /control wiring incoming/outgoing with suitable size of PVC insulated copper conductor cable 1100/650 volt grade comprising the following accessories including testing complete all as directed:-
MCCB 4 pole, 415 volts, 630 Amp rating with breaking capacity 65 KA, adjustable thermal setting 80-100% and magnetic setting 50 Hz Ics =100%Icu -01 (incoming) .
MCCB 4 pole, 415 volts, 400 Amp rating with breaking capacity 50 KA, adjustable thermal setting 80-100% and magnetic setting 50 Hz Ics =100%Icu -01 (out going) .
MCCB 4 pole, 415 volts, 250 Amp rating with breaking capacity 25 KA, adjustable thermal setting 80-100% and magnetic setting 50 Hz Ics =100%Icu -02 (out going) .
MCCB 4 pole, 415 volts, 160 Amp rating with breaking capacity 25 KA, adjustable thermal setting 80-100% and magnetic setting 50 Hz Ics =100%Icu -02 (out going) .
Spare pocket for fixing of 01 No MCCB with separate compartment-01 No.
Indicator lamp R,Y,B=01 Set of three
Supply, fabricating, installation, testing , commissioning and electrically connecting LT panel Board of size 120 cm x 120cm x 50cm, 415 volts, factory made, machine pressed, dust and vermin proof for out door type made with stainless steel sheet SS304 sheet 3 mm thick LT panel without coating both side opening in two halves with rubber beading including aluminium bus bar of 630 Amp capacity 4 strip mounted on porcelain insulator bus bar chamber, provided with inspection covers, each MCCB /cubical switch shall have independent opening, panel shall be mounted an angle iron frame and legs made from angle of size 40x40x5mm frame including lifting arrangement and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide zinc chromate embeding and grouted in PCC (1:2:4) type B-1 ( using 20 mm graded stone aggregate) complete including all connections /control wiring incoming/outgoing with suitable size of PVC insulated copper conductor cable 1100/650 volt grade comprising the following accessories including testing complete all as directed:-
MCCB 4 pole, 415 volts, 250 Amp rating with breaking capacity 25 KA, adjustable thermal setting 80-100% and magnetic setting 50 Hz Ics =100%Icu -01 (Incoming) .
MCCB 4 pole, 415 volts, 63 Amp rating with breaking capacity 25 KA, adjustable thermal setting 80-100% and magnetic setting 50 Hz Ics =100%Icu -06 Nos (out going) .
Spare pocket for fixing of 01 No MCCB with separate compartment-01 No.
Indicator lamp R,Y,B=01 Set of three
M & L for earthing complete with galvanized iron or steel earth plate electrode of size 60 cm x 60cm x 6.0mm thick buried directly in ground, vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below normal ground level surounded from all sides with alternate layers of charcoal and common salt and connected to GI earth strip 32 x 6 mm thick by means of GI bolts, nuts washers & check nuts and soldering the strip, electrode connected to panel board or on poles or on transformer (including making of test point with GI strip of size 32 x 6 mm) including GI protection pipe 40 mm bore light grade for protection of strip upto the extent of 7.5 mtr all as directed, GI pipe light grade 20 mm bore for watering including providing funnel and wire mesh, GI frame with suitably reinforced RCC pit cover, PCC chamber pit with PCC (1:3:6) type C2 using 40 mm graded stone aggregates complete including excavation and earth work in any type of strata , all as specified and shown in electrical plate No 3 of SSR-2009 Part - I, PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion and dismantling of old earthing.
Excavation in trenches not exceeding 1.5 mtr wide, and not exceeding 1.5 metre in depth in soft / loose soil for foundation, laying of cables or pipes (where provided) for protection of cable or fixing poles and stays and struts and including trimming of sides and forming bottom surfaces to required level complete all as directed.
Returning filling in, including spreading , leveling, watering and well ramming in layers each not exceeding 25cm thick in soft / loose soil complete all as specified and as directed.
Removal of surplus excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
M & L for local sand cushioning,230 mm thickness with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick before laying of cable and 150mm thick after laying of cable and punned down to 180mm after laying complete. Note:- Punned thickness shall be considered for payment purpose.
Supplying and laying PCC cable cover 300 x 180 x 40 mm , ISI marked, class LV Type -1.
Supply and laying Best quality, locally available, sub class 'B' bricks (Old size) for cable protection cover, laid flat and dry in trenches over the cable, perpendicular to the direction of cable complete.
S&F of LT cable junction box insulated and made out of polycarbonate with glass fiber reinforced and size shall not be less than 260 x 210 x 116mm, environment friendly, recyclable, halogen and silicon free, anti acid and anti corrosive, rated for degree of ingress protection IP 66 in accordance with IEC 60529, the gasket material shall be polyurethane and the gasket shall be internally embedded. Junction box shall be complies with requirements of the standards IEC 60998-1, IEC 60670-22 and IEC 60670-2-5 the JB colour shall be according to RAL 9011. The manufacturer of JB/ enclosure shall submit a copy of IEC certificate, for better safety of the polycarbonate, encl shall be fire retardant and self extinguishing in accordance with IEC 60695-2-11, DIN VDE 0304 part 3, UL subject 94 for flamability V-2. It should be tested and glove wire test for 96˚ centigrade. The impact strength of polycarbonate enclosures/ boards i.e the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08 Made of Hensel/ Siemens/ GE Power / Rittal. Mamunfacturer should submit routine test certificate for CJB/PJB complete all as specified and directed.
Supply and fixing PVC insulated stranded copper conductor cable sheathed 1.5 sqmm flat 3 core for connection for steet light fitting with over head lines/ service connection including heavy duty PVC conduit along Pole complete all as specified and directed.
Taking down carefully copper / aluminium point wiring (light, fan, socket ) complete with all accessories such as switches, ceiling roses, pendants, regulators, sockets etc fitted and removing dismantled material & making good disturbed surfaces of walls/ floor etc and matching with existing surface all as specified and directed.
M & L for point wiring using approved colour code as per IS (Red, Black and Green for single phase circuits) with multistrand copper conductor 1.5 Sqmm nominal cross sectional area single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked with valid CM/L No. drawn in existing concealed PVC rigid non metallic conduit, including replacement of modular sunken boxes and fixed concealed, covered with inner and outer cover for fixing of switches, sockets etc including PVC insulated multi-standed copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed at site for one light point controlled by one 5/6 Amp one way switch . Note Switch / socket and fan regulator shall be measured and paid separatly.
All as per ser item No. 194 here-in-before but one fan point 5 Amps one way switch with 1.5 Sqmm size.
All as per ser item No. 194 here-in-before but one Ex-fan point 5 Amps one way switch with 1.5 Sqmm size.
All as per ser item No. 194 here-in-before but for socket outlet 5 Pin, 5 Amp on same board complete all as specified.
All as per ser item No. 194 here-in-before but for socket outlet 5 Pin, 5 Amp on independent board complete all as specified.
All as per ser item No. 194 here-in-before but one 3/5 Pin socket outlet 15 Amps with 2.5 Sqmm and 2.5 sqmm earth continuity conductor on independent board complete all as specified.
All as per ser item No. 194 here-in-before but for bell/ buzzer point complete all as specified.
All as per ser item No. 194 here-in-before but for one light point controlled by two way switch complete all as specified.
M & L for point wiring using approved colour code as per IS (Red, Black and Green for single phase circuits) with multistrand copper conductor 1.5 Sqmm nominal cross sectional area single core, PVC insulated and unsheathed FRLS cable 1100 volts grade with multi standed copper conductor drawn through and including non mettalic PVC conduit ( medium grade) concealed in wall/ ceiling with and including 1.5 Sqmm single core PVC insulated , multistranded unsheathed , FRLS copper condutor cable as continuous earth continuity conductor ( Green colour) including modular metal flush box & modular cover plate with frame suitable matching colour of required module for mounting or housing switches, socket outlets, fan regulatrors, etc including blanking plates & all other fixing accessories for one light / fan/ exhaust fan point controlled by one 5/6 Amps switch and including cutting chases ( as required) and making good sufraces to match with adjoining surface complete all as specified.
All as per ser item No. 202 here-in-before but for socket outlet 5 Pin, 5 Amp on same board complete all as specified.
All as per ser item No. 202 here-in-before but for socket outlet 5 Pin, 5 Amp on independent board complete all as specified.
All as per ser item No. 202 here-in-before but for socket outlet 6 pin , 5/15 Amp multipurpose, 2 in 1 on independent board with 2.5 Sqmm cable & including 2.5 sqmm multi stranded FRLS copper earth wire to common earth complete all as specified.
All as per ser item No. 202 here-in-before but for bell/ buzzer point complete all as specified.
S & F for 6 Amps switch modular type , 230 volts, AC one way ISI marked complete all as specified.
S & F for 6 Amps switch modular type , 3 Pin , 230 volts, AC ISI marked complete all as specified.
S & F for 16 Amps switch modular type , 230 volts, AC ISI marked complete all as specified.
S & F for socket universal 6/16 Amps modular type, 230 volts, AC ISI marked complete all as specified.
S & F for 6 Amps switch modular type , 230 volts, AC two way ISI marked complete all as specified.
S & F for bell push 6 Amps one way modular type , 230 volts, AC, ISI marked complete all as specified.
S & F for fan regulator electronic step type (1-4), modular type , 230-240 volts, AC, complete all as specified.
S & F for ceiling rose, polycarbonate, isolated body complete all as specified.
S & F for bell, AC 230 volts single pole complete all as specified.
M & L for wall mounted LED batten fitting T-8, retro LED 1 x 20 watt, 6000 K min 100 lumen per watt, 4 ft complete with decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate environment friendly , energy efficient complete with all light fittings connections and exstruded aluminium heat sink provided for efficient heat dissipation & integrated electronic drive all as specified and directed .
S & F for wall mounted LED batten fitting T-8, retro LED 2 x 18/20 watt, 6000 K min 100 lumen per watt, 4 ft complete pre-wired including LED tube light, extruded heat sink provided for efficient heat dissipation and integrated electronic driver complete fitting and all other accessories fitting arrangement including electric connection connecting with using flexible wire twin core upto ceiling rose/ connector complete all as specified and directed .
S & F enviroment friendly energy efficient square surface mounted LED flate panel of capacity 18 watt, 6000 K fixture with PDC aluminium housing and PMMA diffuser to makes it arobust luminatire complete all as specified and directed .
M & L endura DL NEO Recess mounted pressure die-cast aluminium luminair in powder coated white finish in round porfile LED light 12 watt, 5700 K with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete all as specified and directed .
S&F recessed LED ceiling lite with wide light window for maximized glare free output suitable for 600x600mm and ceiling cutout 595x595mm modular grid/POP ceiling complete fitting with separate electronic driver and high brightness EDs 36 watt, (100 lumens per watt) , 6000K including connecting electric connection, complete all as specified.
S&F new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP 66 roadway luminair with high power LED of 25/35 watt toughened glass complete with GI bracket (01 No) MS clamps (02Nos) suitable for security light fitting fixing to wall/column & electrical connection to the light fitting providing 1.5 mtr long twin core round copper conductor cable of suitable size and testing compete all as specified.
M & L for LED mirror light fitting of 9/10 watt, 6000 K, complete ready to use in all respect and including taking down of existing fitting all as specified and directed.
M & L for energy saving environment friendly, long life, LED strip with adopter and connector including fixing accessories LEDs strip length not less 5 mtr green/ blue colour as per existing sample complete all as specified and directed.
M&L for sub main wiring with 2 single core cable 4 sqmm, 1100 volts grade PVC insulated unsheathed of copper multi standard conductor FRLSH cable with continuous copper earth conductor of size 4 sqmm, in existing PVC concealed / surface conduit including taking down old unserviceable sub main wiring complete all as specified.
M&L for sub main wiring with 2 single core cable 6 sqmm, 1100 volts grade PVC insulated unsheathed of copper multi standard conductor FRLSH cable with continuous copper earth conductor of size 4 sqmm, in existing PVC concealed / surface conduit including taking down old unserviceable sub main wiring complete all as specified.
M&L for sub main wiring with 2 single core cable 4 sqmm, 1100 volts grade PVC insulated unsheathed of copper multi standard conductor FRLSH cable with continuous copper earth conductor of size 4 sqmm, 1100 volts grade drawing through in & including existing PVC concealed / surface conduit of size 20 mm with concealed including cutting of chases on the wall surface complete all as specified.
M&L for sub main wiring with 2 single core cable 6 sqmm, 1100 volts grade PVC insulated unsheathed of copper multi standard conductor FRLSH cable with continuous copper earth conductor of size 6 sqmm, 1100 volts grade drawing through in & including existing PVC concealed / surface conduit of size 20 mm with concealed complete all as specified.
M&L for sub main wiring with 4 single core cable 16 sqmm, 1100 volts grade PVC insulated unsheathed of copper multi standard conductor FRLSH cable with continuous copper earth conductor of size 16 sqmm, 1100 volts grade drawing through in & including existing PVC concealed / surface conduit of size 25 mm with concealed including cutting of chases on the wall surface complete all as specified.
S & F single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 volts, AC supply including taking down old unserviceable DB complete all as specified.
S & F for LED engagement light 5 watt with Red & Green colour shade with fitting complete all as specified.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, concealed, surface mounting, acrylic door, IP-43 protection, flush mounted with metal door, powder coated 12 way, DB SPN 230 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old unserviceable DB complete all as specified.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, concealed, surface mounting, acrylic door, IP-43 protection, flush mounted with metal door, powder coated 8 way, DB SPN 230 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old unserviceable DB complete all as specified.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, concealed, surface mounting, acrylic door, IP-43 protection, flush mounted with metal door, powder coated , DB V TPN 4 way, 415 Volts,AC with 200 Amp rated bus bar, double door, dust and vermin proof suitable for incorporation of incoming MCCB and outgoing MCB SP/TP and earth & neutral bus bar etc including taking down old unserviceable MCCB, DB complete all as specified.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, concealed, surface mounting, acrylic door, IP-43 protection, flush mounted with metal door, powder coated , DB V TPN 6 way, 415 Volts,AC with 200 Amp rated bus bar, double door, dust and vermin proof suitable for incorporation of incoming MCCB and outgoing MCB SP/TP and earth & neutral bus bar etc including taking down old unserviceable MCCB, DB complete all as specified.
S & F MCCB 4 Pole of rating 63 Amps Icu 16 KA, thermal magnetic based complete all as specified.
S & F MCCB 4 Pole of rating 100 Amps Icu 16 KA, thermal magnetic based complete all as specified.
S & F MCB, SP, 40/63Amps, 'C' curve, ISI marked, 230 Volts, AC supply, breaking capacity not less than 10 KA, 1 module including taking down old unserviceable MCB SP complete all as specified.
S & F MCB, SP, 6 to 32 Amps, 'C' curve, ISI marked, 230 Volts, AC supply, breaking capacity not less than 10 KA, 1 module including taking down old unserviceable MCB SP complete all as specified.
S & F MCB, SPN, 32/40 Amps, 'C' curve, ISI marked, 230 Volts, 50 Hz AC supply, breaking capacity not less than 10 KA,incl necessary attachment including taking down old unserviceable MCB SPN complete all as specified.
S & F MCB, SPN, 63 Amps, including taking down old unserviceable MCB SPN complete all as specified.
M & L for taking down carefully serviceable ceiling fans or exhaust fans and keep in safe custudy. After completing the building repair work refixing/ handing the ceiling fan and to be done new painting as per existing colour all as directed including electric connection with new flexible copper wire from ceiling rose/ connector to fan connector complete all as specified.
S & F Exhaust fan plastic body 250mm sweep single phase 230V, 50 Hz, 1400 RPM complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated sheathed copper conductor flexible cable 24/0.2 mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement bortar 1:4 white washing matching with existing colour etc complete all as specified.
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia light grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note :- (a) PCC chamber shall be constructed at least 1.5 m away from earth pit. Pipe for watering shall be provided in slanting manner. (b) 4mm dia GI wire and 15mm dia light grade GI protection pipe upto 7.5 metre shall deemed to be included in quoted rate.
S & F rigid non-metallic PVC conduit medium grade ISI marked of 40 mm dia including cutting of chases on the wall surface wall to conceal the PVC conduit and making ood the disturbed surfaces of wall including all accessories such as tees, bends, junction boxes, PVC round plates, reducers, ball mouth tube ends and couplers, lock nuts, saddles , pipe hoods etc in and including drawing the exposed telephone and LAN wires of any size through the concealed conduit complete all as specified.
S & F rigid non-metallic PVC conduit medium grade ISI marked of 25 mm dia including cutting of chases on the wall surface wall to conceal the PVC conduit and making ood the disturbed surfaces of wall including all accessories such as tees, bends, junction boxes, PVC round plates, reducers, ball mouth tube ends and couplers, lock nuts, saddles , pipe hoods etc in and including drawing the exposed telephone and LAN wires of any size through the concealed conduit complete all as specified.
S & F rigid non-metallic PVC conduit medium grade ISI marked of 20 mm dia including cutting of chases on the wall surface wall to conceal the PVC conduit and making ood the disturbed surfaces of wall including all accessories such as tees, bends, junction boxes, PVC round plates, reducers, ball mouth tube ends and couplers, lock nuts, saddles , pipe hoods etc in and including drawing the exposed telephone and LAN wires of any size through the concealed conduit complete all as specified.
M & L for sub main wiring complete with 2 single core 1.5 Sqmm 1100 volts grade PVC insulated multi standed copper conductor cable FRLSH with continuous copper earth conductor of 2 single core 1.5 Sqmm in and including PVC conduit of size 25 mm including cutting of chases on wall and making good the disturbed surface complete all as specified. Note :- Sub main for engagement light.
NAVIN KUMAR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .