Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | ₹8.0 L | L1 | Accepted-AOC awarded to lowest bidder |
| 2 | L2₹8.1 L+₹16,201.40 (2.03%)Rejected-Finance | ₹8.1 L+₹16,201.40 (2.03%) | L2 | Rejected-Finance highest bidder |
| Sl No | Description | Qty | Unit | K SUNDARA PANDIAN L2 | S PALANIVEL L1 |
|---|---|---|---|---|---|
| 1.00 | Drilling of borewell anywhere in Tamilnadu including transportation from one place to another place within Tamilnadu in alluvial soil or sedimentary strata of clay and sand or sand, stone, shale, pebbles, boulders etc., by first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia by direct or reverse rotatry mud and circulation method using Contractor’s rig, fuel, labour, drilling, betonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit (only Calyx drills are to be used) using only calyx rigs and all other charges etc., complete | 120 | Rm | 1,460 ₹1,75,200 | 1,427 ₹1,71,240 Lowest |
| 2.00 | Reaming from 140/150 mm dia pilot bore to 300 mm dia bore as directed by the TWAD Board Officers upto 60 m Depth ending from ground level sing only calyx rigs and all other charges etc., complete | 120 | Rm | 410 ₹49,200 | 402 ₹48,240 Lowest |
| 3.00Supply and Delivery of Following Size PVC CASING PIPE AS PER IS 12818 / 2010 casing pipe blue colour plain and Slotted pipe including material and transportation charges etc.complete as per std specification. | |||||
| 3.01 | 200mm dia CS PVC Casing Pipe | 120 | Rm | 860 ₹1,03,200 | 836 ₹1,00,320 Lowest |
| 4.00 | Labour Charges for inserting 200mm dia PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the executive engineers of TWAD Board | 120 | Rm | 448 ₹53,760 | 440 ₹52,800 Lowest |
| 5.00 | Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor as directed by TWAD Officers and conducting yield test by ‘V’ notch method. | 8 | Hrs | 2,940 ₹23,520 | 2,888 ₹23,104 Lowest |
| 6.00 | Supply and delivery of Three phase Submersible pumpset clear water vertical wet type submersible pumpset 50X275 suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 %8034 without panel board etc complete as per standard specification. | 1 | Nos | 1,05,000 ₹1,05,000 | 1,02,950 ₹1,02,950 Lowest |
| 7.00 | Supply and delivery of 3 Phase 7.50HP Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 Nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Stan dard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). | 1 | Nos | 20,900 ₹20,900 | 20,770 ₹20,770 Lowest |
| 8.00 | Supplying and delivery of 4.0Sq.mm of PVC insulated and sheathed 3 core flat type copper cable confirming to IS694/ 1990 etc complete as per standard specification. | 150 | Rm | 210 ₹31,500 | 206 ₹30,900 Lowest |
| 9.00 | Labour charges for the erection of 5HP submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. | 1 | Nos | 13,010 ₹13,010 | 12,820 ₹12,820 Lowest |
Tender Value
₹8.2 L
EMD Value
₹8,200
Closing Date
12 Mar 2026, 3:00 pmClosed
COMMISSIONER
MUNICIPAL OFFICE, DEVAKOTTAI
PROVIDING NEW BOREWELL WITH POWER PUMP AT WARD NO.3 THIRUPATHUR MAIN ROAD IN DEVAKOTTAI MUNICIPALITY
2026_MAWS_672449_3
0132/2025/E1
Open Tender
Pumps/Motors
Works
60 days
KARAIKUDI
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹8,200
29 Jun 2026
9 Mar 2026
12 Mar 2026
9 Mar 2026
12 Mar 2026
9 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Drilling of borewell anywhere in Tamilnadu including transportation from one place to another place within Tamilnadu in alluvial soil or sedimentary strata of clay and sand or sand, stone, shale, pebbles, boulders etc., by first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia by direct or reverse rotatry mud and circulation method using Contractor’s rig, fuel, labour, drilling, betonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit (only Calyx drills are to be used) using only calyx rigs and all other charges etc., complete | 120 | Rm | 99 | ₹11,880 |
| 2 | Reaming from 140/150 mm dia pilot bore to 300 mm dia bore as directed by the TWAD Board Officers upto 60 m Depth ending from ground level sing only calyx rigs and all other charges etc., complete | 120 | Rm | 100 | ₹12,000 |
| 3Supply and Delivery of Following Size PVC CASING PIPE AS PER IS 12818 / 2010 casing pipe blue colour plain and Slotted pipe including material and transportation charges etc.complete as per std specification. | |||||
| 3.01 | 200mm dia CS PVC Casing Pipe | 120 | Rm | 101 | ₹12,120 |
| 4 | Labour Charges for inserting 200mm dia PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the executive engineers of TWAD Board | 120 | Rm | 101 | ₹12,120 |
| 5 | Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor as directed by TWAD Officers and conducting yield test by ‘V’ notch method. | 8 | Hrs | 101 | ₹808 |
| 6 | Supply and delivery of Three phase Submersible pumpset clear water vertical wet type submersible pumpset 50X275 suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 %8034 without panel board etc complete as per standard specification. | 1 | Nos | 101 | ₹101 |
| 7 | Supply and delivery of 3 Phase 7.50HP Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 Nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Stan dard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). | 1 | Nos | 101 | ₹101 |
| 8 | Supplying and delivery of 4.0Sq.mm of PVC insulated and sheathed 3 core flat type copper cable confirming to IS694/ 1990 etc complete as per standard specification. | 150 | Rm | 101 | ₹15,150 |
| 9 | Labour charges for the erection of 5HP submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. | 1 | Nos | 101 | ₹101 |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_808161.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .