Tender Value
₹17.9 L
Closing Date
15 Apr 2021, 12:00 pmClosed
Atul Bhardwaj
Ex. Engineer (E)/WZ
Setting up one Swachhta kendra Plastic Waste Management facilities by united Nations Development Program UNDP india through their implementation partener Hindustan Coco cola Beverages pvt Limited in area under the juridivtion of SDMC SH PO EI Fans
2021_SDMC_75296_1
EE/Elect/WestZone/2021-22/01
Open Tender
Electrical Works
Item Rate
180 days
NAJAFGARH ZONE.
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Commissioner SDMC
Exempted
19 Apr 2021
8 Apr 2021
16 Apr 2021
8 Apr 2021
15 Apr 2021
8 Apr 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
.Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed mediumclass PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
2X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A switch
3 pin 5/6 amp socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required..
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450 mm Sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator),12Way Double door
8 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required single pole
Double Pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 Amp
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required..
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.250 A,36KA,FPMCCB
400 A,50KA,FPMCCB
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
90 mm dia (OD-90 mm & ID-76 mm nominal)
Supply of 18 (450)sweep 1400 rpm exhaust fan heavy duty complete with shutters blades etc as reqd
Supply of 12'' ( 300 mm )sweep 1400 rpm exhaust fan heavy duty complete with shutter,blade etc as required.
Supply of XLPE insulated and PVC Sheathed Al conductor armoured cables 1.1 KV grade conforming to IS7098 as required. 4x25sqmm
3.5x95sqmm
Supply of XLPE insulated and PVC Sheathed Al conductor Un-armoured cables 1.1 KV grade conforming to IS7098 as required. 2x10 sqmm
Supply, Installation, Testing and Commissioning of1200 mm sweep, BEE 5 star rated,ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as required. .
S/F installation of cubical panel board 16 SWG sheet M.S depth 30 cm to 60 cm with A1. bus bar andd interconnection suitable for switch gears i/c and making foundation etc as required
S.I.T.C LED tube type luminaire 20 watt rating complete with extruted alluminium batten prewired with high efficiency LED with the following specifications.(A) Total system wattage 20 watt+/- 5% ,(B) Luminous efficiency >= 95 Lumens/watt, © Power factor >= 0.95
S.I.T.C of 150 watt LED flood luminiare fitted with lens , made of pressure die cast alluminium housing & toughened glass cover complete with the following specification as required .(A) Total system wattage 150 watt+/- 5% ,(B) Luminous efficiency >= 100 Lumens/watt, © Power factor >= 0.95,(d) Protection class -IP-66
P/F of hot press sheet moulded compounded (SMC ) fire retardant ( Temp. resistance up to 200C) Ip -55 weather proof pole box of inner dimension 200X160X98mm complete with suitable arrangement for fixing of 2 nos. of 6 to 32 Amp. Single pole MCB & 63 a double pole isolator ( MCB and isolator excluded) with nutral link duly shorting on DIN channel with 2 nos of clamp wit ss back plate of suitable size with Danger Monograme & SDMC property printed on the cover ETC as required.
`Supply installation testing and Commissiong of Single monoblock pump set complete with all accessoires workable on 240/415 volt, 50 HZ AC supply .1 HP (0.75 KW ) Single Phase pump set head from 12 to 30 mt, suction & deilivery 25x25mm
Providing and laying of HDPE PIPE 40mm outer dia with PN rating 4 by hand/manual method conforming toIS 4984.
Fabrication, supply and erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor- 4 nos. and shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length, 6 Amp. SMeterCB C characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS. 5.0 mtr height, 3 mm thick, bottom dia of 130mm and top dia of 70mm base plate of size 225 x 225 x 12 mm thick
51 Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L) x450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1400 mm (approx) -6 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 16 mm dia,600 mm long, J type i/c 2 nos. template anchor plates of size 225mmx225mmx3mm and providing DCW HDPE for cable entry and exit as required for 3 m and 5 mtr pole.
S.I.T.C of 60 watt LED street light luminiare fitted with lens , made of pressure die cast alluminium housing & toughened glass cover complete with the following specification as required .(A) Total system wattage 60 watt+/- 5% ,(B) Luminous efficiency >= 100 Lumens/watt, © Power factor >= 0.95,(d) Protection class -IP-66
Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 32 mm dia galvanised pipe with tightening bolts complete as required.
DEV ENGINEERS
M/s HI TECH ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .