Electrical Work in c/w Augmentation of running Rooms at MCTM & SVDK by providing 10 Nos. additional rooms
251-J-Elect-T-09-2025-26
251-J-Elect-T-09-2025-26
Open
6 Months
Unknown (Unspecified Location)
₹0
₹41,900
15 Jun 2026
15 Jun 2026
23 Jun 2026
Description:- Supply and Erection of modular metal boxes concealed boards with white finish
(Myrius), Schneider (Zencelo), Anchor (Ave) or similar. Metal boxes boards are to be concealed in the wall for 12 Module
Description:- Supply and Erection of modular metal boxes concealed boards with white finish
(Myrius), Schneider (Zencelo), Anchor (Ave) or similar Metal boxes boards are to be concealed in the wall for 8 Module
Description:- Supply and Erection of modular metal boxes concealed boards with white finish
(Myrius), Schneider (Zencelo), Anchor (Ave) or similar make. Metal boxes boards are to be concealed in the wall for 6 Module
Description:- Supply and Erection of modular metal boxes concealed boards with white finish
(Myrius), Schneider (Zencelo), Anchor (Ave) or similar Metal boxes boards are to be concealed in the wall for 4 Module
Description:- Supply and Erection of modular metal boxes concealed boards with white finish
(Myrius), Schneider (Zencelo), Anchor (Ave) or similar Metal boxes boards are to be concealed in the wall for 3 Module
tech. specification IS/IE rules and site requirement. JAMMU DIVISION-ELECTRICAL/NORTHERN RLY
tech. specification IS/IE rules and site requirement.
per tech. specification IS/IE rules and site requirement.
as per tech. specification IS/IE rules and site requirement.
multistranded copper conductor s/core cable1100 Volt conforming to IS-694 (latest version), make Finolex, Havells, Polycab, KEI in the recessed PVC conduit pipe 25 mm dia as required at site.
copper conductor cable 1100 Volt 1.5 Sq.mm multi stranded confirming to IS-694 latest in the existing PVC pipe.
Description:- Supply, laying, fixing, testing and commissioning of 2.5sq mm FRLS, PVC insulated
version),make Finolex, Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as perTech Spec-I attached, IS & IE rules.
Description:- Supply, laying, fixing,testing and commissioning of 4 sq mm FRLS, PVC insulated
version),make Finolex,Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as perTech Spec-I attached, IS & IErules.
multistranded copper conductor s/core cable1100 Volt conforming to IS-694 (latest version), make Finolex, Havells, Polycab, KEI in the recessed PVC conduit pipe 20 mm dia as required at site.
9537/Pt.III/1983 or Latest Version with accessories, junction box, etc including making chase, plastering/clamping etc as per technical specifications.
Description:- Supply, fixing, testing and commissioning of LED tube light system wattage 18 Watt
connection from ceiling rose as per ISS/IR rules & site requirement as per CEE/N.Rly. Specification No.CEE/NR/121-Elect/PS/2018 (Rev '3') Dated 28.06.2018. & CEE/NR/121-Elect/PS/2019(Rev-04) dt 04.11.2019 with correction dt.10.02.2020 or latest.
Description:- Supply, fixing, testing and commissioning of LED down lighter,housing aluminum die
complete with all mounting arrangement,accessories complete of make Phillips,Bajaj, Havells or similar conforming to CEE/NR's spec. No.CEE/NR/121-Elect/PS/2018 (Rev-'3') or latest & PCEE/NR's spec. No.PCEE/NR/121-Elect/PS/2019 (Rev-'4') or latest
WHITE INBUILT DRIVER as per CEE/NR Specification. No.CEE/NR/121- Elect/PS/2018 (Rev '3') Dated 28.06.2018
Description:- Supply, fixing, installation, testing and commissioning of energy efficient 230V,50 Hz
speed-120 to 260 V AC with 5 step speed control electronic regulator, copper winding complete as per IS : 374-1979 or latest IE rule & site requirement. Make Bajaj, Usha, Havells, Crompton, Orient or equivalent.
propeller type exhaust fan complete as per IS, IE rule & site requirement.Make Usha, Orient,Bajaj or equivalent
21 JAMMU DIVISION-ELECTRICAL/NORTHERN RLY 21 Description:- Supply, fixing,testing and commissioning of 3-pin ceiling rose 5 Amp capacity on existing MS/PVC conduit junction boxes/casing caping Anchor, Cona, Kinjal, SSK or equivalent as per IS, IE rules and site requirement.
Description:- "Design, manufacturing, supply, erection, testing & commissioning of wall mounted
MCCB 4 Pole250 A 35 KA B/C - 01Nos. (ii) Outgoing MCCB 4Pole 125 A 35 KA B/C - 05Nos. The Panel shall becomplete with 250 Amps. Copper bus bars for Phases and 125 Amp. For Neutral and as per explanatory note. "
Description:- Supply, erection, testing and commissioning of the following Double door wall
comprising; (i) Incoming MCCB 4Pole 63 A 35 KA B/C - 1 No. (ii). Outgoing MCB 6 to 32 A. SP 10 KA B/C (4 Nos. On each Phase) - 12 Nos.
of size 18"-24"with 2 nos. ultra violet UV tube lights of 15-20W each & HT current electrified grid system.
Description:- SITC of 35 Ltrs. water heater geyser BEE 5 star rating 2KW glass coated heating element , CFC free high density PUF insulation , inner tank extreme hard water resistance , suitable
Monza EC or equivalent model as Racold model Eterno 2 or make AO Smith model HSE-vas- 035L.Note: sample is to be submitted for consignee approval before making supply of material is to be accepted through OEM or OEM authorized dealer only
energy efficient compressor cooling capacity LTR/HR150, storage type ,confirming to IS-1475-1PART 1, of 2001 or latest make blue star, voltas or similar.
capacity,30mA sensitivity with Metal enclosure.
Description:- Supply, installation and commissioning of 1400 VA sinewave inverter with following features of make SUKAM, Luminous or Microteck with supply of tubular plate 150 AH batteries of make Exide model IT500 or similar. The complete inverter unit with batteries should be housed in
135-275 35 Volt (iii) Output voltage 220 Volt + 8% (iv) Output Waveform Sinewave (+) Output 1400 VA or above (vi) LED display Main ON, Inverter ON, Low Battery, Main ON, Inverter ON, Low Battery, Over Charge, Mains Low and High Input Voltage (vii) Protections: Over Load, Short Circuit, Low Battery Over Charge Mains Low and High Input Voltage.
Description:- Supply & erection of 5M pole with double arm bracket hot dip galvanized octagonal pole with top 70 mm and bottom 130 mm around face made of 3 mm thick, steel base plate size
foundation (1:2:4) painting, earthing and foundation GI nut, bolts with washer and smart pack junction box with single pole MCB and terminals as per explanatory note
Description:- Supply and erection of minimum 45 W LED Street light fitting operating voltage single phase 230 volts AC, 50Hz complete with all accessories as per CEE/NR Specification.
dated 04.11.2019 or latest respectively including connection with 2x2.5 sq.mm PVC insulated multi stranded FRLS copper conductor cable, testing, commissioning & earthing required and as per explanatory note. Square
Foot Description:- Design, Manufacture, supply, fixing, testing and commissioning of single sided LED
(Rev'3') Dated 28.06.2018 or latest. and as per site requirement. Note:- Static/single sided board of different sizes name is required. prior approval of message color and size to be taken from competent authority.
JAMMU DIVISION-ELECTRICAL/NORTHERN RLY Description:- Transportation, Laying, underground/road/Railway track, recessing in platform /wall 32 along with Rly. Track/in laid RCC/GI pipe as required 1.1 KV grade LT XLPE insulated armoured, aluminium conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks, provision of cable route marker as per Tech. Specification including end terminations with Aluminium Clamping socket/lugs, testing and commissioning of Above 25 sq.mm
Description:- Design, manufacturing of floor mounted MS feeder post made of MS sheet 16 SWG
having cable glands 2 Nos. duly grouted with cement concrete ratio 1:2:4 duly earthed with earthing terminals.
Description:- Earthing arrangement by providing earth electrode of GI pipe 50 mm dia (B class) 4.5 meter long with flange including 6 SWG GI earth wire from earth pipe to connecting point on switch
Tech specification at annexure 'A' relevant ISS & IE rules and site requirements. A suitable CI/MS/RCC cover as approved by Rly . Representative, cover with locking arrangement shall be provided.
mentioned in explanatory note.
relevant IS and as per IS 3043/1987(or Latest Version) 300mm deep in ground/recessing in floor as required.
Description:- Supply, installation and commissioning of light weight wall mounted voltage stabilizer confirming to IS: 8448 suitable with toroidal care transformer having capacity 4 KVA, Input Voltage
type instant and start switch, under voltage and over voltage cut off with indicators, Digital Voltmeter and Ammeter with soft type selector switch for measuring input & output voltage, indicator for power ON and timer ON. IS 8448 Latest version/Make Microtek, V-Guard or equivalent with RDSO/ISO/BIS/equivalent certification
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tenderdocument251-J-Elect-T-09-2026-27.pdf
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
GCC2022.pdf
ATTACHMENT
ACS1.pdf
ATTACHMENT
ACS2.pdf
ATTACHMENT
ACS3.pdf
ATTACHMENT
ACS4.pdf
ATTACHMENT
ACS5.pdf
ATTACHMENT
ACS6.pdf
ATTACHMENT
2024_05_14ClarificationregardingsubmissionofAnnexure-VofGCC.pdf
ATTACHMENT
GCCACS9.pdf
ATTACHMENT
CorrectionSlipNo7GCCofApr-2022.pdf
ATTACHMENT
CorrectionSlipNo8GCCofApr-2022.pdf
ATTACHMENT
CorrectionSlipNo10GCCofApr-2022.pdf
ATTACHMENT
Download all tender documents and submit your bid