Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC lowest and reasonable | |
| 2 | L2₹10.1 L+₹26,599 (2.71%)Rejected-Finance | L2 | Rejected-Finance not lowest | |
| 3 | L3₹10.1 L+₹33,385 (3.40%)Rejected-Finance | L3 | Rejected-Finance not lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
10 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NAGPUR
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR AND CLEANING OF SEWAGE LINE, SEPTIC TANK AND SOAK WELLS IN ZONE D OTM AREA AT VSN, NAGPUR
2022_MES_507212_1
GE/NAG/21-22/8497/45
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF NAGPUR
As per NIT
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹20,000
16 Mar 2022
10 Feb 2022
12 Mar 2022
10 Feb 2022
10 Mar 2022
24 Feb 2022
60 days
Amount
Taking out [desilting] silt, bricks bats, debris, liquid waste, sludge in solid / semisolid state from the manholes of any size and any location including pumping out sludge wherever necessary, slugging, diverting the flow in the drain, if necessary and staking the removed silt/sludge in deposit away from the edge of manholes as directed including use of safety belt, dry cells torch for lighting in side the man hole and taking similar precautionary measures and removing the sludge to a distance exceeding 250 m but not exceeding 500 m and cleaning the manholes with clean water etc complete all as specified and as directed by Engineer - in - Charge for manholes of following sizes: (Note: (1) Emergency complaints should be rectify within 24 hours as directed by engr-in-charge or JE Civil. (2) Volume of sludge after drained out shall only be measured. (3) Sludge obtained shall become contractors property as per schedule of credit.)
Cleaning of the choking / blockage of floor trap, Gully trap and Nahani Trap upto first manhole and cleaning / washing the area and refixing the grating of gully trap etc complete all as directed by Engineer - in - Charge. (Note: (1) Emergency complaints should be rectify within 24 hours as directed by engr-in-charge or JE Civil.
Cleaning of blocked sewage line of 100 mm dia by using Bamboo sticks or MS Rods and revolving with rope inside the sewer line between two manholes and cleaning the sewer lines with fresh water including taking out sludge complete all as specified and as directed.
All as per item No. 3 above but of 150 mm dia
All as per item No. 3 above but of 200 mm dia
Demolition of cement concrete bed in haunching and breaking up drain pipes any type set in cement mortar of 150 mm dia complete all as specified and as directed.
All as per Ser No.6 above but of 200 mm dia.
All as per Ser No.6 above but of 250 mm dia.
Excavation in trenches n.exc. 1.50 m deep and n.exc. 1.50 m wide in soft / loose soil for drain pipes, manholes etc complete all as specified and as directed.
Returning,filling in including spreading levelling,watering and well ramming in layers n.exc 25 cm thick in layers etc all as completed and as directed.
Removing excavated soil n.exc 50m and depositing where directed at a level n.exc 1.5M above the starting point complete all as specified and as directed.
Clearing the septic tank including inspection chamber and getting out sludge by mechnical equipment or manual and other accumulated materials complete and including refilling the water and disposal of sludge to distance exc 1.5Km but n.exc 5Km complete all as specified and as directed.
Clearing the grease trap including inspection chamber and getting out sludge by mechnical equipement or manual and other accumulated materials complete and including refilling the water and disposal of sludge to distance exc 1.5Km but n.exc 5Km complete all as specified and as directed. Note: - (1) Emergency complaints should be rectify within 24 hours as directed by engr-in-charge or JE Civil. (2) Volume of sludge after drained out shall only be measured. (3) Sludge obtained shall become contractors property as per schedule of credit.)
Demolition of PCC in foundation of under Sewage pipe lines manholes and drains below ground level n.exc. 15 cm thick etc all completed and as directed.
M & L for concrete bed in P.C.C ( 1:4:8), type D-2 (using mm graded aggregate ) to drain pipes including packing under and haunching against the sides of the pipes after laying & testing for 150mm dia pipes all completed and as directed.
All as per Item No.15 above but of 200 mm dia.
All as per Item No.15 above but of 250 mm dia.
Material & labour for 150mm bore reinforced concrete pipes ,class NP2 ,laid and jointed complete with collars all as specified and directed
Material & labour for 200mm bore reinforced concrete pipes ,class NP2 ,laid and jointed complete with collars all as specified and directed
Material & labour for 250mm bore reinforced concrete pipes ,class NP2 ,laid and jointed complete with collars all as specified and directed
Demolition of brick work built in cement mortar including quoins, arches but exlcluding precast articels etc complete all as specified and as directed.
M & L for brick work with old size bricks (sub class 'B' bricks ) straight or curved on plan exc 6 m mean radius built in CM (1:4).
M & L for plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate in foundation for manholes & drains completed all as specified and directed.
M & L for Precast Cement Concrete 1:3:6 type C1 as in manhole covers including form work etc all as specified and as directed.
Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed.
Taking down cement plaster on brick work including racking out joints, hacking for key, scrubbing down with water etc all as specified and as directed by engineer in charge.
M&L 15 mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4 with finished even and fair with out using extra cement all as specified and directed .
S&F 110mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls complete all as specified.
S&F PVC (SWR) bends any radius, 110mm bore, complete all as specified and as directed.
S&F Tee suitable for 110mm dia PVC (SWR) pipe complete all as specified.
S&F PVC (SWR) vent cowl, 110 mm complete all as specified and directed.
S & F in repair 110mm bore PVC (SWR) branch piece single (single Y) equal or unequal all as directed.
S&F in repair 110mm bore PVC (SWR) junction, single (single T) equal or unequal with door access complete all as specified.
S&F 100mm Cast iron soil spun, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls all as specified and directed
S&F CI Bend 75 mm bore (any radius) diminishing pieces or tapers
S&F CI Bend 100 mm bore (any radius) diminishing pieces or tapers
All as per Item No 36 above but with oval access doors .
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement including all necessary concrete work and connecting jobs for making good the area complete all as specified.
M&L PVC(SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement including all necessary concrete work and connecting jobs for making good the area complete all as specified.
S&F in repairs CP bottle trap, 32 mm dia fancy type as approved by engr-in-charge, Complete of Make - Jaguar or equivalent in M/s Parry ware/M/s Johnson including taking down the unserviceable one all as specified and directed.
S&F Stainless steel grating,150 mm dia, with waste hole, of PTMT (minimum weight 40 gms), fixed in repairs, all as specified and directed.
S&F PVC (SWR) pipes, 75 mm bore, single socketed, in any length, with rubber ring joints, fixed to wall all as specified and directed.
S&F PVC (SWR) bends, 75 mm bore all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed.
M&L non-skid coloured ceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, over and including 15 mm screed bed in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles all as specified and directed by Engr-in Charge all as specified and directed by Engr-in Charge
M & L Preparation of Newly plastered external wall surfaces by applying two coats of cement base paint over a coat of primer and complete all as specified and directed
S&F vitreous chain squatting pan, 'Orrissa pattern" size 630x450mm white with integral foot rests, including PVc ' P' or 'S' trap (excluding flushing cistern and flush pipe) complete bedding all as specified and directed.
S&F vitreous china wash down water closet pan (Pedestal pattern), white, including fixing of flush pipe, nut bolts, brackets etc complete all as specified and as directed.
S&F Plastic water closet seat cover, black/white, closed pattern with flat bottom, and cover and mild steel chromoium plated or aluminised hinging devices complete all as specified and as directed.
S&F 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and taking down old one complete all as specified and as directed
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed
S&F in repairs vitreous china urinals,flat back of size 465mmX355mmX265mm,white with grating and union for discharge pipe including connecting to waste pipe complete all as specified and directed.
Harsh Construction Company
M/s DS Khekde
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .