Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹39.4 L+₹44,144 (1.13%)Rejected-Finance 15 GURU RAM DASS COLONY MITHAPUR JALANDHAR | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹39.6 L+₹61,553.90 (1.58%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bid |
Tender Value
₹47.1 L
EMD Value
₹94,260
Closing Date
19 Mar 2022, 6:00 pmClosed
Garrison Engineer (West)
Kabir Road Jalandhar Cantt
SPECIAL REPAIR OF 03 BATHROOM OF BLDG NO 264 OF 987 D REGT WKSP BLDG NOS P 171 P 196 P 214 GUARD ROOM KOTE SIG STORE ARMR SHOP AND PRISONER CELL OF 27 AD MSL REGT AMRITSAR AIR FD AND BLDG NO P 12 OF 405 SATA REGT WKSP UNDER GE (WST) JALAN
2022_MES_503361_1
GE/JAL(W)-64/2021-22
Open Tender
Civil Works
Item Rate
180 days
Jalandhar Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (West)
₹94,260
Yes
22 Apr 2022
24 Jan 2022
26 Mar 2022
24 Jan 2022
19 Mar 2022
7 Mar 2022
Amount
Schedule 'A' Part-I (B/R Works)
Dismantling of brick tiles single layer as in roof covering all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern in roof covering complete all as specified
M&L cutting out cracks to V-section in existing RCC roof slabs or terracing, cleaning out & filling solidly with a hot mixture of bitumen and clean dry sand (1:1) (by weight) complete all as specified
Material and labour for plain cement concrete padding (1:2:4) type B-1 (using 20mm graded stone aggregate) to bring top surface of slab in slope complete all as specified and directed
Material and labour for rendering 10mm thick cement plaster on brick or concrete surfaces in cement mortar (1:4) mixed with integral water proofing compound in the proportion recommended by manufacturer, surfaces finished fair and even complete all as specified and directed. (WPC shall be measured and paid separately under appropriate item of this BOQ).
Supply water proffing compound
Material and labour for applying a coat of hot blown paving industrial bitumen 85/25 at the rate of 1.20 kg/ sqm over a coat of primer @ 0.3 litre per sqm over the roof surface including cleaning surfaces complete all as specified and directed
Material and labour for APP based polymeric membrane minimum weighing 3kg/ sqm and minimum 3mm thick reinforced with polyester non wove fabric (wt. not less than 150 gms/ sqm) laid onbitumen coated surface by forced application complete all as specified and directed complete all as specified and directed
M & L 40mm th. Brick tiles laid on bedding layer of CM 1;3, 15mm thick and joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight ofcement over APP membrane.
All as per Item No 11 above but except brick tiles (cleaning of old reused brick tiles shall be included)
M&L Flush pointing in cement mortar 1:3 on brick tiles laid flat on roof surfaces etc complete all as specified.
Taking down cement plaster of any description on brick or stone walls, including raking out joints, hacking for key scrubbing down with water etc removing surplus spoil out of Defence Land complete all as specified.
Demolition of brick masonry work of any description built in cement mortar including all arches, quoins, pillars etc complete all as specified.
Brick work with sub class 'B' old size bricks straight or curved on plan exc 6 m mean radious built in CM 1:6 complete all as specified.
All as per description of serial item No 16 here in before but except bricks complete all as specified (old bricks dismantled under respective item shall be reused with cleaning of old brick).
M&L 15mm thick cement plaster in cement mortar 1:4 on brick or concrete surface with water proofing compound finished even and smooth without using extra cement all as specified
M&L for preparing new plastered or unplastered wall surfaces and applied two coat of cement base paint over one priming coat all as specified and directed by Engr-in-charge.
S & F 1000 ltr rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of existing tank of any description complete all as specified and ISI Marked
S&F 20mm for ball valve brass high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed
S&F 20mm Gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed.
Taking down steel water tubing and connections, including cleaning for re-fixing 20 mm bore tubing
S&F medium grade steel water tubing, 20mm bore, galvanised with all fittings and fixed complete to walls ceilings, roofs or layed in floors all as specified and directed
Refixing old 20 mm bore steel tubing and connections in new or old position (walls , ceiling, roof, floors , etc.)
S&F for 110 mm PVC (SWR) Rain water pipes single socketed in any length with rubber ring joints fixed to walls including braking up existing pipes complete all as specified and directed
PVC (SWR) bends 110 mm
S&F stack clamps out of 50mmx 5mm flat iron and 16mm dia round iron stays , including bolts and nuts and securing ends of stays to wall and roof all as specified
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa and finished with resin coat @ 150Gm per sqm on both surfaces as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling floor, hearth or wall and ceiling boards (fiber, pulp, isulation boards/slabs/blankets any thickness including cover fillets
Supply and fixing 4mm thick of size 600x600mm HSPC (high pressure steam cured) pre-painted self eembossed textured designer E-classic board to be fixed to GI powder coated grid/section size 600x600 with main runder 38mm x 24mm x 0.9mm and wall angle 19mm x 0.9mm and duly suspended with 4mm dian GI bar hangers or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete etc. FE 410W (Gde E-250) quality-B as specified and directed
Dismantling structural steel work including door, gates but excluding framed truss etc complete all as specified.
S&F structural steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. cutting, drilling and welding complete, drilled for fixing of steel sheeting or other covering. Doors, door frame chowkhats etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing including necessary cutting drilling and welding etc complete all as specified, steel conforming to Fe-410 Gde-E-250 .
S&F in repair welded steel wire fabric supplied and fixed complete to wood or steel members n.exc Wt not exc 4 kg/Sqm all as specified and directed
S&F pressed steel door frame of size 125mm x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed
S&F pressed steel door frame of size 105mm x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed
S&F 35mm thick 2nd class hard wood factory made plain framed, panelled shutters (two panels), with lock rail and panels of 9mm thick BWP commercial ply or of veneered particle board 12mm thick with commercial veneering on both faces with rails and style. The size of rail and stile as per IS: 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L 35mm thick 2nd class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in clause 8.24 (a) of SSR Part-I; supplied and fitted to chowkhats complete all as specified and directed.
S&F galvanized mild steel wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
S&F in repairs galvanized mild steel wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
M&L for hacking out old broken glass (any thickness, size, quality or description) from wooden/ metal frames glazed with putty or fixed with beads complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares n. exc. 0.50 Sqm in each pane complete all as specified and directed.
S&F mild steel, plain black sheet 1.60mm thick as in wall cladding, steel gates and similar work, cut to size, holes punched including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams including bending or turning up, mitred angles etc as required complete all as specified.
S&F butt hinges, medium weight cold rolled mild steel and fixed 100mm long
S&F 200mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised all as specified and directed.
S&F for door 300mm mild steel ordianry rat rail rod pattern spring including roller and roller plate fixed to wooden/steel frame all as specified and directed.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified and directed.
Demolition of cement concrete in ground floor and paving n. exc. 15cm thickness (below or above ground level) complete all as specified and directed.
M&L 20 to 25mm thick machine cut Kota stone in flooring laid over and including 20mm thick screed in cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the colour of stone slab including rubbing and mirror polishing complete all as specified and directed.
M&L 20 to 25mm thick machine cut Kota stone in Dado/Skirting laid over and including 15mm thick screed in cement mortar (1:3) laid and jointed with grey cement slurry mixed with pigment to match the colour of stone slab including rubbing and mirror polishing complete all as specified and directed.
M&L for 15mm thick cement plaster in cement mortar 1:6 on other then fair faces of brick or concrete surfaces finished even and smooth without using extra cement all as specified
M&L for preparation of newly plastered surface of wall and applying two coat of distemper oil emulsion distemper in wall surface including chalk whiting on plastered surface complete all as specified and directed.
M&L for preparation of old plastered surface of walls and applying one coats of cement base paint r complete all as specified and directed.
M&L preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for preparation of new or previously untreated wooden surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Material and labour for preparation of old steel surfaces of any description, over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L for 50mm PCC 1:3:6 type C1 using 20mm graded aggregate as in plinth protection and path finishing the surfaces even and smooth without using extra cement all as specified
M&L for cement concrete type E-2 1:5:10 (using 40mm graded brick aggregate ) as in sunken flooring
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified
M&L for 25mm thick PCC (1:2:4) type B0 using 12.5mm graded aggregate as in sub floor , sub base; concrete surface finished even & rough to receive topping floor/tiles finish/layer complete all as specified.
M&L for non skid joint free ceramic coloured tiles of size exc 0.11 Sqm and not exc 0.18 Sqm, 6-7 mm thick in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
M&L for coloured glazed tiles of size 300x450x6 - 7 mm thick fixed with neat cement slurry in vertical surface to wall pointing in white/coloured cement to match over and including 10 mm thick rendering in CM 1:4, all as specified and directed
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc and removing surplus spoil out of Defence Land complete all as specified and directed
M&L 5 mm thick cement plaster in cement mortar 1:3 on ceiling surfaces finished even and smooth without using extra cement all as specified
S&F squatting pan WC orrisa pattern size 580 x 440 mm white with and including integral foor rest with P or S trap incl provn of lime concrete bedding incl breaking up existing damaged WC seat and connecting flush pipe etc and make good to floor complete all as specifed.
S&F vitreous china urinal bowl type complete incl providing and fixing plugs bedding urinal against wall in CM(1:2) securing urinal to plugs with and incl 60cm long bras scruees, pointing aroung urinal back in cement incl and fixing and flush pipe, grating with coupling and union for discharge add for fix in repairs complete all as specified.
Dismantling of CI pipe 100 mm dia pipe, jointed in cement morter and taking off in treanch
Dismantling of CI pipe 75 mm dia pipe, jointed in cement morter and taking off in treanch
S&F 100 mm dia cast iron or rainforced concrete drain pipes in any length with or with out years, with cement joints, laid in treanch or in floor
S&F 75vmm dia cast iron or rainforced concrete drain pipes in any length with or with out years, with cement joints, laid in treanch or in floor
S&F Bends of 100mm dimnishing pieces or tapers ( larger bore measured)
S&F Bends of 75mm dimnishing pieces or tapers ( larger bore measured)
M&L Cast iron floor trap 75mm dia with grating including jointing to waste pipe fixed in cement contrete type B-1 (1:2:4)
S&F Cast Iron Tee 75 mm Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches
S&F Cast Iron Tee 100 mm Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches
S&F PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement, all as specified and directed
S&F Grating doom 140mm size of PTMT, (Minimum weight 50 gms) all as specified and directed
M&L for Cutting chases, pinning in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth
S&F medium grade steel water tubing, 15 mm bore galvanised with all fittings and fixed complete to walls or layed in floors including taking down of existing tubing and connections all as specified and directed
S&F PVC white low level flushing cistem 10ltrs capacity with all fittings syphonic action push stype with inlet ball valve and float incl PVC flush pipe, ball valve, handle, MS bracket etc complete all as specified. Make-Prayag
S&F waste coupling of PTMT (half or full threaded). (Minimum weight 32mm-45gm/40mm-60gms) add fix in repairs all as specified & as directed.
S&F PVC connection fiber, reinforced 45cm long 15mm in size with brass check nut and PVC washers at both ends complete
S&F 15mm Angle stop valves, fancy type chromium plated, screwed down, high pressure with crutch or butter fly handle screwed at two right angles ends for both iron pipe or for unions and fixed in repairs .
S&F Bib tap cast copper alloy , chromium plated suitable for 15mm bore iron pipe with long body fancy type complete fixed in repairs.
S&F Stop valve 15 mm cast copper alloy chromium plated fancy type with long shank &cup(concealed type) with capstan heads, screwed down, high pressure, with crutch or butterfly handle screwed for 15mm bore iron fixed in repair complete all as specified.
S&F brass chromium plated shower rose of 75 mm size, with or without swivel joints including fixing to steel pipe or union.fixed in repairs
S&F in repairs pillar taps 15 mm CP alloys with capston heads chromium platted screwed down high pressure with or without lettered HOT OR COLD with long screwed shanks and fly nuts screwed for iron pipe anmd fixed.
S&F Brass chhromium plated tubular tower rail 20mm dia , D type, 60cm long between flanges
S&F 500 ltr rotational moulded polythylene water storage tank (Cylindrical vertical with closed top) hosted and fixed in position incl dismantling of existing tank of any description complete all as specified.ISI marked
S&F 20mm stop valves, cast copper alloy, screwed down, high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed .
Taking down chowkats or frame not exc. 1.5 sq m each with shutters (without taking off shutters from the fames)
Taking down chowkats or frame exc. 1.5 sq m but n.exc 4 sq m each with shutters (without taking off shutters from the fames)
S&F PVC solid door frame of size 50mm x 47mm made out of 5 mm plain/colour PVC sheet to be matched with shutter, reinforced with MS square tube, as per specification and drawing in SSR Part-II
S&F Factory made solid Panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. MS frame shall be covered with heat moulded plain cloured PVC 'C' channel having a PVC strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap inserted for top & bottom Rail; Panelling of plain colour PVC sheet to be fitted in M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed togather with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
S&F Butt hinges 100mm, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 compelete all as specified and as directed.
S&F Aluminium handles 125mm , cast type, annodised all as specified and as directed.
S&F aluminium anodised 125mm, barrel tower bolts of extruded section and fixed all as specified and directed
Material and labour for Steel windows 1.25 mm thick Box type (primer coated) ERW hollow ‘P’ section of size 60mmx25mm single rebated comprises of wire mess shutter EWR Sec 50mmx20mm and 1mm thick and two openable leaf consisting two Nos sash bar of ‘T’ section 20mm x 3mm complete welded to frame with one vertical mullion of EWR box type ‘T’ section of size 60mmx25mm and 1.25mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B1 using 20mm graded stone aggregate. (Four Nos for each window) including following fittings welded to framed shutter :- (a) Holdfasts 150mm long 12mmx3mm made to shape per window -04 Nos, (b) Handle of Z Sec 20mmx25mm, 100mm long per leaf-01 No, (c) MS tower bolt 150mm long per leaf -02 Nos, (d) ‘Z’ sec 20mm x 25mm, 100mm long stopper per leaf -01 No, (e) Cleat 55 mm long of hollow square 15mmx20mmx63mm welded to hinges per leaf -01 No, (f) MS pintal hinges of size 75mmx12mm per leaf -02 Nos, (g) Fabrication and fixing arrangement as per drawing No CEJZ/TD-06/07. (Note: Wire gauge shall be measured and paid for separately). All as specified and as directed.
ditto as above item No. 106 but as in glazed skelton shutters.
S&F Steel ventilator, fixed type with glazing bars all as specified
S & F framed work such as grills, gratings, etc .with ends of bars shouldered and/ or riveted , or forget into spikes ; framed guard bars barallel iron doors and similar work conforming to Fe.290.Gde-E-165
M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of wall surfaces complete all as specified and directed by Engr -in-charge.
M&L for prepration of old surfaces of ceiling and applying two coat of white (lime) wash on ceiling complete all as specified and directed by Engr -in-charge.
M&L for preparing new surfaces plastered or unplastered surfaces of walls by applying two coats of oil bound distemper over a coat of primer complete all as specified and directed by Engr -in-charge.
M&L for complete removal of existing treatments by washing, rubbing down and stopping etc on wall surfaces and applied two coat of cement base paint over one coat of primer complete all as specified and directed by Engr -in-charge.
M&L for prepration of old steel surfaces of any description not otherwise described over 10 cm width or grith and applying one coat of synthetic enamel paint complete all as specified and directed by Engr -in-charge.
M&L for Sand filling under floors or in foundations including watering and consolidation as specified and directed by Engineer in Charge.
M&L for PCC 100 mm thick type D-2 1:4:8 as in sub base flooring as specified and directed by Engineer in Charge.
M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658-2006 of 60 cm thickness M35 Grade as specified and directed by Engineer in Charge.
Schedule 'A' Part-II (Internal electrification)
Taking down carefully aluminium / copper point wiring (light / fan / socket or power) complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc. complete and making good disturbed surfaces of walls ceiling etc. all as per existing including white washing, painting all as per existing complete all as specified and as directed.
Taking down sub main wiring of two single core PVC cable PVC insulated 6/4 sqmm size cable including conduit or wooden batten and removing the material from site and making good the surfaces of walls, ceiling etc. all as per existing including white washing, painting all as per existing complete all as specified and as directed.
Taking out unserviceable main switch/DB's complete all as specified and as directed.
Material and labour for concealed point wiring with 1.5 Sq.mm (nominal area) single core PVC insulated and unsheathed, FRLS cable, multi-stranded, copper conductor cable 1100 Volts grade with universal colour code (Phase & Neutral), drawn in and including PVC concealed conduit medium grade (ISI marked) with accessories like bends, tee junction boxes fixed on wall, ceiling etc. with sunk mild steel pressed terminal box 1.6mm thick sheet duly painted with two coats of black bituminous paint over a coat of red oxide primer and providing 3mm thick laminated bakelite sheet top cover including earth wire of PVC insulated FRLS cable, copper conductor multi-stranded, 1.5 Sq.mm size in green colour, for one light / call bell / fan point controlled by one, one way switch complete all as specified and as directed.
All as per Ser item No.129 above but for 5 amps socket on independent board complete all as specified and directed.
All as per Ser item No.129 above but for 5 amps socket on same board complete all as specified and directed.
Supply and fixing switch piano flush type, 15 Amps, AC, single pole, one way, 230 Volts (ISI Marked) complete all as specified and as directed.
Supply and fixing switch socket outlet multipurpose flush type 5 Amps, AC, 5 pin, single pole, one way, 230/250 Volts (ISI Marked) complete all as specified and as directed.
Supply and fixing switch piano flush type, 15 Amps, AC, single pole, one way, 230 Volts (ISI Marked) complete all as specified and as directed.
S&F socket 6 pin, 15 Amps, flush type, multipurpose, 230/250 volts, AC with ISI marked
Taking out unserviceable sub main wiring any type/size
All as per Ser item No.129 above but with 2.5 sqmm multistanderd conductor FRLS cable with 1.5 Sqmm earth wire for one 6 pin socket 15 Amps on independent board complete all as specified and directed.
Material and labour in repair sub main wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through PVC rigid non metallic conduit including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation complete all as specified and directed. Note: Two runs of cable 4.0 Sqmm, one run of cable 4 Sqmm and one run of PVC conduit will be measured as one unit RM.
S&F in replacement LED tube light fitting 20W retofit including LED lamp with 2100 lumen output with internal surge protection device of 4KV with voltage band of 140-280V CRI-6500K (white light) fixtures box type with retrofit LED rod 20 watt and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete all as specified and directed
Supply and fixing lamp holder PVC, insulated body with back plate suitable for batten fittings including LED lamps 7 watt complete all as specified and directed.
Supply and fixing Exhaust fan AC, 230/240 volts of size 300mm sweep, heavy duty, metal body with louvers/ shutter and connecting with 3 core 1.5sqmm copper conductor PVC insulated wire from fan to ceiling rose
S&F pressed sheet metal encloser (MCB DB), single phase and neutral with 200 amps rated bus bar, single door type, 240 volts including grounting in wall and connecting complete for 4 way
S&F MCB SPN 32 Amps, 230 volts AC and connecting using suitable size of wire all as specified and directed
S&F MCB SP 6 to 32 Amps, 230 volts AC and connecting using suitable size of wire all as specified and directed
Supply and fixing in replacement LED street light fitting 60W including LED lamp pressure die cast aliminum IP-66 with surge protection device of 10 KV, IK7 LED (SEOUL) 6500 and connecting including all fittings as specified and directed by Engr-in-Charge
M&L for sub main wiring with two single core PVC insulated and unsheathed cable 6 Sqmm with multi standard copper conductor, FRLS type cable drawn through and including PVC concealed conduit not less than 20mm in size complete with all accessories alongwith provn of 6 Sqmm PVC insulated and unsheathed, multi standered copper conductor, FRLS type cable as earth wire
Supply and fixing stepped socketed type electronic fan regulator flush type and connecting up complete 230/250 volts as diredcted by Engr-in-Charge
Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm having 3 terminals, PVC polycarbonate and isolated body complete all as specified and as directed.
Supply and fix recess/ceiling mounting LED light 1x36 Watt cool white ligh of 6500K complete all as specified and directed
Supply and fix V3 wall fan AC single phase 230/240 volts of size 450mm sweep with jerk free isolation complete all as specified and directed
Supply and fix ceiling fan, AC 230/240 V, of size 1200mm sweep all as specified and directed
Supply and fix MCB DB, TPN 6 way double door with suitable 200 amps rated bus all as specified and directed
S&F isolator TPN 100 Amp complete all as specified and directed
Supply and fix DB, double door, SPN 8 way for MCB, 240 volt with 200 amps rated bus bar
S&F MCB SP 6-32 amps 240 volts
S&F MCB SPN32 to 63 amps 240 volts
Material and labour for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick burned directly in gound (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal gound level connected to GI earth wire will be protected by 15 mm dia GI pipe light grade watering pipe 20mm dia GI light grade GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation and earth wire connected to O/H continious earth wire on pole, testing the earthing after completion all as specified and directed Note: Result should be less than 03 Ohm
Supply and laying GI tube med grade 50mm dia all as specified and directed
Taking down XLP insulated armoured electric cable any type/size
Taking down XLPE insulated, armoured heavy duty electric cable with aluminum conductor, 1100 volts grade, cross sectional area 4 core 50 Sqmm on floor/wall including lugs & fitting
Excavation in trenches in soft/ loose soil n. exc. 1.50 mtr wide and n. exc. 1.50 mtr in depth for laying of cables and getting out complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25 cm thick each layer complete all as specified and directed.
Supply and spread river sand in trencesh as cable cushioning 8cm below cables and 15cm above the cable all as specified and directed
Removing excavated material n .exc 50 m and depositing, where directed at a level n. exc 1.5 m above the starting point complete all as specified and as directed.
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/ abutting each other complete all as specified and directed.
Supply and fix single pointed air termination rod 12mm dia, 300 mm long including necessary fixing arrangement of suitable size of frame complete all as specified and directed
Supply and fix copper strip 25mm x 3.15mm complete with saddles and fixing screws for fitting the strip complete all as spcified and directed
Supply and fixing gun metal test point terminal block of size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw complete all as specified and directed
M/S Kuldip Construction Co.
AAY KAY ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .