| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹39.2 L+₹6.9 L (21.4%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹39.8 L+₹7.5 L (23.1%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹40.7 L+₹8.4 L (25.9%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹41.3 L+₹8.9 L (27.7%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
| Sl No | Description | Qty | Unit | Mahindra Electric Stores L1 | PURVA ELECTRICALS AND ENGINEERS L5 | SHREE VAIBHAV ELECTRICALS L2 | SKS Electricals L4 | Priyanka Power line L6 | Aziz Traders L7 | Adinath Technical Services L3 | AMAN ENGINEERING AND ELECTIRICALS WORKS L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying UG cable, pipe line, foundation of poles etc and getting out in soft / loose soil complete all as specified and directed. | 308.12 | Cum | 100 ₹30,812 Lowest | 500 ₹1,54,060 | 175 ₹53,921 | 190 ₹58,542.8 | 185 ₹57,002.2 | 180 ₹55,461.6 | 290 ₹89,354.8 | 175 ₹53,921 |
| 2.00 | Excavating in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying UG cable, pipe line, foundation of poles etc and getting out in hard / dense soil complete all as specified and directed. | 77.03 | Cum | 100 ₹7,703 Lowest | 500 ₹38,515 | 430 ₹33,122.9 | 230 ₹17,716.9 | 235 ₹18,102.05 | 440 ₹33,893.2 | 260 ₹20,027.8 | 436 ₹33,585.08 |
| 3.00 | Returning, filling, in soil incl spreading levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed by Engr-in-Charge. | 245 | Cum | 10 ₹2,450 Lowest | 200 ₹49,000 | 95 ₹23,275 | 70 ₹17,150 | 50 ₹12,250 | 100 ₹24,500 | 150 ₹36,750 | 110 ₹26,950 |
| 4.00 | Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified & dierected. | 140.15 | Cum | 10 ₹1,401.5 Lowest | 200 ₹28,030 | 115 ₹16,117.25 | 60 ₹8,409 | 65 ₹9,109.75 | 120 ₹16,818 | 110 ₹15,416.5 | 110 ₹15,416.5 |
| 5.00 | Material & Labour for riddled earth cushioning to under ground cable in trenches / existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.
Note:- Measurement shall be taken after gentling punning. | 115.55 | Cum | 900 ₹1,03,995 | 500 ₹57,775 | 125 ₹14,443.75 | 600 ₹69,330 | 1,475 ₹1,70,436.25 | 125 ₹14,443.75 | 90 ₹10,399.5 Lowest | 130 ₹15,021.5 |
| 6.00 | Material & Labour for Brick " class B "protection for under ground cable complete all as specified & directed . | 12.4 | PER 1000 | 8,000 ₹99,200 | 8,000 ₹99,200 | 10,400 ₹1,28,960 | 13,000 ₹1,61,200 | 9,700 ₹1,20,280 | 10,500 ₹1,30,200 | 2,500 ₹31,000 Lowest | 11,500 ₹1,42,600 |
| 7.00Supplying, laying, jointing, commissioning and testing in repair XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade confirming to IS-7098 (Part-I-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, pvc sleeve etc complete all as directed by Engr-in-Charge for following sizes:- Make :- Havells / Gloster / Finolex / Polycab | |||||||||||
| 7.01 | 10 Sqmm 2 Core | 240 | RM | 114 ₹27,360 | 230 ₹55,200 | 150 ₹36,000 | 110 ₹26,400 Lowest | 135 ₹32,400 | 160 ₹38,400 | 120 ₹28,800 | 190 ₹45,600 |
| 7.02 | 10 Sqmm 4 Core | 340 | RM | 138 ₹46,920 Lowest | 380 ₹1,29,200 | 218 ₹74,120 | 175 ₹59,500 | 175 ₹59,500 | 225 ₹76,500 | 160 ₹54,400 | 200 ₹68,000 |
| 7.03 | 16 Sqmm 4 Core | 200 | RM | 178 ₹35,600 | 480 ₹96,000 | 294 ₹58,800 | 210 ₹42,000 | 195 ₹39,000 | 300 ₹60,000 | 128 ₹25,600 Lowest | 290 ₹58,000 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
25 Jul 2025, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REPAIR AND MAINTENANCE OF STREET LIGHT SECURITY LIGHTS GARDEN LIGHTS HIGH MAST LIGHTS AND ITS CONNECTED WORK AT MD AND OTM ACCN AREA OF AUNDH MIL STN UNDER GE MH AND RH KHADKI
2025_MES_718629_1
8709/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹90,000
Yes
6 Oct 2025
4 Jul 2025
28 Jul 2025
4 Jul 2025
25 Jul 2025
19 Jul 2025
4 Jul 2025 - 25 Jul 2025
Amount
Excavating in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying UG cable, pipe line, foundation of poles etc and getting out in soft / loose soil complete all as specified and directed.
Excavating in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying UG cable, pipe line, foundation of poles etc and getting out in hard / dense soil complete all as specified and directed.
Returning, filling, in soil incl spreading levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified & dierected.
Material & Labour for riddled earth cushioning to under ground cable in trenches / existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. Note:- Measurement shall be taken after gentling punning.
Material & Labour for Brick " class B "protection for under ground cable complete all as specified & directed .
Supplying, laying, jointing, commissioning and testing in repair XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade confirming to IS-7098 (Part-I-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, pvc sleeve etc complete all as directed by Engr-in-Charge for following sizes:- Make :- Havells / Gloster / Finolex / Polycab
10 Sqmm 2 Core
10 Sqmm 4 Core
16 Sqmm 4 Core
25 Sqmm 3.5 Core
35 Sqmm 3.5 Core
50 Sqmm 3.5 Core
Supply and errect in vertical position Steel tubular swaged poles in repair, type 410 SP- 31 (09 mtr long) with 300mm x 300mmx6mm mild steel plate continiusly welded to pole, final taper plug, bolts,nuts and screws and making holes as per requirement all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embeded portion and applying one coat fo red oxide primer, making 05 Nos strip each 30 cm high with super enamel paint ( Black and yellow) from ground level / coping upto 1.5 meter, painting with two coats of aluminium paint for the remaning height complete all as specified and directed. Note :- PCC in foundation, copping, excavation and earth work shall be measured and paid separately under relevent items of sch.
Supply & fixing ACSR conductor incl jointing with existing size of conductor and stringing on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection complete all as specified & directed
Supply & fixing rigid PVC line separator suitable for 2 wire, made from high grade PVC material, but phase to phase 300mm, suitable for use with 1100 volts grade complete all as specified & directed. Make- Shree Balaji Power Plast/Goyal Power Plast
Supply & fixing pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade complete all as specified & directed
Supply & fixing in repair light grade GI pipe of size 80 mm dia conforming to IS 1239 (Part-1): 2004 laid in trenchs under floors or fixed on pole for cable protection complete all as specified and directed by Engr - in - Charge.
Supply & fixing in repair light grade GI pipe of size 40 mm dia conforming to IS 1239 (Part-1): 2004 laid in trenchs or under floors or fixed on pole for cable protection complete all as specified and directed by Engr - in - Charge.
Material and labour for Earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES schedule Part-I and incl 40 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete all as specified & directed Note : Rate of item is deemed to be included for excavation in hard rock, by compressor machine to achieve required depth.
Material & Labour for detection of street light cable fault with and including technician, cable fault location inachive kit at AUNDH MIL CAMP( MD and OTM Accn) detect the cable fault, incl necessary excavation of soil / road, hard standing, foot path and refilling the soil, after jointing the faulty cable with new straight through joint kit, testing of cable complete all as specified & directed Note: Cable joint of required size shall be measured and paid separately under relevant item of this BOQ as Supply & fixing .
Supply and fix joint, heat shrinkable type straight through joints for joint LT UG cable 1100 volts grade of size 6 to 16 sqmm, 4 core, complete all as specified & directed
Supply and fix joint heat shrinkable type straight through joints for joint LT UG Cable 1100 volts grade of size 25 to 50 sqmm, 4/3.5 core, complete all as specified & directed
Taking down old unserviceable CT coil and Supply & fixing CT coil up to 5 A capacity complete all as specified & directed by Engr-in-Charge.
Supply and fixing in repair MCB, 4 pole 'B' curve, 63 amps, complete all as specified and directedby Engr-in-charge.
Supply and fixing of MCB, single pole,current carrying capacity 6 to 32 Amps, 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and , in the MCB DB/SMC Junction Box Complete with connection testing and commissioning complete all as specified and directed by Engr-in-charge.
Material & Labour for trimming of branches of trees with in 1.5 mtr on either side of the electric lines/poles with suitable T & P and disposing the waste complete all as specified and directed. Note : Measurement for triming of tree branches shall be measured once only for entire period of completion.
Material & Labour for road cutting / foot path and making good with PCC M-10 grade (nominal mix) using 40 mm graded stone aggregate of 150mm X 100mm inrespect of width and thickness complete all as specified and directed.
Supply and fix brass terminal of capacity 100Amp 4 pole complete with nut, bolts, washer, complete with backlite/ fibre insulator complete including fixing inside street light junction box complete all as specified and directed .
Supply and fix indicator lamp LED type R,Y,B &G complete all as specified and directed.
Supply and Fix in repair LED Street light fitting of 100 Watt (Cool White) including LED lens complete with body robust, corrosion resistant, superior finish, made up of high pressure die cast aluminium alloy housing. The luminaries shall be totally enclosed, dust and water proof with minimum IP - 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 to 300 V, AC, frequency 50 to 60 Hz, P.F should be more than 0.95 with Total Harmonic Distoration THD(I) less than 10% , cool white colour and lamp starting time should not be more than 10 second fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection . The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including provision of connection for street light from pole box with 2.5 Sqmm PVC insulated stranded copper conductor FRLSH cable (upto the lenght of 9 mtr) complete all as specified and directed by Engineer-in- charge. Make :- CROMPTON / HALONIX /BENLO
Ditto item no 25 above but of 60 Watt Make:- CROMPTON/ HALONIX /BENLO
Ditto item no 25 above but of 45 Watt Make:- CROMPTON / HALONIX /BENLO
Supply and Fix in repair Inverter LED Street light fitting of 90 Watt including LED lens complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy having inbuilt battery back-up for upto 2 hrs with auto ON/OFF.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest ammendments and input voltage range 140 to 300 V, AC, frequency 50 to 60 Hz ,P.F should be more than 0.95 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second fitting should be provided with 10 KV surge protection. Driver should also have double phase protection,no load , open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degree Centrigrade to 60 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 66 degree protection. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report complete all as specified and directed by Engineer-in- charge. Make :- HALONIX /BENLO/CROMPTON/JAQUAR
Supply & fixing in repairs Bracket for fixing of street light fittings bend to shape, made out of 40 mm dia GI pipe medium grade upto 1.5 mtr long fixed with two sets of MS clamps made out of flat iron of size 50x6 mm fabricated to shape and fixed with nuts bolts and washers & two coats of aluminium paints over and including a coat of red oxide primer complete all as specified and directed by Engr-in-Charge (Note : MS clamps, nuts, bolt and washer shall be measured seperately under relevant item)
Material & Labour repairing of street light fitting/luminaries of any size/type control wiring including replacement of LED drivers 45/60/90 W, fittings of any type and capacity, checking the continuity from pole to pole junction boxes complete all as specified & directed by Engr-in-charge. Note: (i) Driver shall be measured and paid separately as supply only. (ii) Make / capacity shall be same as of existing driver.
Supply only LED drivers suitable for extsting street light /flood LED fitting of any capacity & make upto 200W fitting on pole complete all as specified and directed.
Supply and Fix in repair LED Flood light fitting of capacity 120 watts made up of pressure die cast aluminium housing with toughned glass and high power LED's and secondary lenses, having system efficiency greater than 110 lumen per watts with surge protection device included. The luminaries shall be totally enclosed dust and water proof with minimum IP -66 protection pre wired up to connector including 2.5 sq mm PVC insulated cable for making connection (upto 9 mtr length), complete all as specified and directed by Engr-in-charge. Make :- Halonix/Crompton/Havells/Philips.
ditto- all as per item no -32 but of capacity 150 watts
ditto- all as per item no -32 but of capacity 200 watts
Supply and fix sheet moulding compound(SMC) Junction box size 155 x 210 x 92 mm inner dimension, Hinged door IP66 Protection, including three phase 100 Amps 4 pole baklite terminals with 3 Nos cable gland for street lights control mounted on pole with the provision of cable entry and exit complete all as specified and as directed. Make: Sintex / L & T / Hensel Cat No. DK1600G or techno commercial equivalent make
Dismantling unserviceable time & switch and Supply & fixing Analog time & switch with 150 hrs of battery backup working on 240 Volts AC supply complete all as specified and as directed. Make: L & T/Havells/Legrand
Supply & fixing in repairs contactor 4 pole 63 Amps capacity 415 Volts AC supply complete with 2 Nos auxilary contact No 2NC complete all as specified and as directed. Make:L & T/Havells/Legrand
Material & Labour for repair to pole coping with PCC M-10 grade (nominal mix) using 20 mm graded stone aggregrate, rendering 10 mm thick in CM 1:4 with using extra cement & applying one coat of white wash complete all as specified and as directed.
Material & Labour for checking the solar light , charging of batteries, cleaning the surface of the solar panel, terminals etc and maintaining the serviceability throughout the period of contract complete all as specified and as directed
Supply and replace DC Charging with control unit for solar street light panel complete all as specified & directed
Supply and replace high efficiency solar street light panel of capacity 110W complete all as specified & directed
Supply and replace batteries of solar street light of cap 54/60 AH , 12/12.8 volts high efficiency for solar street light 20/30 Watts complete all as specified & directed. Make: Exide/Amaron/Tata.
Supply and replace GI tube of size 80 mm bore, medium grade 6 Mtr long for solar street light complete all as specified & directed
Material & Labour for painting of solar street light poles with two coats of aluminium paint including preparation of old steel surfaces complete all as specified & directed.
Supply & fixing in repair LED bollard light, with aluminium housing with acrylic diffuser of cap 10/15 W inverted pyramid tripod type LED bollard with soft 360 degree light distribution with IP 65/66 protection, bollard length should be 800mm complete with all accessories complete all as specified and directed. Make :- Crompton cat no LBLSN-10-CDL or equivalent in Halonex/Wipro/Surya. Note :- The quoted rates is inclusive of excavation and foundation work of Pcc of bollard fittings as recommended by OEM and Engr- in- Charge.
Supply & fixing in repair LED post top lantern 40W aluminium housing, with IP 65/66 protection, clear acrylic diffuser, die cast aluminium spigot , spun aluminium powder coated top cover complete with accessoires with suitable size 40/50/60 mm outer dia GI pipe and plastering work wherever reqd complete all as specified & directed. Make :- Halonix cat no HLPT-04-40-CW or equivalent in Crompton/ Wipro/Surya.
Material & Labour for preparing old painted steel surfaces and applying two coats of aluminium paint to 9/11 mtr long steel tubular street light poles complete with connected fittings such as brackets and writing the pole number with black enamelled paint of 25mm high letters on 10 cm dia circle in white paint complete all as specified & directed.
Supply & fixing three core PVC insulated and FR PVC round sheathed, copper conductor 1100 volts grade cable of size 1.5 sqmm (multi stranded) complete all as specified and directed by Engr-in-charge.
Material & Labour for PCC M-10 grade (nominal mix) using 40mm graded stone aggregrate as in foundation for filling in, mass concrete for foundation of pole, transformer, panel board, stay, post top lantern, repairs to road cutting, drain path etc complete all as specified and as directed.
Taking down old LED strip of any type from poles and boards and Supply and fix decorative type Tri colour LED strip, out door type of 18mtr length with connection service wire of required length at poles and boards of various locations of DGQA complex, complete all as specified and directed by Engr-in-charge. Note: (i) The rates are inclusive of service wire for connection from nearby pole/panel of required length upto 10 mtr distance. (ii) Quoted rates is inclusive of T&P required for doing the complete job from height upto 18 mtrs.
Material & Labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Taking down unserviceable street light panel and Supply, install, commissioning and testing of street light panel outdoor type 415 V/440 Volts of size not less then 0.6x0.6x.03 meter, confirming to IEC 61439 with IP-54 protection of suitable size made out of 3.15 mm thick CRCA sheet with locking arrangement and complete panel should be powder coated with having neoprene rubber gasket for sealing door, doors of the panel should be removable type, 3 ph indicators lamp etc with provision for 02 Nos of 2 Pole 32 Amp MCB out going, 01 No Incoming TPN 63Amp with Analog street light timer cat No AUTS02AST00 of L&T, copper panel control wiring as per IS direction,make internal compartment for mounting MCBs, the panel shall be mounting on 50 x 50 x 6 mm MS angle iron and 60 cm above the normal ground level & embedded 20 cm below ground level in PCC foundation (1:2:4) type B 1 (20mm graded stone aggregate), connect new UG cable for Incoming from LT panel cable shall enter through cable glands for safety of cable where enter through panel complete all as specified and directed by Engr-in-charge.
SHREE VAIBHAV ELECTRICALS (BID ID -3370721)
Adinath Technical Services (BID ID -3370959)
SKS Electricals (BID ID -3370831)
PURVA ELECTRICALS AND ENGINEERS (BID ID -3370682)
Priyanka Power line (BID ID -3371490)
Aziz Traders (BID ID -3371161)
AMAN ENGINEERING AND ELECTIRICALS WORKS (BID ID -3371505)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .