| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAccepted-AOC NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | ₹2.1 Cr | L1 | Accepted-AOC REASONABLE LOWEST BIDDER |
| 2 | L2₹2.1 Cr+₹1.6 L (0.75%)Rejected-Finance | ₹2.1 Cr+₹1.6 L (0.75%) | L2 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 3 | L3₹2.3 Cr+₹15.0 L (7.05%)Rejected-Finance | ₹2.3 Cr+₹15.0 L (7.05%) | L3 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 4 | L4₹2.5 Cr+₹34.4 L (16.1%)Rejected-Finance PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | ₹2.5 Cr+₹34.4 L (16.1%) | L4 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 5 | L5₹2.6 Cr+₹44.1 L (20.7%)Rejected-Finance | ₹2.6 Cr+₹44.1 L (20.7%) | L5 | Rejected-Finance NOT BEING LOWEST BIDDER |
Tender Value
₹2.4 Cr
EMD Value
₹3.1 L
Closing Date
2 Nov 2022, 6:00 pmClosed
Chief Engineer RND Secunderabad
CHIEF ENGINEER RND OPP JBS PICKET SECUNDERABAD
ADDITION / ALTERATION OF CERTAIN CIVIL AND ELECTRICAL WORKS IN SSTC HANGER (BLDG No. 41/1) AT DRDL KANCHANBAGH, HYDERABAD
2022_MES_550747_1
84985
Open Tender
Civil Works
Item Rate
365 days
Kanchabagh Hyderabad
Class B Category a i
8 documents required · 8 mandatory
₹2,000
GE I RND KANCHANBAGH HYDERABAD
₹3.1 L
Yes
1 Dec 2022
8 Sept 2022
9 Nov 2022
8 Sept 2022
2 Nov 2022
13 Oct 2022
16 Sept 2022 - 16 Sept 2022
Amount
Demolition of brick / stone masonry built in cement mortar including all quoins arches, pillars etc complete all as directed by Engineer-in-Charge.
Cutting openings through old masonry walls built in cement mortor for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for underpinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness below or above ground level, removal of rubbish and debris and depositing in low lying areas complete all as directed.
Dismantling of Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed.
Dismantling structural steel work including doors, gates framed trussed etc. complete all as specified and directed. Note: Work shall be carried out upto 12m height.
Taking down chowkhats or frames not exc 1.50 sqm (without taking shutters from the frame) complete all as directed by Engineer-in-Charge.
Taking down chowkhats or frames exc 1.5 sqm but not exc 4.00 sqm (without taking off shutters from the frame) complete all as directed.
Taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc. including making good breakages in taking out and removing from site.
Taking down cement plaster on brick / stone masonry walls, ceilings etc. including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing removing serviceable tiles to store and rubbish off the premises complete all as directed.
Taking down existing roof treatment of any description, any position with bituminous felt including plaster / loose concrete and removing rubbish to a distance exceeding 500m but not exceeding 1000m and roughening the surfaces of old concrete by picking, scraping, cleaning and washing down with water to remove all dust etc complete specified and directed.
Rolled mild steel in roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (RHS, SHS round bars, nuts and holding down bolts etc) including distance pieces, cleats and welding etc confirming to Fe 410-W (Gre E-250 quality-A) complete all as specified and directed. Note: (i) Span of each truss not exceeding 25.0 meter shall be fabricated at site. (ii) Work shall be carried out upto 12m height. (iii) Quoted rates shall be deemed to be inclusive of necessary scaffolding and T&P etc. (vi) The quoted rate shall be deemed to included for cutting, notching, drilling, fitting, revetting / or welding or connecting with nuts and bolts (including rivets or bolts & nuts) providing and fitting angle cleats, fish plates gusset plates etc, also for wedging, plumbing, truing up and fixing complete.
Rolled mild steel sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc confirming to Fe-410-W (Gde E-250 quality-A) complete all as specified and directed.
Rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming to Fe 410-W (Gde E-250 quality-A) all as specified and directed.
All as per Sl item No. 15 above, but fixing only.
Rolled mild steel in plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete confirming to Fe 410-W (Gde E-250 quality-A) all as specified and directed.
Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; will ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles confirming to Fe-290 Gde E-165 complete all as specified and directed.
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe 410-W (Gde E-250 quality-A) complete all as specified and directed.
Mild steel bolts purpose made with hexagonal or square head one end and screwed the other or screwed both ends to be fitted with washers and one hexagonal or square nut complete all as specified and directed.
Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick or any colour having tensile strength of 550 Mpa as in roof coverings / cladding to wall, fixed with self tapping screws complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm as in ridges of an colour having tensile strength of 550Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
600mm dia stainless Steel Turbo ventilators with Polycarbonate base fixed on roof with self tapping screws ete complete all as directed by Engineer-in-Charge.
Preparation of new surfaces of steel or iron surfaces of any description not other wise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coated of red oxide primer complete all as specified and directed.
Mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 (Gde E-165) complete all as specified and directed.
Mild steel, plain black sheet Thickness of sheet in 1.60 mm in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
All as per Sl item No. 26 above, but in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; waters tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size, edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members etc., with plain 40mm lap joints or welded / riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required.
Steel rolling shutters of 1.25 mm thickness of laths with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of zinc chrome primer; erected in position as indicated, complete; gear operated type with chain wheel and hand chain complete all as specified and directed.
Steel ball bearing for rolling shutters complete all as specified and directed.
4 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed.
Plain cement concrete type C1, 1:3:6 (20 mm graded aggregate) as in coping, cills and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed.
Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:4) complete all as specified and directed.
Forming jambs, etc., to openings (to foregoing item), with stone supplied by MES including cutting, toothings and properly bonding into old work, including facing and pointing (if necessary) to match existing work, complete all as specified and directed.
Half brickwork with fly ash bricks old size bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and directed.
Fly ash brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius, built in CM 1:6 complete all as specified and directed.
Providing, precast cement concrete type B1, 1:2:4 (20 mm graded aggregate) as in landings, cover slabs, shelves and similar articles with plain faces including chamfers weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified and directed.
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per Sl item No. 37 above, but 8mm dia.
100mm thick cement concrete type B-0, 1:2:4 (20mm graded aggregate) as in floor including finished floor surface even and smooth with using extra cement complete all as specified and directed.
50mm thick cement concrete type B-0, 1:2:4 (20mm graded aggregate) as in floor including finished floor surface even and smooth with using extra cement complete all as specified and directed.
Treating cement concrete or granolithic concrete surfaces with three dressings or sodium silicate solution complete all as specified and directed.
98 mm width glass dividing strips, 3mm thick and and inserted in position to conform to design complete all as specified and directed.
48 mm width glass dividing strips, 3mm thick and and inserted in position to conform to design complete all as specified and directed.
Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed.
Rendering 5mm thick in CM 1:4 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick on brick or concrete surfaes in CM 1:4 using integral waterproofing compound finished even and smooth without using extra cement complete all as specified and directed. Note: Intergal waterproofing compound shall be measured and paid separately.
Supply only integral water proofing compound complete all as specified and directed.
Brushing neat cement slurry with 3 Kg of cement per Sqm over the RCC slab and sides complete all as directed.
Rendering 10mm in CM 1:3 over concrete surfaces on RCC roof slab and parapets mixed with WPC @ 3% by weight of cement shall be carried out complete all as specified and directed. Note: WPC shall be measured and paid separately.
Water proofing treatment with polymeric standard membrane of weight not less than 3kg per sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150gms/sqm) laid over primed surface by forced application complete membrane shall be fused uniformly by LPG torch flame on horizontal / vertical / slope surface on roof complete all as specified and directed. Water proof treatment consist of as under: - (i) Applying one coat of bitumous primer conforming to IS 3384 @ 0.3 ltrs per sqm. (ii) Laying APP based memberane as specified thickness and weight. (iii) Appplying one coat of bitumen grade 85/25 @1.20Kg per sqm. (iv) Applying two coats of aluminum paint @ 100 ml/sqm over APP membrane.
Light shade of vitrified ceramic tiles 10mm thick (square / rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6, jointed and pointed in white or coloured cement to match with the colour of tiles complete all as specified and directed.
Non skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc over 15mm thick screed bed in CM 1:6, jointed and pointed in white or coloured cement to match with the colour of tiles complete all as specified and directed.
Glazed multi coloured glazed ceramic tiles including border, of size 350 x 250 x 7mm / 450 x 350 x 7mm thick as in vertical surfaces such as dado / skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid on and including 10 mm thick rendering in CM 1:4 on fair faces of brick / concrete surfaces complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer over two coats of internal birla putty smooth finish complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of weather proof antifungal exterior paint over a coat of primer over two coats of external birla putty smooth finish complete all as specified and directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
Anodised aluminium with powder coating to item No. 10087 above to (minimum thickness of powder coating 50 micron) frame work and frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Anodised aluminium door shutters powder coating of any colour (thickness of powder coating not less than 50 micron), aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed.
100mm long butt hinges, extruded aluminium alloy, with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed.
S&F, Continuous (piano) hinges, width of flaps (when open) in 40mm mild steel, bright finish or electro galvanised complete all as specified and directed.
150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and directed.
Extruded aluminium alloy handles 150mm long, fabricated type, anodised complete all as specified and directed.
Door closer hydraulically regulated, designation No. 3, universal type, aluminium (extruded section body) suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
125 mm Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
Mortice lock brass 4 levers vertical type, size 100mm complete all as specified and directed.
5.50 mm Plain sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq.m in each pane complete all as specified and directed.
12mm thick Prelaminatd particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
18/19 mm thick veneered particle board, solid core, interior grade, with decorative face veneers one face complete all as specified and directed.
2nd class hard wood plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
2nd class hard wood plain fillets, coss sectional area not exc 3 sq cm square, rectangular or triangular in section, clean sawn, secured with mills or brads, complete all as specified and directed.
Preparation of new surfaces of wooden of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coated of pink primer as specified and directed.
Anodised aluminium snap grid frame work size of grid 605 x 605mm for false ceiling complete all as specified and directed.
Perforated particle board / tiles for insulation and acoustic purposes, 60 x 60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed.
150mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
150mm dia PVC bends / shoes suitable to PVC rain water pipe including necessary clamps etc fixed on wall complete all as specified and directed.
Vitreous china wash hand basin, white, flat back of size 550 x 400 mm excluding taps, waste, chain and plug and procelain stopper but including bracket and waste fittings, brass, CP 32 mm dia complete fixed in repairs all as directed.
Vitreous china wash down water closet pan (pedestal pattern) (EWC), white including plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device and fixing bolts complete fixed in repairs all as directed.
Vitreous china urinal, half stall type, white, with urinal spreader of chromium type fixing with 15mm dia pipe, bracket, including necessary connection to flush pipe and waste pipe complete fixed in repairs all as directed.
10 litres capacity, PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and suitable flush pipe PVC 32mm dia complete fixed in repairs all as directed.
Towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (minimum weight 190gms) complete fixed in repairs all as directed.
15 mm dia Bib taps, cast copper alloy chromium plated Fancey type with capston head handle, screwed down, screwed for iron pipe complete fixed in repairs all as directed.
15 mm dia stop valves, fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete fixed in repairs all as directed.
15 mm dia fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shank and fly nuts, screwed for iron pipe complete fixed in repairs all as directed.
PVC connections 15mm size with PTMT nuts of length 450mm long complete all as specified and directed.
32mm dia High Density Polyethylene Pipes (HPDE) of pressure rating 6Kgf/cm2 fixed complete to walls, ceiling or in floors etc. complete all as specified and directed.
15mm dia GI steel tubes, medium grade with all fittings & fixtures and fixed complete to walls and ceiling or laid in floors all as specified and directed.
20mm dia GI steel tubes, medium grade with all fittings & fixtures and fixed complete to walls and ceiling or laid in floors all as specified and directed.
25mm dia GI steel tubes, medium grade with all fittings & fixtures and fixed complete to walls and ceiling or laid in floors all as specified and directed.
75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
Grating doom 100 mm dia of PTMT (minimum weight 25 gms) complete all as specified and directed.
Rotational moulded polyethylene water storage tanks of 5000 lit capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Plain Cement concrete type D2 1:4:8 (40 mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Providing and injecting chemical emulsion for post constructional anti-termite treatment along external wall where the apron is nor provided using chemical emulsion at the rate of 7.5 litres per Sqm of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed.
Providing and injecting chemical emulsion for post constructional anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
Providing and fixing, factory made UPVG white colour sliding window three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh sash (42mm x 57mm) sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed.
Taking down cement plaster on brick / stone masonry walls, ceilings etc. including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in soft / loose soil complete all as specified and directed.
Cement concrete type B1, 1:2:4 (12.5 mm graded aggregate) in surface channels and drains complete all as specified and directed.
Rendering 10 mm thick on concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement for surfaces of area drain complete all as specified and directed.
Removal of excavated material exc 500 m and n.exc 1.5 Km and depositing where directed at a level n.exc 1.5 m above the starting point in soils complete all as specified and directed.
100 mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) including finishing surfaces of concrete topping even and fair (without using extra cement) and finishing surfaces of concrete in sub-floors, sub bases, etc. even and rough to receive the topping layer. Finishing surfaces of concrete topping even and fair (without using extra cement) and finishing surfaces of concrete in sub-floors, sub bases, etc. even and rough to receive the topping layer complete all as specified and directed.
Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
S&F, machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade laid with grey cement and no pigment complete all as specified and directed.
Removing building materials to a distance n. exc 1 KM including loading, unloading and stacking at the destination complete all as specified and directed.
RCC M-25 (20 mm graded aggregate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (horizontal or sloping) complete all as specified and directed.
RCC M-25 using 20mm graded stone aggregate as in column including necessary formwork and chiselling old concrete carefully for placing holding down bolts complete all as specified and directed.
Complete removal of existing treatment of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer over two coats of internal birla putty smooth finish complete all as specified and directed.
Taking down old unserviceable point wiring (light, fan, bell, socket or power & highbay light) complete including fixture and fittings such as switches, ceiling roses, regulators, sockets, light fittings etc and making good to the disturbed surfaces of walls, ceilings and floor match the existing shade complete all as specified and directed.
Point wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable voltage upto and including 1100 volts grade multi-standard copper conductor drawn through and including rigid PVC conduit 20mm or higher dia ISI marked as required at site including conduit accessories such as junction boxes, inspection covers etc, surface type on stone / brick masonry walls, roofs, floors etc by means of saddles and clips etc including galvanised terminal boxes suitable for modular switches, sockets etc ISI marked including provision of PVC FRLS insulated 1.5 Sqmm copper conductor cable as earth continuity conductor and connecting to common earth dolly all including good to the disturbed surfaces as specified one light / fan / bell point controlled by one, one way switch / bell push. Note: The quoted rate shall deemed to be included for modular cover plate, frame and metal flush boxes of any type and size.
All as per Sl item No. 116 above, but for 5 Amps socket on independent board.
All as per Sl item No. 116 above, but for 5 Amps socket on same board.
All as per Sl item No. 116 above, but wiring with 4.0 Sqmm for 15 Amps switch socket combination on independent board / two pin earth plug and socket including providing 4.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly.
Modular switch 6Amps, 1 way, 1 module complete all as specified and directed.
2 way modular switch 5 Amps, SP one way complete all as specified and directed.
Modular switch 16Amps, 1 way, 1 module complete all as specified and directed.
Modular socket 6 Amps, 2 in 1 (2/3 pin) 2 module complete all as specified and directed.
Modular socket 6/16 Amps, 2 in 1 (6 pin) 2 module complete all as specified and directed.
Ceiling rose three terminals complete all as specified and directed.
Fan regulator two modular 230 Volts, 120 watt complete all as specified and directed.
Replacement of indoor industrial LED batten type with aluminium housing and integrated electronic driver LED luminaire 1 x 22W complete with all accessories prewired and including connecting up with three core twister flexible copper conductor cable with suitable size complete removing unserviceable fittings complete all as specified and directed. Make: Havells Cat Part. LUMILINE+BS20WLED830SPCSS or equivalent in Wipro / Philips / Bajaj / Crompton Greaves.
Replacement of security light fitting 30 W IP 66 powder coated pressure die cast aluminium compact high power LED security light with heat resistant toughened glass with lense, INDUS SERIES aluminium housing high performance LED complete with and including suitable for el-bend GI pipe 35mm dia, complete removing unserviceable fittings all as specified and directed. Make: Havells Cat Part. VILUMINASL30WLED757PASYBOPC or equivalent in Wipro / Philips / Bajaj / Crompton Greaves.
High bay 120W LED light fittings IP65 protected luminaire robust open type vertical highbay luminous efficiency not less than 150 lm/w, CCT 5700K, voltage range 120-270V AC, electrical insulation Class-1 along with not less than 4 KV surge protection, electronic potted driver inclduing fixing to the ceiling using necessary fastner / hook for hanging the lights and connecting with three core 2.5 Sqmm round copper cable from ceiling rose to the connector of the fitting complete all as specified and directed. Make: Havells Cat Part. BAYBRITEFLAREHB120WLED757APWBBOLTG or equivalent in Wipro / Philips / Bajaj / Crompton Greaves.
Distribution board, MCB DB SPN 8 way sheet metal enclosure double door, factory made, fixed on wall suitable for mounting isolators and MCBs, 240 Volts with 200 Amps rated bus bars, neutral link and earth bar of following capacities including taking down unserviceable distribution board and making good to the disturbed surfaces of wall all as directed.
All as per Sl item No. 128 above, but MCB DB SPN 12 way.
Distribution board, MCCB DB VTPN 12 way sheet metal enclosure double door, factory made, fixed on wall suitable for MCCB incoming and MCB TP and SP out goings, 415 Volts with 200 Amps rated bus bars, neutral link and earth bar of following capacities including taking down unserviceable distribution board and making good to the disturbed surfaces of wall all as directed.
MCB FP, 63 Amps, 415 Volts, 10 KA, 'C' series including removing of unserviceable all as directed.
MCB TPN, 32 Amps, 415 Volts, 10 KA, 'C' series including removing of unserviceable all as directed.
MCCB, 160 Amps, 16 KA, 4 Pole, 415 thermal magnetic, adjustable short circuit over current protection, fixed in distribution board / panel boards including cable providing cable connections, aluminium lugs, glands and testing complete after removing unserviceable item complete all as specified and directed.
MCB 32 Amps, SPN, 240 Volts, 10 KA 'C' series including removing of unserviceable all as directed.
MCB SP 6-32 Amps, 240 Volts 10 KA 'C' series complete all as specified and directed.
Industrial type metal clad triple pole and earth encolsure with a 5 pin metal clad plug and socket 32 Amps complete all as specified and directed.
Single pole and neutral enclosure with a 2 pin and earth plug & socket complete 20 Amps complete all as specified and directed.
Industrial type metal clad triple pole and earth encolsure with a three pin and earth plug with socket 63 Amps complete all as specified and directed.
Sub main wiring with 2 runs of 6 Sqmm single core PVC insulated FRLS unsheathed cable 1100 Volts grade multistranded with copper conductor drawing through rigid PVC conduit medium grade of 25 mm dia including conduit and conduit accessories such as bends, tees, junction boxes concealed / surface type on walls, roof, floors etc including 1 run of 6 Sqmm PVC insulated copper conductor cable as earth continuity wire including taking down unserviceable sub main wiring and conduit complete all as specified and directed. Note: 2 runs of 6 sqmm cable 1 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit.
Sub main wiring with 2 runs of 4 Sqmm single core PVC FRLS insulated unsheathed cable 1100 Volts grade multistranded with copper conductor drawing through rigid PVC conduit medium grade of 25 mm dia including conduit and conduit accessories such as bends, tees, junction boxes concealed / surface type on walls, roof, floors etc including 1 run of 4 Sqmm PVC FRLS insulated copper conductor cable as earth continuity wire including taking down unserviceable sub main wiring and conduit complete all as specified and directed. Note: 2 runs of 4 sqmm cable 1 run of 4 sqmm cable and 1 run of PVC conduit shall measured as one unit.
Sub main wiring with 2 runs of 2.5 Sqmm single core PVC FRLS insulated unsheathed cable 1100 Volts grade multistranded with copper conductor drawing through rigid PVC conduit medium grade of 25 mm dia including conduit and conduit accessories such as bends, tees, junction boxes concealed / surface type on walls, roof, floors etc including 1 run of 2.5 Sqmm PVC FRLS insulated copper conductor cable as earth continuity wire including taking down unserviceable sub main wiring and conduit complete all as specified and directed. Note: 2 runs of 2.5 sqmm cable 1 run of 2.5 sqmm cable and 1 run of PVC conduit shall measured as one unit.
Sub main wiring with 4 runs of 4 Sqmm single core PVC FRLS insulated unsheathed cable 1100 Volts grade multistranded with copper conductor drawing through rigid PVC conduit medium grade of 25 mm dia including conduit and conduit accessories such as bends, tees, junction boxes concealed / surface type on walls, roof, floors etc including 2 run of 4 Sqmm PVC FRLS insulated copper conductor cable as earth continuity wire including taking down unserviceable sub main wiring and conduit complete all as specified and directed. Note: 4 runs of 4 sqmm cable 2 run of 4 sqmm cable and 1 run of PVC conduit shall measured as one unit.
Sub main wiring with 4 runs of 6 Sqmm single core PVC FRLS insulated unsheathed cable 1100 Volts grade multistranded with copper conductor drawing through rigid PVC conduit medium grade of 32 mm dia including conduit and conduit accessories such as bends, tees, junction boxes concealed / surface type on walls, roof, floors etc including 2 run of 6 Sqmm PVC FRLS insulated copper conductor cable as earth continuity wire including taking down unserviceable sub main wiring and conduit complete all as specified and directed. Note: 4 runs of 6 sqmm cable 2 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit.
Earthing complete with copper plate electrode 600 x 600 x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below normal ground level with top edge of earth plate, not less than 1.5 mtr below normal ground level connected to copper strip earth lead of size 20 x 3 mm by means of bolts, nuts / check nuts and washers etc of galvanised iron, protected by galvanised iron pipe light grade 40 mm dia upto a length of 4m away from earth electrode and connected to main switch / control board including necessary excavation earth work in any type of soil and PCC 1:3:6 type C1 for earth chamber, 40 mm thick RCC cover slab 1:2:4 type B1 with 6 mm dia TMT bars at 140 mm cc both ways, watering pipe 20 mm dia light grade GI, funnel, wire mesh, lugs, charcoal and salt etc complete all as shown in electrical plate No. 3 SSR Part I and testing complete including removing unserviceable any type of items complete all as specified and directed. Note: Copper strip and GI pipe 40mm dia beyond 7.5m per earth will be measured and paid separately.
Copper strip of size 20 x 3mm as earth continuity conductor on epoxy insulators including necessary fixing spares as required at site complete all as specified and directed.
M&L for earthing complete with galvanised steel, earth plate electrode 600 x 600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron 32 x 6 mm strip as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron / steel all as shown in electrical plate No. 3 on Page 497 of MES Schedule 2009 Part-I connected to main switch board / main DBs / earthing test point including all necessary excavation and earth work in hard / dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150 c/c both ways and pit / chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40mm dia light grade upto 7.5m from electrode GI pipe to be fixed with complete all as specified and directed.
GI strip of size 32 x 6 mm as earth continuity conductor on epoxy insulators including necessary fixing spares as required at site complete all as specified and directed.
GI tubing 40 mm dia 'light grade' for protection of earth conductor and all as specified and directed.
PVC conduit medium grade of size 20mm dia bore complete all as specified and directed.
PVC conduit medium grade of size 25mm dia bore complete all as specified and directed.
Exhaust fan, steel body AC single phase, 230V of size 300m sweep, 900 rpm, 50 Hz, double ball bearing with four blades, epoxy power coated and frame and louvers complete all as specified and directed. Make: Havells / Almonard / Crompton.
Replacement of recess mounted LED luminaire 36 W, 230 volts, 2' x 2', 5700K CCT, luminous efficacy of not less than 120lm/watt designed for metric false ceiling type or alongwith frame suitable for Armstrong / US Gypsum or similar mounting system with concealed or exposed 'T' sections, glare free light alongwith electronic driver complete with all accessories prewired and including tube rod and connecting up with three core twister flexible copper conductor cable with suitable size complete removing unserviceable fittings complete all specified and directed. Make: Havells Cat Part. PLANO2X2PLR36WLED857S or equivalent in Wipro / Philips / Bajaj / Crompton Greaves.
Air circulator fan 600 mm sweep high speed 230v, 1400 rpm, double ball bearing with three blades, epoxy power coated 50 Hz including fixing arrangement wirth MS bracket frame complete all as specified and directed. Make: Havells / Almonard / Crompton.
Ceiling fan of sweep 1200mm, 370 rpm, double ball bearing with three blades, epoxy power coated 50 Hz, 240volts, of not less than 5 star BEE rating, BLDC dust resistant fan connecting up with three core 1.0 Sqmm cable from ceiling rose including required length of down rod as required at site all as specified. Make: Havells Cat Part No. Efficiencia (BLDC 32W) or equivalet of Bajaj / Crompton.
S&F, air circulator fan 450 mm sweep, 1400 rpm, double ball bearing with three blades, epoxy power coated 230V, 50 Hz including fixing arrangement wirth MS bracket frame complete all as specified and directed. Make: Havells / Almonard / Crompton.
ACB 800Amps, 415V, 50KA, drawout type with microprocessor release IPR-1 (4Pole) inbuilt O/L, S/C & EF protection, fixed in existing panel boards including cable connections, aluminium lugs, glands and testing complete fixed in repairs all as specified and directed. Make: Siemens / L&T / Legrand.
MCCB with rating of 400Amps, 415Volts, 4pole with 35KA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be 100% of ultimate breaking capcity (Icu) including suitable spreader links & connectors as required at site for fixing. MCCB should be with suitable spreaders and phase barriers for each terminals with all accessories complete fixed in repairs all as specified and directed.
Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 sqmm; 3.5 core complete all as specified and directed.
Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm; 4 core complete all as specified and directed.
Supply & lay, cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm; 3.5 core complete all as specified and directed.
Supply & lay, cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm; 3.5 core complete all as specified and directed.
Excavation in trenches not exc. 1.5 Mtr in width and not exceeding 1.5 Mtr in depth for laying of cables and getting out in hard / dense soil etc complete all as specified and directed.
Dry river sand for cushioning to cables in trenches including spreading, levelling complete all as specified and directed. Note: Punned thickness will be measured for payment.
Un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm complete all as specified and directed.
Cutting existing road / PCC of size 45cm x 60cm for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CI using 20mm graded aggregates complete all as specified and directed.
GI tubing 100 mm dia 'light grade' for protection of earth conductor and all as specified and directed.
GI tubing 80 mm dia 'light grade' for protection of earth conductor and all as specified and directed.
GI tubing 50 mm dia 'light grade' for protection of earth conductor and all as specified and directed.
Steel wire mesh cable tray manufactured from steel wires, welded together and bent into final shape prior to surface treatment - electro zinc plated wire mesh cable tray 54mm(H) x 200mm(W) x 3000mm(L), electro galvanised, safe working load 40kg at support distance of 1.5 Mtrs complete all as directed.
High voltage insulation mat having high insulation resistance of class / voltage 11 KV, size (2x1m), thickness 2.5 mm. Fire retardant, high di-electric strength upto 45 Kv for one minute insulation resistance upto 10 Lakh mega ohm confirming to IS 15652:2006, suitable for both AC and DC electrical installations, water and moisture proof, high tensile strength and elongation properties, tested by CPRI.
MCCB 63 Amps, 4 pole, 50Hz, 415 volt with rupturing capacity 25 KA complete all as specified and directed.
Sheet metal enclosure made out of 2 mm thick suitable for MCCB 4 pole, 63 Amps complete all as specified and directed.
Design, supply, install, testing & commissioning electrically operated, overhead traveling (EOT) cranes of capacity to lift 2 Ton, conforming to IS-3177 & IS-807 (latest version) having span of 6 m, height of lift 6 m, travel bay length 60 m suitable for operation on 415 Volts, 3 Phase, 4 wire, 50 HZ supply, double girder complete with necessary steel supporting structure, runway beam with hoist speed 2mtrs/min, cross travel speed 5 mtrs/min & long travel 20 mtrs/min with micro speed 10% as recommended by OEM. The crane inclusive of control panel, power and controlling cables, pendent push button station, radio remote control operation, motors, gear box, rope drum & rope guide, limit switches, bottom block, wire rope, end truck buffer, brakes, wheels, pendent DSL system of shrouded bus bar for LT and pendent festoon for CT including providing platform on both sides of bridge girder with non-skid 5mm thick steel chequered plate along the entire length of the crane, bridge width having 0.5mtr securely fenced with double tired guard rails having minimum height of 1.1mtr.
Access ladder on both side of bay to facilitate maintenance of crane. Both ladders shall be provided with guards to prevent fall and comprising of following components / accessories all as specified and directed. (a) Double Girder box type construction fabricated using fresh tested steel plates conforming to IS: 2062 grade 'A' quality obtained directly from main steel producers such as SAIL, RINL, TISCO. (b) Squirrel cage inductor crane duty motors TEFC, 'F' class insulation suitable capacity conforming to IS: 325 and IS: 123 and as amended upto date suitable for 150 starts per hour and motor shall be heavy duty reversible crane duty type with 40% CDF for hoist, CT & LT to work on AC 415 Volts, 3 phase, 50 Hz. (c) Double shoe DC electromagnetic disc brakes / shoe type brakes / hydraulic thruster type brakes shall be provided in all motions with suitable sizes.
(d) Wheels shall be forged steel made of C55 Mn 75 carbon steel and suitable hardness, double flanged straight tread type fitted with antifriction roller bearing with supported on "L" type live steel axels bearing housing assembly. (e) Wire rope with fibre core of size 8mm dia, having 04 falls conforming to IS: 2266 minimum factor of safey and tensile strength 1960N/mm2 as per ISO: 4309:1990 complete with rope drum fabricated from seamless pipe duly machined and grooved to accommodate full length of rope in one layer. The drum shall be mounted on antifriction hall / roller bearings. Make: Usha, Martin. (f) Gear box of crane shall be totally enclosed in dust proof construction shall be machined from alloy steel and hardened. All gearing is enclosed in a rugged steel housing and initial filling of oil / grease splash lubricated.
(g) Control panel indoor type made out of 2mm thick CRCA dust and vermin proof sheet powder coated painting comprising of variable speed drives (VVVF type) meeting the latest crane control solution enhances crane performances without worries and smooth operation, different operating speed for each process, accurate positioning, suitable switchgears, contactors, meters, relay transformers and components, control wiring etc as per OEM. (h) Control wiring and power wiring, PVC flexible pendent festoon system supported on MS troller for CT and DSL system of suitable rating for LT all as per OEM. (j) Limit switches for upper and lower hoisting. (k) Bottom block shall be equipped with protective guard around the opening, shank type forged hook "C" type, swivelling on thrust bearing tested as per IS 15560. (l) Emergency stop button to shutting off the power to the main contractors shall be provided.
(m) End carriages with standard rolled steel section or welded plate box section type shall be assembled to ensure alignment of bearings and axels, twin drive arrangement, main cross girders to end trucks connection are bolted to ease in assembly. Rubber buffers on all end trucks when a moving crane or trolley reaches the ends of its permitted travel. (n) Hoisting machinery / crab of heavy duty industrial type. (o) Painting of crane with one coat of primer and two coats of synthetic enamel paint of golden yellow of 25 micron. Final touch up will be done after erection at site and writing the details of crane like capaicty, date of installation, load details etc. (p) Pendent push button station shall have push buttons for each motion, bridge light, siren / bell, on and off switches, emergency stop switch and shall be hanged in the middle of girder with chrome plated steel chain duly covered with sleeve. Pendent push button type moving independent of crab along the full length of bridge on separate track.
(q) Radio remote control for all motions and shall have multispeed steps of operation complete with two sets of long life Nickel cadmium batteries and battery charger shall be provided (i.e. one set installed battery +one set spare battery+ one charger) for each radio remote. (r) 03 Nos of LED light fitting 90 watts shall be provided under the girder - 02 Nos and 01 No under CT trolley. (s) Earthing shall be carried out as per IS of quantity as suggested by OEM. (t) Welded joint testing shall be subjected to 10% X-ray testing and X-ray films to be provided for evaluation.
Earthing complete with copper plate electrode 600 x 600 x 3.15mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below normal ground level with top edge of earth plate, not less than 1.5 mtr below normal ground level connected to copper strip earth lead of size 25 x 4mm by means of bolts, nuts / check nuts and washers etc of galvanised iron, protected by galvanised iron pipe light grade 40mm dia upto a length of 4m away from earth electrode and connected to main switch / control board including necessary excavation earth work in any type of soil and PCC 1:3:6 type C1 for earth chamber, 40mm thick RCC cover slab 1:2:4 type B1 with 6mm dia TMT bars at 140mm cc both ways, watering pipe 20 mm dia light grade GI, funnel, wire mesh, lugs, charcoal and salt etc complete all as shown in electrical plate No. 3 SSR Part-I and testing complete including removing unserviceable any type of items all as specified and directed. Note: Copper strip and GI pipe 40mm dia beyond 7.5m per earth will be measured and paid separately.
S&F, GI strip of size 25 x 4mm as earth continuity conductor on epoxy insulators including necessary fixing spares as required at site complete all as specified and directed.
Design, supply, erect, testing & commissioing of motorization including motor & mechanisation equipment for existing mechanical rolling shutter (any size upto 1MT weight) in one single phase 220V, 50Hz, 0.5 HP/400 W unit with 1 Ton lifting capacity by replacing the rolling spring assembly with new cylindrical type rolling assembly with new centre rod connected to the suitable bearing and chain crank in absence of power complete with ball bearing and springs which enable minimum cost of maintenance with single phase push button starter with all connection, copper wiring complete, limit switches, control wiring with copper conductor including necessary dismantling / refixing of rolling shutter, addition / alteration civil works etc., complete all as specified and directed.
Design, supply, erect, testing & commissioing of motorization for sliding gates by providing 2 HP motors, auto stop limit switch and starter complete for existing mechanical sliding shutter (any size upto 1MT weight) in one single unit with 1 Ton pulling / pushing capacity by replacing the rolling spring assembly with new sliding type assembly and in absence of power supply gear free lever switch to be provided for manual pushing complete with ball bearing and springs which enable minimum cost of maintenance with single phase push button starter with all connection, copper wiring complete, limit switches, control wiring with copper conductor including necessary dismantling / refixing of sliding shutter, addition / alteration civil works etc., complete all as specified and directed.
Aluminium strip of size 25 x 3mm complete all as specified and directed.
Test point consisting of terminal box, drilled and screwed with 22 swg GI cover including 2 Nos 12mm dia 25mm long hexagonal head screws jointing GI and aluminium strips with bolts, nuts and washers on and including jointing plate made of gun metal or phosphor bronze of size 90 x 32 x 8mm complete enclosure / terminal block assy grouted in wall at 600 mm height from the length protection level by means of 02 Nos 40 x 40 x 5mm MS plate with 6mm dia anchored bolts embedded in wall including nuts and washers all as specified and directed and shown on drawings.
Single pointed air termination aluminium rod 12mm dia 600mm long and including 40mm dia GI Medium grade support pipe 600mm long, 25 x 6mm MS flat iron clamps, bolts / nuts and washers etc lower end of pipe fitted in a 40mm dia GI socket screwed and welded on and including MS base plate of size 300 x 300 x 6mm thick grouted on top surface of the wall with 4 Nos 12mm dia regged MS bolts / nuts washer etc on GI pipe secured firmly laterally on the wall surface in a vertical manner by means of rugged bolts grouted on the walls including nuts and washers etc upper end of pipe duly plugged lower end of Air termination rod duly jointed / welded with down / horizontal conductor complete all as specified and directed.
Indu Electricals
INDGUARD ENGINEERS
Universal refrigeration and Engineering Company
HARSHITHA INFRA
Maruthi international
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .