Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.0 L+₹1.0 L (4.01%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹27.5 L+₹1.5 L (5.93%)Rejected-AOC PLOT NO 39 SHRI SHIVE NAGAR 05 MOTI BANDHA MACHEDA HARMADA JAIPUR 302013 RAJ | JAIPUR | JAIPUR | RAJASTHAN | 302013 | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹29.8 L+₹3.9 L (14.9%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest Bidder | |
| 5 | L5₹30.8 L+₹4.9 L (18.7%)Rejected-AOC HNO 52B LAXMI PLACE PHASE II DEORI ROAD NEAR MOHANDEV SCHOOL UKHARA ROAD AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-AOC Other than Lowest Bidder |
Tender Value
₹38.4 L
EMD Value
₹76,800
Closing Date
22 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR OF SEWAGE LINE OF GRND INCL OTM ACCN, ADM BLOCK, OFFRS MESS, JCO MESS, SHOPPING COMPLEX, MT, KOTES AND COOK HOUSES AT JAIPUR MIL STN UNDER GE (S) JAIPUR
2023_MES_582532_1
GE (S)/J-76P OF 2022-23 8796/E8
Open Tender
Civil Works
Item Rate
180 days
Jaipur
Class D and a (ii) category
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹76,800
Yes
28 Mar 2023
24 Feb 2023
24 Mar 2023
24 Feb 2023
22 Mar 2023
10 Mar 2023
Amount
Excavation in trenches not exc.1.5 m wide and not exc.1.5 m in depth for foundation or for shafts, walls, manholes etc not exc 10 Sqm on plan and getting out in soft/ loose type of soil complete all as specified and as directed.
All asper item no 1 above but depth exc 1.5 m and not exc 3m complete all as specified and as directed.
All asper item no 1 above but depth exc 3 m and not exc 4.5 m complete all as specified and as directed.
Removal of excavated soil to a distancen n exc. 50m and depositing where directed a level n.exc 1.5m above GL/Starting point complete all as specified and as directed.
Removal of excavated soil to a distancen exc. 50m but not exc 100m and depositing where directed a level n.exc 1.5m above GL/Starting point complete all as specified and as directed.
Returning,filling in, including spreading, levelling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concretebut excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed.
All as per item no 09 but except brick complete all as specified and as directed. Note: Servicable bricks obtained from item No. 8 above to be reused under this item
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:6 on fair face of brick work or concrete surfaces using Water Proofing Compound , finished ever and smooth . complete all as specified and as directed. Note: Quoted Rate to include cost of Water Proofing Compound
M&L for rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair face of brick work of walls, finished fair & even complete all as specified and as directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, fascias, fins and similar works complete all as specified and as directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete complete all as specified and as directed.
M&L for formwork to edges of concrete flats, roofs, floors etc not exc 10cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but not exc 10cm wide for fair finished surfaces complete all as specified and as directed.
M&L for reinforced cement concrete (nominal mix) 1:1½ :3 type A1 using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for precast RCC 1:2:4 type B1 using 20 mm graded stone aggregate for manhole cover including placing & set in CM 1:6 all as specified Including demolition of old RCC manhole covers. Note :- Reinforcement shall be measured and paid for separately.
S&F deformed or twisted MS TMT bar 6 to 8 mm dia , cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia complete all as specified and as directed.
Demolition of stone setting paving of any description or thickness laid bedded and jointed in any mortar from any position complete all as specified and as directed.
M&L for 50 mm thick sandstone slab and jointed over joist ,manholes etc complete jointed in cement mortar (1:4) complete all as specified and as directed.
Demolition of PCC in ground floors and pavings not exc 15cm thickness (below or above ground level ) complete all as specified and as directed.
M & L for cement concrete ( 1:2:4 ) type B-2 using 20 mm graded stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement Note : Forming fair finished channel for drain using extra cement will be measured and paid for separately complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and as directed.
Demolition and breaking up drain pipes salt glazed ware set in CM 100 mm bore pipe complete all as specified and as directed.
Demolition and breaking up drain pipes salt glazed ware set in CM 150 mm bore pipe complete all as specified and as directed.
Demolition and breaking up drain pipes RCC Sewage line pipes /salt glazed ware set in CM 200 mm bore pipe complete all as specified and as directed.
M&L Concrete bed to drain pipes of 100mm Cement concrete 1:3:6 type C-2 including packing under, and haunching against the sides of pipes after they are laid and tested; in, complete all as specified and as directed.
M&L Salt-glazed stoneware drain pipes laid in trenches and jointed as specified and dia of pipe 100mm complete all as specified and as directed.
M&L Salt-glazed stoneware drain pipes laid in trenches and jointed as specified internal dia of pipe 150mm complete all as specified and as directed.
M&L Concrete bed to drain pipes 150mm of Cement concrete 1:3:6 type C-2 including packing under, and haunching against the sides of pipes after they are laid and tested; in, complete all as specified and as directed.
Supply and laying DWC pipe (Double wall corrugated) of class SN-4 , IS-16098 (pt-II) of size internal dia of 100mm laid in trenches and jointed complete with coupter , bends Tee, Reducers etc complete all as specified and as directed. Make : Ultra plus DWC PE Pipe of supreme/Corfit of prince /D-Rex DWC of Astral.
Supply and laying DWC pipe (Double wall corrugated) of class SN-4 , IS-16098 (pt-II) of size internal dia of 150mm laid in trenches and jointed complete with coupter , bends Tee, Reducers etc complete all as specified and as directed. Make : Ultra plus DWC PE Pipe of supreme/Corfit of prince /D-Rex DWC of Astral.
Supply and laying DWC pipe (Double wall corrugated) of class SN-4 , IS-16098 (pt-II) of size internal dia of 200mm laid in trenches and jointed complete with coupter , bends Tee, Reducers etc complete all as specified and as directed. Make : Ultra plus DWC PE Pipe of supreme/Corfit of prince /D-Rex DWC of Astral.
S&F SGSW gully trap square or round mouthed type 'P' of size 150 x 150 mm with CI grating including raising upto plinth protection with PCC 1:2:4 type B-1 and covered with stone slab complete all as specified and as directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel( 1/2 round or 3/4 section ) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 150 mm bore pipe complete all as specified and as directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel( 1/2 round or 3/4 section ) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 100 mm bore pipe complete all as specified and as directed.
Ditto all as per item No 37 above but 200 mm dia pipe
Demolition of pcc in ground floors and paving n. exe 15 cm thickness (below or above ground level)
M&L 75 mm thick PCC type D-2 (1:4:8) using 40mm graded stone aggregate as in sub base / sub floor complete as specified.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete as specified
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cment and pigment including providing and laying 25mm thick sand cushioning complete as specified.
M&L Chequered cement concrete tiles 20cm X 20cm X 25mm thick set jointed and pointed in neat cement slurry in floor with grey cement and pigment over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
M & L for construction of 380mm thick stone masonry soakage wells of size 3.0 m dia x 4.5 m deep complete all as specified and shown in sketch 'A' attached at serial page no 106 and directed by engineer in charge Note:- Sketch 'A' shall be read in reference with with this items and it shall be deemed that unit rate are quoted accordingly inclusive of all excavation/ earth work in any type of soil. PCC / RCC, other cement work, steel/ iron work etc as shown in the sketch.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
MSR INFRATECH
JAGDAMBA CONSTRUCTION COMPANY
Deep Construction Company
SHRI RADHAYSHYAM JHA
Shiv Construction Company
Sh. Manoj Nagar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .