| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.9 LAccepted-AOC | 1 | Accepted-AOC Lowest tenderer | |
| 2 | 2₹18.3 L+₹40,198.40 (2.25%)Rejected-AOC | 2 | Rejected-AOC Other than lowest tenderer | |
| 3 | 3₹18.8 L+₹87,339.40 (4.89%)Rejected-AOC | 3 | Rejected-AOC Other than lowest tenderer | |
| 4 | Rejected-Technical | - | Rejected-Technical REJECTED BEIND NOT ENLISTED IN b(ii) CATEGORY | |
| 5 | Rejected-Technical ALIPURDUAR | ALIPURDUAR | WEST BENGAL | 735204 | - | Rejected-Technical REJECTED BEIND NOT ENLISTED IN b(ii) CATEGORY |
Tender Value
₹18.9 L
EMD Value
₹37,740
Closing Date
22 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (R)
AGE (I) CIF (R) C/o 56 APO
ROVISION OF MAIN POWER SUPPLY WITH AUXILARY TRANSFORMER (250 kVA) AT DARABA UNDER AGE (I) CIF (R)
2022_MES_504578_1
AGE(I)/R-40/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DARABA
Class E and above and category b (i)
8 documents required · 8 mandatory
₹500
AGE (I) CIF (R)
₹37,740
Yes
17 Mar 2022
29 Jan 2022
24 Feb 2022
29 Jan 2022
22 Feb 2022
14 Feb 2022
60 days
Amount
Supply, installation, commissioning and testing of Outdoor type transformer 250 kVA , copper wound step down outdoor type 11000/433 Volt (at no load), 3 phase ,4 wire , 50 cycles per second duly filled with transformer oil , with corrugated off circuit tap links of rating +7.5% to -7.5% @ 2.5% by means of hand operated off load /tap changing gear .The transformer has double wound , transformer oil immersed naturally cooled with external cool tubes core type, delta connected on primary side (HV) and star connected on secondary side (LV) in accordence with vector symbel Dyn-11/Dyn1 (vector group) with neutral brought on secondery side (LV side) and having tappining with at +/- 2.5%/5.0% and 7.5% to be changed to maximum temperature rise should not exceed 40 degree centigrade in oil and 50 degree centigrade in HV/LV winding when measured by resistance method after continues full load run in ambient temparature of 40 degree centigrade and the transformer shall be comprised with the following standard fittings:- (a) Pressure release valve. (b) Themometer pocket on tank cover. (c) Oil temparature indicator. (d) rating plate with terminal marking . (e) Two earthing terminals on tank and cover to facilitate fixing of GI earth strip.
(f) Conservator with oil guage. (g) Oil drain filter valve. (h) Lifting lugs. (j) Oil filter hole with cap / plug including connection complele. (k) Four plain solid cast steel detachable rollers. (l) First fill of transformer oil confirming to as per IS:2026 & BEE certified and testing up to 40 kV dielectric strength all as specified and as directed. (i) Routine test,Ratings and losses are as per IS:1180 (BIS Energy efficiency level -2) shall be carried out at the works.Type test including temperature rise test shall also be carried out at works .Site tests are also to be carried out in presence of company rep. All the tests whether at works/at site are to be conducted in presence of MES rep and all test certificate duly signed by all concerned to be submitted by the contractor to the dept. (ii) The equipment should carry a gurntee of 30 months from the date of despatch or 24 months from date of completion of the contract ,which ever is later. Any defect during this period will be attended in a period of three days including spares and labour without any extra cost to Govt.
M & L for Construction of Platform for installatiom of Transformer of size 3mX2.5mX1.2m with brick work in cement mortar 1:6 earth filling,300 mm thick PCC 1:5:10 type E2, 100 mm thick PCC 1:2:4 type B1 using 20 mm crushed stone aggregate in florring , including XPM fencing (weight not less than 4 kg/sqm) with support of angle iron frame 50 x 50 x 6 mm at four corners with gate with locking arrangements and all steel surfacces well treated with two coats of synethic enamel paint over a coat of red oxide primer complete all as per Drg No CEUZ/TD-1129/96 sheet 1/2
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32×6 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 3 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 3 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion, complete all as specified and directed.
Supply & Erecting in ture vertical position steel tutbular swaged poles ,11 mtr long, complete with mild steel base plate 6 mm thick of size 300 mm X300 mm , B-118 final taper plug, bolts,nuts,washers & screws type 410, SP 55 including drilling of holes of required size & nuts for fixing of cross arms, painting with two coat of alluminium paint over a coat of red oxide and two coat of black bituminous paint for portion embedded in concrete, paining five black and yellow bands at lower portion of pole each of 300 mm hight at 300 mm spacing complete all as specified and as directed. (Note : Excavation ,Earth work & PCC in foundation of poles, coping etc shall measured and paid separately under respective items of sch 'A')
M & L for Cross arms, bracings, supports, clamps (including stay clamps clamps for fixing GI tubes for passing through of cables) and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shapeor size as indicated or directed and inclusive of two coat of aluminium paint over one coat of primer after preparation of steel surfaces complete all as specified and as directed
Supply & Fixing HT 11 kV outdoor type gang operated device Triple pole, mechanically operated air break switch and insulator and mounted on steel frame outdoor type suitable for vertical insulation single nreak provided with locking arrangement consisting of MS channel HT post type insulator (12 insulators) copper alloys hogh pressure assy opening rod of 25 mm GI medium grade complete comfirming to IS: 1318 of 1972 for rated volatge 11 kV and current rating 200 amps complete all as specifed and directed.
Supply and fixing for lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11kV OH line complete all as specified and directed.
S & F danger notice plate of size 25cmx20cmx1.6mm thick, mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamp 25X3 mm, 02 Nos with bolts and nuts of approved , complete all as specified and directed.
M&L for Anti-climbing device; spikes type fabricated out of M.S. bars (round,square and flat)including nuts,bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specifed and directed.
Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m wide for foundation or for shaft, wells, cesspits, manhole, pair house,laying of cable ,pole foundation,stay,laying of pipe etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth and getting out in Hard/dense soil complete all as specified and directed.
Ditto all as per item No 12 above but exc 1.5 mtr depth.
Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge.
M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 ( Using 40mm graded stone aggregate ) as in foundation of poles filling and mass concrete complete all as specified.
M&L for PCC 1:3:6 type C-2 ( using 40mm graded stone aggregate) as in foundation of poles/coping,stay etc complete all as specified.
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in coping and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, i/c dismantling/old PCC complete all as specified.
Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified.
Supply, laying in trenches & testing XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts earth grade having cross sectional area of 120 sqmm 3 core complete all as specified.
Supply, laying in trenches & testing XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts earth grade having cross sectional area of 240 sqmm 3.5 core complete all as specified.
Supply, laying in trenches & testing XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts earth grade having cross sectional area of 150 sqmm 3.5 core complete all as specified.
Supply, laying in trenches & testing XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts earth grade having cross sectional area of 25 sqmm 4 core complete all as specified.
Supply, laying in trenches & testing XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts earth grade having cross sectional area of 10 sqmm 2 core complete all as specified.
Supply & Fix Cable jointing kit for 11 kV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified.
Supply & Fix Cable jointing kit for 1100 V (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 sqmm complete all as specified.
Supply and fix compact air insulated rising main busbar chamber with aluminium busbar 400 amp 4 way and IP 54 protection complete with angle Iron stand (hight from ground 1.5ft) with PCC for grounding legs of Iron stand complete all as directed by Engineer -in-charge
Supply and fix compact air insulated rising main busbar chamber with aluminium busbar 200 amp 4 way and IP 54 protection complete with angle Iron stand (hight from ground 1.5ft) with PCC for grounding legs of Iron stand complete all as directed by Engineer -in-charge
S & F 80 mm bore Steel tubing galvanized(Light grade) conforming to IS -1239 for passing cable under road /floor or fixing to poles for protection of underground cable complete with flat iron 50x6 mm clamps made to shape and 12mm dia bolts, nuts and washers for fixing where required, complete all as specified and directed. (NOTE:- Excavation and earth work shall be measured and paid separatly)
S & F 40 mm bore Steel tubing galvanized(Light grade) conforming to IS -1239 for passing cable under road /floor or fixing to poles for protection of underground cable complete with flat iron 50x6 mm clamps made to shape and 12mm dia bolts, nuts and washers for fixing where required, complete all as specified and directed. (NOTE:- Excavation and earth work shall be measured and paid separatly)
Supply, installation, commmissioning and testing LT Panel outdoor type size not less than 1.0X0.75X0.5 mtr ,double door (IP-54 Protection) floor mounted type CPRI type tested compartmentalised, made outoff 3.15 mm thick CRCA sheet duly powder coated complete with Copper bus bar (TPN) 400 Amps rating made up copper strip not less than 40X2.5 mm duly drilled holes for connection (TPN) and mounted on epoxy based insulators for 3 pahse 4 wire 415 volts 50 Hz, power supply system extended rotary handle Voltmeter, ammeter (Digital type) indicator lamps (RYB)(indicator lamps should display colour of phase as well as phase volatge complete) internal wiring with suitable size of copper conductor PVC insulated and sheathed cable front and rear openable double door with locking arrangement, angle iron frame made out from 40x40x6mm angle iron frame and grouting with PCC,and foundation work and including the following items mentioned below:-
INCOMMER (i) MCCB 3 Phase, 4 Pole 200 Amps,36kA rupturing cap,ICs = 100%Icu with adjustble thermal and fixed magnetic setting 415 volts 50 HZ AC supply - 01 Nos (ii) Digital voltmeter 0 to 500 volt - 01 Set (iii) Digital ameter 0 to 400 amp - 01 Set (iv) Phase indicating lamp RYB with incating voltage in digital LED format ( set of three) - 01 Set OUTGOING (i) MCCB 3 Phase, 3 Pole 100 Amps,25 kA rupturing cap,ICs = 75%Icu with adjustble thermal and fixed magnetic setting 415 volts 50 HZ AC supply - 01 Nos (ii) MCCB 3 Phase, 3 Pole 63 Amps,25 kA rupturing cap,ICs = 75%Icu with adjustble thermal and fixed magnetic setting 415 volts 50 HZ AC supply - 02 Nos
Supply, installation, commmissioning and testing LT Panel outdoor type of suitable size ,double door (IP-54 Protection) floor mounted type CPRI type tested compartmentalised, made outoff 3.15 mm thick CRCA sheet duly powder coated complete with Copper bus bar (TPN) 600 Amps rating made up copper strip not less than 40X5 mm duly drilled holes for connection (TPN) and mounted on epoxy based insulators for 3 pahse 4 wire 415 volts 50 Hz, power supply system extended rotary handle Voltmeter, ammeter (Digital type) indicator lamps (RYB)(indicator lamps should display colour of phase as well as phase volatge complete) internal wiring with suitable size of copper conductor PVC insulated and sheathed cable front and rear openable double door with locking arrangement, angle iron frame made out from 40x40x6mm angle iron frame and grouting with PCC,and foundation work and including the following items mentioned below:-
INCOMMER/OUTGOING (i) MCCB 400A 4P 36kA, with Microprocessor Release- 01 Nos HT METERING AND INDICATIONS (i) Digital VIF Meter -01 nos (ii) Digital Energy Meter,AC Three Phase HT/CT Multifunction DLMS Compliance ofAccuracy Class 0.5s, 3 X 63.5V, 50Hz with Optical & RS232 Port, Backlit LCD/LED/TFT Display, (Measures kWh, kVAh,V,I,kW, 6 months ,history of Energy, Load survey, TOD, Tamper detection & logging, Power On/Off Events, instantaneous parameters of Rating --/5a with display in absence of power. Default PT ratio*: 11kV/110V & confirming to IS : 13379 complete - 01 Nos (iii) CT's 400/5A - 1Set of 3Nos. (iv) Phase indicating lamp RYB with indicating voltage in digital LED format ( set of three) - 01 Set of 3 Nos
Supply, installation, commissioning and testing of 11kV, CT/PT combined unit, Copper Wound, outdoor type, three phase, oil cooled, Powder coated, having following specifications for Potential Transformer 11kV/110V and Current Transformer 15/5A complete P.T: 1. Primary Voltage : 11000 volt 2. Secondary Voltage : 110V 3. Rated Burden : 10VA 4. Accuracy Class : 0.5 5. Frequency : 50 Hz 6. Phase : 3 7. Insulation Class : A 8. IS: 3156 : The Potential Transformers shall conform to IS: 3156 C.T: 1. Primary Current : 15A 2. Secondary Current : 5A 3. Rated Burden : 5VA 4. Accuracy Class : 0.5 5. Frequency : 50 Hz 6. Phase : 3 7. Insulation Class : A 8. IS: 2705 : The Current Transformers shall conform to IS: 2705
M & L for cleaning,rubbing,preparation for painting all surfaces of Steel tubular poles 9 mtr with security light bracket etc complete and painting all surafces of the same with AL paint 2 coat complete with black & yellow stripes (total 5 nos with 30 cm width from bottom of poles) complete all as specified and as directed by Engr-in-charge.
Supply and fixing LED flood light 120 watt 230 V,AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp
Jiwan Singh
Kalsi Engineers and contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .