Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹41.3 L
EMD Value
₹82,500
Closing Date
30 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
63 days
Expenditure
Capital (Works)
WORKS
11 conditions · 8 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1) Tenderer should attach self attested copy of PAN CARD and photo identification in support of their Identity. 2) The documents attached to the tender document should be clear and legible for evaluation of tenders. Proper care to be taken in this regard
A copy of document to be uploaded containing the following details: Name of the tenderer/ contractor, Validity of DSC, Complete address with pincode, Contact No.
Scanned copy of PAN card has to be enclosed
Scanned copy of TIN card has to be enclosed
A copy of NEFT form duly filled in the details as necessary along with a cancelled Cheque to be uploaded. (The tenderer/ contractor not having NEFT form may down load the empty NEFT form available in documents site)
Information/ certificates required as per Tender document for partnership deed, Article of association, MOU, JV AGREEMENT, Proprietary firm etc.
Self Attested copy of Experience Certificate of Previous Work Done -The bidder should submit documents related to completed/on-going similar service contracts during the last three previous financial years and the current financial year along with the details of payments received and percentage penalties imposed therein, to classify the completed/ on-going similar service contracts.
For materials of purchase value Rs.5 lakhs and above, inspection shall be done by third party i.e. M/s. RITES and all expenditure in connection with the inspection shall be borne by thetenderer/Contractor (5) For ISI marked products, if the order is placed on ISI certified manufacturers, the materials can be accepted on firm's WTC
Chennai Division-Electrical arrangements for various works as per (List of Works Enclosed)
ME-29-II-1110-2026~SR
ME-29-II-1110-2026
Open
Works - General
120 Days
Chennai, Tamil Nadu
₹0
₹82,500
9 Nov 2026
9 Nov 2026
16 Nov 2026
122 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 41,26,907 | ||
| — | — | — | Above/ 401955.00 Below/P | ||
| a)Excavation of Cable trench in all kinds of soils duly removing all obstructions in the way of cable trench, dumping at embankment site within railway land complete as per specification enclosed and in a manner as directed by the Section Engineer in charge at site. NOTE: The Section Engineer, in charge at site, will indicate the route of cable trench. b)Re-filling of trench with excavated earth, ramming, consolidation and bringing back the surface to original condition complete in a manner as directed by the Section Engineer in charge at site. | — | 1905.00 | — | — | |
| — | — | — | Above/ 87840.00 Below/P | ||
| Demolishing plain cement concrete in platform or elsewhere, disposal of material atleast 6m away from track centre within railway land by saw cutting/breaker as per site conditions to avoid any damage to nearby site complete in a manner as directed by the Section Engineer in charge at site. | — | 180.00 | — | — | |
| — | — | — | Above/ 1007280.00 Below/P | ||
| Supply and provision of mass concrete for platforms or elsewhere with 1:2:4 ratio using 20mm graded blue metal complete in a manner as directed by the Section Engineer in charge at site. NOTE: i)Cement shall be Ordinary Portland Cement, 43 grade, conforming to IS: 456 or latest. ii)Proper compaction of cement concrete shall be ensured as per standard industrial practices. iii)The finished level should match with surface level properly | — | 180.00 | — | — | |
| — | — | — | Above/ 24000.00 Below/P | ||
| Laying/leading of 4 core 16 sq.mm LTUG Aluminium cable in the excavated trench, Threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands, lugs, sockets and other items required complete as per site conditions in a manner complete as directed by Section Engineer in charge at site. Note:- 4Cx16 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 1000.00 | — | — | |
| — | — | — | Above/ 79200.00 Below/P | ||
| Laying/leading of 4 core 25 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands, lugs , sockets and other items required complete as per site conditions in a manner complete as directed by Section Engineer in charge at site. Note: - 4Cx25 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 3300.00 | — | — | |
| — | — | — | Above/ 14000.00 Below/P | ||
| Laying/leading of 4 core 35 sq.mm LTUG Aluminium cable in the excavated trench, Threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands, lugs, sockets and other items required complete as per site conditions in a manner complete as directed by Section Engineer in charge at site. Note:- 4Cx35 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 28000.00 Below/P | ||
| Laying/leading of 4 core 50 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands, lugs , sockets and other items required complete as per site conditions in a manner complete as directed by Section Engineer in charge at site. Note:- 4Cx50 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 1000.00 | — | — | |
| — | — | — | Above/ 77000.00 Below/P | ||
| Laying/leading of 4 core 70 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands, lugs , sockets and other items required complete as per site conditions in a manner complete as directed by Section Engineer in charge at site. Note:- 4Cx70 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 2200.00 | — | — | |
| — | — | — | Above/ 150800.00 Below/P | ||
| Laying of 50 mm dia High Density Polyethylene pipes in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. Note: 50mm dia HDPE pipe alone will be supplied departmentally. | — | 5800.00 | — | — | |
| — | — | — | Above/ 42000.00 Below/P | ||
| Laying of 63 mm dia High Density Polyethylene pipes in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. Note: 63mm dia HDPE pipe alone will be supplied departmentally. | — | 1500.00 | — | — | |
| — | — | — | Above/ 18000.00 Below/P | ||
| Laying of 75 mm dia High Density Polyethylene pipes in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. Note: 75mm dia HDPE pipe alone will be supplied departmentally. | — | 600.00 | — | — | |
| — | — | — | Above/ 63224.00 Below/P | ||
| Installation, Testing and Commissioning of the LT Earthing arrangements duly by excavating/ auguring of earth pit in all kinds of soil/concrete surface or elsewhere, construction of masonry earth pit enclosure, provision of cover etc, complete including supply / leading / laying / burying and concealing of GI strip 32 X 6 mm along with proper sleeve from earth electrode to proposed MDB / SDB or elsewhere and in a manner as directed by Senior Section Engineer in charge at site.Note:1) Masonry earth pit enclosure and cover shall be as per drawing number EL/P/TYPE/1022.2) LT Earthing Electrode alone will be supplied Departmentally. | — | 56.00 | — | — | |
| — | — | — | Above/ 3600.00 Below/P | ||
| Drawing of inside mains using 2 runs of 6 sq. mm [from MCB DB to switch boards and from switch boards to switch boards / or elsewhere] multistranded copper conductor cables duly inside the PVC conduit concealed / laid vide item No's 16/17 below complete as per the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. Note: - 2 runs of 6 sq. mm copper cable are taken as 1m for quantity purpose and will be supplied Departmentally | — | 300.00 | — | — | |
| — | — | — | Above/ 12000.00 Below/P | ||
| Drawing of inside mains using 2 runs of 4 sq. mm [from MCB DB to switch boards and from switch boards to switch boards / or elsewhere] multistranded copper conductor cables duly inside the PVC conduit concealed / laid vide item No's 16/17 below complete as per the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. Note: - 2 runs of 4 sq. mm copper cable are taken as 1m for quantity purpose and will be supplied Departmentally | — | 1000.00 | — | — | |
| — | — | — | Above/ 1500.00 Below/P | ||
| Drawing of inside mains using 2 runs of 10 sq. mm [from MCB DB to switch boards and from switch boards to switch boards / or elsewhere] multistranded copper conductor cables duly inside the PVC conduit concealed / laid vide item No's 16/17 below complete as per the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. Note: - 2 runs of 10 sq. mm copper cable are taken as 1m for quantity purpose and will be supplied Departmentally | — | 100.00 | — | — | |
| — | — | — | Above/ 22116.00 Below/P | ||
| Concealing of 20mm dia rigid PVC conduits along with all accessories i.e. Junction Boxes ,Bends and other items required asper site conditions complete including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit]Note:20mm dia PVC conduit pipe alone will be supplied Departmentally | — | 1164.00 | — | — | |
| — | — | — | Above/ 33155.00 Below/P | ||
| Concealing of 25mm dia rigid PVC conduits along with all accessories i.e. Junction Boxes ,Bends and other items required asper site conditions complete including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit]Note:25mm dia PVC conduit pipe alone will be supplied Departmentally | — | 1745.00 | — | — | |
| — | — | — | Above/ 25459.00 Below/P | ||
| Drawing of earth wire using 1.5 sq.mm PVC insulated copper conductor cables duly along wires vide item No's 13,14, and 15 above and light and fan points vide item No's 19,20 and 21 below or elsewhere complete in a manner as directed by Senior Section Engineer in charge at site. Note: 1.5 sq.mm copper cable alone will be supplied departmentally. | — | 3637.00 | — | — | |
| — | — | — | Above/ 14630.00 Below/P | ||
| Wiring to light, fan, exhaust fan points[Short point i.e. length upto 3 mtr] by supplyand drawing of 2 runs of 1.5 sq. mm FireRetardant Low Smoke PVC insulatedcopper multi- stranded copper cables of1100 V grade [conforming to IS: 694/1990or latest] duly inside the PVC conduitconcealed vide item No. 16/17 abovecomplete with Supply and provision of 6AModular switch conforming to IS:3854/2023 or latest, Supply and provisionof 1 No. 3 plate ceiling rose conforming toIS: 371/1999 or latest and with all standardaccessories along with all other men andmaterials required complete as per siteconditions complete and in a manner asdirected by Section Engineer in charge atsite. | — | 95.00 | — | — | |
| — | — | — | Above/ 67710.00 Below/P | ||
| Wiring to light, fan, exhaust fan points[Medium point i.e. length between 3 mtr to 6 mtr ] by supply and drawing of 2 runs of1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi-stranded copper cables of 1100 V grade [conforming to IS:694/1990 or latest] duly inside the PVC conduit concealed vide item No. 16/17above complete with Supply and provision of 6A Modular switch conforming to IS:3854/2023 or latest, Supply and provision of 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and with all standard accessories along with all other men and materials required complete as per site conditions complete and in a manner as directed by Section Engineer in charge at site. | — | 222.00 | — | — | |
| — | — | — | Above/ 25760.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Long point i.e. length between 6mtr to 9 mtr] by supply and drawing of 2 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi-stranded copper cables of1100 V grade [conforming to IS: 694/1990or latest] duly inside the PVC conduit concealed vide item No. 16/17 above complete with Supply and provision of 6AModular switch conforming to IS:3854/2023 or latest, Supply and provision of 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and with all standard accessories along with all other men and materials required complete as per site conditions complete and in a manner as directed by Section Engineer in charge at site. | — | 80.00 | — | — | |
| — | — | — | Above/ 22000.00 Below/P | ||
| Installation ,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 12 modules, switches, sockets, blank plates etc. duly accommodated onto suitable modular switch board box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including all wiring works complete including replastering painting etc. complete and in a manner as directed by Senior Section Engineer in charge at site. Note: -12 module Frame plate with matching cover plate, switch, socket and Modular GI box alone will be Supplied Departmentally. | — | 125.00 | — | — | |
| — | — | — | Above/ 26815.00 Below/P | ||
| Installation ,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 8 modules, switches, sockets, blank plates etc. duly accommodated onto suitable modular switch board box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including all wiring works complete including replastering painting etc. complete and in a manner as directed by Senior Section Engineer in charge at site. Note: -8 module Frame plate with matching cover plate, switch, socket and Modular GI box alone will be Supplied Departmentally | — | 155.00 | — | — | |
| — | — | — | Above/ 9954.00 Below/P | ||
| Installation ,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 6modules,switches, sockets, blank plates etc. duly accommodated onto suitable modular switch board box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including all wiring works complete including replastering painting etc. complete and in a manner as directed by Senior Section Engineer in charge at site. Note: -6 module Frame plate with matching cover plate, switch, socket and Modular GI box alone will be Supplied Departmentally. | — | 63.00 | — | — | |
| — | — | — | Above/ 174.00 Below/P | ||
| Installation ,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 4 modules, switches, sockets, blank plates etc. duly accommodated onto suitable modular switch board box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including all wiring works complete including replastering painting etc. complete and in a manner as directed by Senior Section Engineer in charge at site. Note: -4 module Frame plate with matching cover plate, switch, socket and Modular GI box alone will be Supplied Departmentally. | — | 2.00 | — | — | |
| — | — | — | Above/ 7912.00 Below/P | ||
| Installation, Testing and commissioning of the 300mm sweep BLDC Exhaust fan onto the buildings or elsewhere using suitable clamping and fixing arrangement complete as per industrial practices including supply connection from ceiling rose by using 3core 1.5 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper [White / Ivory colour] conductor flexible pendant chord conforming toIS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 300mm sweep BLDC Exhaust fan alone will be supplied departmentally. | — | 46.00 | — | — | |
| — | — | — | Above/ 29488.00 Below/P | ||
| Installation, Testing and commissioning of 1200mm sweep BLDC ceiling fan onto the buildings or elsewhere using suitable clamping and fixing arrangement complete as per industrial practices including supply connection from ceiling rose by using 3core 1.5 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper [White / Ivory colour] conductor flexible pendant chord conforming toIS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 1200mm sweep BLDC Ceiling fan alone will be supplied departmentally. | — | 152.00 | — | — | |
| — | — | — | Above/ 43200.00 Below/P | ||
| Installation, Testing and commissioning of4 feet 20W LED light fitting Batten type suitable to work on 240V single phase 50Hz AC with lamp and all standard accessories using suitable mounting and fixing arrangement as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper [White/Ivory colour]conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 4 feet LED 20W light fitting Batten Type with lamp alone will be supplied Departmentally | — | 450.00 | — | — | |
| — | — | — | Above/ 4940.00 Below/P | ||
| Installation, Testing and Commissioning including concealing work along with metal clad plug and socket unit in sheet steel enclosure conforming to IS: 8623/1993 or latest complete as per industrial practices with 1 No. 20 A,SP, MCB onto the walls including cutting/chipping and replastering and bringing back walls to original condition including painting in a manner as directed by section engineer in charge at site. Note: Metal clad plug and socket with Enclosure ,MCB alone will be supplied Departmentally. | — | 76.00 | — | — | |
| — | — | — | Above/ 520.00 Below/P | ||
| Installation, Testing and Commissioning including concealing work along with metal clad plug and socket unit in sheet steel enclosure conforming to IS: 8623/1993 or latest complete as per industrial practices with 1 No. 25 A,DP, RCBO onto the walls including cutting/chipping and replastering and bringing back walls to original condition including painting in a manner as directed by section engineer in charge at site. Note: Metal clad plug and socket with Enclosure and RCBO alone will be supplied Departmentally. | — | 8.00 | — | — | |
| — | — | — | Above/ 3388.00 Below/P | ||
| Installation, Testing and commissioning of50 W LED street light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour]conductor flexible chord conforming toIS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 50W LED street light fittings alone will be supplied departmentally. | — | 22.00 | — | — | |
| — | — | — | Above/ 5208.00 Below/P | ||
| Installation, Testing and commissioning of 80 W LED street light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour]conductor flexible chord conforming toIS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 80W LED street light fittings alone will be supplied departmentally. | — | 24.00 | — | — | |
| — | — | — | Above/ 4470.00 Below/P | ||
| Installation, Testing and commissioning of 50 W LED Flood light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour]conductor flexible chord conforming toIS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 50W LED Flood light fittings alone will be supplied departmentally. | — | 30.00 | — | — | |
| — | — | — | Above/ 601920.00 Below/P | ||
| a)Supply and Drawing of inside mains using 3 runs of 1.5 sq. mm [from MCB DB to switch boards and from switch boards to switch boards / modular furniture or elsewhere] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables conforming toIS:694/1990 or latest duly inside the PVC conduit laid vide 34) b) below complete asper the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. b) Supply and Concealing of 25mm dia rigid PVC conduits [IVORY colour] conforming to IS:9537 Part3(2021) or latest[ISI marked] with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site as per industrial standards and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] Note 1: - 3 runs of 1.5 sq. mm copper conductor and 1 m of 25mm dia PVC conduit pipe are taken as 1m for quantity purpose Note 2: Bends,Junction Boxes,Clamps,Screws and other items required for successful concealing of 25mm dia PVC conduit pipe at fixed intervals ,site conditions and as per directions of Section Engineer incharge at site is covered under contractors scope of work. | — | 4560.00 | — | — | |
| — | — | — | Above/ 233840.00 Below/P | ||
| a)Supply and Drawing of inside mains using 3 runs of 2.5 sq. mm [from MCB DB to switch boards and from switch boards to switch boards / modular furniture or elsewhere] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables conforming toIS:694/1990 or latest duly inside the PVC conduit laid vide 35) b) below complete asper the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. b) Supply and Concealing of 25mm dia rigid PVC conduits [IVORY colour] conforming to IS:9537 Part3(2021) or latest[ISI marked] with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site as per industrial standards and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit]Note 1: - 3 runs of 2.5 sq. mm copper conductor and 1 m of 25mm dia PVC conduit pipe are taken as 1m for quantity purpose Note 2: Bends,JunctionBoxes,Clamps,Screws and other items required for successful concealing of 25mm dia PVC conduit pipe at fixed intervals ,site conditions and as per directions of Section Engineer incharge at site is covered under contractors scope of work. | — | 1480.00 | — | — | |
| — | — | — | Above/ 164710.00 Below/P | ||
| a)Supply and Drawing of inside mains using 3 runs of 4 sq. mm [from MCB DB to switch boards and from switch boards to switch boards / modular furniture or elsewhere] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables conforming toIS:694/1990 or latest duly inside the PVC conduit laid vide 36) b) below complete asper the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. b) Supply and Concealing of 25mm dia rigid PVC conduits [IVORY colour] conforming to IS:9537 Part3(2021) or latest[ISI marked] with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer incharge at site as per industrial standards and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] Note 1: - 3 runs of 4 sq. mm copper conductor and 1 m of 25mm dia PVC conduit pipe are taken as 1m for quantity purpose Note 2: Bends,JunctionBoxes,Clamps,Screws and other items required for successful concealing of 25mm dia PVC conduit pipe at fixed intervals ,site conditions and as per directions of Section Engineer incharge at site is covered under contractors scope of work. | — | 910.00 | — | — | |
| — | — | — | Above/ 149600.00 Below/P | ||
| a)Supply and Drawing of inside mains using 3 runs of 6 sq. mm [from MCB DB to switch boards and from switch boards to switch boards / modular furniture orelse where] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables conforming toIS:694/1990 or latest duly inside the PVC conduit laid vide 37) b) below complete asper the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. b) Supply and Concealing of 25mm dia rigid PVC conduits [IVORY colour] conforming to IS:9537 Part3(2021) or latest[ISI marked] with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer incharge at site as per industrial standards and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] Note 1: - 3 runs of 6 sq. mm copper conductor and 1 m of 25mm dia PVC conduit pipe are taken as 1m for quantity purpose Note 2: Bends, Junction Boxes,Clamps,Screws and other items required for successful concealing of 25mm dia PVC conduit pipe at fixed intervals ,site conditions and as per directions of Section Engineer incharge at site is covered under contractors scope of work. | — | 680.00 | — | — | |
| — | — | — | Above/ 148170.00 Below/P | ||
| a)Supply and Drawing of inside mains using 3 runs of 10 sq. mm [from MCB DB to switch boards and from switch boards to switch boards / modular furniture or elsewhere] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables conforming toIS:694/1990 or latest duly inside the PVC conduit laid vide 38) b) below complete asper the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. b) Supply and Concealing of 40mm dia rigid PVC conduits [IVORY colour] conforming to IS:9537 Part3(2021) or latest[ISI marked] with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer incharge at site as per industrial standards and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] Note 1: - 3 runs of 10 sq. mm copper conductor and 1 m of 40mm dia PVC conduit pipe are taken as 1m for quantity purpose Note 2: Bends,JunctionBoxes,Clamps,Screws and other items required for successful concealing of 40mm dia PVC conduit pipe at fixed intervals ,site conditions and as per directions of Section Engineer incharge at site is covered under contractors scope of work. | — | 330.00 | — | — | |
| — | — | — | Above/ 52750.00 Below/P | ||
| a) Supply and Drawing of inside mains using 2 runs of 4 sq. mm along with 1 run of 1.5 sq.mm [from MCB DB to switchboards and from switch boards to switchboards / modular furniture or elsewhere]fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables conforming toIS:694/1990 or latest duly inside the PVC conduit laid vide 39) b) below complete asper the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. b) Supply and Concealing of 25mm dia rigid PVC conduits [IVORY colour] conforming to IS:9537 Part3(2021) or latest[ISI marked] with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer incharge at site as per industrial standards and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit]Note 1: - 2 runs of 4 sq. mm copper conductor ,1 run of 1.5 sq.mm copper conductor and 1 m of 25mm dia PVC conduit pipe are taken as 1m for quantity purpose Note 2: Bends,JunctionBoxes,Clamps,Screws and other items required for successful concealing of 25mm dia PVC conduit pipe at fixed intervals ,site conditions and as per directions of Section Engineer incharge at site is covered under contractors scope of work. | — | 250.00 | — | — | |
| — | — | — | Above/ 54234.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Short point i.e. length upto 3 mtr] by supply and drawing of 3 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi-stranded copper cables of 1100 V grade [conforming to IS: 694/1990 or latest] along with a) Supply and Concealing of 25mm dia rigid PVC conduits[IVORY colour] conforming to IS:9537 Part3(2021) or latest[ISI marked] with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site as per industrial standards and as per specification for wiring/ rewiring enclosed.[Approximate length of PVC conduit] b) Supply and provision of 6 A Modular type switch conforming to IS: 3854/1997 or latest, c)Supply and provision of 1 No. 3 plate ceiling rose conforming to IS:371/1999 or latest and with all standard accessories complete required as per site conditions and in a manner as directed by Section Engineer in charge at site. | — | 207.00 | — | — | |
| — | — | — | Above/ 84870.00 Below/P | ||
| Wiring to light, fan, exhaust fan points[Medium point i.e. length between 3 to 6 mtr] by supply and drawing of 3 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi-stranded copper cables of 1100 V grade [conforming to IS:694/1990 or latest] along with a) Supply and Concealing of 25mm dia rigid PVC conduits [IVORY colour] conforming toIS:9537 Part3(2021) or latest[ISI marked]with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site as per industrial standards and as per specification for wiring/ rewiring enclosed.[Approximate length of PVC conduit] b) Supply and provision of 6 A Modular type switch conforming to IS: 3854/1997 or latest, c)Supply and provision of 1 No. 3 plate ceiling rose conforming to IS:371/1999 or latest and with all standard accessories complete required as per site conditions and in a manner as directed by Section Engineer in charge at site. | — | 230.00 | — | — | |
| — | — | — | Above/ 65607.00 Below/P | ||
| Installation, Testing and commissioning of 600mm sweep BLDC Air circulators onto wall / stanchion / rail post or elsewhere using suitable clamping arrangement made of 40mm X 6mm MS flat and MS plate of size of 300mm X 300mm X 6mm complete in a manner as per standard industrial standards and in a manner as directed by Section Engineer in charge at site. Note: 600mm sweep BLDC Air circulators alone will be supplied Departmentally. | — | 57.00 | — | — | |
| — | — | — | Above/ 15480.00 Below/P | ||
| Erection, testing and commissioning of 4 meter Double arm octagonal pole assembly onto the suitable RCC foundation and coping by using modern engineering practice including installation, testing and commissioning of LED luminaries including all wiring works from nearby junction box asper industrial standards complete in a manner as directed by Section Engineer in charge at site. Note: 1) The foundation design and drawing along with supporting IS specifications suitable for Octagonal poles supplied by Railways and as per site conditions should be submitted for approval before starting the work 2) Four metre Double arm Octagonal pole and accessories along with luminaries alone will be supplied departmentally. | — | 6.00 | — | — | |
| — | — | — | Above/ 27272.00 Below/P | ||
| Erection, testing and commissioning of 5 meter Single arm octagonal pole assembly onto the suitable RCC foundation and coping by using modern engineering practice including installation, testing and commissioning of LED luminaries including all wiring works from nearby junction box asper industrial standards complete in a manner as directed by Section Engineer in charge at site.Note: 1) The foundation design and drawing along with supporting IS specifications suitable for Octagonal poles supplied by Railways and as per site conditions should be submitted for approval before starting the work 2) Five metre Single arm Octagonal pole and accessories along with luminaries alone will be supplied departmentally. | — | 8.00 | — | — | |
| — | — | — | Above/ 27272.00 Below/P | ||
| Erection, testing and commissioning of 5 meter Double arm octagonal pole assembly onto the suitable RCC foundation and coping by using modern engineering practice including installation, testing and commissioning of LED luminaries including all wiring works from nearby junction box asper industrial standards complete in a manner as directed by Section Engineer in charge at site. Note: 1) The foundation design and drawing along with supporting IS specifications suitable for Octagonal poles supplied by Railways and as per site conditions should be submitted for approval before starting the work 2) Five metre Double arm Octagonal pole and accessories along with luminaries alone will be supplied departmentally. | — | 8.00 | — | — | |
| — | — | — | Above/ 5510.00 Below/P | ||
| Installation, Testing and commissioning of 45 W LED street light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour]conductor flexible chord conforming toIS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 45W LED street light fittings alone will be supplied departmentally. | — | 38.00 | — | — | |
| — | — | — | Above/ 33495.00 Below/P | ||
| Erection, testing and commissioning of 150mm width x 50mm height made of 2mmthick hot dip galvanized Sheet steel complete with all accessories including coupler plate, supports fabricated MS flats of sufficient thickness and same duly supported from walls/ceiling/roof purloins/steel members of platform shelter/Foot over Bridge or elsewhere using intermediate supports of MS flats complete including carrying out all civil works incidental to provision/supporting/grouting of cable tray supports complete as per industrial standards ,site conditions and in a manner as directed by Section Engineer-in-charge at site. Note: 1)The cable tray supports shall be applied with two coats of red oxide primer and finished with two coats of bright aluminium paint.2)Cable tray alone will be supplied Departmentally | — | 55.00 | — | — | |
| — | — | — | Above/ 10248.00 Below/P | ||
| — | 14.00 | — | — | ||
| — | : - Installation, 40A/63A/100A,FP,RCBO/MCCB/RCCB with Cable cutting/chipping walls to original and outgoing Engineer Departmentally | Testing and as Incomer along adaptor box on to the and re-plastering and condition complete ends complete and as in charge at site. Note: | MCB DB's with SP/DP/FP,MCB's as feeder frame work condition including termination works manner as directed adaptor box etc alone | ||
| — | — | — | Above/ 50310.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Long point i.e. length between 6 to 9 mtr] by supply and drawing of 3 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi- stranded copper cables of 1100 V grade [conforming to IS: 694/1990 or latest] along with a) Supply and Concealing of 25mm dia rigid PVC conduits[IVORY colour] conforming to IS:9537 Part3(2021) or latest[ISI marked] with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site as per industrial standards and as per specification for wiring/ rewiring enclosed.[Approximate length of PVC conduit] b) Supply and provision of 6 A Modular type switch conforming to IS: 3854/1997 or latest, c)Supply and provision of 1 No. 3 plate ceiling rose conforming to IS:371/1999 or latest and with all standard accessories complete required as per site conditions and in a manner as directed by Section Engineer in charge at site. | — | 130.00 | — | — | |
| — | — | — | Above/ 258.00 Below/P | ||
| Installation, Testing and commissioning of Call Bell similar to Gold Medal Make and Model No: Curve plus and suitable for operation on 230 V, 50Hz, single-phase AC supply using suitable arrangement including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire retardant Low Smoke PVC insulated, PVC round sheathed copper (White/Ivory colour)conductor flexible pendant chord in a manner as directed by Section Engineer in charge at site. Note: Call Bell alone will be supplied Departmentally | — | 6.00 | — | — | |
| — | — | — | Above/ 2685.00 Below/P | ||
| Installation, Testing and commissioning of time switch assembly comprising of: -a)1 No. timer switch with daily setting similar to L&T catalogue reference J648B1 [FM1 Quartz].b)1 No. 3 pole 25A power contactor conforming to IS: 13947/P4/1993 or latest, c)1 No. 40A DP [MCB type] isolator conforming to IS: 13947/P3/1993 or latest, d)1 No. Neutral link etc. e)1 No. Earth link etc. f) Suitable rated control fuses all duly pre-wired and mounted on an appropriate sized well-seasoned wooden plank of thickness not less than 12 mm and duly housed into and powder coat finished enclosure of size not less than 300mm X 450mm X 300mm and made of 2mm thick Sheet Steel complete and provision of the same onto the wall or elsewhere using suitable fixing arrangements complete and in a manner as directed by Section Engineer in charge at site. Note: Timer switch, Power contactor,MCB, Neutral Link, Earth link, fuses,wooden box, Enclosures alone will be supplied Departmentally. | — | 5.00 | — | — | |
| — | — | — | Above/ 10422.00 Below/P | ||
| Erection, Testing and commissioning of 8 way Floor Mounting Type MCCB DB with 2 Nos of 250A, 36kA, FP, MCCB along with 250A FP onload COS as Incomer and (2 No's 100A,FP,+4 No's 63A),FP,MCCB's as outgoing including all cable termination at both Incoming and Outgoing sides complete and as per industrial practices complete in a manner as directed by Senior Section Engineer in charge at site. Note: MCCB DB,COS ,MCCB's alone will be supplied Departmentally | — | 3.00 | — | — | |
| — | — | — | Above/ 8040.00 Below/P | ||
| Installation, Testing and commissioning of 32A ,FP,MCCB with Enclosure onto wall or elsewhere using suitable angle iron framework and mounting and fixing arrangements as per industrial standards including all wiring and cable termination works at both Incoming and outgoing sides complete in a manner as directed by Section Engineer in charge at site. Note: 32A, FP, MCCB with Enclosure alone will be supplied Departmentally. | — | 30.00 | — | — | |
| — | — | — | Above/ 786.00 Below/P | ||
| Installation, Testing and commissioning of100A ,FP,MCCB with Enclosure onto wallor elsewhere using suitable angle ironframe work and mounting and fixingarrangements as per industrial standardsincluding all wiring and cable terminationworks at both Incoming and outgoing sidescomplete in a manner as directed bySection Engineer in charge at site.Note: 100A, FP, MCCB with Enclosurealone will be supplied Departmentally. | — | 2.00 | — | — | |
| — | — | — | Above/ 6928.00 Below/P | ||
| Supply, Erection,Testing and commissioning of cable route Indicator made of cast iron plate type as per Drawing No: CEE/CN/MS/11-2004 complete in an approved manner as directed by Section Engineer incharge at site | — | 16.00 | — | — | |
| — | — | — | Above/ 7202.00 Below/P | ||
| Installation, Testing and commissioning of 150W LED HighBay light fittings using suitable mounting and fixing arrangements as per industrial standards including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour]conductor flexible chord conforming toIS:694/1190 or latest complete in a manner and as per industrial standards as directed by Section Engineer in charge at site. Note: 150 W LED HighBay light fitting alone will be supplied departmentally. | — | 26.00 | — | — | |
| — | — | — | Above/ 1036.00 Below/P | ||
| Installation, Testing and commissioning of 200 W LED Flood light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated ,PVC round sheathed copper[White/Ivory colour]conductor flexible chord conforming toIS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 200W LED Flood light fittings alone will be supplied departmentally | — | 4.00 | — | — | |
| — | — | — | Above/ 2960.00 Below/P | ||
| Installation, testing and commissioning of16 W three dimensional type LED light fittings for pit lighting/catwalk lighting using suitable mounting and fixing arrangements as per industrial standards including power supply connection by using 3 core 1.5 sq.mm Fire retardant low smoke PVC insulated, PVC round sheathed copper conductor flexible chord conforming toIS:694/1990 or latest from nearby power source in a manner as directed by Section Engineer in charge at site. Note: 16W LED light fittings alone will be supplied departmentally. | — | 16.00 | — | — | |
| — | — | — | Above/ 1664.00 Below/P | ||
| Installation, testing and commissioning of Control panel unit containing 3 Nos SMPS Power supply units enclosed in Polycarbonate enclosure with all connected safety accessories, indication& controls ,dedicated for the High power LED based 16W LED Pit/Catwalk lights as per standard industrial practices including power supply connections from nearby power source complete in a manner as directed by Section Engineer in charge at site. Note: Control panel assembly alone will be supplied Departmentally. | — | 4.00 | — | — | |
| — | — | — | Above/ 2340.00 Below/P | ||
| Installation, Testing and commissioning of SMC box assembly similar to Sintex Catalogue reference No. GSJB-3020 along with strip connector block, Neutral link, fuse bases and carriers onto lamp posts or elsewhere including wiring from junction box to light fitting by using suitable multistranded flexible copper cable conforming to IS:694/1990 or latest complete including all fixing arrangements and other accessories required complete as per site conditions in a manner as directed by the section engineer in charge at site. Note: SMC GSJB-3020 box, strip connector, neutral link, Earth link,Fuse bases and fuse carriers arrangements alone will be supplied Departmentally. | — | 20.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Technicaldocuments.pdf
ATTACHMENT
Tenderschedulebreakup.pdf
ATTACHMENT
Checklistlessthan50Lakh.pdf
ATTACHMENT
GCCandACS1-12.pdf
ATTACHMENT
GeneralinstructionstoTenderers.pdf
ATTACHMENT
IdentityCardsamplewithguidelines.pdf
ATTACHMENT
ImportantinstructionstoTenderers.pdf
ATTACHMENT
ModelformofBGbondwithinstructions.pdf
ATTACHMENT
NEFTFORM.pdf
ATTACHMENT
Payment_clause_for_LED_luminaries_and_BLDC_fansasper2026.pdf
ATTACHMENT
Special_conditions_of_Contract_Electrical_12_months_GCC_ACS_12.pdf
ATTACHMENT
StandardGuaranteecertificateformat.pdf
ATTACHMENT
Undertakings.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .