Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.2 LAccepted-AOC E 30 RAJIV NAGAR BEGAMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹51.6 L+₹1.8 L (3.63%)Rejected-AOC 0 0 KAIMGANJ ROAD KUIYA SANT FARRUKHABAD UTTAR PRADESH 209745 | FARRUKHABAD | UTTAR PRADESH | 209745 | L2 | Rejected-AOC Neither lowest nor competitive |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
2 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
PROVN OF CERTAIN SANCTION WORKS IN THE AREA OF AGE B/R-II AND AGE E/M UNDER GE (CENTRAL) DELHI CANTT-10
2020_MES_381127_3
GE/C-50/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt
₹92,000
Yes
22 Dec 2020
13 Nov 2020
4 Dec 2020
13 Nov 2020
2 Dec 2020
20 Nov 2020
13 Nov 2020 - 20 Nov 2020
60 days
Amount
Dismantling Asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed by Engineer-in-Charge.
Dismantling mild steel framed trusses, rafter incl purlins complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar in any description and position, complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames n.exc 1.5 sqm each with shutters (without taking off shutters from frames), complete all as specified and directed by Engineer-in-Charge
Taking down chowkats or frames exc. 1.5 Sqm and n.exc 4 Sqm each with shutters (without taking off shutters from frames ), complete all as specified and directed by Engineer-in-Charge
Taking down shutter of any description exc 1 sqm and not exc 2 sqm each, complete all as specified and directed by Engineer-in-Charge
Taking down shutter of any description exc 1 sqm and not exc 2 sqm each, and refixing in same opening complete all as specified and directed by Engineer-in-Charge
Dismantling boarding any description (board/plywood) fixed in any position with screw, complete all as specified and directed by Engineer-in-Charge
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar,complete all as specified and directed by Engineer-in-Charge
M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete or similar works complete all as specified and directed by Engineer-in-Charge
M&L Reinforced cement concrete M 25 ( Design Mix) using 20mm graded aggregate as in Foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge
M&L Reinforced cement concrete M 25 ( Design Mix) using 20mm graded aggregate as in columns, etc.; complete all as specified and directed by Engineer-in-Charge
M&L Reinforced cement concrete M-25 (Desig mix) using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge
M&L form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batten complete for rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge
M&L form work to sides of pillars, posts, struts, piers, columns/slabs, and similar work, complete for rough finished surfaces of concrete, complete all as specified.
Supply and fix TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) but not less than 0.9 mm dia conforming to Fe-410 - 0, complete all as specified and directed by Engineer-in-Charge
All as per item No 16 but 8mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engineer-in-Charge
M & L for brick work with flyash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge
M&L for brick work with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls with old size bricks, built in cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge
M/L for 15 mm thick in CM 1 : 6 rendering on fair faces of brick work or concrete surfaces etc finished even and smooth without using extra cement Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 complete all as specified and directed by Engineer-in-Charge
M & L for 15 mm thick internal rendering in cement mortar 1:6 on other than fair face of brick walls/ concrete surfaces & finished even and smooth without using extra cement, including taking down old plaster complete all as specified and directed by Engineer-in-Charge
M & L for 10 mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling, chajja and like surface finished even and smooth without using extra cement including taking down old plaster complete all as specified.
Supply only integral water proofing admixture of approved quality complete all as specified and directed by Engineer-in-Charge. (make: Pideilite or equivalent)
M&L PCC 1:2:4 Type B1 using 20mm graded stone agg as in coping,hold fast ,benching lintels upto 1.50m clear span & filling in past hole etc. including weathering slightly rounded or chamfered angles or throating including formwork to concrete surface complete all as specified and directed by Engineer-in-Charge
M&L for Preparation of new/existing scrapped surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper(white or tinted) over a coat of 2 to 3mm thick chalk whitning wall putty over one coat of alkali resistant primer on plastered surfaces, complete all as specified and directed by Engineer-in-Charge
M&L for preparation of new plastered wall surfaces and applying two or more coats of Plastic emulsion paint upto 1.20m height of wall complete all as specified and directed by Engineer-in-Charge
M & L for applying two coat of cement base paint over one coat of primer including prepration of newly platered surface complete all as specified and directed by Engineer-in-Charge
S&F Roof trusses (framed), truss, framed brackets of angles, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel flat or hollow sections) including distance pieces, cleats etc. Fe 410-W(Gde E-250) quality-A complete all as specified and directed by Engineer-in-Charge
S & F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment for numbering of garages duly fixed with the member including red oxide primer complete all as specified and directed by Engineer-in-Charge
S&F Mild steel screw bolts (machine made) 12mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 20cm long complete all as specified and directed by Engineer-in-Charge
S&F Pre painted curved galvalum aluminium zinc coating GI based corrugated sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall ,fixed with self tapering screws as specified by Engineer in Charge.
S&F 0.63 mm thickness of Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of Zinc coating 275 complete all as specified and directed by Engineer-in-Charge
M&L for 2nd class hardwood plain, solid straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, complete all as specified and directed by Engineer-in-Charge
S& F 35 mm thick flush shutters (factory made) solid core construction, with block board core and plywood face pannel, commercial type on both sides. Flush shutters shall have teak wood edging as specified complete all as specified and directed by Engineer-in-Charge
S&F 35mm thick 2nd class Hard wood rail & style (factory made) plain, framed, panelled shutter (two panel) with lock rail & panel of 12mm veneered particle board with commercial veneering on both sides. The size of rail & style as per IS :1003 (Part I), Kilan seasoned & chemicals pressure treated,complete all as specified and directed by Engineer-in-Charge
M&L for 35 mm thick 2nd class hard wood glazed and skelton door shutter, factory made, open rebated and prepared to receive glass/guage etc. (without sash bar) edge of frames plain, chamfered or rounded, fitted with cut & mitred beads for securing glass/guage etc size of member as specified in SSR Part I Section 8 clause 20(a) and fixed to chowkat, complete all as specified and directed by Engineer-in-Charge
S& F 25 mm thick flush shutters solid core construction, with block board core and plywood face pannel, commercial type on both sides. , complete all as specified and directed by Engineer-in-Charge
Cutting holes in brick wall built in cement mortar for inserting hold fasts, depth of embedded postion of hold fast /lugs measured from the face the jambs into the wall exc half brick but n.exc one brick thick and making good the dismantaled portion in cement mortar 1:3 or in cement concrete 1:2:4 type B-1, using 20mm graded stone agg complete all as specified upto six storey height complete all as specified and directed by Engineer-in-Charge.
S&F mild steel work as in hold fast 25x3mm flat iron and similar articles conforming to Fe-410-0, complete all as specified and directed by Engineer-in-Charge
S&F powder coated aluminum frames for doors, windows and ventilators with one or more rebates including jointing cleats for fixing etc including aluminium grill complete all as specified and directed by Engineer-in-Charge.
S&F powder coated 50 micron aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges,anodised alumnium snap beading, screws etc.complete all as specified and directed by Engineer-in-Charge
S&F powder coated 50 micron aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.),hinges type B-21 100mm long (2no.) suitable handle ,(01 no.) complete all as specified and directed by Engineer-in-Charge
S&F 4.00 mm thick plain sheet glass and glazing with oil putty in square n.exc 0.5 Sqm in each pane, complete all as specified and directed by Engineer-in-Charge
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with steel wire staples, complete all as specified and directed by Engineer-in-Charge
S&F 4.00 mm thick figured glass, pin head type and glazing with wooden beads, glass putty, PVC beading, aluminium beads, complete all as specified and directed by Engineer-in-Charge Make : Saint Gobain or equivalent
S&F 5.5 mm thick sheet glass ordinary quality in square n.exc 0.5 Sqm each including grinding of edges for crockery cupboard including taking out/ broken glass with roller, complete all as specified and directed by Engineer-in-Charge
M&L for 18/19mm thick block verneered board core grade 2 quality,interior grade,commercial type, fixed with screws to timber frame work as in cup board shutter, loft shutters incl 15mm thick teak wood leaping and necessary rebating for leaf shutters where required including polishing to leaping/rebating complete all as specified and directed by Engineer-in-Charge
S&F factory made PVC frame of size 75x40mm with wall thickness of 4mm made out of extruded 4mm thick plain or prelam PVC sheet reinforced with 15x15mm MS square tube of 19 gauge thickness through out the frame and mitred cut and two corners and jointed with two nos of 150mm long bracket of 10x10mm MS Square tube. The door frame shall be fixed to the wall using 65x100mm long MS screws though the frame by using PVC fastners minimum of four Nos of screws to be provided for each vertical members and minimum of two nos of screws to be provided horizintal members etc complete all as specified and directed by Engineer-in-Chargemanufacture instructions and directed.
S&F 18/19mm thick PVC moulded solid board one side pre-laminated for cabinet boxes etc with self and shutter full size fitted under/above the kitchen cooking platform and other platform directed incl provn of fixing arrangement etc, complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm long (size) butt hinges, medium weight, cold rolled mild steel, complete all as specified and directed by Engineer-in-Charge
S&F 50 mm long (size) butt hinges, medium weight, cold rolled mild steel, complete all as specified and directed by Engineer-in-Charge
S&F continuous (Piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 30 mm, complete all as specified and directed by Engineer-in-Charge
S&F in repairs 75 mm long L Bihari concealed type hydrauilc hinges incl stainless screw complete all as specified and directed by Engineer-in-Charge
S & F in repairs 150mm size double action spring, hinge, mild steel with steel wire spring, stove enamelled black,complete all as specified and directed by Engineer-in-Charge
S & F 300 mm long, Mild Steel sliding door bolts,plate type, stove enamelled black, with bright bolts not less than 12mm dia with & including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engineer-in-Charge
S&F 150mm long mild steel barrel tower bolts stove enamelled black with bright bolt & fixed with screws, complete all as specified and directed by Engineer-in-Charge
S&F 150mm size mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed by Engineer-in-Charge
S&F stainless steel of floor door stopper with hard drawn steel spring 140 mm long ,complete all as specified and directed by Engineer-in-Charge
S&F Hasp and staple, 75mm size, safety type, brass with mild steel hinge pin including bolt to hinge plate & fixed with screws, complete all as specified and directed by Engineer-in-Charge
S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed, complete all as specified and directed by Engineer-in-Charge
S&F mild steel 150mm ordinary rat tail , rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge
Dismantling of existing wooden pelmet box of any description and size and making good the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge
S & F in repair stainless steel drapery Rod 25mm dia make and model of vista, including wooden side caps, brackets, complete all as specified and directed by Engineer-in-Charge
M&L for Preparation of new or previously untreated wood and wood based surfaces of any description not otherwise described over 10cm width girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed by Engineer-in-Charge
M&L 75 mm PCC(1:4:8) type D2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed by Engineer-in-Charge
M&L cement concret 1:2:4 type B-O (12.5 mm graded stone aggregate) as in flooring 25 mm thick, complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish,vegitation outside complex (MOD land), complete all as specified.Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 complete all as specified and directed by Engineer-in-Charge
M&L for coloured glazed ceramic tiles 300x600 x 7 to 8mm thick as in vertical surfaces of wall as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed by Engineer-in-Charge
M&L for coloured ceramic tiles (Non skid) of size 300x300x 6 to 7mm thick as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement over 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge
M&L for Vitrified Ceramic tiles 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed by Engineer-in-Charge
All as per item No 71 above but as skirting over and including 10mm thick rendering in CM 1:4 including demolition of existing PCC/Terrace skirting complete all as specified and directed by Engineer-in-Charge
M & L for 16-18 mm thick Machine cut kota single piece stone slab for floors and size 22''x22'' for flooring over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab laid over and including 15mm thick screed bed in CM 1:6 and rubbing and polishing complete all as specified and directed by Engineer-in-Charge
M&L for 16-18mm thick black granite stone work (table rubbed and polished) laid over and including 15mm thick screed bed or bedding layer in CM 1:4 as in steps, Jambs, pillars, window clips, cooking platforms and like, inlcuding pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, front and side of slab moulded and polished complete all as specified and directed. Granite stone slab shall be laid in single piece with rounding of edgesand a grove shall be provided beneath the projection portions of stone slab and provn of hole for gas pipe shall be provided complete all as specified and directed by Engineer-in-Charge.
S & F 50 mm dia Galvanised Iron steel tubing, medium grade as in spout in short length, complete all as specified and directed by Engineer-in-Charge
S&F in repair cast iron floor trap square type with Cockroch Proofing CP grating with or without hole including provision of jointing to waste pipes in run lead joint dia of outlet 75 mm, complete all as specified and directed by Engineer-in-Charge
S&F in repair Salt Glazed Stone Ware (SGSW) gully traps square or round mouthed type size 150x150mm including excavation/earth work, bed concrete, surrounding concrete and CI grating, complete all as specified and directed by Engineer-in-Charge
S&F in repair CP grating 125mm dia, ccomplete all as specified and directed by Engineer-in-Charge
S&F in repair aluminium peg set of 6 peg, 45 centimeter long, complete all as specified and directed by Engineer-in-Charge
S&F in repairs bib tap with crutch or butterfly handle, screwed down, screwed for iron pipe, 15mm dia, fancy type, cast copper alloy, chromium plated long body with flange complete all as specified and directed by Engineer-in-Charge
S&F in repair std of PTMT bib tap fancy type with flange 15mm dia screwed for iron pipe or for brass ferrule complete all as specified.
S&F 20mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed. Minimum wt 15 mm -142grm , 20mm-210grm ,25mm -455grm,40mm-690grm complete all as specified and directed by Engineer-in-Charge
S&F in repairs of 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
S & F Steel windows and ventilators with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by Engineer-in-Charge
S & F MS framed work such as grills, gratings etc with ends of bars shouldered and or riveted, framed guard bars, barred iron doors, ladders, frame work of water trough, railings,cooler stand and similar work to conforming to Fe -290-0 ornamental design, complete all as specified upto six storey height complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of new steel and iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of redoxide primer, complete all as specified and directed by Engineer-in-Charge
M&L for Preparation of old painted surfaces of steel and iron surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15cm thickness ( below or above ground level ) including removal of rubbish out side complex (MOD land), complete all as specified and directed by Engineer-in-Charge
M & L for 75 mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished fair and even without using extra cement, complete all as specified and directed by Engineer-in-Charge
M&L for false ceiling in repairs using plain galvanized steel ceiling system consisting of 600X600 mm lay in tiles of pre-coated galvanized sheet 0.5mm thick in white or colour to be laid on gird system with 15 mm wide T section of size 45X45 mm flanges having stiching rotray stiching on the main runner tie, arm runner spaced 600 mm centre flush fitting 600mm long cross tees to be interlocked between runner at 600 mm centre to form 600x600 mm module perimeter trim to be wall angle of size 3000x45x15mm secured to wall and including suspension system as per manufacturer instruction complete all as per specified and directed by Engineer-in-Charge. Work to be executed through authorised represenatative of manufacturer.
Excavation in trenches, any type of soil n exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, erlls, cesspits, manholes, pier holes, etc n exc 10 sq m on plan and n exc 1.5 m in depth and getting out.complete all as specified directed by Engr-in-Charge.
"S & F DWCPE sewage pipe (SN 4 class) 150 mm diameter, snap fit coupler & rubber ring including testing laying in trenches & jointing over a level concrete bed complete all as specified and directed by Engineer-in-Charge
Returning filling in incl spreading, leveling watering and well running in layers n.exc 25 cm.complete all as specified directed by Engr-in-Charge.
Removing excavated soil to a distance n. exc 50 mtr and depositing were directed at a level n. exc 1.5 mtr above the starting point.complete all as specified directed by Engr-in-Charge.
M & L for Cutting of exising 150 mm dia manholes for connecting new drains making good to pipe and rendering cutting out exising benching for and forming benching for and forming branch channel (1/2round or 3/4 section ) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching required complete all as specified directed by Engr-in-Charge.
M & L for Brick work flyash bricks straight or curved on plan built in cement mortar 1:4 using old size bricks.complete all as specified directed by Engr-in-Charge.
M & L for Cement concrete 1:3:6 type C-2(40mm aggregate ) as in foundation manholes.complete all as specified directed by Engr-in-Charge.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 mixed with water proofing compound finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. (Water proofing compound shll be measure and paid separatelly).
M&L for precast factory made manhole cover, area of each cover n.exc 0.60 Sqm, 100mm thick with SFRC concreting including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet complete all as specified and directed by Engineer-in-Charged.
M & L for clening of sewage lines upto 300mm internal dia of pipe including removing of silts,organic or inorganic material including removal of sludge in manholes(upto 3.00m depth) and desilting of entire sewage lines all as specified and directed. Note. The measurement will be taken in linear length including manholes. No separate measurement will be allowed for manholes complete all as specified and directed by Engineer-in-Charge.
Surface dressing averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge
M & L Machine pressed precast concrete rubber moulded interlocking coloured paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-40 Grade including cement concrete 1:4:8 type D2 (40mm graded stone aggregate) as in sub base 75mm thick and 25 mm thick sand cushioning etc complete all as specified and directed by Engineer-in-Charge. Make Unistones/ Nitco/ Ultra Tiles.
S&F pre-cast concrete blocks for kerb stone with solid block exc 10 cm in width type C-1 , 1:3:6 ( using 20 mm graded stone aggregate) set in CM 1:6 of any shape and size as approved by Garrison Engineer, including necessary excavation and earth work including returning filling in the earth and removal of surplus earth from site if any, kerb stone shall be fixed in true line and level or in curves for edging of road side path including embedding PCC pre cast block in ground to any depths as required and tamping soil around PCC blocks including two coat of enamel paint over a coat of primer of kerb stone blocks complete all as specified and directed by Engineer-in-Charge
M & L for non skid 600x600x08 to 09mm thick coloured rectified ceramic tiles as in floor over and including 15mm thick screed bed in CM 1:6, including pointing in coloured cement to match the shade of tiles including hacking out the existing floor surface,cleaning with water and applying cement slurry @ 3 kg/sqm on prepared surface of floor and including cutting/adjusting of existing door shutter at required height after taking down and refixing complete all as specified and directed by Engineer-in-Charge
All as per item No 108 above but 10mm thick on rendering surface in CM 1:4 on vertical surfaces of wall as in skirting including taking down of existing skirting/dado with screed/plaster on walls complete all as specified directed by Engr-in-Charge.
M & L for 600x600x08 to 09mm thick light coloured vitrified tiles(joint less) as in floor over and including 15mm thick screed bed in CM 1:6, including pointing in coloured cement to match the shade of tiles including hacking out the existing floor surface,cleaning with water and applying cement slurry @ 3 kg/sqm on prepared surface of floor and including cutting/adjusting of existing door shutter at required height after taking down and refixing complete all as specified directed by Engr-in-Charge,
S&F in repair vitreous China coloured European type WC with "P" trap 1st quality including connection to drain and fixing bolts,plastic water closet seat cover complete all as specified and directed by Engineer-in-Charge
S&F in repair 10 ltrs capacity PVC colour low level flushing cistern with PVC flush pipe 32mm dia complete all as specified and directed by Engineer-in-Charge
S & F Brass CP health faucet of 15mm dia incl extension pipe in 1.5 mtr length screwecd for iron pipe fancy type long body complete all as specified and directed by Engineer-in-Charge
S&F in repair brass chromium plated toilet paper holder, complete all as specified and directed by Engineer-in-Charge
Supply & fix in repair PVC connection pipe of 1/2"x18" size with 2 Nos brass check nuts with washers, complete all as specified and directed by Engineer-in-Charge
S&F in repairs vitreous chinaware wash hand basin, white, flat back of size 580mm x 400mm including CP Waste coupling ,waste pipe ,complete fixing arrangement and cutting for and pinning in walls & making good complete all as specifed and directed by Eng in charge.
S&F in repair 15mm dia brass chromium plated mixer for mixing hot and cold water screwed down for iron pipe and fixed to WHB including taking out existing mixer from old WHB, complete all as specified and directed by Engineer-in-Charge
S&F in repair brass chromium plated soap dish, complete all as specified and directed by Engineer-in-Charge.
S&F in repair chromium plated brass angle valve dual type (two in one) suitable for 15mm bore pipe complete all as specified and directed by Engineer-in-Charge
S&F in repair 15mm dia chromium plated wall mixer hot & cold L bend 3 in 1 pattern fixing and connection to pipes complete all as specified and directed by Engineer-in-Charge
S&F in repair 15mm dia chromium plated fancy type wall mixer hot & cold with long swan for kitchen sink fixing and connection to pipes complete all as specified and directed by Engineer-in-Charge
S&F in repair chromium plated brass angle valve type suitable for 15mm bore pipe complete all as specified and directed by Engineer-in-Charge
S & Fixed in repair 125mm size brass CP shower rose complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel of AE - SI 316 grade tubular towel ring including apair of CP brass bracket complete all as specified and directed by Engineer-in-Charge
S&F stainless steel towel rack size 600mmX 300mm including apair of brass bracket complete all as specified &directed by Engr in charge.
M & L for 10 mm thick internal rendering in cement mortar 1:6 on fair face of brick walls/ concrete surfaces & finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge
S & F in repair Stainless steel drapery Rod 20 mm of dia ,with bracket including including premium balls complete incl taking down old pelmet box all as approved by Engineer-in-charge
S&F in repair 15mm dia chromium plated fancy type wall mixer hot & cold with long swan for kitchen sink fixing and connection to pipes complete all as specified and directed by Engineer-in-Charge
M&L for rendering 15mm thick on fair faces of brick or concrete in CM (1:4) even and smooth without using extra cement, complete all as specified and directed by Enginer in Charge. Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 complete all as specified and directed by Engineer-in-Charge
M& L for preparing newly plastered surfaces and applying two coats of Oil Bound Distemper using airless spray gun directly fed from paint bucket all complete all as specified and directed by Engineer-in-Charge. Make :- Asian paints (Royale)/NerolacPaints/ Berger (Rangoli)
S&F in repair 40mm dia cupboard knobs fixed with nut,screw and washer of mild steel bright finished complete all as specified and directed by Engineer-in-Charge
S&F 75mm size Brass handles, cast type, polished bright , complete all as specified and directed by Engineer-in-Charge
S&F in repair stainless steel sink with drainage board made out of 1.00mm thick sheet for kitchen with plug, washers, waste pipe including connecting union overall size 1145mm x 510mm x 200mm with bowl size 510mm x 400mm x 200 mm including taking out existing china ware sink with waste fittings complete all as specified and directed by Engineer-in-Charge
S&F in repairs Stainless Steel plate rack of size 90x80x25cm made with 1.00 mm thick sheet including taking out existing wooden plat rack, complete all as specified and directed by Engineer-in-Charge
S& F 25 mm thick flush shutters solid core construction, with block board core and plywood face panel, commercial type on both sides complete all as specified and directed by Engineer-in-Charge
S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position with 20mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule Minimum wt 20mm-210grm and s&f in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed incl Dismantling of PVC water tanks of exc 500 litres and n.exc 1000 litres capacity of any condition or type incl complete all as specified and directed by Engineer-in-Charge
S & F 500 ltr capacity three layer white colour rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with 20mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.Minimum wt 20mm-210grm including dismantling old water tank all as specified in SSR Part I I complete all as specified and directed by Engineer-in-Charge
Disconnecting existing tanks ,setting aside (or lowering if required) for repair,cleaning etc and hoisting if required for repair and cleaning etc and hoisting if required reconnecting and refixing in position capacity exc 500 ltr but not exceeding 1000 ltr complete all as specified and directed by Engineer-in-Charge
Taking up or down 15 mm dia GI tubing and connections including cleaning for re-fixing including scafolding etc, complete all as specified Note :- (For Ser item No 139 to 144. All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 and the two GI lines should be minimum 5 cm apart from each other with or without using GI clamps (GI clamps inclusive in this item only and nothing extra should be paid for clamps) and each GI 20 mm line should be minimum 10 cm apart from wall and fixed by using GI clamps placed at 2 m apart throughout the height of bldg (GI clamps inclusive in this item only and nothing extra should be paid for clamps) complete all as specified and directed by Engineer-in-Charge
Taking up or down 20 mm dia GI tubing and connections including cleaning for re-fixing including scafolding etc, complete all as specified and directed by Engineer-in-Charge
Taking up or down 25 mm dia GI tubing and connections including cleaning for re-fixing or removal to store in any position complete all as specified and directed by Engineer-in-Charge
S&F 15mm dia GI tubing medium grade with all fitting and fixed to wall and ceiling or laid in floors etc including scafolding, cutting chases in wall where ever required etc complete all as specified and directed by Engineer-in-Charge
S&F 20mm dia GI tubing medium grade with all fitting and fixed to wall and ceiling or laid in floors etc including scafolding, cutting chases in wall where ever required etc complete all as specified and directed by Engineer-in-Charge
S&F 25 mm dia GI tubing medium grade with all fitting and fixed to wall and ceiling or laid in floors etc as in horizontal or vertical surfaces complete all as specified and directed by Engineer-in-Charge
S&F in repairs of 25mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
M&L Wire brushing and cleaning top surface of tiles, or cement concrete, including flashings and junction of parapets, etc., cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed by Engineer-in-Charge
M&L water proof treatment to RCC roof slab by providing 50 mm average thickness PCC 1:2:4 incorporting CONPLAST WL (water prooof compound) in the proportion as directed by the manufacturer and apply on damp PCC surface, first coat of Brush Bond RFX and again apply second coat of Brush Bond RFX after drying of first coat (average 1 - 1.5 mm thickness) and on completion, provide 25 mm thick PCC 1:2:4 mix (4 parts of 10mm nominal coarse aggregate, 2 parts of fine aggregate & 01 part of cement) cement concrete screed and then finsh the top sufurace even and smooth without using extra cement . The compete roof shall be tested by ponding of water for 24 Hrs complete all as specified and directed by Engineer-in-Charge. Note :- Brush bond RFX liquid, powder and conplast WL shall be of FOSROC or equivalent in Star/Pidilite.
S&F in repair of 150mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed complete to walls, ceilings or in floors with suitable clamps/bracket including taking down old PVC/CI pipes and necessary cutting through RCC roof and brick work etc (above six storey height) and making good all as specified.
M&L for 15mm average thick (average) screed bed in cement mortar 1:4 using WPC on roof surfaces & finished even and smooth with using extra cement and applying two coat of building grade bitumen 85/25 @ 1.2 Kg/Sqm in each layer in any position complete all as specified and directed by Engineer-in-Charge
M&L preparation of newly plastered surfaces as of walls/ceiling and applying two coat of external weather proof acrylic emulsion paint over a coat of primer of same manufacture and surface shall be prepared with white cement puttty including scaffolding upto six storey height complete all as specified and directed. Note :- (i) Contractor shall have to render 5years guarantee for the weather exterior paint & a FDR to the 10% of the amount of respective items shall be given by the contractor for five years. (ii) Primer cost included in this item only and all the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 complete all as specified and directed by Engineer-in-Charge
Dismantling of brick tiles or terracing tiles single layer on roof and removing the rubbish outside complex (MOD land),incl removal of vagitation if any complete all as specified and directed by Engineer-in-Charge
Demolition of mud in roof, any thickness, including mud plastering and mud phuska under brick tiles at any situation and height, complete all as specified and directed by Engineer-in-Charge
M&L for PCC 1:2:4 (using 20mm aggregate) type B-1 as in levelling course using WPC finished even and smooth without using extra cement (WPC shall be measured and paid seperately) complete all as specified and directed by Engineer-in-Charge
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening complete all as specified and directed by Engineer-in-Charge
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30 mm thick (stiles),with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm Plain colour PVC sheet on back face, complete all as specified and directed by Engineer-in-Charge
S&F SS butt hinges medium weight 100 mm size fixed with SS screws complete all as specified and directed by Engineer-in-Charge.
S&F aluminium anodised barrel tower bolt extruded section 200 mm long and fixed with MS screws complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with MS screws complete all as specified and directed by Engineer-in-Charge.
S&F 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut complete all as specified and directed by Engineer-in-Charge.
Dismantling of cast iron drain pipes 100 mm dia jointed in cement mortar complete all as specified and directed by Engineer-in-Charge
Dismantling of cast iron drain pipes 75 mm dia jointed in cement mortar complete all as specified and directed by Engineer-in-Charge
M & L for Glazed ceramic coloured tiles 200x300x 7 to 10 mm thick in dado, set and jointed in neat cement slurry and pointed in colour cement to match laid over and including rendering 10mm thick in cement mortar 1:4 including demolition of old damaged tiles complete all as specified and directed by Engineer-in-Charge
S&F in repair brass chromium plated tubular towel rail 20mm dia D type 60cm long between flanges including a pair of CP brass brackets, complete all as specified and directed by Engineer-in-Charge
Supply only waste fitting 32/40 mm dia brass chromium plated for WHB/Sink with long screwed and shanks and fly nuts, flanged end bedded in red lead cement and other end fixed, complete all as specified and directed by Engineer-in-Charge
S&F in repairs 32/40mm bore and 75cm long PVC waste pipe for WHB/Sink complete all as specified and directed by Engineer-in-Charge
S&F in repair stop valve 15mm dia fancy type chromium plated with long shank and cap (concealed type) complete all as specified and directed by Engineer-in-Charge
M&L for 5mm thick rendering in cement mortar 1:3 on ceiling/concrete surface finished even and smooth surface without using extra cement complete all as specified and directed by Engineer-in-Charge Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4
Preparation of old decorated surface (plastered or unplastered) of ceilings incl cornices pillar etc by brooming down or steel wire brushing, scraping down smoke root mould moss and efforesceent salts and treating oil and greasy spots as applicable and applying two coata of white lime wash on ceiling surfaces complete all as specified and directed by Engineer-in-Charge
M & L for preparation of newly plastered surfaces of ceilings and applying three coats of white lime wash premier quality on wall surface over one coat of primer from the same manufacturer complete all as specified and directed by Engr-in- Charge Note :- Primer cost included in this item only and all the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4
M&L removing existing old treatment from walls using mechanical grinder complete all as specified and directed by Engineer-in-Charge
Complete removal exising old surfaces of wall / ceiling of chajjas by scrubbing with hard brushing ,brooming down or steel wire brushing scraping down smook root mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water and applying cement based wall care putty of approved make 1mm thick (average thickness) unifomly and applying Two coats of weather proofing exterior acrylic emulsion paint of DULUXWeather shield Max or APEX ULTIMA from Asian paint over one coat of primer from the same manufacturer complete all as specified and directed. Note: Contractor shall have to render 5 yrs guarantee for weather proof paint and render a FDR @ 10% of work done for 5 years)
S&F in repairs 100 mm dia bore spun type cast iron soil waste and vent pipes in any length with or without ears, with cement joints fixed to walls or laid in trenches complete all as specified and directed by Engineer-in-Charge Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 and the two CI pipes should be minimum 5 cm apart from each other with or without using GI clamps (GI clamps inclusive in this item only and nothing extra should be paid for clamps) and each CI pipe should be minimum 10 cm apart from wall and fixed by using GI clamps placed at 2 m apart throughout the height of bldg (GI clamps inclusive in this item only and nothing extra should be paid for clamps)
S&F in repairs 75 mm dia bore spun type cast iron soil waste and vent pipes in any length with or without ears, with cement joints fixed to walls or laid in trenches complete all as specified and as directed Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 and the two CI pipes should be minimum 5 cm apart from each other with or without using GI clamps (GI clamps inclusive in this item only and nothing extra should be paid for clamps) and each CI pipe should be minimum 10 cm apart from wall and fixed by using GI clamps placed at 2 m apart throughout the height of bldg (GI clamps inclusive in this item only and nothing extra should be paid for clamps)
S&F in repairs75 mm dia bore spun cast iron bends diminishing pieces or traps as directed by Engr-in charge
S&F in repairs 100 mm bore cast iron bends,diminishing pieces or traps as directed by Engr-in-charge
M&L for sealing/grouting around pipe penetration of toilets/kitchen/bathrooms by chipping and exposing sides of pipes and grouting with 1:4 cement plaster mixed with integral waterproofing compound complete all as specified and as directed by Engineer-in-Charge.
M & L for protection screed 1:2:4 in 30-40 mm thickness laid to be admixed with integral waterproofing compound confirming to IS 2645 at the rate of 0.10 kg per bag of cement complete all as specified and directed by Engineer-in-Charge. Note : Integral waterproofing compound to be paid separately under appropriate item
M & L for removing and refixing the false ceiling boards/vertical ply boards any type for rectifying or renewing the CI connections/traps etc complete all as specified and directed by Engineer-in-Charge
Excavation in post holes (or similar holes ) in soft /loose soil each n exe 0.5 cu.m , gettting out, returning, filling in and ramming earth or broken rubble mixed with earth around , in layers not exeeding 25cm, watering, and removing surplus soil to a distance n exe 50 m and making good surface complete all as specified and directed by Engineer-in-Charge
S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exe. 5 cm long and diameter of neck is 5 to 10 mm complete all as specified and directed by Engineer-in-Charge
Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) complete from the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators,sockets,light fittings etc for credit and making good the disturbed surfaces of wall, floor etc complete all as specified and directed by Engineer-in-Charge
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:-
One light/Exh fan/ceiling Fan point controlled by one No one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on Ind board
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
All as per item No 182 above but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4.0 Sqmm single core stranded copper cable for one power point on independent board. Note:- for Item 182 & 183: (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above. (iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC.
M&L switch Modular type 6 Amps 1Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
M&L for switch modular type 6 amp SP two way, 1 module ISI marked
M&L for Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
M&L for Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
M&L for switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
M&L for Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
M&L for modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge.
M&L for bell electric (dingdong) 230 volt, SP complete all as specified and directed by Engineer-in-Charge
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed by Engineer in charge.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed by Engineer in charge.
Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. complete all as specified and directed by Engineer in charge.
S&F of decorative type wall mounted luminaire(comet type) with 1 x 14 Watt LED bulb fixed complete all as directed by Engineer in charge.
M&L for angle Lamp holder with metalic ring, pvc/ polycarbonate type back plate with LED bulb 09 watt, 900 lumens out put, 6500K suitable for B-22 base all as per directed
Supply and fix surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz, with copper bus bar ,neutral link earth link complete all as directed.
Supply and fix MCB SPN 40-63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply and fix MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
M&L for Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories(Concealed) in walls all as specified and as directed by Engineer in charge.
M&L for drawing new surface Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories in surface all as specified and directed by Engineer in charge.
S&F 35 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 80lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete all as specified and directed by Engineer-in-Charge
M&L for drawing new surface Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories in surface all as specified and as directed by Engr-in-charge.
M&L for point wiring complete with PVC insulated unsheathed cable 1100 V grade multi-stranded IS-694, 1.5 sqmm (nominal area) with copper conductor drawn through and including non metallic rigid PVC conduit 20mm dia medium grade ISI marked and conduit accessories concealed in wall/ceiling/fixed to roof/truss/ columns etc. with sunken type pressed steel mild steel boxes made out of 1.6 mm thick mild steel sheet concealed in wall and cover with 3mm thick laminated sheet for mounting of switches, socket outlets, regulators etc, complete including provision of PVC insulated unsheathed 1.5 Sqmm stranded copper conductor as earth continuity conductor and connecting to common earth dolly for the following:- Note :- (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above. (iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC.
One light /Ceiling fan/exhaust fan/ bell point controlled by one switch.
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on Ind board
M&L switch piano flush type 5 amp SP one way complete all as specified and directed by Engineer-in-Charge
S & F switch piano, flush type, single pole, TWO way, 5 Amps 230Volts ISI Marked complete all as specified and directed by engr-in-charge
M&L socket outlet 5 Amps 5 pin flush type ISI marked complete all as specified and directed by engr-in-charge
Supply & Fix fan regulator electronic step type 5 steps piano type, one module connecting complete all as specified and directed by engr-in-charge
S&F ceiling rose, PVC poly carbonate, isolated body with three terminals complete all as specified and directed by engr-in-charge
S&F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed by engr-in-charge
S&F MCB DB SPN 02 way, single door 240 V AC 50Hz ,MCB SPN as incomer / out going complete all as specified and directed by engr-in-charge
S&F MCB SPN 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by engr-in-charge
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron steel wire of 4mm dia by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 5 of MES schedule Part-I connecting to earthing test point and testing on completion with including 15mm bore light grade GI protection pipe, RCC 1:2:4 type B1 20mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing lead from earth plate to eqipment to point (up to 7.5M long) common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed by engr-in-charge.
All as per item No.201 herein before but with 4 sqmm single core multi stranded copper conductor cable for one 3 pin 15 Amp switch socket outlet on independent board and using 4 sqmm PVC single core multistranded copper conductor cable as earth wire complete all as specified and directed by engr-in-charge.
M& L Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and directed by engr-in-charge.
S & F switch piano, flush type, single pole, one way 15 Amps 230 Volts complete all as specified and directed by engr-in-charge.
Supply and fix LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours , Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed by engr-in-charge.
S&F in repair MCB DB SPN 04 way, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed by engr-in-charge.
S & F sheet metal enclosure single pole and Neutral with a two pin earth plug top and socket complete with a MCB SP 20 Amp, "C" Curve 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed by engr-in-charge.
M&L for Sub main wiring complete with FRLS PVC insulated unsheathed stranded copper conductor wire 6 Sq mm 02 Nos. (for Phase & Neutral) along with earth wire FRLS PVC insulated unsheathed stranded copper conductor wire of size 6 sq mm wire drawn through in & including PVC conduit 20 mm dia medium grade ISI marked including all fitting accessories concealed in wall/roofs/ceilings etc complete all as specified and as directed by Engr-in-charge.
S&f fresh air fan PVC body AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete all as specified and directed by Engr-in-Charge.
Supply & Fixing of ceiling fan 1200mm sweep, 230 Volt, white colour, ISI mark, rated Air delivery >220 cum/min, complete with all accessories, nuts bolts, clamps, down rod, complete all as specified and directed by Engr-in-charge.
M&L for breaking old existing wall and making provn of a round hole for fixing of 300/450 mm sweep exhaust fan including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed.
S&f exhaust fans metal body, AC single phase 230/240 V of size 300 mm sweep with lorever shutter for fixing of exhaust fan complete all as directed by Engr-in-Charge.
S&F wall mounted fan 400 mm sweep, aerodynamic designed, air delivery ≥ 70 CMM, thermal over load protected motor, 3 blade white colour, 230 volts, 50 Hz, 1420 RPM with 90 degree oscillation and having speed & oscillation control by two pull cords system complete all as specified and directed by Engr-in-charge ”
M&L for Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories(Concealed) in walls all as specified and as directed.
S&F factory made epoxy powder coated Distribution Board TPN 4 ways (TPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN MCCB as incomer and 12 SP or 4 No TP MCBs as outgoing complete all as specified and conforming to IS : 86230 complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 100 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by engr-in-charge.
Note :- Total amount of Sch of credit is Rs. 158671.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
R S ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .