Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-AOC 1 19 12 KATHAR MEERAN NAGAR THERMAL NAGAR TUTICORIN 628 006 | TUTICORIN | TAMIL NADU | 628006 | L1 | Accepted-AOC Tender Accepted | |
| 2 | L2₹1.4 L+₹6,053.80 (4.53%)Rejected-AOC 5 57 CALDWELL COLONY 1ST STREET TUTICORIN 628 008 | TUTICORIN | TAMIL NADU | 628008 | L2 | Rejected-AOC L2 Bidder |
Tender Value
₹1.1 L
EMD Value
₹1,100
Closing Date
22 Jun 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE/ES
Superintending Engineer-Electrical Systems- Tuticorin Thermal Power Station-Tuticorin
Annual Overhaul maintenance in Generator and its auxiliaries such as Stator water System, Seal oil System and H2 Gas System in unit IV during the Annual overhaul 2020 21
2020_EB_166958_1
SE/ES/TTPS/119/2020-21
Open Tender
Electrical Works
Item Rate
60 days
TTPS
As per BQR conditions in NIT
7 documents required · 7 mandatory
₹0
₹1,100
Yes
31 Jul 2020
5 Jun 2020
23 Jun 2020
5 Jun 2020
22 Jun 2020
5 Jun 2020
90 days
Purging out of hydrogen gas and filling: a. Purging out of Hydrogen in Generator casing by admitting CO2 and then CO2 by air at the time of starting of overhauling. b. Purging of air by CO2 and CO2 by hydrogen, filling up of hydrogen upto the required pressure after completion of all overhauling works.
Charges for opening of Generator Bottom man hole and inspection of internals: Opening the bottom manhole cover for checking and inspection inside the generator casing, Checking of bushing, cleaning inside, phase and neutral side and water header bushing, Providing lighting arrangement to improve the P.I value and closing the man hole after completion of all works.
Charges for carrying out gas tightness checking in the Generator and its Cooling system: Checking the gas tightness in and around the generator casing, seal oil system pipe line joints, Hydrogen gas system pipe line joints by application of soap solution and attending leak if any.
Charges for carrying out the annual maintenance works in Stator water Expansion Tank And Surge Tank: Removing top cover, cleaning inside the tank, dismantling of float valve, checking the floatvalve operation, fixing the valves, refixing the covers after completion of all works.
Charges for carrying out the annual maintenance works in Stator water Mechanical Filters and Magnetic Filter: a. Dismantling of mechanical filters, cleaning the filter elements and replace if necessary, reassembling the same after completion of all works. b. Dismantling of magnetic filters, cleaning the filter and replace if necessary, reassembling the same after completion of all works.
Charges for carrying out Stator water Regeneration of polishing unit resins at DM plant : a. Charges for dismantling the pipe lines and shifting the polishing unit from its location, transporting the polishing unit to DM plant for replacing / regeneration of resins, After completion of work at DM plant the same is to be transported from DM plant to repair bay and then to its location. Then connecting pipe lines, charging & checking of leaks b. Draining the old resins from the polishing unit & filling with new resins after completion of treatment with mixture bed in the D.M plant. This works include providing hoses for inlet & out let of polishing unit. c. Changing of all gaskets in the pipe lines of the polishing unit. d. Charges of assisting for re-generation process / chemical treatment.
Charges for carrying out the annual maintenance works in the dehydrating type hydrogen gas drier : Dismantling of hydrogen gas drier top cover and cleaning inside, checking the drain valves and replace if necessary,replacing silica gel and gaskets, checking the heaters and terminal tightness, reassembling the driers after completion of works.
Charges for carrying out the annual maintenance works in seal oil tank & filter : Dismantling of top cover and inside fixtures in SOT, cleaning of the tank, checking the float valve assembly, refixing the inner fixtures and assembly of top cover, dismantling of filters, cleaning the simplex and duplex filter elements, reassembling the filters complete.
Overhauling of Seal Oil Storage Tank : Draining of oil from SOST by drain valve. Dismantling of top cover, Cleaning inside and reassembling the top cover after completion of all works.
Charges for carrying out improvement of I.R.value and P.I.value of the Generator stator winding : Drying out of stator conductor by admitting hot air till to get satisfactory P.I.value. Transportation of heater chamber from Unit IV packet store to Unit V workspot at 13.5mtr floor, Connect the instrument air hose with the heater chamber, Connect the hot air m.s pipe line arrangement with heater and generator stator, Arranging the LT 3phase power supply to heater chamber, Providing lighting arrangement for observing the hot air admission and drying out stator conductor, Carring out of drying process till getting satisfactory P.I.value, After completion of all works disconnection of power supply and lighting arrangement and restoring the tool piece joints with the stator water pipe lines, The drier unit have to be dismantled and shifted to the pocket store.
Charges for carrying out the DC Cable Polarity changing at AVR panel in excitation system : Charges for changing the DC cable polarity in the AVR panel and checking the terminal tightness,checking the tightness in the excitation field cable in the generator brush gear.
Charges for carrying out annual maintenance works in Unit Service Transformers A & B : Opening of HV side oil chamber top cover and draining of oil if any collected inside cleaning of oil chamber. Disconnection of HV cables and LV links cleaning and assist for MRT testing and commissioning Restoring of HV cables and LV links on completion of all works.
Charges for carrying out Stator water Regeneration of polishing unit resins at DM plant : a. Opening of manhole covers in UST LV bus duct for inspection and for carrying out the maintenance works. b. Cleaning of LV bus duct bar and inspection of bus support insulators and replace the support insulator if any required in one number bus duct. c. Tightness checking of all the rigid joints and flexible joints in one bus duct. d. Tightness checking of all the rigid joints and flexible joints in one bus duct. e. Restoration of all man hole covers after completion of all works in one bus duct.
Charges for Cleaning work carrying out of UST-A&B Transformer in Unit 4 : Labour charges for Cleaning of UST - 4A & 4B of the Unit IV with soda karam and water during completion of overhauling works of the Unit IV.
Charges for carrying out annual maintenance works in LT Motors in Generator & its aux. systems : Removal of terminal covers, disconnecting power cables, lifting the motor if necessary,opening of grease cup and removal of old grease from the bearings, packing of new grease, cleaning the motor and checking the terminal tightness, measuring the IR values, connecting the power cables and closing the terminal covers.
Labour charges for painting of one coat of enamel paint to generator outer casing. Area of the Generator outer casing is 108 Sq mt. (Paint will be supplied by contractor)
KUMAAR ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .