Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC GROUND FLOOR SHOP NO G 8 JAIRAM COMPLEX NEUGI NAGAR MALA PANAJI GOA 403001 | PANAJI | NORTH GOA | GOA | 403001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.0 L+₹2.0 L (33.9%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹9.6 L+₹3.6 L (60.8%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | Rejected-Technical 7TH FLOOR 711 GERA IMPERIUM GRAND PATTO PANAJI GOA 403001 | PANAJI | NORTH GOA | GOA | 403001 | - | Rejected-Technical Not meeting similar work experience criteria |
Tender Value
₹7.8 L
EMD Value
₹15,600
Closing Date
28 Sept 2024, 11:00 amClosed
Head-IWD
IWD Office, IIT Goa at GEC Campus, Farmagudi, Ponda Goa 403401
Non-Comprehensive AMC of Air Conditioners and Water Coolers at IIT Goa
2024_ITG_823092_1
Non-Comprehensive AMC of Air Conditioners and Water Coolers at IIT Goa
Open Tender
Electrical Works
Item Rate
365 days
IIT Goa
As per Tender Document
2 documents required · 2 mandatory
₹0
₹15,600
Yes
IWD Office, IIT Goa
13 Dec 2024
28 Aug 2024
30 Sept 2024
28 Aug 2024
28 Sept 2024
28 Aug 2024
28 Aug 2024 - 28 Sept 2024
4 Sept 2024
Amount
Servicing of existing installed AC units, i/c checking the units and accessories for functional tests, cleaning of filter units, tightening of loose joints (if any), oiling, greasing and any other minor repairing work etc. as reqd, as per std practice.
Split AC of 1.0/1.5/2.0 TR or equivalent capacity.
Casettee of 2.0-3.0 TR or equivalent capacity
Installation, testing and commissioning of AC units (indoor & outdoor) along with accessories issued by the client i/c handling charges complete etc. as per standard practice.
Split AC of 1.0/1.5/2.0 TR or equivalent capacity.
Casettee of 2.0-3.0 TR or equivalent capacity
Dismantling of existing installed AC units along with accessories and shifting them on another location with in the campus as reqd i/c handling charges complete, as per standard practice.
Split AC of 1.0/1.5/2.0 TR or equivalent capacity.
Casettee of 2.0-3.0 TR or equivalent capacity
Supply and fixing of Flare Nut complete as reqd, as per standard practice for the following types of ACs:
Split/Cassettee AC of 1.0/1.5/2.0 TR or equivalent capacity: cooling copper pipe
Split/Cassettee AC of 1.0/1.5/2.0 TR or equivalent capacity: condensing copper pipe
Replacement of existing burnout Compressor from the outdoor unit in installed position and fixing the new Compressor in the AC unit i/c pressure testing & gas charging i/c handling charges complete etc. as reqd, as per standard practice under buyback of old one. (Make: Highly/Mitsubishi Electric/Hitachi/GMCC/Copeland/Danfoss).
1.0 TR or equivalent capacity Split Inverter AC- R 410 A/R32
1.5 TR or equivalent capacity Split Inverter AC- R 410 A/R32
2.0 TR or equivalent capacity Split Inverter AC- R 410 A/R32
Charging of refrigerant gas in AC units i/c flushing of gas, leakage detection, testing, replacement of filter brazing joints etc. as reqd, as per standard practice.
1 TR or equivalent capacity Split Inverter AC- R 410 A
1 TR or equivalent capacity Split Inverter AC- R 32
1.5 TR or equivalent capacity Split Inverter AC- R 410 A
1.5 TR or equivalent capacity Split Inverter AC- R 32
2.0 TR or equivalent capacity Split Inverter AC- R 410 A
2.0 TR or equivalent capacity Split Inverter AC- R 32
Top up of refrigerant gas in AC units i/c leakage detection, testing, replacement of filter brazing joints etc. as reqd, as per standard practice.
R-32 Refrigerant Gas
R-410A Refrigerant Gas
Pdg. & fixing of extra cooling & condensing copper pipe line along with round electric cable of "stranded copper conductor, PVC insulated & PVC Sheathed" as per IS for connections from outdoor unit to indoor unit/voltage stabilizer etc. as reqd, as per standard practice, suitable for following type of ACs:
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
Pdg. & fixing of extra drain pipe as reqd, as per standard practice, suitable for following type of ACs:
Split AC of 1.0/1.5/2.0 TR or equivalent capacity.
Casettee of 2.0-3.0 TR or equivalent capacity
Pdg. & fixing of AC outdoor unit floor/wall stand as reqd, as per standard practice, suitable for following type of ACs:
Split AC of 1.0/1.5/2.0 TR or equivalent capacity.
Casettee of 2.0-3.0 TR or equivalent capacity
Replacement of existing faulty AC sensors with new sensor of same rating including removing, fixing, testing & commissioning etc. as reqd, as per standard practice, suitable for following types of ACs:
Split AC of 1.0/1.5/2.0 TR or equivalent capacity.
Casettee of 2.0-3.0 TR or equivalent capacity
Repairing (rewinding etc. complete) of existing faulty Condenser Cooling Fan Motor (AC/DC) including removing, fixing, testing & commissioning etc. as reqd as per standard practice, suitable for following types of Acs:
Split AC of 1.0/1.5/2.0 TR or equivalent capacity.
Casettee of 2.0-3.0 TR or equivalent capacity
Replacement of existing fitted faulty Condenser Cooling Fan Motor (AC/DC) with new one of same rating as per IS, i/c handling charges complete etc. as reqd, as per standard practice under buyback of old one, suitable for following types of ACs.
Split AC of 1.0/1.5/2.0 TR or equivalent capacity.
Casettee of 2.0-3.0 TR or equivalent capacity
Replacement of existing fitted faulty AC indoor unit blower motor (AC/DC) with new one of same rating as per IS i/c handling charges complete etc. as reqd as per standard practice under buyback of old one, suitable for following type of ACs.
Split AC of 1.0/1.5/2.0 TR or equivalent capacity.
Casettee of 2.0-3.0 TR or equivalent capacity
Repairing of existing faulty PCB of Inverter AC indoor unit including removing, fixing, testing & commissioning etc. as required.
Split AC of 1.0/1.5/2.0 TR or equivalent capacity
Casettee of 2.0-3.0 TR or equivalent capacity
Repairing of existing faulty PCB of Inverter AC outdoor unit including removing, fixing, testing & commissioning etc. as required.
Split AC of 1.0/1.5/2.0 TR or equivalent capacity
Casettee of 2.0-3.0 TR or equivalent capacity
Replacement of existing faulty PCB of Inverter AC indoor unit with new one of same rating & capacity including removing, fixing, testing & commissioning etc. as required under buyback
Split AC of 1.0/1.5/2.0 TR or equivalent capacity
Casettee of 2.0-3.0 TR or equivalent capacity
Replacement of existing faulty PCB of Inverter AC outdoor unit with new one of same rating & capacity including removing, fixing, testing & commissioning etc. as required under buyback
Split AC of 1.0/1.5/2.0 TR or equivalent capacity
Casettee of 2.0-3.0 TR or equivalent capacity
Replacement of existing faulty Running Capacitor of AC with new one of same rating as per IS including removing, fixing, testing & commissioning etc. as reqd, as per std practice.
Split AC of 1.0/1.5/2.0 TR or equivalent capacity
Casettee of 2.0-3.0 TR or equivalent capacity
Repairing of existing faulty 01 Ph, 240 V, 50 Hz, AC Voltage Stabilizer/Regulator including removing, fixing, testing & commissioning etc. as reqd as per std practice.
Replacement of existing burnout Compressor with new Compressor of same rating as per IS for 80 Ltr Bluestar/Usha Water Cooler i/c installation, testing & commissioning alongwith gas charging (green gas) i/c pressure testing as per standard practice complete in all respects and handling charges under buyback. (Make: Emerson Copeland/ Tecumseh).
Charging of suitable refrigerant gas (green gas) i/c flushing of gas, leakage detection, testing, replacement of filter brazing joints etc. as required as per standard practice. Make: Bluestar/Usha, 80 Ltr Capacity
Supplying & & Replacement of Relay ISI Marked suitable for water coolers of Make: Bluestar/Usha, 80 Ltr Capacity
Supplying & Replacement of Thermostat ISI Marked suitable for water coolers of Make: Bluestar/Usha, 80 Ltr Capacity
Replacement of existing faulty 01 ph, 230V 50 Hz 60-80W fan motor with new one of same rating as per IS including removing, fixing, testing & commissioning etc. as required as per standard practice under buyback. Make: Bluestar/Usha, 80 Ltr Capacity
Replacement of existing faulty Water-Cooled Condenser (Copper) with new one of same rating/size as per IS including removing, fixing, testing & commissioning etc. as required as per standard practice under buyback. Make: Bluestar/Usha, 80 Ltr Capacity
INDIAN AIR CONDTIONING SERVICES (BID ID -3093669)
Suraj Borse (BID ID -3089316)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .