Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 CrAccepted-AOC 401 SHASTRI NAGAR JAMMU 180004 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | L1 | Accepted-AOC L1 being lowest | |
| 2 | L2₹21.5 Cr+₹1.6 Cr (8.19%)Rejected-Finance | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹22.3 Cr+₹2.4 Cr (12.1%)Rejected-Finance | L3 | Rejected-Finance other than lowest | |
| 4 | L4₹22.7 Cr+₹2.8 Cr (14.2%)Rejected-Finance H NO 159 SEC 04 TRIKUTA NAGAR JAMMU 180012 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180012 | L4 | Rejected-Finance other than lowest | |
| 5 | L5₹22.7 Cr+₹2.8 Cr (14.3%)Rejected-Finance 67 VASANTH AVENUE URBAN ESTATE II JALANDHAR 144003 | JALANDHAR | JALANDHAR | PUNJAB | 144003 | L5 | Rejected-Finance other than lowest |
Tender Value
₹22.8 Cr
EMD Value
₹14.6 L
Closing Date
16 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CHIEF ENGINEER PATHANKOT ZONE
HQ CHIEF ENGINEER PATHANKOT ZONE
PROVN OF OTM ACCN FOR MED REGT (PH-I) AT RATNUCHAK UNDER GE KALUCHAK
2024_MES_642708_1
CA NO CEPZ-46/2023-24
Open Tender
Civil Works
Lump-sum
900 days
GE KALUCHAK
All as per tender documents
8 documents required · 8 mandatory
₹3,000
GE Kaluchak
₹14.6 L
Yes
14 May 2024
16 Feb 2024
23 Apr 2024
16 Feb 2024
16 Apr 2024
9 Apr 2024
Amount
Lumpsum price worked out by the contractor for Buldings works as listed in Schedule 'A' Part-I.
Lumpsum price worked out by the contractor for Internal Water Supply Works as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the contractor for Internal Electrification Works as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the contractor for Hot Water Supply works as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the contractor for Site clearance works as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for Road, Path & Hardstanding as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the contractor for Protective works as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the contractor for Sewage Disposal works as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the contractor for Area Drainage works as listed in Schedule 'A' Part-X.
Lumpsum price worked out by the contractor for External water supply as listed in Schedule 'A' Part-XI.
Lumpsum price worked out by the contractor for RCC Security Wall as listed in Schedule 'A' Part-XII.
Lumpsum price worked out by the contractor for External Electrification as listed in Schedule 'A' Part-XIII.
Supply and fixing of DBOX x MCB Protected Socket with sheet steel Enclosure single pole 25 Amp with 3 pin plug to for AC connection from Socket point to stabilizer complete all as specified and as directed.
Supply and fixing surface /wall mounted batten LED luminair 20 watt 6500 K Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate including flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed by Engr-in-Charge.
Supply and Fixing for LED Lamp 10 watt B-22 holder base with polycarbonate body and aluminium heat sink warm white complete all as specified and directed by Engineer-in-Charge.
S & F High performance IP66 LED Street light 20 watt. Housing made of die-cast aluminium, with street optic lens, with all accessories and connecting up with and including provision of 3 core flexible copper wire of size 1.5 sqmm from ceiling rose, to 20W LED light etc. drawn through and including 32mm bore GI light grade protection pipe upto 1.0m length with suitable fixing accessories on walls, complete all as specified and directed
Supply and fixing factory-made epoxy powder coated Distribution board VTPN 4 ways ,415 Volts with metal door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flushincluding 100 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates. (without MCCB) all as specified and directed. directed.
Supply and fix angle iron stand made out of 50 x 50 x6 mm angle iron and 50 x 6 mm flat suitable for stand for Cold water tank incl painting the stand with 2 coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply, fixing and laying Ductile Iron pipe with spigot & socketed ends centrifugally cast class K9, 150 MM dia bore ISI marked suitable for lead joint in any length laid in trenches complete all as specified and directed by Engr-in- Charge. (Excavation shall be measured and paid separately. Note:- The rate quoted for DI pipes includes for all jointing & jointing materials.
Supply, fixing and laying Ductile Iron pipe with spigot & socketed ends centrifugally cast class K7, 150 MM dia bore ISI marked suitable for lead joint in any length laid in trenches complete all as specified and directed by Engr-in- Charge. (Excavation shall be measured and paid separately. Note:- The rate quoted for DI pipes includes for all jointing & jointing materials.
Supply, fixing and laying Ductile Iron pipe with spigot & socketed ends centrifugally cast class K7, 100 MM dia bore ISI marked suitable for lead joint in any length laid in trenches complete all as specified and directed by Engr-in- Charge. (Excavation shall be measured and paid separately. Note:- The rate quoted for DI pipes includes for all jointing & jointing materials.
S & F of CI sluice valve flanged of size 150 mm bore class PN-1.6 ISI marked with stainless steel spindle and iron wheel head complete with rubber gaskets, nuts, bolts washers and packing materials etc completed all as specified and directed by Engr-in- Charge.
S & F of CI sluice valve flanged of size 150 mm bore class PN-1.0 ISI marked with stainless steel spindle and iron wheel head complete with rubber gaskets, nuts, bolts washers and packing materials etc completed all as specified and directed by Engr-in- Charge.
S & F of CI sluice valve flanged of size 100 mm bore class PN-1.0 ISI marked with stainless steel spindle and iron wheel head complete with rubber gaskets, nuts, bolts washers and packing materials etc completed all as specified and directed by Engr-in- Charge.
S & F of CI sluice valve flanged of size 80 mm bore class PN-1.0 ISI marked with stainless steel spindle and iron wheel head complete with rubber gaskets, nuts, bolts washers and packing materials etc completed all as specified and directed by Engr-in- Charge.
Construction of valve pit chamber of sizes 1.2 x 1.2 x 1.2 m with brick masonary one brick thick wall in cement mortar (1:4) on 100mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation complete including necessary exc and earthwork in any type of soil, formwork, 15 mm thick cement & plaster rendering internally all around over brick wk & externally upto 15cm below normal GL with 10 SWG thick MS sheet cover incl 40 x 40 x 6mm MS angle iron frame fixed with locking arrangement and painting with one coat of red oxide primer and two coats of black Bituminous paints complete all as specified and directed by Engr-in-Charge.
Construction of valve pit chamber of sizes 0.90 x 0.90 x 1.05 m with brick masonary one brick thick wall in cement mortar (1:4) on 100mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation complete including necessary exc and earthwork in any type of soil, formwork, 15 mm thick cement & plaster rendering internally all around over brick wk & externally upto 15cm below normal GL with 10 SWG thick MS sheet cover including 40 x 40 x 6mm MS angle frame fixed locking arrangement and painting with one coat of red oxide primer and two coats of black Bituminous paints complete all as specified and directed by Engr-in-Charge.
Construction of valve pit chamber of sizes 0.60 x 0.60 x 0.75 m with brick masonary one brick thick wall in cement mortar (1:4) on 100mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation complete including necessary exc and earthwork in any type of soil, formwork, 15 mm thick cement & plaster rendering iternally all around over brick wk & externally upto 15cm below normal GL with 10 SWG thick MS sheet cover including 40 x 40 x 6mm MS angle frame fixed with locking arrangement and painting with one coat of red oxide primer and two coats of black Bituminous paints complete all as specified and directed by Engr-in-Charge.
Supply and fixing for Barbed razer type concertina coil of 1050 mm dia (when unstretched) fixed between the existing ‘V’ shaped angle post and barbed wire over security wall/PCC/ground as per requirement with coil of coverage 7.5 running meter per coil, weight of each coil 14.00 to 14.50 Kg hot dip galavanized and binding with and including MS annealed wire of 0.90mm complete as specified and directed by Engr-in-Charge.
Providing & applying 2.5mm thick road marking strips (retro-reflective) of specified shade/colour using hot thermoplastic material by fully/semi automatic t thermoplastic paint applicator machine fitted with profile shoe heater, driven by experienced operator on road surface incl cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc compete as per direction of Engr-in-Charge and accordanc with applicable specification complete all as specified and directed.
Solar cat eye having 3 LED/side of colour red/yellow to a side (6 Nos) house in tough pressure dia casted aluminium allow of size 125 x 125 x 125 mm with built in steam of suitable length for fixing with approxy LED solar cell battery and light sensor well protected in side under tough under cable for 2 to 3 days (night) after full charge in 8-10 hours make oscar or equivalent make as approved by Engr-in-Charge,complete all as specified and directed.
S & F Stainless steel round road delineator having reflector type red/yellow colour in plastic body protected in side polycarbonated sheet, protected with powder coated wiremesh cage system mouted as approved by Enge-in-Charge, complete all as specified and directed.
S& F Reflective type cat eye having colour red/yellow to a side, casted aluminium allow of size 100 x 100 x 20 mm with built in steam of suitable length for fixing with protected in side as approved by Engr-in-Charge,complete all as specified and directed.
S & F Information board with ACP sheet retroreflective writing one side size 600 x 900 mm. Made arround of reflective intensive tape dully fixed on angle iron frame 40 x 40 x 4 mm frame with aluminium sheet both side 2 mm thick as required with PCC 1:4:8 forpost and PCC 1:2:4 for plateforms size 5'x3' complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of step-down copper wound transformer 11KV/433 Volts, 3 phase 50 Hz 400 KVA outdoor type,vectorgroupDyn11,Energyefficiencylevel 3, with off load tap changing arrangement on HT sidetovarysecondaryvoltagefrom+2.5%to +7.5%instepof2.5%includingsuitablecable entry boxes both on HT side to receive 95 Sqmm 3 core XLPE cable and on low voltage side to accommodate XLPE cable of suitable sizecomplete in all respect with standard accessories and fitment confirming to IS:1180 part I 2014(and with latest amendments). Primary side Delta and secondary side Star. The salient feature of transformer shall be as follows: - (a) Transformer shall be oil immerse, naturally self- cooled copper wound, winding core type MS radiator cooled tank complete with first fill of ISI marked transformer oil as per IS:335 of 1980 with dielectric strength not less than 40KV. The temperature of oil shall not rise more than 50degree centigrade to ambient temp and 55 degree centigrade of winding. (b) Transformer shall be provided with the followings: - (i) Rating and diagram plate. (ii) Earthingterminals2Nos. (iii) Lifting lugs. (iv) Thermometer pocket. (v) Air release hole with plug. (vi) Tap changer with locking provision. (vii) Oil temperature indicator. (viii) Bidirectional Roller (ix) Silica gel Breather (c) Quoted rate to include transformer platform 3000x2500x1200mm high with steps and protected with chainlink fencing and hinged door with locking arrangement all as per CEPZ/C-TD/002/13Sht2/5
Supply install, test and commissioning LT Feeder Pillar / Panel board cubical type outdoor Confirming to IS 8623 Part 1 1993, free floor standing / wall mounting factory fabricated made out of 3.15 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and outgoing ACB, MCCB, MCB and TPN Aluminum bus bars of rating not less 1.5 times the rated cap of incomer MCCB / ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom channel of size 75x40 mm . A detachable predrilled gland plateof thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP65 degree of protection , complete as specified and consisting the following switchgears and accessories (Main Panel Board): (a) Main Incoming ACB Draw Out Type of Rating 630Amps Four Pole 50 kA - 01 No (b) Outgoing MCCB FP 415 Volt 350 Amps 36 kA - 01 Nos (c) Outgoing MCCB FP 415 Volt 250 Amps 36 kA - 01 Nos (d)Outgoing MCCB FP 415 Volt 63 Amps 25 kA - 01 Nos (e)Outgoing MCB TPN 415 Volt 25 Amps 16 kA -01 Nos (f) Outgoing MCB TPN 415 Volt 40 Amps 16 kA -02 Nos (g) Outgoing MCB TPN 415 Volt 16 Amps 10 ka -01 Nos (h) Street light timer switch up to 16 Amp single phase with astonomical on off in sheet poly carbonate/MS sheet enclosure (j) LED Type RYB Phase Indicator -01 Set (k) Digital VAFPF Meter -01 Nos (l) CTs - 01 Set
(m) TPN Aluminum bus bar with colour code 1500 APMS (n) Heat resistance sleeve (o) Bus bar support Epoxy 50 mm (p) Brass nut bolt washer 10x15mm (q) Sheet metal work including fabrication, PCC foundation etc (r) Complete wiring with copper cable, thimble etc. (s) Spare Compartments-05 Nos to accommodate Switchgear for Phase II Accn Note: (a) All CTs, PTs shall be as per the rating of the switchgear and of Cast resin type. (b) PCC foundation 0.60 mtr from GL for mounting of Panel is deemed to be included in the quoted rate for the job. (c) Danger Notice plate shall be provided on either facia of the panel. (d) SLD of pannel should be approved by GE before manufacture
All as per Sl Item No 37 herein before but with consisting following switchgears and accessories (Feeder Pillar No 1):- (a) Incoming MCCB FP 415 Volt 250 Amps 25 kA - 01 Nos (b) Outgoing MCCB FP 415 Volt 63 Amps 16 kA - 04 Nos (c) Outgoing MCB DP 240 Volt 25 Amps 10 KA -01 Nos (d) Outgoing MCB DP 240 Volt 10 Amps 10 KA - 02 Nos (e) LED Type RYB Phase Indicator -01 Set (f) Digital VAFPF Meter -01 Nos (g) CTs - 01 Set (h) TPN Aluminum bus bar with colour code 400 APMS (j) Heat resistance sleeve (k) Bus bar support Epoxy 50 mm (l) Brass nut bolt washer 10x15mm (m) Sheet metal work including fabrication, PCC foundation etc (n) Complete wiring with copper cable, thimble etc.
All as per Sl Item No 37 herein before but with consisting following switchgears and accessories (Feeder Pillar No 2): (a) Incoming MCCB FP 415 Volt 63 Amps 25 kA - 01 Nos (b) Outgoing MCCB FP 415 Volt 63 Amps 16 kA - 01 Nos (c) LED Type RYB Phase Indicator -01 Set (d) Digital VAFPF Meter -01 Nos (e) CTs - 01 Set (f) Elecrolytic Aluminium bus bar 200 Amps (g) Heat resistance sleeve (h) Bus bar support Epoxy 50 mm (j) Brass nut bolt washer 10x15mm (k) Sheet metal work including fabrication, PCC foundation etc (l) Complete wiring with copper cable, thimble etc.
All as per Sl Item No 37 herein before but with consisting following switchgears and accessories (Feeder Pillar No 3): (a) Incoming MCCB FP 415 Volt 63 Amps 25 kA - 01 Nos (b) Outgoing MCCB FP 415 Volt 25 Amps 16 kA - 01 Nos (c) Outgoing MCB DP 240 Volt 10 Amps 16 kA -04 Nos (d) Outgoing MCB DP 240 Volt 20 Amps 16 kA - 03 Nos (e) Street light timer switch up to 16 Amp single phase with astonomical on off in sheet poly carbonate/MS sheet enclosure (f) LED Type RYB Phase Indicator -01 Set (g) Digital VAFPF Meter -01 Nos (h) CTs - 01 Set (j) Elecrolytic Aluminium bus bar 200 Amps (k) Heat resistance sleeve (l) Bus bar support Epoxy 50 mm (m) Brass nut bolt washer 10x15mm (n) Sheet metal work including fabrication, PCC foundation etc (o) Complete wiring with copper cable, thimble etc.
M & L earthing complete with galvanised steel earth plate eletrode 600mmx600mm and 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top prjgc, of the plate not less than 1.5m below normal ground level, connected to the Galvanise Iron earth lead 32mmx6mm (GI Strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , reinforced with XPM (weight not less than 4 kg per sqm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to feeder pillers and Transformer all as specified including testing on completion complete all as specified and directed.
M & L earthing complete with galvanised steel earth plate eletrode 600mmx600mm and 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge, of the plate not less than 1.5m below normal ground level, connected to the Galvanise Iron earth lead 32mmx6mm (GI Strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , reinforced with XPM (weight not less than 4 kg per sqmtr) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to feeder pillers and Transformer all as specified including testing on completion complete all as specified and directed.
Supply and fix Integral LED security light luminaire 60W LED 230 volts made of pressure die cast aluminum housing powder coated with high power SMD LED’s lens & toughened glass IP-66, Luminaire efficacy >125 Lumens per Watt, Secondary optics for better light distribution, having inbuilt driver) 4KV internal +10KV SPD, THD<10%, pf>0.95, including making connection with PVC copper conductor cable of 1.5 sqmm to junction box and complete all as specified and directed.
Supply and fix Integral LED security light luminaire 35/36W LED 230 volts made of pressure die cast aluminum housing powder coated with high power SMD LED’s lens & toughened glass IP-66, Luminaire efficacy >125 Lumens per Watt, Secondary optics for better light distribution, having inbuilt driver) 4KV internal +10KV SPD, THD<10%, pf>0.95, including making connection with PVC copper conductor cable of 1.5 sqmm to junction box and complete all as specified and as directed.
Bracket made of GI pipe 40 mm dia (light grade) with attachment of suitable size of MS clams for fixing street light, complete all as specifed and directed by Engr-In-Charge.
S & F Pole mounted junction box one piece fabricated out of 2mm thick MS sheet of size 300x200x100mm, front openable door with hinges, weather proof duly painted internally and externally over a coat of red oxide primer suitable to house and including colour coded 04 Nos aluminium bus bar of 63 Amps rating mounted on insulators, One No MCB SPN 6 Amps mounted on dinrail, internally wired with suitable size of copper conductor, provision of bottom cable entry with cable glands for connecting street light fittings. complete all as specifed and directed by Engr-In-Charge.
Supply and fixing copper cable multistrand PVC insulated PVC seathead 1.5 Sqmm 3 core complete all as specifed and directed by Engr-In-Charge.
S & F cable route indicator of size 100 mm x 100 mm x 5 mm thick GI plate with insertion there on bolted welded to 35 mm x 35 mm x 6 mm angle iron 60 cm long and fixing the same in ground with PCC as required for LT/HT calbe incl necessery earth work complete all as specifed and directed by Engr-In-Charge.
Supply, fixing and testing of water cooler electric driven single phase 230 Volts AC supply energy efficent star rated with CFC free refrigerant, INSITU PUF insulation, approximate storage capacity of 80 ltr and cooling capacity of 40 ltr per hour Make: Voltas/Blue Star/USHA.
Supply and fix Desert Cooler with steel body having 450 mm fan size with Aluminium blade ISI Marked electric driven (Single phase) having nominal air flow capacity 5000 CFM with wall thickness of sheet 1 mm and water tank and body pillar 3.00mm including prewired electirc control panel with immersed pump duly ISI marked pump and fan motor Make: symphony/Khaitan/Kenstar.
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated. Make: Voltas/Hitachi/Carrier.
Supply and install voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with out put voltage stablized at 230V with accuracy of +/_2.5 % and of capacity 03 KVA complete all as specified and directed.
Supply and install voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with out put voltage stablized at 230V with accuracy of +/_2.5 % and of capacity 01 KVA complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank with Incoloy glass-coated heating element 2.0 Kw capacity 50-liter, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, PVC connection pipes two Nos etc all as specified and directed
All as per item No-55 above but 25 ltr cap, all as specified and directed
KAPAHI CONTRACTS PVT LTD
Chandra Construction
Om Parkash Nargotra Constructions Pvt Ltd
Rabina Enterprises Pvt Ltd
SAR AGENCIES
SOOD ASSOCIATES PVT LTD
RAMJI DAS DHAL CONSTRUCTION PVT LTD
M/S BHATIA BUILDERS AND CONTRACTORS
A.V BUILDERS
Beejay Associates Contracts Pvt Ltd
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
BOQ_719524.xls
BOQ Document • 2.51 MB
139686071.pdf
Tender Document • 0.55 MB
TenderDocuments46.pdf
Tender Document • 5.04 MB
binder1.pdf
Tender Document • 5.88 MB
binder2.pdf
Tender Document • 3.97 MB
binder3.pdf
Tender Document • 4.99 MB
binder4.pdf
Tender Document • 2.18 MB
binder6.pdf
Tender Document • 10.29 MB
binder7.pdf
Tender Document • 7.18 MB
binder8.pdf
Tender Document • 7.79 MB
binder9.pdf
Tender Document • 1.22 MB
binder10.pdf
Tender Document • 8.40 MB
139686073.html
Tender Document • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .