Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | ₹29.6 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹33.3 L+₹3.7 L (12.4%)Rejected-Finance | ₹33.3 L+₹3.7 L (12.4%) | L2 | Rejected-Finance other than lowest bidder |
| 3 | L3₹33.5 L+₹3.9 L (13.0%)Rejected-Finance | ₹33.5 L+₹3.9 L (13.0%) | L3 | Rejected-Finance other than lowest bidder |
| 4 | L4₹35.4 L+₹5.7 L (19.4%)Rejected-Finance | ₹35.4 L+₹5.7 L (19.4%) | L4 | Rejected-Finance other than lowest bidder |
| 5 | L5₹36.4 L+₹6.8 L (22.9%)Rejected-Finance | ₹36.4 L+₹6.8 L (22.9%) | L5 | Rejected-Finance other than lowest bidder |
| Sl No | Description | Qty | Unit | Ashok and Co L3 | Nitika electricals and engineers works L4 | Vijaypower Generators Limited L10 | M/S SALARIA ASSOCIATES L1 | M/S KALSI ENGINEERS AND CONTRACTORS L8 | THAPA TRADERS L5 | ARORA ENTERPRISES L7 | M/S GULATI ENGINEERING WORKS L6 | BMMJ ENGINEERS AND TRADERS L2 | HARSH ELECTRICAL STORE L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling and Inspection complete dismantling of DG set capacities 500 KVA / 625 KVA, inspection of blocks, crankshaft, camshaft, liners, pistons, connecting rods, check cylinder head, valve seats, rocker arms, turbocharger, radiator & pump inspection, alternator etc carrying out to authorised workshop for repair/maintenance of the engine complete for smooth functioning all as per manufacturer's instructions and as directed.
NOTES:- (i) Repair and Maintanance of DG set alongwith connected Alternator and Panel Board including Engine shall be carried out and rectifying the defects by replacing the following unserviceable spare parts as directed by the Engineer-in-Charge.
(ii) Spare parts required for replacement shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be inluded in the rate quoted for this item.
(iii) Cost of all consumables required shall be deemed to be included in the rate quoted for this item. | 2 | Each Job | 40,000 ₹80,000 | 51,500 ₹1,03,000 | 2,50,000 ₹5,00,000 | 1,50,000 ₹3,00,000 | 60,000 ₹1,20,000 | 55,000 ₹1,10,000 | 80,000 ₹1,60,000 | 3,45,000 ₹6,90,000 | 50,000 ₹1,00,000 | 35,000 ₹70,000 Lowest |
| 2.00 | Supply only in replacement of battery terminal for 12 volt as per existing model complete all as specified and directed. | 8 | Each | 150 ₹1,200 | 210 ₹1,680 | 300 ₹2,400 | 120 ₹960 | 500 ₹4,000 | 200 ₹1,600 | 100 ₹800 Lowest | 120 ₹960 | 400 ₹3,200 | 300 ₹2,400 |
| 3.00 | Supply only in replacement of battery cable for 12 volt 180 AH as per existing model complete all as specified and directed | 4 | Each | 1,000 ₹4,000 | 1,150 ₹4,600 | 2,100 ₹8,400 | 500 ₹2,000 Lowest | 900 ₹3,600 | 1,200 ₹4,800 | 500 ₹2,000 Lowest | 666 ₹2,664 | 1,000 ₹4,000 | 1,200 ₹4,800 |
| 4.00 | Supply only of battery terminal 10 ml gel complete all as specified and directed. | 4 | Each Pkt | 100 ₹400 | 90 ₹360 | 45 ₹180 Lowest | 120 ₹480 | 95 ₹380 | 80 ₹320 | 50 ₹200 | 120 ₹480 | 100 ₹400 | 200 ₹800 |
| 5.00 | Supply only in replacement of Benjo bolts of suitable size as per existing model complete all as specified and directed. | 24 | Each | 70 ₹1,680 | 80 ₹1,920 | 60 ₹1,440 Lowest | 150 ₹3,600 | 95 ₹2,280 | 70 ₹1,680 | 100 ₹2,400 | 120 ₹2,880 | 100 ₹2,400 | 150 ₹3,600 |
| 6.00 | Supply only in replacement of fuel pipe filter as per existing model complete all as specified and directed. | 4 | Each | 2,500 ₹10,000 | 2,100 ₹8,400 | 4,500 ₹18,000 | 450 ₹1,800 Lowest | 2,500 ₹10,000 | 2,000 ₹8,000 | 2,500 ₹10,000 | 1,500 ₹6,000 | 1,900 ₹7,600 | 3,500 ₹14,000 |
| 7.00 | Supply only in replacement of Automatic Voltage Regulator (AVR) suitable for DG set of capacity 500 KVA as per existing model complete all as specified and directed. | 1 | Each | 5,000 ₹5,000 | 3,100 ₹3,100 | 42,000 ₹42,000 | 2,500 ₹2,500 Lowest | 3,500 ₹3,500 | 3,000 ₹3,000 | 2,500 ₹2,500 Lowest | 12,000 ₹12,000 | 2,900 ₹2,900 | 10,000 ₹10,000 |
| 8.00 | Supply only in replacement of Automatic Voltage Regulator (AVR) suitable for DG set of capacity 625 KVA as per existing model complete all as specified and directed. | 1 | Each | 6,000 ₹6,000 | 7,100 ₹7,100 | 42,000 ₹42,000 | 2,500 ₹2,500 Lowest | 7,500 ₹7,500 | 6,500 ₹6,500 | 10,000 ₹10,000 | 12,000 ₹12,000 | 6,900 ₹6,900 | 10,000 ₹10,000 |
| 9.00 | Supply only in replacement of Low Oil pressure Switch 12V 1.7 kg/Sq.mm as per existing model complete all as specified and directed. | 2 | Each | 1,500 ₹3,000 | 1,100 ₹2,200 | 22,222 ₹44,444 | 2,000 ₹4,000 | 800 ₹1,600 Lowest | 1,000 ₹2,000 | 2,000 ₹4,000 | 1,900 ₹3,800 | 1,000 ₹2,000 | 2,500 ₹5,000 |
| 10.00 | Supply only in replacement of copper cable multi stranded PVC sheathed size 25 sqmm single coreas per existing model complete all as specified and directed. | 15 | RM | 600 ₹9,000 | 500 ₹7,500 | 750 ₹11,250 | 250 ₹3,750 Lowest | 450 ₹6,750 | 500 ₹7,500 | 300 ₹4,500 | 255 ₹3,825 | 500 ₹7,500 | 800 ₹12,000 |
Tender Value
₹47.4 L
EMD Value
₹95,000
Closing Date
31 Jul 2026, 6:00 pmClosed
Col Amit Bhardwaj
HQ CWE Jammu PIN-180003
SPL REPAIR TO EXISTING DG SETS OF 625 KVA AND 500 KVA AND ALLIED SERVICES AT MH OF MIL STN JAMMU UNDER GE SATWARI
2026_MES_777813_1
CWE/T-62/2026-27
Open Tender
Electrical and Maintenance Works
Works
180 days
GE Satwari
As per tender documents
9 documents required · 9 mandatory
₹500
GE Satwari
₹95,000
Yes
18 Sept 2026
10 Jul 2026
3 Aug 2026
10 Jul 2026
31 Jul 2026
24 Jul 2026
10 Jul 2026 - 14 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling and Inspection complete dismantling of DG set capacities 500 KVA / 625 KVA, inspection of blocks, crankshaft, camshaft, liners, pistons, connecting rods, check cylinder head, valve seats, rocker arms, turbocharger, radiator & pump inspection, alternator etc carrying out to authorised workshop for repair/maintenance of the engine complete for smooth functioning all as per manufacturer's instructions and as directed.
NOTES:- (i) Repair and Maintanance of DG set alongwith connected Alternator and Panel Board including Engine shall be carried out and rectifying the defects by replacing the following unserviceable spare parts as directed by the Engineer-in-Charge.
(ii) Spare parts required for replacement shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be inluded in the rate quoted for this item.
(iii) Cost of all consumables required shall be deemed to be included in the rate quoted for this item. | 2 | Each Job | - | - |
| - | Supply only in replacement of battery terminal for 12 volt as per existing model complete all as specified and directed. | 8 | Each | - | - |
| - | Supply only in replacement of battery cable for 12 volt 180 AH as per existing model complete all as specified and directed | 4 | Each | - | - |
| - | Supply only of battery terminal 10 ml gel complete all as specified and directed. | 4 | Each Pkt | - | - |
| - | Supply only in replacement of Benjo bolts of suitable size as per existing model complete all as specified and directed. | 24 | Each | - | - |
| - | Supply only in replacement of fuel pipe filter as per existing model complete all as specified and directed. | 4 | Each | - | - |
| - | Supply only in replacement of Automatic Voltage Regulator (AVR) suitable for DG set of capacity 500 KVA as per existing model complete all as specified and directed. | 1 | Each | - | - |
| - | Supply only in replacement of Automatic Voltage Regulator (AVR) suitable for DG set of capacity 625 KVA as per existing model complete all as specified and directed. | 1 | Each | - | - |
| - | Supply only in replacement of Low Oil pressure Switch 12V 1.7 kg/Sq.mm as per existing model complete all as specified and directed. | 2 | Each | - | - |
| - | Supply only in replacement of copper cable multi stranded PVC sheathed size 25 sqmm single coreas per existing model complete all as specified and directed. | 15 | RM | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
TENDER62merged.pdf
Tender Documents • 1.29 MB
BOQ_871123.xls
BOQ • 1.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .