| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹17.4 L+₹35,522.50 (2.08%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹22.0 L+₹4.9 L (28.9%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹22.3 L+₹5.3 L (31.1%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹22.6 L+₹5.5 L (32.5%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
29 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAMS
GE NAMS
CERTAIN REPAIR TO TARAPORE AND ROYCHOWDHARY ENCLAVE UNDER AGE B/R-II AT NAMS
2022_MES_555568_1
GE NAMS-46/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE NAMS
CLASS E CATEGORY a(i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹50,000
Yes
17 Dec 2022
1 Oct 2022
1 Nov 2022
1 Oct 2022
29 Oct 2022
15 Oct 2022
Amount
S&F for 15 mm bore GI tube medium grade fixed to wall or under floor incl taking up or down old tube complete incl cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 complete all as specified and directed.
S& F for 20 mm bore G.I tubing in new or old location (wall/Roof) with all fittings incl taking up or down old tube complete all as specified and directed.
Fixing only in repair steel tubing and connection 20 mm dia bore to wall and laid in floors incl taking up or down old tube and cleaning for refixing complete all as specified and directed.
Supply and fxing in replacement of rotational moulded polythene water storage tank, white coloured, tripple layer cylindrical vertical with closed top 500 litre capacity hoisted and fixed in position, including inlet and outlet pipe connections, 20mm dia and 15 mm dia GI pipes medium grade respectively, 20mm GI pipe medium grade over flow pipe 15 cm long wash out with plug and brass ball valve 20mm, high pressure with polyethelyne float and fly nuts complete all as specified and directed.
Description all as per Item No 4.00 above but 1000 litres water storage tanks.
M&L for brickwork with sub class 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete incl demolition of brickwork /stone built in cement mortar etc. disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC, complete all as specified and directed.
Descriptio all as per Item No 6.00 above but except bricks.
M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete incl demolition of brickwork /stone built in cement mortar etc., disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC. complete all as specified and directed.
M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed.
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish even and fair (w/o using extra cement) incl WPC as per user manual complete all as specified and directed. (WPC shall be measuared seperatly and @ 200ML for 50kg cement bag or as per manufacturer's instructions).
M&L, Rendering 15mm thick in CM 1:6 on of brick work or concrete surface finishing the surface even and smooth (w/o using extra cement) incl taking down old plaster on brick or stone wall, scrubing down with water etc & disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC., complete all as specified and directed.
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finishing the surface even and fair (w/o using extra cement) incl WPC as per user manual complete incl taking down old plaster on brick or stone walls, scrubing down with water etc & disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC., complete all as specified and directed. Note : (WPC shall be measuared seperatly and @ 200ML for 50kg cement bags or as per manufacturer's instructions).
Supply only liquid WPC complete all as specified.
M&L, Rendering 10mm thick in CM 1:3 over concrete surface as on ceiling finishing the surface even and smooth w/o using extra cement incl taking down old plaster on ceiling ,scrubing down with water etc & disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC., complete all as specified and directed.
M & L for three coat of white wash incl preparation of new plastered surface of ceiling complete all as specified and directed.
M&L for applying one coat of oil bound distemper on old surface including preparation of old surfaces of walls etc, incl necessary minor repair of wall by applying wall care putty complete all as spd and directed.
M&L for applying one coat of cement base paints on walls etc,incl preparation of old surface and complete removal existing treatment on wall complete all as specified and directed.
M&L for two coat of Acrylic smooth exterior emulsion paint on walls, pillars cornices etc surfaces by spray machine over one coat of primer incl preparation of new plastered surface complete all as specified and directed. Note : Colour and make as approved by Engr-in-Charge
M&L for applying two coats of oil bound distemper by spray machine incl preparation of old surface by complete removal existing treatement on walls through electrical operated grinder etc, incl necessary minor repair of wall by applying wall care putty complete all as specified and directed.
M&L for applying two coats of cement base paints on walls etc, incl preparation of old surface by complete removal of existing treatement on wall complete all as specified and directed.
M&L for one coat of Acrylic smooth exterior emulsion paint by spray machine on old plastered/ unplastered surfaces of walls, pillars, cornices etc. incl preparation of old surfaces through electrical operated grinder complete incl edges over to obtain smooth finish using sand paper, over one coat of primer complete all as specified and directed.
M&L for one layer of compound of altek/birla putty 3mm thick on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed.
M & L for repair to RCC Chajjas, roof projection edges ,hanging part of chajjas, edges of chajjas, RCC parapets, under the roof / floor slabs with PCC 1:2:4 (using 12.5mm crushed graded agg) incl neccasary renforcement 8mm to 12mm TMT bars , form work, MS wire mesh for bounding the concrete on ground required and plaster work in CM 1:3 & periodical services to match with the existing surfaces finishing at any height of buildings etc completed all as specified and directed by Engr-in-Charge.
S&F 3mm thick, sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exc 0.5 Sqm in each pane fixed with oil putty or beads and incl hacking out unserviceable glass & disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC, complete all as specified and directed.
S&F in repair for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples / beading complete all as specified and directed..
M & L for PCC 1:4:8 type D-2 (using 20 mm agg.) in sub base of flooring incl demolition complete all as specified and directed.
M&L for non skid ceramic any coloured/printed tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,over15 mm thick rendering as screed bed in cement mortar (1:4) in floors, incl dismantling / demolition and disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC., complete all as specified and directed.
Descriptio all as per item 27.00 above but area of each tile exe 0.11 sqm but n.exe 0.18 sqm, in floors & dado etc complete all as specified and directed.
M&L for glazed ceramic coloured/printed/ dark tiles size 300x200mm x7mm thick on vertical surface in skirting /dado ,set and jointed in neat cement slurry and pointed with white cement with pigment to match the colour of tiles, 10 mm thick rendering on fair faces of concrete surface of verticle in CM (1:3) finished even and smooth without using extra cement complete, shade & design as approved by EIC/GE, incl dismantling and rubbish off the premises etc all as specified and directed.
Descriptio all as per item 29.00 above but area tiles of size exc 0.09sqm but n.exc 0.18sqm on vertical surface in skirting /dado etc.
M&L for green marble 15-17 mm thick over cement screed bed laid on 15 mm thick CM 1:6 and jointed with grey cement slurry mixed with pigment ot match the shade of the slab / staircase / steps,riser incl rubbing and polishing incl moulding rounding to edge of marble & dismantling of old marble incl disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC., complete all as specified and directed.
M&L for Granite 18-20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding ,rounding of edging and dismantling of old granite incl disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC., complete all as specified and directed.
S&F in repair 18/19 mm prelaminated particle board, prelaminated both side with decorative choice lamination & other side balancing white lamination, as in cupboard shutters fixed with screws to timber/steel frame work (incl 30mm Continuous (piano) hinges, mild steel, 2 Nos 100mm aluiminium handles, 1 Nos 100mm hasp & staples for each cupboard) complete all as specified and directed.
M&L 50 mm thick cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in plinth protection and laid in bays complete and finished the even & fair and providings joints through out the thickness of plinth protection filed with mastic filling comprising one part of 01 bitumen 85/25 grade and three part of sand by weight incl dismantling / demolition and disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC., complete all as specified and directed.all as specified and directed.
M & L for 100 mm thick PCC 1:2:4 Type B-1 (using 20mm graded stone aggregate) as in flooring incl finishing the cement concrete surface even and smooth with using extra cement , rubbish off the premises and incl demolition complete all as Specified & directed .
M & L in repair framed work as in doors of angle or other section complete drilled for fixing sheeting with all fitting and fixture complete (Fe 410-W (Gde-E-250) quality A) all as specified and directed.
S&F for 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides incl taking down shutter and fixing clips of sheet, complete all as specified and directed.
S&F for 2nd class hard wood glazed and skelton door shutters 35mm thick, open rebated and prepared to received glass/gauge etc (without sash bars) edges of framing plain, chamfered or rounded and mitred , beads for securing glass etc the size of member of shutter as specified in SSR Part-I clause 8.24(b) and fitted to chowkhat complete all as specfied and directed.
S & F for solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube incl taking down old frame any type complete all as specified and directed.
S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitabale PVC sheet beading, and jointed together with solvant cement, fixing in the frame at side as per specification and drawing incl taking down old shutter complete all as specified and directed
S & F for butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, 100mm, type C-21 complete all as specified and directed.
S&F for aluminum handles cast type anodized 150 mm long (ISI Marked) complete all as specified and directed.
S&F for 150mm aluminium anodised barrel tower bolts of extruded section and fixed ISI marked complete all as specified and directed.
M & L for one coat of synthetic enamel paint on steel surface incl preparation of old steel surface width or girth exc 10cm all as specified and directed.
M&L for one coat of synthetic enamel paint on wooden surfaces of any description over 10cm width or girth including preparation of old surfaces complete all as specified and directed.
M&L for box type steel window 1.25 mm thick made of ERW tube P-Section of size 60 x 25 mm double rebated outer frame comprise of glazed skeleton shutter(two gauged shutters and two glazed shutter) of ERW tube P-Section size 50 x 20 mm and 1mm thick one/two Nos openable leaf consisting of two Nos sash bar of T-Section 20x3mm welded to frame with one No Vertical mullion of ERW box type T-Section of size 60 x 25 mm and 1.25 mm thick and FI 2 mm thick welded / screwed to frame for fixing of glass including fittings and fixture like Handle, Tower Bolt, stopper, cleat, pintal hinges, hold fast etc. (i) Hold Fast, 150mm long of 120mm x 3 mm made to shape -04 Nos per window. (ii) Handle of Z sec 20mm x 25mm, 100 mm long -1 No per leaf (iii) MS Tower bolt 150mm long - 2 No per leaf (iv) Z Sec 20mm x 25 mm, 100 mm long stopper - 1 No per leaf (v) Cleat 55 mm long of hollow square 15mm x 20mm x.63mm welded to hinge -1 No per leaf. (vi) MS Pintal hinges of size 75mm x 12mm - 2 Nos per leaf .
(vii) 10 mm square guard bar, 10 cm centre to centre. (viii) 25x4 mm flat iron all around for joint of both frame. (ix) stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples & 3mm thick, sheet glass ordinary quality and glazing with oil putty .(x) Two coat of synthetic enamel paint to MS window and guard bar. Note : Incl taking down old steel / wooden window and making good dismantled portion with PCC 1:2:4 type B0 incl hold fast PCC (four No’s for Each window) & around required plaster in CM 1:4 and match with existing finishing complete all as specified and directed by Engineer-in-charge.
M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mm incl rendering 10mm thick in CM 1:3 with WPC in sunken slab/wall complete all as specified and directed.
M&L, cement concrete 1:7:12 (40 mm graded aggregate ) in lean concrete as in sunken floor including demolition and disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC., complete all as specified and directed.
S&F for Pre- painted galvaume aluminum zinc coating GI based manglore/ trapezoidal/semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding, fixed with self tapping screws as incl dismantling of plain or corrugated steel sheeting in roof covering all as specified and directed by EIC. Note- Design/Pattern/colour of roofing sheet sheet to decided and approved by EIC/GE.
M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling and disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC., complete all as specified and directed.
M&L for broken bricks hard core gauge n.exc 63mm deposited, spred and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces.
S&F for 4mm thick acrylic sheet board of High quality with Media printing of 3m of best quality (size/frame of board , design of bd , type of print on sheet , size of studd , samples of letter, pictures, writing will be provided by accepting officer or Engr-in-Charge) and fixed at any height from GL to 29 Mtr height incl stainless steel studds (min 4 studs at each board / sheet ) complete all as specified and directed incl dismantling of existing damaged sheets. Note : Minimum weight of Acrylic Sheet not less than 4.70kg per sqm (Acrylic sheet make A Cast / Astari / Marka Cipta and stainless steel of grade A-ISI 304(1818).
M&L for PCC 1:3:6 type C-0 as in roof Padding (using 12.5 mm graded aggregate ) complete all as specified and directed.
M & L for applying two coat of undiluted thick coat of acrylic reinforcement liquid applied elastermeric water proofing membrane with UV resistance properties and solar reflective properties over one coat of primer (1:3, Dilution:water) Note: Gap between each coat will be 6 hrs) Applicater Company approved complete all as specified and directed. Note : Item shall be executed by approved company applicator.
M&L, for 40 mm thick brick tiles laid over 15mm thick screed bed (1:3) and joints grouted flush incl pointing in cement mortar (1:3) mixed with 5% of crude oil by weight of cement incl dismantling and disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by the EIC., complete all as specified and directed.
Description all as per item 55.00 above but except tiles
M & L pointing to brick tiles in CM 1:3 laid flat in roofing incl racking out joints complete all as specified and directed.
S & F in repair for vitreous china squating pan of (Orissa Pattern) size 580 x 440 mm white with 'P' or 'S' trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe) fixed incl cement concrete bedding as required set complete all as specified and directed.
S & F in repair for vitreous china wash down water closet pan (pedestal pattern) coloured including 'P' or 'S' trap with flush pipe of chromium plated brass 32 mm dia for low level flushing cistern incl plastic seat cover white closed pattern with float bottom and cover and jet connection and mild steel chrominum plate or aluminized hanging device fixed in repairs complete all as specified and directed.
S & F in repair for vitreous china wash hand basin white flat back size 550 x 400 mm with leg incl CP waste coupling, waste pipe & plug and porcelain stopper brackets and cutting for and pinning in ends of brackets or erecting stand fixed complete all as specified and directed.
S & F in repair for vitreous china wash hand basin white angle back/corner size 400 x 400 mm incl CP waste coupling waste pipe and plug and porcelain stopper brackets and cutting for and pinning in ends of brackets or erecting stand fixed complete all as specified and directed.
S&F in repair 10 ltr capacity low level flushing cistern with PVC bend and PVC flush down pipe etc complete all as specified and directed.
S & F in repair Bib taps, cast copper alloy, chromium plated, fancy type, long body with crutch or butterfly handle, screwed down, screwed for iron pipe of 15mm bore and fixed complete with all fittings all as specified and directed.
S & F in repair Angle cock CP fancy type 15 mm bore screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for Unions complete all as specified and directed.
S & F in repair Stop cock concealed long shank chromium plated fancy type 15 mm bore screwed down high pressure with crutch or butter fly handle complete all as specified and directed.
S& F for in repair swan neck pillar cock chromium plated fancy type screw with iron pipe incl all fittings complete all as specified and directed .
S&F in repair hole washbasin mixer wround spout with 375 mm long braided hoses complete all as spd and directed.
S & F in repair wall mixer 15 mm bore (fancy type) cast copper alloy with capstan head, CP screwed down high pressure with long screwed both ends for iron pipe as per union complete all as specified and directed.
S&F for PVC connections 45cm long superior quality with PTMT nut on both side complete all as specified and directed.
S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed.
Descriptio all as per ser item No. 71.00 above but laid in trench or in floor complete all as specified and directed.
S&F for PVC (SWR) gully trap 110 mm, setting and jointing with solvent cement complete all as specified and directed. .
S&F for 110mm bore PVC bends/junction any radius complete all as specified and directed.
S&F for 100mm bore Cast iron soil, waste and vent pipes, sand cast in any length with or without ears, with cement joints, fixed to walls etc incl taking down old pipe complete all as specifed and dirtected.
S&F for 100mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specifed and dirtected.
S & F in repair gunmetal, globe or gate valve 20mm bore with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed.
Descriptio all as per Item No 77.00 above but 25mm bore
S&F in repair stainless steel plate rack overall size 900 x 750 x 250mm, weight not less than 7.00 kgs for each, made out of 0.63mm thick stainless steel sheet as per standard pattern fixing to walls with screwed complete all as specified.
S&F in repair sinks made of stainless steel 1 mm thick kitchen or laboratory with drainage board of size 915 x 460 mm with plugs, washers and wastes; incl bedding in cement mortar on to dwarf wall or including fixing cantilever brackets of angle iron 50x50x6mm and connecting union to pipe, overall size 915mmx460mm bowl size 410mmx330mmx160mm fixed complete all as specified.
M & L for two coat of synthetic enamel paint over a coat of red oxide primer on steel surface incl preparation of new steel surface width or girth exc 10cm all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of pink primer on wooden surfaces of any description over 10cm width or girth including preparation of new surfaces complete all as specified and directed.
S&F in repair for fancy type 125 mm size chromium plated shower roses with or without swivel joints ,any size including fixing to steel pipe or union complete all as specified and directed.
Chander Mohan Arora Contractor
M/s MAHAJAN CONSTRUCTION CO.
Mahajan Builder
Jaspal Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .