| 1 | L1₹42.6 LAccepted-AOC DL 221 3 SALT LAKE SECTOR II KOLKATA 700091 WEST BENGAL | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹42.6 L | L1 | Accepted-AOC Provisional Accepted |
| 2 | L2₹43.0 LRejected-Finance 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | ₹43.0 L | L2 | Rejected-Finance Quoted rate found 2nd Lowest (L2). |
| 3 | L3₹48.4 LRejected-Finance NEW BANSBARI NH 34 PO JHALJHALIA DIST MALDA PIN 732 102 | MALDAH | WEST BENGAL | 732102 | ₹48.4 L | L3 | Rejected-Finance Quoted rate found 3rd Lowest (L3). |
| 4 | Rejected-Technical RAJA SARAT CHANDRA ROAD PURATULI ENGLISHBAZAR DIST MALDA PIN 732101 | MALDAH | WEST BENGAL | 732101 | - | - | Rejected-Technical Upto date professional Tax certificate and challan required |
| 5 | Rejected-Technical MAYURAKSHI ELECTRICAL MECHANICAL DIVISION WEST BENGAL WB | PURULIA | WEST BENGAL | 723101 | - | - | Rejected-Technical Insufficient Credential upto date professional Tax Certificate and Challan required |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
4 Mar 2025, 3:00 pmClosed
SE,PWD Northern Electrical Circle, Malda
Superintending Engineer, P.W. Dte., Northern Electrical Circle, Mangalbari, Malda - 732142.
Setting up of Burn Ward (20 bedded) at vacated portion of old children ward at 2nd floor of Malda Medical College and Hospital - EI works including online UPS system. (Electrical Work)
2025_WBPWD_806378_1
WBPWD/SE/NEC/NIT-04/2024-2025
Open Tender
ELECTRICAL WORKS ORG
Malda
Please refer Tender documents.
5 documents required · 5 mandatory
₹88,000
Yes
O/O, SE/NEC, Mangalbari, Malda.
17 Dec 2025
24 Jan 2025
6 Mar 2025
24 Jan 2025
4 Mar 2025
1 Feb 2025
30 Jan 2025
Amount
Part - I (E.I work) DBs and Panel
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, concealed in wall as per GS. (Make - Legrand/ L&T/ Schneider)
i) 6 Way upto 160Amp MCCB incommer
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS. (Make - Legrand/ L&T/ Schneider)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. (Make - Legrand/ L&T/ Schneider)
ii) 2+4 way
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection as per GS (Make - Legrand/ L&T/ Schneider)
i) 125A FP MCCB
ii) 63A FP MCCB
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS (Make - Legrand/ L&T/ Schneider)
ii) 63A FP
Supplying and fixing 240/415V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connections per GS. (Make - Legrand/ L&T/ Schneider)
i) 6-32 A SP MCB
ii) 40 / 63 A TP MCB
iii) 40 / 63 A TPN MCB
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
LT Panel : SITC of indoor type L.T. Panel Board with SFU as Incomer and SFU as outgoing feeders in a suitable transportable unit, ready for operation on being installed in a fixed position. The Panel board shall be Self-supporting, fully Compartmentalized, Incomming / Outgoing SFU Compartment Should be seperate, floor mounted, indoor type, dust and vermin proof (IP43). Incoming and outgoing cable entry from bottom / top end at rear side / side cable alley. Gland plate (3mm thick) should be two part detachable type. The panel board shall be fabricated from 1.6 mm thick (16 SWG) CRCA sheet and base channel will be 50mm x 25mm x 6mm (painted with Black Japan after de-rusting), with MS angle re-enforced / stiffner of 25 mm x 25 mm x 5 mm for both vertical and horizontal. Lifting hooks shall be provided in each transportable unit. The doors shall be removable type mounted on hinge with key locking arrangement for each compartment. Doors shall be on front and rear side, gasketted (25 x 5 mm) all through. Degree of protection of the board is IP43.
Painting : Panel should be properly degreased, derusted before phospheting. Alkalyed melamine epoxy based powder coated paint to be done by using 7 tank process with minium thickness of 70 micron avg. Shade will be Pebble Grey No. RAL 7032 both inside and outside. Continious GI Earth bus of size 40 x 6 mm to be provided at a hight of 150 mm from the bottom and brought outside of the panel of 75 mm. Depth of the panel : As per approved drawing. C P R I - Type Test Report for the Panel Board (similar type from Manufacturer) for Three phase and Neutral short circuit withstand strength test on main circuit Bus Bars of HBB+VBB for 65 kA rms for 1.0 second with intial peak of 143 kA, 415V, AC, to be furnished.
Termination : Incoming cable termination Bus should be suitable for termination of requisite nos. Ar/Al XLPE/PVC cables. Outgoing feeder terminals should be as per rating.
System Voltage : 415V, 50Hz, RYBN. Control wiring cable size : 1.5 sqmm PVC FR Cu multistrand flexible wire with proper socketting with PVC sleeve & identification ferruling. CT Secondary wiring to be done with 2.5 sqmm PVC FR Cu multistrand flexible wire. (Mk. RR Kabel / Havell's / Polycab/KEI).
INCOMING : 415 Volts 415 Amp, 4 pole SFU incl. S & F 3 nos. DIN type HRC fuse as per rating including electrical connection with the bus-bars - 1No.
BUSBAR : Bus Bar Materials : Electrolytic Gr Copper, 90% & above pure in nature (Certificate from Mfg. with challan to be submitted), semi soft, tined electroplated with heat srinkable PVC sleeve. Size of Bus Bar : Suitable for 630A current rating. Feeder Connection : Electrolytic Gr Tinned Cu Bus Bar : Suitable for 630A current rating. 5.6 Gr Stainless Steel Bolt to be provided for Bus Bar Connection. Bus Bar Support Material : FRP (thickness minimum 10 mm for main bus) Acralyic Sheet / Backelite guard to be provided in front of VBB / Bus Alley.
OUTGOING: i) 415 Volts 125A, 4 pole SFU incl. S & F 3 nos. DIN type HRC fuse as per rating including electrical connection with the bus-bars. -- 4 Nos.
ii) 415 Volts 100A, 4 pole SFU incl. S & F 3 nos. DIN type HRC fuse as per rating including electrical connection with the bus-bars. --- 2 Nos.
iii) 415 Volts 63A, 4 pole SFU incl. S & F 3 nos. DIN type HRC fuse as per rating including electrical connection with the bus-bars. --- 2 Nos.
TERMINATION :- all outgoing terminations are from the rear / side of the panel. Bi-metallic strip to be provided at terminal cable connection point. (Cu-Al Joint)
B) Distribution Wiring & Plug Point
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] [Switch Board Make: Legrand Myrius or similar] [Wire Make: KEI/ Finolex/ Polycab/ Gloster]
i) Avg run 10 mtr.
ii) Avg run 12 mtr.
ii) On Board 6A
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles
i) 19 mm dia 3 mm thick.
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles
i) 25mm dia 3mm thick Polythene Pipe
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire [Finolex/ Polycab/ Havells/ KEI] of the following sizes in the prelaid polythene pipe as per GS.
i) 2 x 1.5 sqmm. + 1 x 1.5 sqmm.
ii) 2 x 2.5 sqmm. + 1 x 1.5 sqmm.
iii) 2 x 4 sqmm. + 1 x 2.5 sqmm.
iv) 2 x 6 sqmm. + 1 x 4 sqmm.
v) 4 x 10 sqmm. + 2 x 6 sqmm.
vi) 4 x 16 sqmm. + 2 x 10 sqmm.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc including supplying sockets, tapes.
i) 2.5 sqmm.
ii) 4 sqmm.
iii) 6 sqmm.
iv) 10 sqmm.
v) 16 sqmm.
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm) flushed in wall as per GS.
i) 300 mm x 200 mm x 65 mm
Supply & Fixing 240 V, 1 nos. 6 A, 5 pin Modular type plug socket with 1 nos. 6 Amp Modular switch with indicator (Make:- Legrand, Myrius) on 3 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand- Myrius or similar)
Supply & Fixing 240 V, 2 nos. 6 A, 5 pin Modular type plug socket with 2 nos. 6 Amp Modular switch with indicator (Make:- Legrand, Myrius) on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Make:- Legrand- Myrius or similar)
Supply & Fixing 240 V, 1 no. 16 A, 6 pin Modular type plug socket with 1 no.16 Amp Modular switch with indicator (Brand approved by EIC) on 3/4 Module GI Modular type switch board with 3/4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand- Myrius or similar)
Supply & Fixing 240 V, 2 nos. 16 A, 6 pin Modular type plug socket with 2 nos. 16 Amp Modular switch with indicator (Brand approved by EIC) on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand- Myrius or similar)
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Make:- Legrand- Myrius or similar)
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand- Myrius or similar)
Supply & Fixing 240 V, 25 A OLP type starter (Brand approved by EIC) on 4 Module GI Modular type switch board flushed in wall incl. S&F switch board and making necy. connections with PVC Cu wire and earth continuity wire etc. [Make: Electron OLP3+]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand- Myrius or similar)
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. (Make:- Legrand- Myrius or similar)
Supply and fixing of Timer DB (for Double AC machines) concealed in wall after cutting the wall & mending good the damages to original finish incl. necessary Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. The Timer DB comprises of following items - i) Double door enclosure (2+10way) with IP42/43 protection - 1No. ii) 240V, 32A SPN (DP) Isolator (Incomer) of - 1No. iii) Digital time Switch - 1No. iv) 240V, 32A, 2 Pole power contactor - 2Nos. v) 240V, 6A DP Toggle switch - 1No. vi) 240V, 25A SP MCB (Outgoing) of Breaking capacity 10kA & 'C' curve characteristics - 2Nos. vii) Copper bar for 'Ph', 'N', 'Earth' - 3Nos. viii) Blank cover plate as required [Make: Legrand/ L&T/ Schneider]
C) Fitting & Fixture
S & D of 240V, 50-55W 1star rated Heavy duty AC ceiling fan with safety wire. Blade Sweep size - 1200mm, RPM - 380. Minimum of Two years warranty. [Orient/ Crompton/ Usha]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop.
S & F of 240V, 90W 1star rated Heavy duty full metal body Wall bracket fan. Blade Sweep size - 450mm, RPM - 1325. Minimum of Two years warranty. [Orient / Crompton / Usha]
Supply of 240V Exhaust fans complete with all accessories having the following Model ( Make -EPC Heavy Duty)
i) 40Watt, Blade sweep 9"( 230mm ), Speed 1370 RPM
ii) 60Watt, Blade sweep 12"( 300mm ), Speed 1370 RPM
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
S & D of 240V, 18/20/22W, 2100lm T8 LED tube light fittings incl. LED tube with all accessories with a minimum of Two years warranty. [Make: Philips, Crompton, Wipro]
i) Single tube fittings (1200mm) with one LED tube
ii) Double tube fittings (1200mm) with two LED tube
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with HW round block and suitable size of MS fastener
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
S & F 10 Watt LED lamp on angle holder for bracket point incl. making necessary Connection S &F 75mm angle batten holder (Anchor Make) incl. S&F of angular Holder. (Make-Philips/ Crompton/ Wipro)
D) L.T. Power Distribution
S & D of 1.1kV grade XLPE insulated LT Al cable with . Aluminium conductor & armoured protecetion [Make: KEI/ Havells/ Gloster]
i) 4 core 150sq.mm (from substation to DG and LT panel)
ii) 4 core 70 sq.mm. (from LT panel to VTPN)
iii) 4 core 25 sq.mm. (from VTPN to HTPN )
Laying of 4core 150sq.mm.
Laying of two cables above 35 sqmm and upto 185 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.
Laying of 70Sq.mm. and 25sq.mm.
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
i) 4 core 25 Sq.mm.
ii) 4 core 70 Sq.mm.
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.
i) 4 core 25 Sq.mm.
ii) 4 core 70 Sq.mm.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables of size
i) 4 core 150sq.mm.
ii) 4 core 70 sq.mm.
iii) 4 core 25 sq.mm.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials, cables of size- 4 core 150 sq.mm.
i) 4 core 150sq.mm.
ii) 4 core 70 sq.mm.
iii) 4 core 25 sq.mm.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below (i) By TATA-Medium GI pipe.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipment to earth busbar including S & F GI (Hot-Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipment with bolts, nuts, washers, cable lugs etc. as required and mending good damages - 4 SWG
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing materials as required - 65 mm dia
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. - 300x50x1.25mm (18SWG) with angle 25x25x3mm iron support
Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support - 300x50x1.25mm (18SWG)
Supply & Fixing of perforated GI cable tray tee with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support - 300x50x1.25mm (18SWG)
Labour charges for dismantling of the existing electrical wiring, DBs, Fittings etc. and shifting to the store room ,
Arrangement for scaffolding by using bamboo, rope etc. as necessary & making standing platform for working outside
SITC of Online UPS
SITC of 30 KVA UPS including Battery Bank of(24000 - 24960) VAH or higher (SMF Battery 12 Volt ) 3ph Input / 3ph Output, static by pass arrangement, compitable with D.G. Set, DSP controlled IGBT based rectifire with minimum 90% efficiency on 100% Load. The UPS shall be provided with active input P.F. Correction system to obtain 0.9 lag at 100% resistive Load, Wave form - Pure sine wave. It Should be capable of operating in 50’c above ambient temprature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by- pass ON, Over temperature. Inbuilt Isolation Transformer of 1:1 ratio connected in Delta- Star Mode . Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation.
Regulated Sealed Lead Acid Battery, Construction type : AGM or VRSLAB in ABS Flame Retardant Rating (12V SMF Battery -I Lot) (Battery Make Amararaja Quntra/Exide Power Safe.Back up time 30 Min at full load.Warranty : One Year on UPS and One Year on SMF Battery on site against any manufacturing defects. Certificate : ISO 9001:2015, ISO 14001:2015, IOS 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/EN50091- l,IEC/EN 60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture) (Make: APC-Schneider Electric / NUMERIC/ Power One/ VERTIV/ Switching AVO/ Powersafe/ Delta/ Better Power/ Postarm)
TERMS & CONDITIONS
(i) The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. (ii) Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. (iii) If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
RASH ELECTRICAL WORKS (BID ID -6193264)
M/S EASTERN ENGINEERING (BID ID -6136606)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx