Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-Finance | L1 | Accepted-Finance Lowest | |
| 2 | L2₹30.3 L+₹2.5 L (8.83%)Accepted-Finance | L2 | Accepted-Finance Other than lowest | |
| 3 | L3₹32.0 L+₹4.2 L (15.0%)Accepted-Finance HOUSE NO 599 D SURYA NAGAR PHASE II SECTOR 91 FARIDABAD 121013 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121013 | L3 | Accepted-Finance Other than lowest | |
| 4 | L4₹34.7 L+₹6.9 L (24.6%)Accepted-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Accepted-Finance Other than lowest | |
| 5 | L5₹42.7 L+₹14.8 L (53.0%)Accepted-Finance | L5 | Accepted-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (U) Chandimandir
GE (U) Chandimandir Chandimandir Cantt Panchkula (HR)
GE(U)/CHM-24/2021-22 - PROVN OF REPAIRS/MAINTENANCE CUM PREVENTIVE MAINTENANCE OF APFC PANELS INSTALLED AT VARIOUS E/M INSTALLATIONS AT CHANDIMANDIR CANTT
2021_MES_458328_2
GE(U)/CHM-24/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandimandir Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (U) Chandimandir
₹80,000
Yes
6 Sept 2021
23 Jul 2021
28 Aug 2021
23 Jul 2021
21 Aug 2021
30 Jul 2021
60 days
Amount
Taking down old APFC panel and Supply, installation, testing and commissioning of 175 kVAr new APFC panel totally enclosed, metal clad, sheet steel fabricated, fixed feeder type, dust and vermin proof, free standing , floor mounting type, pre treated as per 9 tank process and finished with powder coating of shade RAL 7032, factory OEM or authorised TTA franchise, be as per IEC 61439 & IEC 61921, rated system voltage 440 volt, short circuit rating more than 35 KA, altitude 1000 m, ambient temperature -5 degree C to 45 degree C, power supply 3 phase 4 line , relay current input signal 5A from CT online, load bearing structure made of 2 mm sheet steel and the front door and partition are made of 1.6 mm thickness IP 42. The capacitor element used in unit shall be metallized polypropylene film having low loss dielectric impregnated with such impregnant, which shall have high dielectric constant , low viscosity and high chemical stability, operating temp of capacitor shall be 65 degree centigrade, capacitor shall have maximum operating loss of 0.45 W/ KVAR, capacitors shall have maximum 250 % overload current carrying capacity or rated current, maximum inrush current carrying capacity of capacitor bank shall be 350 times of capacitors bank rated current. The maximum switching life of capacitor banks shall be 1500 switching/ years complete with internal wiring of panel with coding system all as specified and directed by Engr-in- charge with and comprising of following accessories:- (A) Incoming :- (a) MCB 320 amp 36 KA with TM release, DN3B-400D - 01 Nos. (b) External rotary handle - 01. (c) Aux. 1 C/O + TAC 1 C/O - Right, for DU/DN2, DN3, DN4 dsine MCCB-Internal -01.
Taking down old APFC panel and Supply, installation, testing and commissioning of 150 kVAr new APFC panel totally enclosed, metal clad, sheet steel fabricated, fixed feeder type, dust and vermin proof, free standing , floor mounting type, pre treated as per 9 tank process and finished with powder coating of shade RAL 7032, factory OEM or authorised TTA franchise, be as per IEC 61439 & IEC 61921, rated system voltage 440 volt, short circuit rating more than 35 KA, altitude 1000 m, ambient temperature -5 degree C to 45 degree C, power supply 3 phase 4 line , relay current input signal 5A from CT online, load bearing structure made of 2 mm sheet steel and the front door and partition are made of 1.6 mm thickness IP 42, capacitor element used in unit shall be metallized polypropylene film having low loss dielectric impregnated with such impregnant, which shall have high dielectric constant , low viscosity and high chemical stability, operating temp of capacitor shall be 65 degree centigrade, capacitor shall have maximum operating loss of 0.45 W/ KVAR,capacitors shall have miximum 250 % overload current carrying capacity or rated current, maximum inrush current carrying capacity of capacitor bank shall be 350 times of capacitors bank rated current, maximum switching life of capacitor banks shall be 1500 switching/ years complete with internal wiring of panel with coding system all as specified and directed by Engr-in- charge with and comprising of following accessories:-
Taking down old unserviceable ACB any type and Supply, installation testing and commissioning new LT ACB of 800 415 Volts, 50 Hz, Amps four pole manual draw out microprocessor based, with LCD display with complete set of LSIG protection with self power release with fault indication and with 20 trip history with time stamping suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar /nut bolts/lugs complete all as specified and directed by Engr-in-charge. Make : ABB/Schnieder/L&T/Siemen
MCCB four pole 400Amps, 415 volts, 50HZ breaking capacity not less than 36 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics = 100% of Icu, in replacement (taking down old damaged MCCB) complete all as specified and as directed. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-4 here-in-above but of 320 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-4 here-in-above but of 250 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-4 here-in-above but of 200 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-4 here-in-above but of 160 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-4 here-in-above but of 125 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-4 here-in-above but of 100 Amps. Make : L&T/ABB/Schnieder/Siemens
Disconnecting and taking out old damaged/defective LT cable from ducts or taking down from poles or taking out from pipes below or above ground level, or for rerouting of cable aluminium conductor 1100 volts grade, size 70.00 sqmm, 3.5 core and removing unserviceable cable from site of work complete all as specified and as directed.
All as per the description of serial item-11 here-in-above but for of size 95.00 sqmm 3.5 core
All as per the description of serial item-11 here-in-above but of size 120.00 sqmm 3.50 core
All as per the description of serial item-11 here-in-above but for of size 185.00 sqmm 3.50 core
All as per the description of serial item-11 here-in-above but for of size 240.00 sqmm 3.5 core
All as per the description of serial item-11 here-in-above but of size 300.00 sqmm 3.50 core
All as per the description of serial item-11 here-in-above but for of size 400.00 sqmm 3.50 core
Supply, laying , jointing and testing LT underground electric cable XLPE insulated, PVC sheathed armoured heavy duty 1100 volts grade heavy duty multystranded aluminium conductor laid in ducts or passing through under road or fixed to poles or walls complete all as specifed and as directed of following size :-
Cross sectional area 70.00 sqmm 3.50 core
Cross sectional area 95.00 sqmm 3.50 core
Cross sectional area 120.00 sqmm 3.50 core
Cross sectional area 185.00 sqmm 3.50 core
Cross sectional area 240.00 sqmm 3.50 core
Cross sectional area 300.00 sqmm 3.50 core
Cross sectional area 400.00 sqmm 3.50 core
Phase indicator lamp, LED Type of colour red, blue and yellow (set of three), in replacement (taking down old lamp) complete all as specified and as directed
Indicator lamp,LED type of colour red/green, in replacement (taking down old lamp) complete all as specified and as directed
Lock for APFC panel rotary type with all accessories, as per existing (size and shape), in replacement (taking down old lock), complete all as specified andas directed .
Aluminium bus bar of different size and capacity, as per site requirement and as directed by Engineer-in-Charge including PVC insulating materials and cutting, welding as required, making holes and fixed in position in replacement (taking down old bus bar) complete all as specified and as directed.
Painting to existing APFC panel of size 1.20 m x0.80nx0.060m (avg) internally and externally with spray painting, two coats of synthitic enamel of shade and colour as approved by GE, including scapping down existing treatment completely and preparing the surfaces to the entire satisfaction of Engineer-in-Charge complete all as specified and as directed.
Electric panel door fabricated from mild steel sheet, as per existing size and shape, fixed / fitted by and with required no of hings of appropriate size, by properly welding and checking for proper opering and closing, in replacement (taking down old door/shutter) complete all as specified and as directed
APFC panel relay 8 steps, 415 volts, single CT input 1/5 Amps, in replacement (taking down old relay) complete all as specified and as directed. Make - L&T Cat part No CS909020000 or equivalent as approved by GE
APFC panel relay 12 steps, 415 volts, single CT input 1/5 Amps, in replacement (taking down old relay) complete all as specified and as directed. Make - L&T Cat part No CS909030000 or equivalent as approved by GE
APFC panel relay 14 steps, 415 volts, single CT input 1/5 Amps, in replacement (taking down old relay) complete all as specified and as directed. Make - L&T Cat part No CS909040000 or equivalent as approved by GE
Capacitor duty connector MO C8.5, 440 volts, 3 phase, 50 Hz, detaching type early make contacts separate termination for dumping resistors, encapsulated damping resistor assembly built in surge suppressor,low pick up VA consumption in replacement (taking down old capacitor) complete all as specified and as directed. Make : L&T- Cat Part No CS96320 or equivalent as approved by GE.
All as per the description of serial item 30 here-in-above but MOC12.5 -ditto- Make : L&T- Cat Part No CS96321 or equivalent as approved by GE
All as per the description of serial item 30 here-in-above but MOC15 -ditto- Make : L&T- Cat Part No CS90019 or equivalent as approved by GE
All as per the description of serial item 30 here-in-above but MOC 20 -ditto- Make : L&T- Cat Part No CS90021 or equivalent as approved by GE
All as per the description of serial item 30 here-in-above but MOC 25 -ditto- Make : L&T- Cat Part No CS96322 or equivalent as approved by GE
All as per the description of serial item 30 here-in-above but MOC 50 -ditto- Make : L&T- Cat Part No CS96324 or equivalent as approved by GE
Heavy duty capacitors cylindrical series 5KVAr rating, 440 Volt, in replacement (taking down old capacitor), complete all as specified and as directed. Make : L&T or equivalent as approved by GE.
All as per the description of serial item 36 here-in-above but 10 KVAr rating -ditto- Make : L&Tor equivalent as approved by GE.
All as per the description of serial item 36 here-in-above but 15 KVAr rating -ditto- Make : L&Tor equivalent as approved by GE.
All as per the description of serial item 36 here-in-above but 20 KVAr rating -ditto- Make : L&Tor equivalent as approved by GE
All as per the description of serial item 36 here-in-above but 25 KVAr rating -ditto- Make : L&Tor equivalent as approved by GE.
MNO connector, 22E, 415 volt in replacement (taking down old connector), complete all as specified and as directed. Make : L&T Cat Part No SS94667 or equivalent as approved by GE
MNO connector, 04E(4NC), 415 volt in replacement (taking down old connector), complete all as specified and as directed. Make : L&T Cat Part No SS94669 or equivalent as approved by GE
Complete internal wiring of 50 KVAr APFC panel parts naming relay, contactor, capacitor, ammeture, voltmeter with HRFR 1.5 Sqmm multistranded copper cable maintining proper coding of each circuit of contactor; voltmeter, indicator lamp, in replacement (taking down old wornout wiring) complete all as specified and as directed. Make of APFC panle : L&T
All as per the description of serial item 43 here-iin-above but of 75 KVAr APFC panle -ditto- Make aof APFC panel : L&T
All as per the description of serial item 43 here-iin-above but of 100 KVAr APFC panle -ditto- Make aof APFC panel : L&T
All as per the description of serial item 43 here-iin-above but of 125 KVAr APFC panle -ditto- Make aof APFC panel : L&T
All as per the description of serial item 43 here-iin-above but of 150 KVAr APFC panle -ditto- Make aof APFC panel : L&T
All as per the description of serial item 43 here-in-above but 200 KVAr rating -ditto- Make aof APFC panel : L&T
All as per the description of serial item 43 here-in-above but 250 KVAr rating -ditto- Make aof APFC panel : L&T
MCB 20 Amps, D curve, 3 pole, 415 volts, in replacement (taking down old MCB) complete all as specified and as directed. Make : L&T or equivalent as approved by GE
All as per the description of serial item 50 here-iin-above but of 32 Amps -ditto- Make : L&T or equivalent as approved by GE
All as per the description of serial item 50 here-iin-above but of 40 Amps -ditto- Make : L&T or equivalent as approved by GE
All as per the description of serial item 50 here-iin-above but of 63 Amps -ditto- Make : L&T or equivalent as approved by GE
Change over switch ON LOAD type, 415 volts, 50Hz, AC 4 pole in sheet steel enclosure, capacity 600 Amps rated current, manually operated conforming to IS:13947 or latest edition with high thermal and dynamic strenght to withstand short circuit current level of 80 KA rms, in replacement (taking down old change over switch) complete all as specified and as directed.
Removing wild grass vegetation, creeper etc around LT panel/transformer/poles, stay assembly, climbing upwards including cleaning bottom surfaces on ground of area not less than 1.00m x 1.00m including surface dressing n.exc 15cm deep in any type of soil and removing rubbish to outside mob lad complete all as directed.
Earthing complete with galvanized iron or steel plate electrode 600mm X600mm X 6.0 mm burried directly in ground vertially in a pit of depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth of not less than 1.50m below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to with and including GI/ Steel strip of size 32mmx6mm upto a length of 7.50 metre by means of bolts, nuts, check nuts & washers of galvanized iron /steel, earth strip protected by and including galvanized steel pipe light grade of bore 40 mm (internal dia) & connected to main control board / switch board or any other electrical equipment complete all as shown in electrical plate No : 3 MES SSR including necessary excavation & earth work, disposal of surplus soil not exceeding 50m, in any type of soil. (The rate also includes for cost of charcoal & salt in alternate layers of 15 cm thickness, 20 mm bore internal dia GI/steel pipe light grade) for watering, funnel, wire mesh, PCC chamber in cement concrete (1:3:6) type C-1, 40mm thick RCC(1:2:4) type B-0, reinforced with XPM of weight not less than 4.00 kg/Sqm and mild steel frame of angle 50mmx50mmx6mm and testing on competion including dismantling / taking out existing earthing and removing dismantling / taken out materials outside the defence land complete all as directed.
Note: Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit Revised in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
Vasudeva Trading Co.
unique power & control system
R D Bansal
Aziz Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .