Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
15 Sept 2026, 6:00 pmDue today
GE (NW) Mankhurd
GE (NW) Mankhurd
REPAIR MAINT OF INTERNAL ELECTRIFICATION INCLUDING FITTINGS FIXTURES, FLAME PROOF LIGHTS ETC AT TECHNICAL AREA MKD UNDER GE (NW) MANKHURD.
2026_MES_785977_1
8638/E8
Open Tender
Civil Works
Item Rate
270 days
Mankhurd
As per tender document
8 documents required · 8 mandatory
₹500
GE (NW) Mankhurd
₹92,000
Yes
22 Aug 2026
22 Aug 2026
17 Sept 2026
22 Aug 2026
15 Sept 2026
8 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1M & L for point wiring with PVC insulated unsheathed 1100 Volts grade single core FRLS multistranded copper conductor cable 1.5 Sqmm drawn in and including PVC casing-caping and accessories, fixed on wall / ceiling etc with neccessary fixing accessories and earth continuity FRLS multistranded copper conductor cable size connected to common earth and earth dolly including 2 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws including taking down u/s wiring, fittings, switch, sockets etc all as specified for the following: Note:- All points to be made in Hangers/Sheds, hight up to 10 Meters only. | |||||
| 1.1 | (a) For one light, fan, call bell, point controlled by one switch. | 50 | Point | - | - |
| 1.2 | (b) For one socket point controlled by one switch on same board | 20 | Point | - | - |
| 1.3 | (c) For one 5 Amp independent socket point controlled by one switch. | 25 | Point | - | - |
| 2 | All as per item No 1 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, multistranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, multi stranded 1100 volt grade cable as continuous earth lead. | 25 | Point | - | - |
| 3 | M&L circuit wiring in repairs with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 1.5 sqmm drawn in MS Steel conduit with 1.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI marked of size not less than 20 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable wiring complete. Note : 1. M S Conduit/ PVC Conduit will be measured and paid separately. 2. wiring in shed upto height of 6 mtr. 3. Three run of 1,5 Sqmm wire will be measured & paid as one unit.
Make: Apar/ Polycab/ KEI | 200 | RM | - | - |
| 4 | M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 2.5 sqmm drawn in MS Steel conduit with 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI marked of size not less than 20 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete. Note : 1. M S Conduitwill be measured and paid separately. 2. wiring in shed upto height of 6 mtr.3. Three run of 2.5 Sqmm wire will be measured & paid as one unit.
Make: Apar/ Polycab/ KEI | 200 | RM | - | - |
| 5 | M&L sub main wiring in repairs with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 Sqmm drawn in MS Steel conduit with 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI marked of size not less than 20 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete. Note : 1. M S Conduit will be measured and paid separately. 2. wiring in shed upto height of 6 mtr.3. Three run of 4 Sqmm wire will be measured & paid as one unit.
Make: Apar/ Polycab/ KEI | 100 | RM | - | - |
| 6 | S&F in repairs rigid metallic medium 20 mm dia stove enameled steel conduit ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position all as directed by Engineer-in-Charge. | 100 | RM | - | - |
| 7 | M&L sub main wiring in repairs with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 1.5 sqmm drawn in Existing surface/recessed MS Steel conduit/PVC Conduit with 1.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI marked of size not less than 20 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete. Note : 1. M S Conduit will be measured and paid separately if required on ground. 2. wiring in shed upto height of 6 mtr.3. Three run of 1,5 Sqmm wire will be measured & paid as one unit.
Make: Apar/ Polycab/ KEI | 100 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
BOQ_880760.xls
BOQ • 0.52 MB
8638General.pdf
Tender Documents • 0.84 MB
8638Corrigendum.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .