Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.7 L+₹202.66 (0.04%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹4.7 L+₹877.66 (0.19%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹9,700
Closing Date
13 Mar 2024, 1:00 pmClosed
Assistant Engineer PWD RESD
Assistant Engineer PWD RESD
Necessary arrangement for SITC of AC Machines for Medicine store (1st floor) and Equipment store (Ground Floor) located at MSVP office of Rampurhat Govt Medical College and Hospital Rampurhat Birbhum
2024_WBPWD_680303_1
WBPWD/AE/RESD/eNIT-30/2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Wise
15 days
Rampurhat Govt Medical College Hospital
Please refer Tender documents.
5 documents required · 5 mandatory
₹9,700
12 Aug 2024
6 Mar 2024
15 Mar 2024
6 Mar 2024
13 Mar 2024
6 Mar 2024
Amount
Supply, Installtion, Testing and Commissioning of 1.95 Tr - 2.2 Tr Split type AC machines having Cooling Capacity range (6.8KW- 7.7.0 KW) with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating - 3 (EER range 3.5 to 3.99), Air flow range CFM ( 780 - 880), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 ( Part - I & Part - II) with all amendments ( Make - Mitsubishi Heavy/ O-General) [NS]
Supply, Installtion, Testing and Commissioning of 1.5 Tr - 1.6 Tr Split type AC machines having Cooling Capacity range (5.0KW- 5.6 KW) with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating - 3 (EER range 3.5 to 3.99), Air flow range CFM ( 580 - 650), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 ( Part - I & Part - II) with all amendments ( Make - Mitsubishi Heavy/ O-General/Daikin) [NS]
Supply & laying Refrigerant Copper pipe minimum Thicknes1.15 mm. Liquid pipe 9.52 mm (3/8") & Gas pipe 15.88mm (5/8") (Make - Royku/Totaline/Mandeep) and insulation of refrigerant copper pipeping by nitril rubber insulation tube of minimum thickness 9mm.(Make - Aroflex/Acoflex) also raping the insulation & copper wire with GKB Gold raping tape as direction of EIC. [NS]
Supply and drawing 4 core 2.5 sq.mm PVC insulated sheeted wire for connecting the outdoor to indoor communicaion supply. (Make - Havels/Finolex/Polycab/RR/Gloster)[NS]
Supply & laying drain water piping work out of UPVC /HDPE hard pipes of 25mm dia 4mm thick (Make- HB/Supreme) incl. fitting accessories bends,elbows,tees, flanges,tapings etc. [NS]
S&F Timer Control Unit for single phase AC Machine assembled with - 12-way SPN DB Box (L&T / Cabtree/Legrand/Siemens/ABB) - 1 no. 32 A DP MCB Isolator (Make: Siemense / Legrand / L&T) - 01 no. Digital 24 hour time switch (GIC/L&T) - 1 no. 32A three pole contactor (L&T) - 01 no. Centre off 2 way toggle switch - 1 no. 32Amp. Barirrer type terminal- 1 no. LED indicating lamp (L&T: SIL R 240V) - 01 No. 2X4sqmm+2.5sqmm copper wire 0.5 Mtr. with complete interconnection with auto-mannual bypass arrangement with locking arrangement incl. making/cutting door of SPN DB box for fixing arrangement of toggle switch, Locking arrangement, LED indicator etc. as required as per direction of EIC.
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc [PWD/GS Page: E-19 Item: 17] [Make - Legrand/Cabtree/Anchor]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [PWD/GS Page: E-14 Item: 1/a] (Make - Havels/Finolex/Polycab/RR/Gloster)
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes 2 x 4 sq mm + 1X 2.5 sq.mm [PWD/GS Page: F-5 Item: 9 ]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [For AC ] [PWD/GS Page: E-17 Item: 5a] [Make - Legrand/Cabtree/Anchor]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [For AC] [PWD/GS Page: E-17 Item: 5b] [Make - Legrand/Cabtree/Anchor]
Note:- Labour welfare Cess @ 1% and GST @ 18% on Bill amount will be deduct.
BISWANATH CHATTERJEE
RIK ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .