Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.7 LAccepted-AOC | L-1 | Accepted-AOC tender accepted due to lowest tenderer | |
| 2 | L-2₹9.9 L+₹23,176.50 (2.39%)Rejected-Finance 122 SAMHARIYA ASOPUR TANDA AMBEDKAR NAGAR UTTAR PRADESH 224190 | AMBEDKAR NAGAR | UTTAR PRADESH | 224190 | L-2 | Rejected-Finance Not being L1 | |
| 3 | L-3₹10.1 L+₹42,388.60 (4.38%)Rejected-Finance | L-3 | Rejected-Finance Not being L1 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
19 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Niwaru
AGE (I) Niwaru
AGE(I) N-28 OF 2022-23 PROVN OF URINAL BLOCK AT TRANING AREA OF 24 RAJRIF and 18 BIHAR AT NIWARU MILITARY STATION AT NIWARU MIL STN UNDER AGE (I) NIWARU
2022_MES_558987_1
AGE(I)/N-28 of 2022-23
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Niwaru
Class E
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Niwaru
₹24,000
Yes
9 Dec 2022
20 Oct 2022
21 Nov 2022
20 Oct 2022
19 Nov 2022
5 Nov 2022
Amount
M&L for Surface excavation not exc. 30 cm deep and averging 15cm deep and getting out in soft/loose soil, complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches not exc.1.5 m wide and not exc.1.5 m in depth for foundation or for shafts, walls, manholes etc not exc.10 Sqm on plan and getting out in soft/loose soil, complete all as specified and as directed by Engr-in-Charge.
Returning,filling in, including spreading, levelling watering and well ramming in layers n.exc 25 cm in hard/dense soil, complete all as specified and as directed by Engr-in-Charge.
Removal of excavated soil to a distance exc. 250m but not exc 500 m and depositing where directed, complete all as specified and as directed by Engr-in-Charge.
Removal of surplus excavated material to a distance not exc.50 Mtr and depositing where directed at a level not exc. 1.5 Mtr above the starting point, complete all as specified and directed by Engineer-in-Charge
Earth filling under floors including spreading, levelling, watering and well ramming in layers not exc 25 cm thick. Note :- Soil obtained from excavation under item 1,2 here-in-before shall be used for filling.
M & L for hardcore(broken stones & boulders) of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 , complete all as specified and as directed by Engr-in-Charge.
M& L for Damp proof course 40 mm thick in cement concrete 1:2:4 Type B0 to horizontal or vertical surfaces including necessary formwork , complete all as specified and as directed by Engr-in-Charge.
Supply only Integral waterproofing compound, complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 15mm thick in cement mortar 1:4 on surfaces or surface other than fair face of brick work of walls, finished fair & even, complete all as specified and as directed by Engr-in-Charge.
M&L rendering 10 mm thick in CM(1:6) on brick walls or concrete surface, surface finished even and smooth without using extra cement , complete all as specified and as directed by Engr-in-Charge.
M&L rendering 5 mm thick in CM(1:3) on ceiling, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M&L for Cement concrete type E2 1:5:10 (40 mm graded aggregate), 75 mm thik as in sub base, complete all as specified and as directed by Engr-in-Charge.
M&L Plain Cement concrete Type B-0, 1:2:4 (12.50mm crushed stone graded aggregate), 25 mm thick as in as layer in floors, complete all as specified and as directed by Engr-in-Charge.
M&L for screed bed in CM (1:4), 20 mm thick in floor, complete all as specified and as directed by Engr-in-Charge
M & L Non - skid Ceramic colour tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed by Engr-in-Charge.
M & L for coloured Glazed ceramic tiles in vertical surface of Size 450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 10mm thick rendering, complete all as specified and as directed by Engr-in-Charge.
M&L for providing 75 mm thick PCC 1:3:6 type C-2 (40 mm graded stone aggregate) as in plinth protection, ramp etc, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M&L for reinforced cement concrete (M-25) (20 mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span including necessary form work, complete all as specified and as directed by Engr-in-Charge.
M&L for reinforced cement concrete (M-25) (20 mm graded stone aggregate) in slab supported on walls, beams and columns in floors, roofs, shelves and the like, complete all as specified and as directed by Engr-in-Charge. Note :- Reinforcement & formwork shall be measured and paid for separately., complete all as specified and as directed by Engr-in-Charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete, complete all as specified and directed by Engr-in-charge.
S&F deformed or twisted mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips, complete all as specified and directed by Engr-in-charge.
All as per item no No.24 above but 6 to 8 mm dia in stirrups, spacers and binders
M&L for preparation of new plastered surfaces and applying two coats of dry distemper of approved shade/tint over a coat of primer on walls all as specified & directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of white wash on ceilling , complete all as specified and directed by Engr-in-charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint of approved shade on walls all as specified & directed by Engineer-in-Charge
S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia thresh old bar and filling hollow of frame with plain cement concrete Type C-0, 1:3:6 (using 12.5 mm graded crushed stone aggregate) of sizes of frame 105 mm x 60 mm , complete all as specified and directed by Engr-in-charge.
S&F Factory made Plain framed,second class hard wood panelled shutter (Two panel), 35 mm thick with lock rail and panel of 12 mm thick veneered particle board with commercial veneering on both face. The size of rail and style as per IS-1003 (Part-I), Kiln seasoned and chemically pressure treated, complete all as specified and as directed by Engr-in-Charge.
S&F steel windows with side hung shutters incl projecting type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engr-in-Charge.
S & F 4mm Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and as directed by Engr-in-Charge.
M&L Mild steel springs for doors, 150 mm, ordinary rat tail rod pattern springs including roller and roller plate complete, complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide premier, all as specified and directed by Engineer-in-Charge.
M&L for preparation of new untreated wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
S&F aluminium anodised barrel tower bolt 200 mm, extruded section, complete all as specified and as directed by Engr-in-Charge.
S& F aluminium anodised sliding door bolts with hasp and stapple extruded section or cast aluminium alloy 300 mm long, complete all as specified and as directed by Engr-in-Charge.
The surface shall be painted with one coat of polymeric primer @0.30 Kg per Sqm, conforming to IS : 3384. A layer of APP based polymeric membrane 3mm thick (min), weighing not less than 3.5 Kg/m2 reinforced with polyster non woven fabric (weighing not less than 150 gm/Sqm). Application of polymeric membrane shall be by torch application all as per manufacturer instructions. and finally applying one coat of bitumen @ 1.2 Kg/Sqm on APP membrane before application of aluminium paint, complete all as specified & directed by Engr-in-Charge.
M & L one coat of aluminium paint over APP Membrane all as specified and directed by engineer in charge, complete as per manufacturer specification and directed by Engr-in-Charge.
M&L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified & directed by Engr-in-Charge.
M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface, complete all as specified & directed by Engr-in-Charge.
M&L for new galvanised steel water tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors of following sizes:- complete all as specified and directed by Engineer-in-Charge.
(a) 15 mm bore
(b) 20 mm bore
3 layer rotational moulded polyethylene water storage tanks white colour 500 ltr Capacity (Cylindrical vertical with closed top) with 20 mm Brass ball valve, epoxy coated aluminum rod, plastic ball etc, hoisted and fixed in position including tank Nipple inlet and outlet and conneting pipes all as specified in SSR Part-I, complete all specified and as directed by Engineer-in-Charge.
S&F Brass Ball valves 20 mm bore high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
M&L for providing circular, raised platform of height 15 cm below the tank and base 10 cm more than the external dia of tank of PVC cylindrical water tank of capacity 500/1000 liters using PCC 1:3:6 type C1 using 20mm graded stone aggregate with smooth finish, complete all as specified and directed by Engineer-in-Charge
S&F PVC connection 15mm bore with 2 Nos PTMT nuts, 60cm long fixed with one end to pillar tap & the other end to stop cock or iron pipe, complete all as specified and directed by Engineer-in-Charge
Soap dish brass CP, complete all as specified and directed by Engineer-in-Charge
S&F PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm PVC (SWR) bends any radius, complete all as specified and directed by Engineer-in-Charge.
S & F 110 mm PVC (SWR) bends any radius, complete all as specified and directed by Engineer-in-Charge.
S & F 75 mm PVC (SWR), junction single, (Single T) equal or unequal, complete all as specified and directed by Engineer-in-Charge.
S & F 110 mm PVC (SWR), junction single, (Single T) equal or unequal , complete all as specified and directed by Engineer-in-Charge.
S&F Cast Iron cowl of 110mm bore, complete all as specified and directed by Engineer-in-Charge.
M&L 100mm Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls, complete all as specified and directed by Engineer-in-Charge.
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified and directed by Engineer-in-Charge.
S&F Concealed stop valve 15mm, copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, complete all as specified and directed by Engineer-in-Charge.
S&F Fancy type Pillar taps, 15 mm dia cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed by Engineer-in-Charge.
S&F Bib taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
S&F angle valve, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
S&F CP bottle trap with internal partition 32 mm size with 300 mm X 190 mm long wall connection pipe and wall flange for WHB, complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous China wash hand basin flat back , white coloured, , size 610x560mm including CP waste coupling, Bracket but excluding taps, waste chain & plug, complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous China urinals, bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe including waste pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern, complete all as specified and directed by Engineer-in-Charge.
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite, complete all as specified and directed by Engineer-in-Charge.
Cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate in surface channels of drains and benching including finishing the top of benching even and smooth using extra cement (forming fair finished channel shall be measured & paid for separately), complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 75 cm inner girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc, complete all as specified and directed by Engineer-in-Charge.
M & L Reinforced concrete 150 mm pipes,class NP-2, laid and jointed complete with collars of bore of pipes, complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe, complete all as specified and directed by Engineer-in-Charge.
Providing Precast Cement Concrete Type B1 (1:2:4) using 20 mm graded aggregate set CM 1:4 as in manhole cover slab including necessary form work, complete all as specified and directed by Engineer-in-Charge.
PCC type B-1(1:2:4) using 20mm graded stone aggregate as in bed plate coping etc slightly rounded angle, complete all as specified and directed by Engineer-in-Charge.
M&L Soakage wells of 3.6 m dia and 6.0m effective depth including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of std size, all as per Drg no- CEJZ/2004/TD/S-35 dt 11-05-04, complete all as specified and directed by Engineer-in-Charge.
M&L On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, complete all as specified as PS and directed by Engineer-in-Charge.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes covered with 3mm thick hylam/phenolic laminate while sheet cover for mounting switches, sockets, fan regulators as required for the following
(a) One light / fan controlled by one switch.
(b) One socket outlet 6 amp controlled by one switch on the same board with other switches.
S&F switch piano flush button type 230 / 250 V grade on top covers single pole one way 6 amp, complete all as specified and directed by Engineer-in-Charge.
S& F socket outlet 2 in 1, 2, & 3 pin, 6 amp, flush type multipurpose use flush mounting type 230 / 250 Volts grade (ISI Marked) on top covers complete, complete all as specified and directed by Engineer-in-Charge.
S& F Celling rose 3 plates polycarbonate body complete, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing wall mounting box type LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed by Engineer-in-Charge.
S & F MCB DB SPN 4 way double door suitable for 240 V complete all as directed including the following MCBs :- (a) MCB SPN 06 Amps, 10 KA - 01 No (b) MCB SP 06 Amps, 10 KA - 02 Nos
Earthing complete with galvanised steel earth plate electrode 600mmx600mmxthickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electric plate No 3 connected to earth test point/MCB DBs all as specified and indicated compete with funnel, charcoal, dust, salt etc and GI protection pipe, medium grade 15mm bore and GI watering pipe 20mm bore light grade, 40mm thick precast RCC M-15 (nomial mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover, PCC M-15 (Nominal mix) pit, excavation and earth work in any type of soil and connected all as specified .Note:-soil used for filling should be free from stones.
Supply, laying, jointing and testing of 16 Sqmm, 2 core, LT underground cables, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistandred aluminium conductors, ISI marked, laid in trenches/walls/laid under roads/path or encased in GI pipe, complete all as specified and directed by Engineer-in-Charge
Sand cushioning for cables 8 cm below the cable and 15 cm above the cable , complete all as specified and directed by Engineer-in-Charge
Brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick , complete all as specified and directed by Engineer-in-Charge
S&F GI pipe light grade with all fittings and fixed complete to wall & ceilings or laid in floor / trench of size 40 mm bore, complete all as specified and directed by Engineer-in-Charge
Supply and fixing MCB SPN, 240 Volts 6 Amps 10 KA in Existing panel, complete all as specified and directed by Engineer-in-Charge
Supply & laying galvanised Pipe, medium class, supplied and laid including fittings for 25mm dia size of pipe , complete all as specified and directed by Engineer-in-Charge
Supply & fixing 25mm Gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe or for unions, complete all as specified and directed by Engineer-in-Charge
Brick masonry valve pit of size 60x60x60 cm (internal dimension of chamber incl plastering internal and flash pointing external as the work proceeds in same mortar complete with MS sheet cover handle, packing arrangement,earth worth in any type of soil incl removal to n.exc 50 mtr and paint with 2 coats of synthetic enamelled paint over a coat of red oxide primer to steel surfaces, complete all as specified and directed by Engineer-in-Charge
Cutting of existing CI/DI/GI water main pipe in position upto size 150 mm bore for insertion of new tees, branches etc complete all as specified and directed by Engineer-in-Charge (cast iron fittings such as tee, bends, collar, reducer etc shall be measured/paid separately).
Shiv Construction Company
RAMJI LAL & SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .