Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹12.7 L+₹4.3 L (51.6%)Rejected-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L2 | Rejected-AOC Higher rate |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
7 Mar 2020, 5:00 pmClosed
GE NEW DELHI
GE NEW DELHI ARMY HOSPITAL R AND R COMPLEX RAO TULA RAM MARG DELHI CANTT 10
REPAIR AND MAINT OF AIR CONDITIONING APPLIANCES WINDOW/ SPLIT/ CASSETTE TYPE AIR CONDITIONER, REFRIGERATIOR, WATER COOLER AT KASHMIR HOUSE, E-IN-Cs BRANCH UNDER GE NEW DELHI
2020_MES_311586_1
GE/ND-81/2019-20
Open Tender
Civil Works
Item Rate
270 days
GE NEW DELHI
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE NEW DELHI
₹30,000
Yes
31 Mar 2020
31 Jan 2020
9 Mar 2020
31 Jan 2020
7 Mar 2020
14 Feb 2020
Amount
Labour for checking and attending complants of ACs, water coolers, Refrigetors etc of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed (any parts required for replacement shall be measured and paid separately under respective items). Note:- (a) The contractor should detail minimum one AC Mechanic & one helper to attend complaints in kashmir House . (b) The complaint should be attended on same day. (c)) If the complaint not attended/not completed on same day recovery will be done as follows:- (i) For first day Rs.200/- (ii) For second day Rs.300/- (iii) For next every day Rs.500/-
Servicing of Window type AC 1.5/2 Ton capacity of any make / model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed
All as per item No 2 above but Split type AC of any type and 1.5/2 Ton capacity complete all as specified and directed
Servicing of three phase cassette type split AC 3.5 to 4.0 Ton capacity of any make / model with indoor and outdoor unit by taking out the AC, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed. Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
Supply only against repairs running capacitor combination 50 mfd + 6 mfd 230 Volt for AC upto 4.00 Ton complete all as specified and directed.
Supply only in replacement Running capacitor 6 mfd 230 Volt complete all as specified and directed.
Supply only in replacement Running capacitor 4 mfd 230 Volt complete all as specified and directed.
Supply & charging gas refrigerant R-22 A/410 A or as existing to Window type/ Split type/ Cassette/ Package type AC up to 4 Ton capacity including removing of leakage if any and testing complete all as specified and directed.
Supply only in replacement starting relay suitable for 1.5/2 Ton capacity AC complete all as specified and directed.
Supply only in replacement over load protector suitable for 1.5 Ton capacity AC complete all as specified and directed.
Supply only in replacement thermostat switch suitable for 1.5/2 Ton capacity AC complete all as specified and directed.
Supply only against in repair item of starting relay suitable for 4.0 Ton capacity AC complete all as specified and directed.
Supply only against in repair item of over load protector suitable for 4.0 Ton capacity AC complete all as specified and directed.
Supply only against in repair item of thermostat switch suitable for 4.0 Ton capacity AC complete all as specified and directed.
Supply and fixing in replacement reciprocating type compressor 1.5 Ton capacity of the same make and model as per existing make ACs complete all as specified and directed. Make : Kirloskar/Carrier/Tecumseh/existing make
Supply and fixing in replacement reciprocating type compressor 2 Ton capacity of the same make and model as per existing make ACs complete all as specified and directed. Make : Kirloskar/Carrier/Tecumseh/existing make
Supply and fixing in replacement Rotary type compressor upto 2 Ton capacity of the same make and model as per existing make ACs complete all as specified and directed. Make : Kirloskar/Carrier/Tecumseh/existing make
Supply and fixing in replacemen of three phase compressor suitable for 3.5 to 4.0 Ton capacity complete all as specified and directed. Make: Kirloskar/Carrier/Daikin/existing make.
Supply only in replacement wiring kit suitable for 1.5/2 Ton capacity AC complete all as specified and directed.
Supply only in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity window type ACs complete all as specified and directed.
Supply only in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity split type ACs complete all as specified and directed.
Supply only against in repair item of air filter synthetic / nylon type as per existing size and shape suitable for 3.5/4.0 Ton capacity cassette type split AC's complete all as specified and directed.
Supply only new fan motor (inoor/outoor) 1/4,1/5 HP single/double shaft as per existing model sutaible for Split type ACs 1.5/2 Ton complete all as specified and directed. Make : LG/Career/Voltas.
Supply only against in repair of fan motor single/double shaft as per existing model suitable for 3.5/4.0 Ton AC's of any make/type complete as per requirement on site complete all as specified and directed.
Material and labour for rewinding of fan motor suitable for ACs up to 4 Ton capacity with super enameled copper winding wire of same gauge including replacement of insulating material, bushes and shaft complete all as specified and directed.
Supply only in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 70/.0076 (2.5 sqmm) complete all as specified and directed. Make:- Kalinga/Polycab/Havells/Finolex
All as per item No 26.00 above but 4 core complete all as specified and directed.
Supply only in replacement condensor fan blade made out of aluminium /plastic suitable for upto 2 Ton capacity window type AC's complete all as specified and directed.
Supply only in replacement condensor fan blade made out of aluminium /plastic suitable for upto 2 Ton capacity split type AC's complete all as specified and directed.
Supply only against in repair of condensor fan blade made out of aluminium/plastic suitable for upto 4.0 Ton capacity cassette type split AC's complete all as specified & directed.
Supply only in replacement of evaporating air blower made out of aluminium/plastic suitable for upto 2 Ton capacity for window type AC all as specfied and directed
Supply only in replacement of evaporating air blower made out of aluminium/plastic suitable for upto 2 Ton capacity for split type AC all as specfied and directed
Supply only against in repair of evaporating air blower made out of aluminium/plastic suitable for upto 4.0 Ton capacity cassette type split AC's complete all as specified & directed.
Supply only against in repair of indoor air blower made out of aluminium/plastic suitable for upto 4.0 Ton capacity type split AC's complete all as specified & directed.
Supply only in replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.
All as per item No 35.00 above but internal dia13 mm (1/2") complete all as specified and directed.
Supply only in replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9 mm ("3/8") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.
Supply only in replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16 mm ("5/8") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.
Material and labour for replacement of front grill suitable for window type ACs upto 2 Ton capacity of any Make as per existing size and shape complete all as specified and directed.
Material and labour for replacement of reverse valve system suitable to 1.5/2 Ton split/window AC for heating option (Gas charging shall be paid and measured under respective item) complete all as specified and directed.
Supply only copper tubing heavy duty inner dia 6 mm (1/4") for refrigerant for Acs complete all as specified and directed.
Supply only copper tubing heavy duty inner dia 13mm (1/2") for refrigerant for Acs complete all as specified and directed.
Supply only copper tubing heavy duty inner dia 9 mm (3/8") for refrigerant for Acs complete all as specified and directed.
Supply only copper tubing heavy duty inner dia 16 mm (5/8") for refrigerant for Acs complete all as specified and directed.
Supply only condensing coil suitable for 1.5/2 Ton split/window type ACs as per existing size/shape and as per existing make complete all as specified and directed.
Supply only evaporating coil suitable for 1.5/2 Ton split/window type ACs as per existing size/shape and as per existing make complete all as specified and directed.
Supply only brass flare nut/connector heavy duty of size 6 mm/9 mm (1/4", 1/2") as per existing make complete all as specified and directed.
Repair to control processing board (Remote control kit) with hand set including replacement of current transformer, ICs, dieods, resistances, sensors etc complete all as specified and directed for 1.5/2 Ton split type ACs of any make & model.
Repair to control processing board (Remote control kit) with hand set including replacement of current transformer, ICs, dieods, resistances, sensors etc complete all as specified and directed for 3.5/4 Ton split type ACs of any make & model.
Supply and fixing in replacement split type AC 1.5/2 Ton indoor PCB unit complete with sensor complete with fixing plate suitable to non inverter type make AC all as specified and directed. Make : Carrier, Blue star, Napolean & Totaline
Supply and fixing in replacement split type AC 1.5/2 Ton indoor PCB unit complete with sensor complete with fixing plate suitable to inverter type model and make AC all as specified and directed. Make : Carrier, Blue star, Napolean & Totaline
Supply and fixing in replacement split type AC 1.5/2 Ton outdoor PCB kit complete with sensor suitable to non inverter type existing model and make AC all as specified and directed. Make : Carrier, Blue star, Napolean & Totaline
Supply and fixing in replacement split type AC 1.5/2 Ton outdoor PCB kit complete with sensor suitable to existing model and make AC all as specified and directed. Make: Carrier, Blue star, Napolean & Totaline
Supply and fixing in replacement window AC kit 1.5/2 Ton PCB with sensor complete with condensing coil, blower and motor suitable to inverter type existing model and make AC all as specified and directed. Make : Carrier, Napolean & Skoda
Supply only air direction changer louver motor ( swing motor) suitable for split type ACs as per existing make and model complete all as specified and directed.
Supply only in replacement cordless Remote for inverter type ACs Hot & cool suitable for 1.5 Ton AC as per sample complete all as specified and directed.
Supply only in replacement cordless Remote for ACs suitable for 1.5 Ton AC as per sample
Servicing of Water cooler of 40,60,120,150,200 ltr capacity of any make / model by cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning, greasing, oiling of fan motor and checking of electric circuit for smooth functioning complete all as specified and directed.
Supply & charging the gas refrigerant R-134 or as existing to water coolers up to 150 ltr capacity including removing of leakage if any and testing complete all as specified & directed
Supply and fixing in replacemen new compressor suitable for 40/80 ltr capacity water cooler reciprocating type complete all as specified and directed. Make:- Kirloskar/Carrier/Tecumseh/Existing make
Servicing of Refrigerators of 165 to 310 ltr capacity single door of any make / model by cleaning of condensing coil with wire & brush to remove dust including checking of electric circuit for smooth functioning complete all as specified and directed.
Servicing of Deep fridger 380 ltr capacity 2/3 door of any make / model by cleaning of condensing coil with wire & brush to remove dust including checking of electric circuit for smooth functioning complete all as specified and directed.
Supply and fixing in replacement new compressor suitable for 280/310 ltr capacity refrigerator reciprocating type complete all as specified and directed. Make : Kirloskar/Carrier/Tecumseh/existing make
Supply and fixing in replacement of new compressor suitable for deep freezer of capacity upto 500 Ltrs, Make : Kirloskar/Carrier/Tecumseh/ existing make complete all as specified and directed.
Supply only in replacement starting relay suitable for 165 to 310 ltr capacity Refrigerator complete all as specified and directed.
Supply only in replacement over load protector suitable for Refrigerator complete all as specified and directed.
Supply only in replacement thermostat switch suitable for Refrigerator complete all as specified and directed.
Supply and fixing of monkey menace protection device with pvc spikes size as per sample all as specified and directed.
Taking down AC of any type,any capacity and any make, dismantling of copper pipe, transportation to work shop for carrying out necessary repair work, transportation back to location of installation , reinstallation/refixing in position after complete repairs as required and making functional including testing complete all as specified and directed.
supply and fix of drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 TR as per sample all as specified and directed
supply and fix of AC box fiber type of 2 module suitable for MCB SPN of any capacity as per sample complete all as specified and directed.
SNOWY ENGINEERING INC
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .