| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹32.0 L+₹4.6 L (17.0%)Rejected-Finance MB NO 180 MG ROAD JUNGLIGHAT PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance The Being Not Lowest | |
| 3 | L3₹34.8 L+₹7.5 L (27.5%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance The Being Not Lowest | |
| 4 | L4₹35.9 L+₹8.6 L (31.4%)Rejected-Finance | L4 | Rejected-Finance The Being Not Lowest | |
| 5 | L5₹36.0 L+₹8.7 L (31.7%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance The Being Not Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
2 Dec 2019, 6:00 pmClosed
Shri Rajiv Ranjan IDSE
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR/MAINT AND CLEANING OF OH RESERVOIR,UG SUMPS AND SEMI UG SUMP AT VARIOUS LOC AND CLEANING OF SERVICE TKS,STATIC TKS AND CONNECTED WKS AND REPAIR/MAINT OF RISING MAIN PIPE LINE,SLUICE VALVE,AIR REL VALVE AND ALLIED WKS IN INS UTKROSH AREA UNDER
2019_MES_292993_1
8796 GE MB PB
Open Tender
Civil Works
Item Rate
180 days
GE, Minniebay, Junglighat (PO), Port Blair -744103
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE, Minniebay, Junglighat (PO), Port Blair -744103
₹60,000
Yes
10 Jan 2020
26 Oct 2019
4 Dec 2019
26 Oct 2019
2 Dec 2019
11 Nov 2019
Amount
M&L for attending of water supply complaints for any leakage/ blockage in GI pipe lines of size 20mm/25mm bore taking up serviceable/ unserviceable GI water pipe line including all fittings/fixtures from trench and supply and laying GI tubing with GI fittings such as GI socket /Nipple/union socket / Tee /reducer etc. 20mm/25mm bore with necessary cutting, threading complete all as specified and as directed. Note: Excavation earth work above 1 mtr shall be measured and paid separately under relevant items of this schedule.
Ditto all as per item No 01 here-in before but for size 40mm /50mm bore GI pipe line.
Ditto all as per item No 01 here-in before but for size 80mm /100mm bore GI pipe line.
Ditto all as per item No 01 here-in before but for GI pipe lines/MS ERW pipe of dia 150mm / 200 mm in trenches/ road, including cutting, welding and painting with black paint after finishing of work complete.
Ditto all as per item No 01 here-in before but in MS ERW pipe of dia 600mm in trenches/ road including cutting, welding and painting with black paint after finishing of work complete.
Excavating in trenches in soft/loose soil, n exc 1.5m wide and n.exc 1.5m in depth for laying of pipes etc n exc 10 Sqm on plan and getting out all as specified and directed.
Ditto all as per item No. 6 above but in hard / dense soil
Returning, filling in using excavated soil including spreading, levelling watering and well ramming in layers n.exc 25cm in any type of soil all as specified and directed.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point in any type of soil.
Supplying, laying or fixing in replacement, GI water tubing, medium grade, of following sizes confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, union, connectors, elbows, reducers, etc laid in trenches / floors or fixed to walls / ceiling / roof etc including testing etc complete all as specified and as directed :- (a) 20mm dia
(b) 25mm dia
(c) 40mm dia
(d) 50mm dia
(e) 80mm dia
(f) 100mm dia
Supply and fixing in replacement Gun Metal, globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed for following size :- (a) 20mm bore
(b) 25mm bore
(c) 40mm bore
(d) 50mm bore
(e) 80mm bore
S&F in replacement of sluice valve of following bore with stainless steel spindle and iron wheel head long body class PN 1.6 with rubber gaskets, nut and bolts of suitable size, ISI marked conforming to IS-14846 complete including dismantling of unserviceable valve all as directed:- (a) 80mm bore
(b) 100mm bore
(c) 150mm bore
(d) 200 mm bore
S&F in replacement joint with rubber or fibre board gasket (flange joints) suitable for flanged pipes and fittings of the following sizes:- (a) 80mm dia
(b) 100mm dia
(c) 150mm dia
S&F rubber gasket joint suitable for spigot and socket pipes and fittings for the following size as specified and directed. (a) 80mm dia pipe
(b) 100mm dia pipe
(c) 150mm dia pipe
S&F in replacement of Lead wool joint suitable for spigot and socket pipes and fittings for the following size as specified and directed :- (a) 80mm dia pipe
(b) 100mm dia pipe
(c) 150mm dia pipe
M&L for mild steel, plain, black sheet 3.15mm thick for cover to water tanks, cover to valve chambers, etc and in similar work, as per site requirement welded to frame, cut to size, edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to steel members etc, with plain 40mm lap joints or welded / riveted seams including bending, turning up, mitred angles, stopped ends, outlets including dismantling the existing unserviceable cover all as specified and as directed.
Taking down unserviceable sluice valves and Re-fixing the same in its original position/location with flanged ends including necessary cleaning, resetting & minor repairs for its smooth functioning, any pattern of following sizes:- (a) 80mm dia
(b) 100mm dia
(c) 150mm dia
Repacking stuffing box of sluice valve spindle including taking apart and reassembling of the following sizes:- (a) 80mm dia
(b) 100mm dia
(c) 150mm dia
Taking out sluice valve, refacing, regrinding and refixing including taking apart & complete reassembling of the following sizes:- (a) 80mm dia
(b) 100mm dia
(c) 150mm dia
Demolition of precast block masonry walls built in cement mortar.
M&L for PCC solid block masonry exc 10cm in width type C-1, 1:3:6 using 20mm stone aggregate set in CM 1:6 all as specified and directed.
M&L for rendering 10mm thick in CM 1:4 on fair faces of concrete internal wall surface finished even and smooth without using extra cement all as specified and directed.
M&L for providing cement concrete Type B-1 1:2:4 using 20mm graded stone aggregate as in coping, bedplates, etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. Note: The quoted rate shall include cost of necessary form work required.
M&L for rendering 15mm thick in CM 1:4 mixed with water proofing compound as per manufacturer instruction on fair face of concrete / external wall surfaces finished even and fair complete all as specified and as directed. Note: Cost of water proofing compound is deemed to be included in rate quoted.
Supply only union socket GI medium grade of following sizes :- (a) 20mm dia
(b) 25mm dia
(c) 40mm dia
(d) 50mm dia
(e) 80mm dia
Supply only GI Nipple 6" long of following sizes :- (a) 20mm dia
(b) 25mm dia
(c) 40mm dia
(d) 50mm dia
Supply only GI Tee Reducers medium grade of following sizes :- (a) 40 x 40 x 20mm
(b) 40 x 40 x 25mm
(c) 50 x 50 x 20mm
(d) 50 x 50 x 25mm
Cleaning of service tanks installed on roofs of multi-storeyed buildings at various places by emptying the tanks, removing scale, dirt and all other foreign materials deposited inside nipples, on side of walls and bottom of the tanks by scrapping and brushing with wire brush , and pressure pump, cleaning with bleaching powder slurry and allowed to dry and then washing the tank with fresh water, Checking and removing Airlock if any on next day after cleaning of the tank, cleaning of vegetation, etc, on surrounding RCC slab where the tank is resting and writing on the tank the date of cleaning, capacity of tank, etc, with synthetic enamel paint (size of letter shall be 10 cm high and 6 cm width in white colour) over a black background of size 450mm x 300mm complete all as specified and directed for the service tanks of capacity as below :- Notes :- Rate quoted is deem to be include the following :- (a) Maintenance of Register with details of tanks cleaned with building No, and provisions of signature of Users, JE, AGE, Contractor & Remarks. (b). Service tanks of capacity exceeding 250 ltr but not exceeding 500 Ltr
(b) Tanks of capacity exc 500 Ltrs and not exc 750 Ltrs
(c) Tanks of capacity exc 750 Ltrs and not exc 1000 Ltrs
(d) Tanks of capacity exc 1000 Ltrs and not exc 2000 Ltrs
S&F in replacement Rotational moulded polyethylene (HDPE) Water Tanks, Cylindrical & Vertical Type, double layered, ISI marked, hoisted and fixed in position including provision of 40mm / 25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks carefully complete all as specified and as directed of following capacities :- Note: The old tanks shall become contractors property at rates given in schedule of credit and shall be removed from site at no extra cost to the department. (a) 500 Ltr capacity
(b) 1000 Ltr capacity
(d) 2000 Ltr capacity
S&F in replacement PVC tank cover (Make Sintex) suitable for service over head tank including necessary fixing arrangements of following capacity:- (a) 500/750/1000 Ltr capacity
(b) 1500/2000 Ltr capacity
M&L for painting to GI /CI water pipe line including Sluice valves, NRV etc with two coats of synthetic enamel paint of black colour/shade or approved colour duly preparing the existing painted surfaces to the entire satisfaction of Engineer-in-Charge of any dia of pipes
S&F in replacement Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm-210 gms/25mm-455 gm ) all as specified and directed:- (a) 20mm bore
(b) 25mm bore
S&F in replacement cable PVC insulated sheathed, unarmoured, flat submersible water proof with stranded copper conductor 1100 V grade of size 3 core 6 Sq mm.
S&F in replacement cable PVC insulated sheathed, unarmoured, flat submersible water proof with stranded copper conductor 1100 V grade of size 3 core 16 Sq mm.
S&F in replacement cable PVC insulated sheathed, unarmoured, flat submersible water proof with stranded copper conductor 1100 V grade of size 3 core 35 Sq mm.
S&F in replacement pump set coupling guard made out of 2mm thick CRCA sheet duly painted with one coat of red oxide primer and two coats of signal red synthetic enamel paint and replacement of old rusted nut bolts etc complete all as per direction of Engineer in Charge.
Cleaning of RCC overhead reservoirs/semi under ground sump/suction gallery of following capacity situated at various places under AGE E/M -II Minnie Bay by emptying the reservoirs, taking down the scale/sludge/mud/algae formed including and other foreign materials got deposited on side of walls and bottom of the tanks by scrapping and brushing with wire brush, cleaning with pressure pump, washing with bleaching powder slurry and allowing to dry and then washing and cleaning the tank with fresh water including applying one coat of white wash on internal surface of reservoirs/sumps and written details on tanks like date of cleaning, capacity of tanks etc on the out side of the tank with synthetic enamel paint with letter size 20cm high, 10cm width in white colour, over a black background of size 100 x 60cm all as specified and directed. Note :- i) The photographs of OHR, sumps before and after cleaning be submitted to Engineer-in-charge for records. (a) Semi underground sump of capacity 10000 gallons at INS Utk.
(b) Semi underground sump of capacity 5000 gallons at INS Utk.
(c) Semi underground sump of capacity 25000 gallons at INS Utk.
M&L for taking out of unserviceable open well submersible pump set of 10 to 15 HP capacity, single phase/3 phase 415V 50Hz AC Supply, from the open well at surface treatment plant / fountain Utkrosh area and transporting to civil workshop to carry out the servicing and replacement of the requisite unserviceable spare parts for its smooth functioning by dismantling the same, including rewinding the unserviceable electric motor with super enamelled copper winding wire of suitable/existing size and suitable insulating materials including varnishing and heating in a heat chamber with proper temperature and assembling the pump set, and taking back to site including refixing in its original position, proper alignment for pump and motor and testing on completion to the entire satisfaction of Engineer-in-Charge and painting the complete pump set with one coat of synthetic enamel paint all as specified and as directed. Notes : (a) The cost of spare parts and gland packing shall be measured and paid separately. (b) The cost of replacement of minor parts / items such as nut, bolt, washer, check nuts etc, shall be deemed to be included in the Unit rate of this item. (c) Old unserviceable materials, parts etc, shall become contractor's property and necessary recovery as per Schedule of credit shall be deducted from contractor.
Supply, fixing & testing in replacement non return Valve (NRV) size of 100 mm dia suitable for any type/size pipe supplied and installed complete.
Supply, fixing & testing in replacement non return Valve (NRV) size of 65 mm dia suitable for any type/size pipe supplied and installed complete.
Supply, fixing & testing in replacement non return Valve (NRV) size of 50 mm dia suitable for any type/size pipe supplied and installed complete.
Supply, fixing & testing in replacement Butterfly valve size of 150mm dia supplied and installed complete.
Supply, fixing & testing in replacement Butterfly valve size of 100mm dia supplied and installed complete.
Supply, fixing & testing in replacement Butterfly valve size of 80mm dia supplied and installed complete.
Supply and fixing in replacement Flange suitable for 100 to 150 mm sluice valve fixing on both side including taking down unserviceable flange
Supply and fixing in replacement Flange suitable for 80 mm sluice valve fixing on both side including taking down unserviceable flange
M&L for Notice board of size 0.6m x 0.3m using 0.5 mm thick foam sheet including writing emergency contact name and Number on board , notice board shall be print in red colour only and letters are white colour minimum 76 letters and maximum 90 letters and fixing with rivet r screw including taking down old existing board from site , before make a board demo copy shall be collect from site JE E/M with details all as specified and directed
M&L for Notice board of size 1.8m x 1.2m using 0.5 mm thick foam sheet including writing of DG set/transformer/AC plant/Pumps details as per given format and shall be print in blue colour only and letters are white colour minimum 76 letters and maximum 90 letters and fixing with rivet r screw including taking down old existing board from site , before make a board demo copy shall be collect from site JE E/M with details all as specified and directed
M&L for Notice board of size 1.2m x 0.9m using 0.5 mm thick foam sheet including writing of particular details of E/M installations and shall be print in blue colour only and letters are white colour minimum 50 letters and maximum 70 letters and fixing with rivet screw including taking down old existing board from site , before a board sample shall be collected from JE E/M with details all as specified and directed
Supply and fixing, installation of UV based water purifiers double purification by UF+UV+TDS+RO controller computer controlled operation, filter change alarm, UV fail alarm with purified water storage , storage capacity 7Ltr Hydrostatic tank and purification capacity 15 Ltr/hr fixing on wall with proper screwing and connected pipe line to water cooler necessary required pipe line up to 2 mtr shall be included with water purifier rate all as specified and directed Make : Kent Model : Kent excell + or equivalent in LG/Aquaguard.
M & L for removing existing unserviceable de-humidifier from ASR power house carefully without damage and after removing de-humidifier making well disturbed by using cement concrete and hallow black after fishing of work white wash to be applied two coats all as specified and directed.
M & L dismantling the transmission gear box assembly by decoupling the gear box from engine flywheel mounting as well as from pump mounting taking out the defective and damaged drive gears, reduction gears, shaft assembly, bearing sets, replacing the worn out / defective parts aligning the all the gears properly fixing oile seals and bearing sets, repositioning the gear box with drainage pump engine drive, aligning the spare with pump, starting and testing bring to original position without damage any parts capacity of 156 HP drainage pump all as specified and directed. Note:- The required spare parts will be supplied and paid separately
Supply of following items :-
Supply of input shaft
Supply of hallow pinion T:28
Supply of input wheel T:28
Supply of intermediate shaft
Supply of intermediate hallow pinion T:28
Supply of out put wheel T:56
Supply of output shaft
Supply of bearing 01 set consisting of 6 Nos
Supply of seal 01 set consisting of 2 nos
S&F in replacement of digital soft starter suitable for 15 HP submersible pump removing existing un serviceable starter and fixing new with proper electrical connection including additional wiring etc Make: L&T, cat part No: CSXI-015-41 or equivalent of Havells/ C&S
S&F in replacement of star delta starter suitable for 10 to 12.5 HP submersible pump removing existing un serviceable starter and fixing new with proper electrical connection including additional wiring etc Make: L & T , cat part No : MK 1 SASD,SS96255 or equivalent of Havells/ C&S
Kathir Marketing Services
M/s Ramesh Lal
M/s Karbhagam Sales Agency
Sree Tirumala Enterprises
Island Agency
bansal construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .