| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-Finance C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L1 | Accepted-Finance Being Lowest Bidder | |
| 2 | L2₹31.4 L+₹98,544.60 (3.24%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹38.8 L+₹8.3 L (27.4%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | Manisha Enterprises L3 | SWASTIK INFRA L2 | SHRI HARI CONSTRUCTION L1 |
|---|---|---|---|---|---|---|
| 1.00 | Disconnecting from mains and taking down for cleaning of Water Cooler of Capacity 40/80, 60/120, Litres including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner blower ,or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed .
Note :- 1. Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items and Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above. | 10 | Each job | 500 ₹5,000 | 650 ₹6,500 | 230 ₹2,300 Lowest |
| 2.00 | S & F in replacement over load protector relay suitable for 40 to 150 litrs Litres capacity water coolers complete all as specified and as directed . | 1 | Each | 150 ₹150 | 350 ₹350 | 120 ₹120 Lowest |
| 3.00 | S & F in replacement Starting relay suitable for 40/80, 60/120, 150/150 Litre complete all as specified and as directed . | 1 | Each | 180 ₹180 | 350 ₹350 | 150 ₹150 Lowest |
| 4.00 | S & F in replacement thermostat suitable for 40/80/120/150 Litre capacity water coolers. | 2 | Each | 300 ₹600 | 415 ₹830 | 250 ₹500 Lowest |
| 5.00 | Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/32hp to 1/16 HP as per site requirment from water cooler cap.40/80,60/120, 150/150 Litre and supply and fixing with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as specified & as directed. | 2 | Each Job | 1,000 ₹2,000 Lowest | 3,250 ₹6,500 | 1,000 ₹2,000 Lowest |
| 6.00 | S & F in replacement Starting Capacitor 25 MFD complete all as specified and as directed . | 2 | Each | 120 ₹240 Lowest | 300 ₹600 | 165 ₹330 |
| 7.00 | S & F in replacement running Capacitor 10 MFD complete all as specified and as directed . | 3 | Each | 80 ₹240 Lowest | 260 ₹780 | 120 ₹360 |
| 8.00 | S & F in replacement waste water tray complete suitable for 40/80, 60/120, 150/150 Litre capacity water coolers complete all as specified and as directed .
( Suitable for Voltas/Sidwal/Blue Star make water coolers). | 1 | Each job | 1,000 ₹1,000 | 850 ₹850 | 550 ₹550 Lowest |
| 9.00 | S & F in replacement chromium plated push taps suitable for 40/80/120/150 Litre capacity water coolers all as directed. | 10 | Each | 380 ₹3,800 | 560 ₹5,600 | 300 ₹3,000 Lowest |
| 10.00 | M&L for Float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 140 grams including taking down existing complete all as specified and directed. | 2 | Each | 190 ₹380 Lowest | 560 ₹1,120 | 230 ₹460 |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
10 Aug 2026, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR /MAINT OF SPLIT/ WINDOW AC, WATER COOLER, DESERT COOLER, DEEP FREEZERS AND REFRIGERATORS AND REPAIR/ MAINT OF LOW VOLTAGE STABILIZERS AND ALLIED WORKS AT AFS JAISALMER UNDER GE (AF) JAISALMER
2026_MES_777985_1
8453/GE/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Jaisalmer
₹62,000
Yes
14 Aug 2026
11 Jul 2026
12 Aug 2026
11 Jul 2026
10 Aug 2026
25 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnecting from mains and taking down for cleaning of Water Cooler of Capacity 40/80, 60/120, Litres including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner blower ,or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed .
Note :- 1. Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items and Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above. | 10 | Each job | - | - |
| 2 | S & F in replacement over load protector relay suitable for 40 to 150 litrs Litres capacity water coolers complete all as specified and as directed . | 1 | Each | - | - |
| 3 | S & F in replacement Starting relay suitable for 40/80, 60/120, 150/150 Litre complete all as specified and as directed . | 1 | Each | - | - |
| 4 | S & F in replacement thermostat suitable for 40/80/120/150 Litre capacity water coolers. | 2 | Each | - | - |
| 5 | Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/32hp to 1/16 HP as per site requirment from water cooler cap.40/80,60/120, 150/150 Litre and supply and fixing with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as specified & as directed. | 2 | Each Job | - | - |
| 6 | S & F in replacement Starting Capacitor 25 MFD complete all as specified and as directed . | 2 | Each | - | - |
| 7 | S & F in replacement running Capacitor 10 MFD complete all as specified and as directed . | 3 | Each | - | - |
| 8 | S & F in replacement waste water tray complete suitable for 40/80, 60/120, 150/150 Litre capacity water coolers complete all as specified and as directed .
( Suitable for Voltas/Sidwal/Blue Star make water coolers). | 1 | Each job | - | - |
| 9 | S & F in replacement chromium plated push taps suitable for 40/80/120/150 Litre capacity water coolers all as directed. | 10 | Each | - | - |
| 10 | M&L for Float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 140 grams including taking down existing complete all as specified and directed. | 2 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
8453Tenderdouc.pdf
Tender Documents • 1.44 MB
BOQ_871326.xls
BOQ • 0.37 MB
8453Letter.pdf
PDF • 0.26 MB
8453Letter.pdf
PDF • 0.26 MB
8453lettertender.pdf
PDF • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .