Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance F 402 AMBIKA APARTMENT PLOT A 9 SECTOR 20 NERUL W NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | Admitted-Finance |
| 5 | Admitted-Finance SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | Admitted-Finance |
Tender Value
₹48.8 L
EMD Value
₹97,671
Closing Date
13 Nov 2024, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD, MANKHURD - 400088
PROVISION OF DEFICIENT BAGGAGE ROOM AT NOFRA, MANKHURD AND REPLACEMENT OF 60 KVA UPS AT TS MAHUL UNDER GE (NW) MANKHURD
2024_MES_679921_1
8389/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) MANKHURD
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹97,671
23 Nov 2024
17 Oct 2024
15 Nov 2024
17 Oct 2024
13 Nov 2024
31 Oct 2024
Amount
M & L Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out In Hard/dense soil.completed all as specified
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in soft loose soil.
Excavating in trenches, by mechanical means(hydraulic excavator) n exc 1.5 m wide and n exc 1.5 m in depth; for Plinth Beam & Dwarf Wall, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth for Dwarf Wall and getting out in Hard/dense soil.
Excavating in trenches, n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard/dense soil.
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
M & L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
M & L Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)
M & L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall
M & L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
M & L Cement concrete in foundations, filling and mass concrete 1:4:8 using 40 mm graded aggregate (For Foundation)
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Hard/dense soil.
Removing excavated material in Hard/dense Soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
M & L RCC- M-30 (Design Mix) using 20mm graded aggregate For Footing and plinth beams
M & L RCC- M30 (Design Mix) using 20mm graded aggregate for Column complete all as specified and directed
M & L RCC- M30 (Design Mix) using 20mm graded aggregate for beams and lintels complete all as specified and directed
M & L RCC- M30 (Design Mix) using 20mm graded aggregate for RCC Slab
M & L RCC- M30 (Design Mix) using 20mm graded aggregate for RCC Chajja.
S & F TMT bars 10mm dia & over of Grade Fe 500 incl cutting, bending, binding & placing in position with binding wirefor footings Slab beams roof slab etc complete al as specified and directed
Ditto but 5 to 10mm dia in stirrups, spacers & binders.
M & L Form work for rough finished surfaces of concrete measured flat for For Footing
M & L Form work for rough finished surfaces of concrete measured flat for Column,
M & L use & waste Form work for rough finished surfaces of concrete measured flat for Plinth Beam
M & L use & waste Form work for rough finished surfaces of concrete measured flat for RCC beams sides and soffits
M & L use & waste Form work for rough finished surfaces of concrete measured flat for RCC Slab
M & L use & waste Form work for rough finished surfaces of concrete measured flat for RCC chajjas
M & L Pre-cast cement concrete block masonry with solid blocks Type C1 1:3:6, exc. 10 cm in width and setting in Cement mortar (1:6) mortar, complete.
S& F factory made WPC solid door frames of size 65x100mm complete all as specified .and directed
S& F factory made single extruded WPC solid door shutters decorative type flush door of size 35mm complete all as specified .and directed
S & F Rolled Mild Steel Framed work as in doors or Gates of angle or other section confirming to Fe 410 - S, with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering and hanging and fixing complete.
S&F extruded aluminum alloy handles (150mm ) fabricated type anodised complete all as specified Make :- Shalimar / jyoti/ Classic/ Ashoka
S&F hinges (125 mm) cold rolled mild steel medium weight complete all as specified
S&F aluminum anodised barrel tower bolts (150 mm ) of extruded section complete all as specified
S&F 300 mm Aluminium alloy , anodised , sliding door bolt with hasp, staple (bolt type ) and fixing clips of sheet , cast , exctruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified
S & F For powder coated aluminium sections frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
M&L for Ready mix plaster 10 mm thick on faces of bricks or concrete surface including including preparation of wall surfaces etc complete all as specified and directed.
M&L for rendering 5 mm thick in ready mix plaster on ceiling surface and finishing the surfaces even and smooth without using extra cement including scrapping down and preparation of ceiling surfaces to receive plaster, scaffolding as reqd etc, complete all as specified and directed.
M&L for Ready mix polimer modified cement based plaster 12 mm thick on new bricks or concrete surface including preparation of wall surfaces etc complete all as specified and directed.
Material & Labour for applying two Coats Of Oil Bound Distemper Over One Coat Of Primer on Internal Wall
Material & Labour for applying Two coat of oil bound distemper on ceiling
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additivesM @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M & L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M & L 75mm Thick Cement concrete ( 1:4:8 ) type D-2 (40mm graded aggregate)
M & L for Machine cut kota stone 18-20mm thick over cementscreed base, laid and mixedwith pigment to match the shade of the slab to full thickness of for flooring over cement screed bed 10mm thick in CM 1:4 and jointed with grey cement paste and slurry including rubbing and polishing complete all as specified and directed.
M & L for Machine cut kota stone 18-20mm thick over cementscreed base, laid and mixedwith pigment to match the shade of the slab to full thickness of for skirting over cement rendering 10mm thick in CM 1:4 and jointed with grey cement paste and slurry including rubbing and polishing complete all as specified and directed.
M & L for Machine cut cudappah stoneslab 18-20mm thick over cementscreed base, laid and mixedwith pigment to match the shade of the slab window cills and jambs to full thickness of wall fixed in steps over cement rendering 10mm thick in CM 1:4 and jointed with grey cement paste and slurry including rubbing and polishing complete all as specified
M & L 75mm thick Plinth Protection PCC (1:3:6) using 20mm graded aggregate (0.75 m wide).
M & L for 3 mm thk APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications including dismantling / taking out existing water proofing treatmentcomplete all as specified and directed:- (a) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fibre weight not less than 160gm/Sqcm using butane torch by torch application with 10cm side lap and 15cm end lap. (c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii) Non woven polyester weight not less than 160gm /sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650N/Sqcm and transverse not less than 450 N/Sqcm (v) Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi) Elongation : > 20% in both directions. (vii) Impermeability/water tightness at 2 Kgf/cm2. (viii) Water absorption - Not more than 1% on mass within 24 hours. (ix) Cold flexibility - Minimum (-) 20C. (x) Dimentional stability % change = Maximum 1%. (xi) thickness of memberane shall not less than 3 mm. Note bitumen primer will be meaasured seperately
Bitumen primer for use inwaterproofing and damp-proofing treatments
Screed bed or bedding layer of mortar CM(1:3) 10 mm thick
SUPPLY ONLY Water Proofing compound
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge.
Supply only 4mm thick sheet figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 Sqm in each pane etc complete all as specified and directed
Supply only stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
S&F in repairs steel work as in tubular (round/square/ rectangular shape of pipes as approved by Engr-in-Charge) trusses of semi circle shape upt height 6 mtr including post special shaped washers etc complete incl necessary nut bolts wind tiles and gusset plates etc using ERW or induction butt welded tubes conforming to IS 1161-1998 grade Yst-240 complete all as specified
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut 5 cm but n.exc 10 cm long, 16 to 20mm complete all as specified
S & F in repairs Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of colour having tensile stength of 550Mpa as in roof coverings/cladding to wall, fixed with self tapping screws as specified.
M&L preparation of new or previously untreated surface & applying two coat synthetic enamel Painting over a coat of preiming red red oxide zinc chrome complete all as specified
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over New / Old surfaces.
M&L for prepration of old plaster surface of wall complete removal of existing treatment and two coats Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour Incl 2 mm plaster of paris putty complete, as per manufacturer's specification.
M & L Moorum /red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering
M & L for hard core of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 10 cm thick watered and rammed to a true surface complete all as specified.
M & L 75 mm thick Cement concrete type D-2 1:4:8 (40mm graded aggregate) as in Sub-Floors, Sub-Bases, Floors and pavings, etc all as specified and as directed.
M & L Rendering 15 mm thick on fair faces of brick work or concrete surfaces using CM 1:4, finished the surface even and smooth all as specified and as directed.
M & L 100 mm thick Cement concrete type B-2 (1:2:4) (40mm graded aggregate) as in floors and pavings, etc all as specified and as directed.
M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade mixed with greay cement and pigment.
M & L for sand filling under floors or in foundations incl watering and consolidation complete all as specifed and directed.
M & L in repairs for point wiring with PVC insulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including PVC concealed conduit of suitable size of wall/ RCC slab/ ceiling/ colunms/ beams etc with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, including Modular cover plate of suitable size etc with necessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressed steel terminal boxes concealed in wall mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws including taking down old us wiring, fittings etc complete all as specified for one light / fan / bell point controlled by one switch. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit. Make of conduit :- Sudhakar/ Precision/ Diamond, Make of wire :- Finolex/ Havells/ Polycab/ KEI/ Benlo
S & F in repairs modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with finger proof terminal complete all as specified and directed. Make : Havells (Crabtree)/Anchor (Panasonic)/Legrand
S & F in repairs ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, complete all as specified and directed. Make : Anchor (Panasonic)/Legrand/ Havells (Crabtree)
S & F Modular cover plate 6 modules complete all as specified and directed. Make : Havells (Crabtree)/Anchor (Panasonic)/Legrand
Supply & Fix Heavy duty Metallic Body Exhaust fan of sweep 300 mm with frames, blades including provision of mounting anchor fasterners aluminium louvers made of aluminium sheet of 0.5 mm thickness provision of three core 1.5 sqmm copper cable from ceiling rose to fan, making opening of required size in cement mortar brick wall/ RCC for fixing of exhaust fan, making good the disturbed surfaces in CM 1:4 including scafolding if any required to carry out the work in building of height up to 20 meters complete.Make: Orient/Bajaj/Crompton/Almonard
Supply and fix fans ceiliing with BLDC motor complete with blade, canopy, down rod, mounting hook, rubber insulator etc, the colour of fan shall be of Elegant White/Dubai white/ White CF without remote control alongwith batteries and accessories 230 V, 1200 mm sweep, BEE 5 Star rated complete including takingdown old unserviceable fan all as directed by Engr-in-Charge. Make : Havells (Efficiencia Neo (BLDC 26 W) /Orient FALCON 400 / Bajaj (ENERGOS 28)
Supply and fix surface/wall mountain, indoor decorative type LED luminaire extruded aluminium batten in anodized finished with opal diffuser, with IP 20 protection of capacity 18/20W having luminious efficiency not less than 100 lumen/watt, CCT 6500K4 feet long operating on 230V, 50Hz, AC supply including fixing and mountaining on PVC blocks 02 Nos & connecting with 1.5 sqmm, 3 core PVC insulated copper conductor and suitable nuts bolts & washers complete all as specified and directed " Make : Bajaj, Model : BCLAV20W-LEDP, Halonix :- HLB-03-18-CW-AL-SQ-HL2, Jaquar :- LGLZU1X022XC, WIPRO Note : The lowest tenderer shall furnish 3 years warranty certificate from OEM for luminiries including LM79 & LM80 test certificate from NABL certified laboratory.
Supply & Fix MCB DB Double Door SPN 4 way 240 volts including connecting up with existing cable with new lugs. The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider
Supply and fixing SP 5A to 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. Make: L&T/ C&S/ Havells
Supply and fixing SPN 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. Make: L&T/ C&S/ Havells
M&L for sub main wiring with two single core 4.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 4 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. (Make :- PRESFIT/ PRECISION - Casing caping), (Make :- FINOLEX/ KEI/ POLYCAB - PVC Copper wire) Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping of 4.0 sqmm will be measured and paid one unit.
M&L for sub main wiring with two single core 2.5 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through PVC concealed conduit with and including PVC insulated 1.5 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly including taking down old unserviceable submain wiring complete all as specified and as directed Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit. Make of wire : KEI/ BENLO/ Polycab/ Anchor(Panasonic)
S & F LED light fitting 1X10W Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make: Bajaj/ Wipro/Crompton
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.0 sq mm 3.5 core Make : Polycab/ KEI/ Grandley
M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified. Make: Mehtab tiles/ National
S&F 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. Make: C&S/ L&T/ Schnieder
Supply And Fix in repairs MCCB DB TPN 6 Way double door 100 Amps prewired suitable for Triple Pole 63 A MCCB as incomer with the following acessories & connecting of existing cables & providing of acbel glands, a) MCCB TPN 63 A 25 KA 415 Volt - 1 Nos b) MCB TPN 40 A 25 KA 415 V- 1 No c) MCB SPN 25 A 25 KA 230V - 5 Nos. d) Bus bar, Din rail , Neutral link Make - L&T/Indoasaian/Legrand/ABB/Schneider
S&F in repair/replacement of building Security light fitting 30/35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. Make: Wipro/ Bajaj/ Jaquar
M&L for cutting existing road/hard and dence soil not exc 45x50 cm in wide & depth getting out excaveted materials for laying GI tube; returning filling & well rammin watering finish surface 10 cm from top using PCC 1:3:6 not less than 4 inch thick; including removal of surplas soil all as per directed.
S&F of HDPE pipe 50 mm dia, PN-10 for laying in ground, raod crossing etc for cable protection including necessary fittings, clamps for supports, etc all as. Make-Tata/Jindal/Surya prakash.
M&L Earthing complete with galvanised iron strip 32X6mm earth plate electrode 600×600x6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion Note: (1). 7.5 RM GI strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately. (2) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of GI earth plate.
M & L for earthing chemical with copper plated 50 mm dia pipe 3 mtr long (100 microns) including Electrodite 50 Kg buried directly in ground including earth bore hole work (earth bore not less than 3 Mtr deep below normal ground level and connected to copper earth strip of size 20×3 mm by means of copper nuts bolts with washers and connected as per following specifications complete all as directed by Engineer-in-Charge. (a) Product Model: ASEEL 19 CP, 3 meter long (Copper Plated) – 100 microns . Fast Electrode, Model FE 80 mm 3 mtr (Pure Copper Single Pipe), Outer Dia is 80 mm with a wall thickness of 2 mm, Inner Dia is 26 mm with a wall thickness of 2.6 mm, Overall Length is 3000 mm, External Corrosion Protection: Copper Plated (100+ microns), Internal Corrosion Protection: In addition to Copper Plated (100+ microns), a ground breaking corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance. Conforms to IS: 3043 - 1987 i.e., Code Of Practice For Earthing (+ 10%) variations in dimensions applicable. (b) Electrodite backfill: Fast Electrode Earth Enhancement Compound, Manufactured using Eco - Friendly minerals, Blended homogeneously with conductive carbon(s), Resistivity: < 5 ohm-metre (In ideal moist conditions); > 5 ohm-metre (Dry Conditions), Ph Value: 7.0 - 8.5, High water retention capacity, Hygroscopic, Ionic & Electronic conduction, Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil which is a crucial aspect in the performance of an earthing system. Packing Size : 2 Bags of 25 kilograms, Recommended for normal soil conditions. Conforms to IS : 3043 – 1987. (c) Installation of earthing with bore well machine complete for bore exceeding upto 4.5 meter below ground level complete all as specified and directed by Engr-in-Charge.
Supply, installation, test, and commissioing of online UPS for 30 min backup three phase AC input and three phase out put 3x400V AC (3Ph+N), microprocessor controlled generator compatible, auto by pass and emergency power off, pure sign wave with following specifications of capacity 60KVA Make: Power One Model PMP 60 or equivalent in Microtech/Siemens/ V Guard/Labotech/Sukam/Tata Liebert/APLAB/Luminous/Protect Services/Sinetrac complete all as specified and directed by Engineer-in-charge. (A) INPUT : (i) Voltage- 400V AC / 415 VAC (3Ph + N), (ii) Voltage Range 290VAC ~ 480VAC (Ph-Ph), (iii) Frequency Range 45Hz to 55Hz (B) OUTPUT : (i) Voltage 380VAC /400VAC / 415VAC (3Ph + N), (ii) Voltage Regulation ± 1% ( battery Mode), (iii) Frequency & Waveform ± 1% 50 Hz / 60 Hz & Pure Sine Wave, (iv) Harmonic distortion less than or equal to 2% THD ( linear load), (v) Harmonic distortion less than or equal to 5% THD ( non linear load), Efficiency not less than 92%, (vii) Overload Capability 110% for 60 min, 125% for 10 min, 150% for 60 sec , (viii) Protection- Over voltage, Under voltage, Short Circuit, Over temperature, Overload, (ix) Transient Response- ±5% (Dynamic Regulation for 10% to 90% step linear load), (x) Transient Recovery < 1 cycle (Steady state condition after 10% to 90% step linear load), (xi) Crest Factor - 3:1 (C) Battery & Charger : (i) Battery Type VRLA SMF / Tubular / NICAD / Lithium ion (ii) Battery Numbers 12V x 32 Nos (29 ~ 32 Nos adjustable), (iii) Battery Voltage 384 VDC (348V-384V adjustable), (iv) Charging Current Battery 384 VDC (348V-384V adjustable), Default 10A; Maximum 40A, (E) STANDARDS : (i) EMI 62040-1, (ii) EMC 62040-2, (iii) Performance 62040-3, (iv) Quality Standards ISO 9001,ISO 14001,ISO 45001& ISO 50001 (F) COMMUNICATIONS : (i) Network Management RS232, RS 485 MODBUS, SNMP (G) ENVIRONMENTAL PARAMETER : (i) Ingress protection IP21, (ii) Operating Temperature 0- 50 °C, (iii) Humidity 0- 95% (Non Condensing), (iv) Altitude 0-1500 M without derating
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 50 Sqmm 3.5 core including necessary connection and providing cable lugs as required all as specified. Make: GRANDLEY / POLYCAB / KEI
S & F in repair MCCB 100 Amps, 36 KA Four Pole, MCCB with Thermal Magnetic Protection Unit 415 Volts including connecting up complete in existing panel with Lugs/Glands all as specified and directed with following specifications. Make: Legrand, Schneider, ABB, Siemens (i) Range: 100A, Ics=100%Icu, Four Optimum Frames (ii) Thermal Adjustable – 0.8 to 1In (iii) Breaking Capacity – 36kA (iv) Adjustable sensitivity: 0.03 - 0.3 - 1 - 3 A (v) Adjustable tripping: 0 - 0.3 - 1 - 3s (vi) Suitable for Isolation
S & F in repair MCCB 250 Amps, 36 KA Four Pole, MCCB with Thermal Magnetic Protection Unit 415 Volts including connecting up complete in existing panel with Lugs/Glands all as specified and directed with following specifications. Make: Legrand, Schneider, ABB, Siemens (i) Range: 100A, Ics=100%Icu, Four Optimum Frames (ii) Thermal Adjustable – 0.8 to 1In, (iii) Breaking Capacity – 36kA (iv) Adjustable sensitivity: 0.03 - 0.3 - 1 - 3 A (v) Adjustable tripping: 0 - 0.3 - 1 - 3s (vi) Suitable for Isolation Note : A sum of Rs 16,600.00 towards sch of credit shall be deducated to arrive the contract sum.
H R ENGINEERS (BID ID -3158623)
sahajanand const co. (BID ID -3158990)
Atharva Enterprises (BID ID -3159330)
M/s Mukesh Engineers (BID ID -3158939)
Shree Ayyappa Engineering (BID ID -3159175)
sapana enterprises (BID ID -3163551)
Advait Enterprises (BID ID -3164559)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .