| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹38.0 L+₹5.9 L (18.2%)Rejected-Finance W D BUILDING JP ROAD BHARALUMUKH GUWAHATI 781009 ASSAM | KAMRUP METRO | ASSAM | 781009 | L2 | Rejected-Finance Other than L1 bidder | |
| 3 | L3₹40.8 L+₹8.7 L (27.0%)Rejected-Finance PRAGARI NAGAR BYE LANE 3 HOUSE NO 05 SATGAON UDAYAN VIHAR GUWAHATI 781171 | KAMRUP METRO | ASSAM | 781171 | L3 | Rejected-Finance Other than L1 bidder | |
| 4 | L4₹46.5 L+₹14.4 L (44.7%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L4 | Rejected-Finance Other than L1 bidder |
| Sl No | Description | Qty | Unit | PK ENGINEERING L2 | M/S VSL INFRA & TRADE L1 | MAC ENGINEERS L3 | M/S SEWAK SINGH L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of old unserviceable flame proof fittings for height not exceeding 20 feet complete all as specified and directed | 60 | Each | 50 ₹3,000 | 50 ₹3,000 | 20 ₹1,200 Lowest | 100 ₹6,000 |
| 2.00 | Material and labour for replacement of Supply and fixing LED light fitting 1x16/20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all accessories , complete all as specified and directed | 25 | Each | 5,950 ₹1,48,750 Lowest | 6,000 ₹1,50,000 | 7,777 ₹1,94,425 | 12,500 ₹3,12,500 |
| 3.00 | Material and labour for replacement of Supply and fixing LED light fitting 2x16/20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant
toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all accessories , complete all as specified and directed | 25 | Each | 8,050 ₹2,01,250 Lowest | 9,000 ₹2,25,000 | 15,000 ₹3,75,000 | 13,500 ₹3,37,500 |
| 4.00 | Material and labour for replacement of CMRI certified LED flame proof well glass Luminaires (FLP-WP)-LM6 dies cast aluminium housing with heat resistant toughed glass IP 65 protection including lamp 35/40 w and all accessories complete all as specified and directed | 10 | Each | 9,500 ₹95,000 | 6,000 ₹60,000 Lowest | 7,450 ₹74,500 | 12,000 ₹1,20,000 |
| 5.00 | Supply and fix in repair switch, flame proof, rotary type, with terminal box in LM6 ,10/16A single pole 250V . complete all as specified and directed | 10 | Each | 2,450 ₹24,500 Lowest | 3,000 ₹30,000 | 3,315 ₹33,150 | 3,500 ₹35,000 |
| 6.00 | Supply and fix in repair switch, flame proof, rotary type, Direct Entry in LM6 ,10/16A double pole 250V .complete all as specified and directed | 10 | Each | 3,150 ₹31,500 | 2,500 ₹25,000 | 2,250 ₹22,500 Lowest | 3,200 ₹32,000 |
| 7.00 | Material and labour for flame proof zone I&II Gas group IIA/IIB weather proof submain wiring with two runs using approved colour coding as per IS zero hologen flame retardent HFFR smoke free non toxic non corrosive PVC insulated unsheathed flexible coppper conductor cable 1.5 Sqmm single core 1100 volts and one run earth wire of 1.5 sqmm in and including ERW stove enamelled black rigid conduit of requied size but not less than 25 mmdia flame proof conduit accessories such tee bend elbow junction box complete all as specified and directed | 50 | RM | 840 ₹42,000 | 300 ₹15,000 | 500 ₹25,000 | 150 ₹7,500 Lowest |
| 8.00 | Supply and fix flame proof zone I&II gas group IIA/IIB weather proof DB SPN 8 way with bus bar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable entries with cable gland suitable for hazordous area and confirming to IS-2147/62 neoprene gasket geree of protection IP 65 suitable for MCB SPN 32 Amps-01 No MCB Sp-6-20-6 Nos complete all as specified and directed. | 1 | Each | 2,200 ₹2,200 Lowest | 45,000 ₹45,000 | 20,500 ₹20,500 | 5,500 ₹5,500 |
| 9.00 | Material and labour for testing of earthing of any type scattared area at various location inside the cantt as per required intervals and submitt individual earth resitance results duly signed by all concern prior to claim payments complete all as specified and directed.
NOTE : (i) Testing of earthing will be done by 3 Pole Fall of potential method.
(ii) Cost of tools and materilas required to perform the test is demed to be included in the rate quoted.
(iii) No payment shall be consider without satisfactory test result duly signed by all concern.
(iv) A register of testing duly maintaining the periodicity location wise and test value shall be maintained and produced on Demand. | 200 | Each Job | 920 ₹1,84,000 | 120 ₹24,000 Lowest | 150 ₹30,000 | 200 ₹40,000 |
| 10.00 | Material and labour in repair for Air termination, single pointed, aluminium rod 12mm dia and 300mm long to be fixed on horizontal lightning conductor with sutable fixing arrangement complete all as specified and directed. | 40 | Each | 360 ₹14,400 | 300 ₹12,000 Lowest | 305 ₹12,200 | 400 ₹16,000 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
29 Jun 2026, 6:00 pmClosed
GE Narangi
GE Narangi C/o 99APO
CERTAIN REPAIR O FLAME PROOF FITTINGS FIXTURES IN AMN SHEDS POL DEPOT AND LIGHTNING PROTECTION OF BUILDINGS, CONDUCTORS, DAY TO DAY MAINTENANCE OF EARTHING AND ALLIED WORKS AT VARIOUS LOCATION UNDER GE NARANGI
2026_MES_770430_1
8240/B/E8
Open Tender
Civil Works
Item Rate
180 days
Guwahati
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Narangi
₹88,000
Yes
19 Aug 2026
8 Jun 2026
1 Jul 2026
8 Jun 2026
29 Jun 2026
22 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of old unserviceable flame proof fittings for height not exceeding 20 feet complete all as specified and directed | 60 | Each | - | - |
| 2 | Material and labour for replacement of Supply and fixing LED light fitting 1x16/20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all accessories , complete all as specified and directed | 25 | Each | - | - |
| 3 | Material and labour for replacement of Supply and fixing LED light fitting 2x16/20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant
toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all accessories , complete all as specified and directed | 25 | Each | - | - |
| 4 | Material and labour for replacement of CMRI certified LED flame proof well glass Luminaires (FLP-WP)-LM6 dies cast aluminium housing with heat resistant toughed glass IP 65 protection including lamp 35/40 w and all accessories complete all as specified and directed | 10 | Each | - | - |
| 5 | Supply and fix in repair switch, flame proof, rotary type, with terminal box in LM6 ,10/16A single pole 250V . complete all as specified and directed | 10 | Each | - | - |
| 6 | Supply and fix in repair switch, flame proof, rotary type, Direct Entry in LM6 ,10/16A double pole 250V .complete all as specified and directed | 10 | Each | - | - |
| 7 | Material and labour for flame proof zone I&II Gas group IIA/IIB weather proof submain wiring with two runs using approved colour coding as per IS zero hologen flame retardent HFFR smoke free non toxic non corrosive PVC insulated unsheathed flexible coppper conductor cable 1.5 Sqmm single core 1100 volts and one run earth wire of 1.5 sqmm in and including ERW stove enamelled black rigid conduit of requied size but not less than 25 mmdia flame proof conduit accessories such tee bend elbow junction box complete all as specified and directed | 50 | RM | - | - |
| 8 | Supply and fix flame proof zone I&II gas group IIA/IIB weather proof DB SPN 8 way with bus bar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable entries with cable gland suitable for hazordous area and confirming to IS-2147/62 neoprene gasket geree of protection IP 65 suitable for MCB SPN 32 Amps-01 No MCB Sp-6-20-6 Nos complete all as specified and directed. | 1 | Each | - | - |
| 9 | Material and labour for testing of earthing of any type scattared area at various location inside the cantt as per required intervals and submitt individual earth resitance results duly signed by all concern prior to claim payments complete all as specified and directed.
NOTE : (i) Testing of earthing will be done by 3 Pole Fall of potential method.
(ii) Cost of tools and materilas required to perform the test is demed to be included in the rate quoted.
(iii) No payment shall be consider without satisfactory test result duly signed by all concern.
(iv) A register of testing duly maintaining the periodicity location wise and test value shall be maintained and produced on Demand. | 200 | Each Job | - | - |
| 10 | Material and labour in repair for Air termination, single pointed, aluminium rod 12mm dia and 300mm long to be fixed on horizontal lightning conductor with sutable fixing arrangement complete all as specified and directed. | 40 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
8240Tender.pdf
Tender Documents • 0.67 MB
BOQ_862787.xls
BOQ • 1.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .