Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 447 A DHALITITHA BASIRHAT NORTH 24 PARGANAS PIN 743412 WEST BENGAL | BASIRHAT | NORTH 24 PARGANAS | WEST BENGAL | 743412 | Accepted-Technical Qualified in technical evaluation |
| 2 | Rejected-Technical 31 1 6 SEBADAL ROAD UDAYPUR NIMTA KOLKATA 49 | 24 PARAGANAS NORTH | WEST BENGAL | 700049 | Rejected-Technical Disqualified in technical evaluation |
| 3 | Rejected-Technical 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | Rejected-Technical Disqualified in technical evaluation |
| 4 | Rejected-Technical | Rejected-Technical Disqualified in technical evaluation |
Tender Value
Refer Docs
EMD Value
₹11,200
Closing Date
18 Dec 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Exe. Engr.-I, Kol. South Health El. Divn., PWDte
75 D H Road Kidderpore Kol_23
Upkeepment and Mtc. Round the Clock yearly basis for FD System and allied accessories etc. at all buildings with the campus of IPGMER_SSKM hosp. and its Annexes, Kol-Urgent require for repl. of Plastic body tube light and wall bracket fan fittings
2025_WBPWD_956259_1
WBPWD/EE-I/KSHED/Q71/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,200
O/o Exe. Engr., Kol. South Health El. Divn., PWDte
2 Jan 2026
21 Nov 2025
22 Dec 2025
21 Nov 2025
18 Dec 2025
29 Nov 2025
28 Nov 2025
Supply & Fixing 240 V., T.L. Fittings complete with all accessories and necy. 2 Nos. 20 mm EI Conduit length as per Site Condition incl.connection by 2 x1.5 mm² PVC insulated Cu. Wire & painting as follows:-
Supply and Delivery of 4 feet Industrial box type single LED tube fitting incl. Supply & Delivery of 1 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Supply and Delivery of 4 feet Industrial box type twin LED tube fitting incl. Supply & Delivery of 2 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 105 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Supply & Fixing of 230V, 50Hz, 450 mm sweep heavy duty full metal body wall bracket fan having wattage ≤ 90 Watt, RPM ≤ 1325, Air Displacement (In CFM) ≥ 3550 complete with all accessories incl. S&F of HW Base with all necessary items as per direction by EIC. (Make - Orient/Crompton/ EPC/Cinni) [BEE star rated]
Supply & Fixing of 230V, 1-Ph, 450 mm Sweep, 1-Ph, 4 Blade, RPM ≤ 1420 , Wattage ≤ 100 Watt, Air Displacement (In CFM) ≥ 5000 Wall Mounting/ Pedestal Air Circulators with all accessories. (Make- Crompton / Usha / Orient/ Polar/EPC) [BEE star rated]
Supply & Fixing of 220V, Single Phase, 50 Hz, 300 mm (12"), 4 Blade, RPM ≤ 950 , Wattage ≤ 45 Watt, Sound level ≤ 46 dB, Air Displacement (In CFM) ≥ 750 A.C heavy duty exhaust fan of following sizes having complete metal body. (Make- EPC/ USHA/Orient CROMTON) [BEE star rated] incl.cutting hole on wall and S&F GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) of mending good the damages to original finish.
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Havells/Gloster/Polycab/KEI) in 20mm size PVC rigid conduit 'FRLS' (Precision/Polycab make, MMS/HMS type), with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Havells/Gloster/Polycab/KEI) for ECC, to light/fan/call bell points with Piano Key type switch (Make:Anchor) fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish.
(Average run-8 Mtrs)
Fixing only SPN MCB DB(4 to16 way) on flat iron frame on wall
Supply & Fixing fan down rod (14 SWG- white MS pipe zinc plated) having 19 mm OD 1.8 + / - 0.05 mm thick complete with cutting, making holes for fixing the fan incl. necessary con nection wire (2Xl.5sqmm cu wire) as per direction of EIC (Rate in per feet)
Dismantling the existing damaged Plastic body tube light & wall bracket fan fittings & fixture as required very carefully & carrying the same to safe place as per direction of EIC.
Less: Cost for unserviceable dismantled materials - (-) Rs. 1500/-
Make and model to be approved by the EIC
Defect Liabibility Period 1 (One) year
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
cancelled_1.pdf
pdf • 0.73 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.26 MB
TenderForm.pdf
Tender Documents • 0.69 MB
BOQ_2295673.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .