| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC | L1 | Accepted-AOC DUE TO LOWEST BID | |
| 2 | L2₹27.6 L+₹2.1 L (8.21%)Rejected-Finance | L2 | Rejected-Finance DUE TO HIGHER BID | |
| 3 | L3₹27.9 L+₹2.4 L (9.29%)Rejected-Finance | L3 | Rejected-Finance DUE TO HIGHER BID | |
| 4 | L4₹28.2 L+₹2.7 L (10.7%)Rejected-Finance | L4 | Rejected-Finance DUE TO HIGHER BID | |
| 5 | L5₹28.3 L+₹2.8 L (11.2%)Rejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L5 | Rejected-Finance DUE TO HIGHER BID |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Jan 2023, 6:00 pmClosed
GE (WEST) FEROZEPUR CANTT
GE (WEST) FEROZEPUR CANTT
REPAIR AND MAINT OF WATER PIPELINE AND RECTIFICATION OF LEAKAGE IN WATER SUPPLY LINE UNDER AOR OF GE (WEST) FEROZEPUR CANTT
2022_MES_570053_1
802022/GE-72/E8
Open Tender
Civil Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST) FEROZEPUR CANTT
₹60,000
Yes
15 Feb 2023
30 Dec 2022
21 Jan 2023
30 Dec 2022
19 Jan 2023
13 Jan 2023
Amount
Excavation in trenches not exc 1.5 metre wide and not exceeding 1.5 metre deep in soft / loose soil for laying of pipe line or cable etc. n. exc 10 sqm on plan and getting out complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified.
Removal of surplus excavated soil to a distance of 50m and depositing where directed at a point not exc 1.50m above ground level complete all as specified.
Taking out cast iron water mains from trenches, of size 200mm bore (including all fitting) with spigot and socketed ends and lead joints including burnig out joints and recovering lead for reuse after cleaning or replacement of unserviceable tubing complete all as specified and directed.complete all as specified. Note:- Earth work shall be measured and paid for separately under respctive items.
Taking out cast iron water mains from trenches, of size 150mm bore (including all fitting) with spigot and socketed ends and lead joints including burnig out joints and recovering lead for reuse after cleaning or replacement of unserviceable tubing complete all as specified and directed.complete all as specified. Note:- Earth work will be measured and paid for separately under respctive items.
All as per Srl item No.4 here -in - before but of size 100 mm bore.
All as per Srl item No.4 here -in - before but of size 80 mm bore.
Taking up or down from Over head Tanks/ Walls existing 200 mm bore CI (water mains) including all fittings with flanged ends including disconnecting pipe and fittings complete all as specified. Note:- Earth work will be measured and paid for separately under respctive items.
Taking up or down from Over head Tanks/ Walls existing 150 mm bore CI (water mains) including all fittings with flanged ends including disconnecting pipe and fittings complete all as specified. Note:- Earth work will be measured and paid for separately under respctive items.
Taking up or down existing 100 mm bore Galvanised Iron Steel water tubing and connections from trenches / walls / ceiling under floor for reuse after cleaning or replacement of unserviceable tubing complete all as specified. Note:- Earth work will be measured and paid for separately under respctive items.
All as per Srl item No.08 here -in - before but of size 80 mm bore.
All as per Srl item No.08 here -in - before but of size 40 or 50 mm bore.
All as per Srl item No.08 here -in - before but of size 25 mm bore.
All as per Srl item No. 08 here -in - before but of size 20 mm bore.
All as per Srl item No.08 here -in - before but of size 15 mm bore.
S&F in replacement of Sluice valve PN-1.6 with steel spindle and both ends flanged of 200 mm bore, conforming to BIS 14846 complete all as specified.
S&F in replacement of Sluice valve PN-1.6 with steel spindle and both ends flanged of 150 mm bore, conforming to BIS 14846 complete all as specified.
S&F in replacemetn of Sluice valve PN-1.6 with steel spindle and both ends flanged of 100 mm bore, conforming to BIS 14846 complete all as specified.
S&F in replacement of Non Return valve R/Flap FL and both ends flanged of 150 mm bore, conforming to BIS 5312 complete all as specified.
M & L for valve pit of size 120cm x 120cm x 120cm in brick masonry for sluce valves constructed completely with 3.15 MM thick MS sheet cover angle iron frame and locking arrangement including earth work PCC plastering and painting etc suitable for 150 MM dia and 200 MM dia.
M & L for valve pit of size 90cm x90cm x 90cm in brick masonry for sluce valves constructed completely with 3.15 MM thick MS sheet cover angle iron frame and locking arrangement including earth work PCC plastering and painting etc suitable for 150 MM dia and 200 MM dia.
Cleaning of valve pits of any size upto 1.20 x 1.20 mtrs x 1.20 mtr deep by taking out of all mud /earth etc including cleaning/greashing/oiling of sluice valves / Gate valves and painting the Valves and pit cover etc.
Dismantling existing gun metal gate valve of 50 mm bore size complete all as specified.
Dismantling existing gun metal gate valve of 40mm bore size complete all as specified.
Dismantling existing gun metal gate valve of 15/20/25 mm bore size complete all as specified.
M & L in replacemetn of CI Pipe 200 mm bore with spigot and socket ends centrifugally cast. Class A, in any length laid in trenches. Make :- Electrosteel/ Kesuram/ Jindal/TATA Metaliks/ BST.Note:- Earth work will be measured and paid for separately under respctive item.
M & L in replacemetn of CI Pipe 150 mm bore with spigot and socket ends centrifugally cast. Class A, in any length laid in trenches. Make :- Electrosteel/ Kesuram/ Jindal/TATA Metaliks/ BST.Note:- Earth work will be measured and paid for separately under respctive item.
All as per Srl. Item No.23 here - in - before but of size 100 mm bore.
All as per Srl. Item No.23 here - in - before but of size 80 mm bore.
M & L in replacement and fixing on wall/Over head tanks for cast iron pipes 200 mm bore with flanged ends class "B"in any length complete including rubber gasket, nuts, bolts and testing complete all as specified Make :Electrosteel/ Kesuram/ Jindal/TATA Metaliks/ BST Note:- Earth work will be measured and paid for separately under respctive item.
M & L in replacement and fixing on wall/Over head tanks for cast iron pipes 150 mm bore with flanged ends class "B"in any length complete including rubber gasket, nuts, bolts and testing complete all as specified MElectrosteel/ Kesuram/ Jindal/TATA Metaliks/ BST Note:- Earth work will be measured and paid for separately under respctive item.
M & L in replacement of Galvanised iron steel tubing 100 mm bore medium grade with all fittings duly laid in trenches complete all as specified. Make :- Jindal/ Parkash Tube/TATA /BST
All as per Srl Item No. 27 here-in - before but 80 mm bore.
All as per Srl Item No.27 here-in - before but 50 mm bore.
All as per Srl Item No.27 here-in - before but 40 mm bore.
All as per Srl Item No.27 here-in - before but 25 mm bore.
All as per Srl Item No.27 here-in - before but 20 mm bore.
M & L in replacement of Galvanised iron steel tubing 15 mm bore medium grade with all fittings fixed complete to wall and celiling or laid in floor complete all as specified. Make :- Jindal/ Parkash Tube/TATA /BST
M & L for Cast iron specials, ISI marked such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing,decreasing or double socket etc.) Tee piece single branch."Y" junction,double branch,cross(all sockets or socket and spigot collars,caps and plugs upto 300 mm bore.
M & L for Cast iron specials, ISI marked such as bendsTapers,Tee pieces (Single & double branch) any type and angle / radius and straight connecting pieces but all end flanged upto 300 mm bore.
Detecting leakage of water supply pipe lines of Cast iron of size 200mm bore from any location, any depth and repairing by providing jointing material lead, lead wool , flanged, clamps, nuts, washers & bolts etc. complete all as directed and specified including Earth work etc.
Detecting leakage of water supply pipe lines of Cast iron of size 150mm bore from any location, any depth and repairing by providing jointing material lead, lead wool , flanged, clamps, nuts, washers & bolts etc. complete all as directed and specified including Earth work etc.
All as per Srl item No.42 here -in - before but 100 mm bore
All as per Srl item No.42 here -in - before but 80 mm bore
Detecting leakage of water supply pipe lines of Galvanised iron of size 100 mm bore from any location, any depth and repairing by providing jointing material,"D" joints, union, clamps, nuts, washers & bolts and including any GI fittings etc. complete all as directed and specified including earth work etc.
All as per Srl item No.45 here -in - before but 80 mm bore
All as per Srl item No.45 here -in - before but 40/ 50 mm bore
All as per Srl item No.45 here -in - before but 20/ 25 mm bore
S & F Stop Valve of Cast Copper alloy , screwed down, high pressure with crutch or butterfly handle, screwed both ends suitable for 15 mm bore iron pipe fixed complete all as specified and directed by Engr - in -Charge. Make :- BIR / Leader / Zoloto
S & F Gun metal, globe or gate valves,with iron wheel head, screwed both ends suitable for 20 mm bore iron pipe and fixed complete all as specified. Make :- L&T/ Kirloskar / Leader / Zoloto
S & F Gun metal, globe or gate valves,with iron wheel head, screwed both ends suitable for 25 mm bore iron pipe and fixed complete all as specified. Make :- L&T/ Kirloskar / Leader / Zoloto
S & F Gun metal, globe or gate valves,with iron wheel head, screwed both ends suitable for 40 mm bore iron pipe and fixed complete all as specified. Make :- L&T/ Kirloskar / Leader / Zoloto
S & F Gun metal, globe or gate valves,with iron wheel head, screwed both ends suitable for 50 mm bore iron pipe and fixed complete all as specified. Make :- L&T/ Kirloskar / Leader / Zoloto
Repair to Sluice Valve of any size for leakages by filling of gland, replacing rusted nuts / bolts and required lathe work sheets, spindle and gland flange or any repairs/replacement required for smooth funtioning etc. complete all as specified and directed by Engr -in -Charge.
Cutting of DI/CI/GI pipe of size dia 200/150/100/80 mm & to provide the connection in any size dia pipe.
Colour code painting of supply mains pipe line, raising main pipe line,overflow pipe,washout pipe appling two coats anti rust paint over a coat of red oxide primere complete all as speificed and directed.
M & L for lead wool joints suitable for 80mm to 200mm bore CI pipe including burnig out / taking out the old unsv joint complete all as specified and directed.
Collection of raw water sample in sterilised sampling bottles and testiong from NABL accrediated lab and submission of test report in duplicate. Following parameters reqd to be check(pH,TDS,Turbity,Alkalinity,Acidity,Total Hardness as CaCo3, Calcium, Magnesium, Chloride, Sulphate, Iron, fluoride, Nitrate, Nitrite, Sodium, Potassium) Note: Transportion Charges for collecting samples and further submission to NABL Accredited lab is included in quoted rate.
S&F in replacement 150mm dia cast iron double orifice Air Release Valve complete with fixing on the delevery pipe before NRV complete all as specified and directed.
M/s Sanjiv Kumar
M/S Pee Kay Builders
B.L. Chaudhri and Co.
S S BUILDERS
Karan Engineers
Manjeet Singh Contractor
Kissan contractor and engg works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .