| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.7 LAccepted-AOC D 3 195 CHITRAKOOT NAGAR AJMER ROAD JAIPUR JAIPUR RAJASTHAN 302021 | JAIPUR | RAJASTHAN | 302021 | L-1 | Accepted-AOC Approved by competent authority | |
| 2 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹26.4 L
EMD Value
₹52,713
Closing Date
24 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(E), BSNL, ED-I, Jaipur
Type-IV, Qtr No. R-2 and R-4, P and T Colony, Bhagat Singh Marg, C-Scheme, Jaipur
Rate contract for redeployment,providing associated and misc. works for Microprocessor based high precesion type AC package units with Air cooled condensers at Various TE Bldgs under BSNL, Rajasthan circle.
2021_BSNL_72091_1
75/20-21/BSNL/ED-I/JP/SE/20
Open Tender
Electrical Works
Item Rate
180 days
Jaipur
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
A.O. (Cash), O/o PGMTD, BSNL, JAIPUR
₹52,713
13 Apr 2021
3 Mar 2021
26 Mar 2021
3 Mar 2021
24 Mar 2021
3 Mar 2021
90 days
Amount
Supply and installation of fresh air package suitable up to 600 CFM provided with fine filters for outside air having efficiency of 99% for dust particles down to 5 micron mounted on a suitable frame along with necessary dry fabric synthetic type cleanable pre fillters, necessary sheet metal louvers/grills with volume control dampers minor civil work etc as per specification necessary 1450 rpm booster/exhaust fans suitable for operation on 230+/-5% volts single phase 50Hz. supply shall be provided to overcome the static pressure of fine filters as required ( for PAC configuration as required)
Supplying, installing, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, support as per approved drawing and specifications of following sheet thickness complete as required.
(i) Thickness 0.63 mm sheet
(ii) Thickness 0.80 mm sheet
(iii) Thickness 1.00 mm sheet
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
SITC of GI Volume Control Damper complete with neoprene rubber gaskets nuts , bolts, screws linkages, flanges etc. as per specifications.
Providing, Making & Fixing of flexible Double Layer canvas connection complete as required.
SITC of sandwiched insulation with 25 mm thick resin bonded glass wool covered with 2 numbers of ISI marked exterior grade/grade-I MDF particle board of 12mm thick i/c one coat of primer and two coat of synthetic enamel paint including providing frame work of size not exceeding 1200mmx 600mm with not less than 30mmx25mm x30mm U-shaped 18 SWG CRCA MS sheet channel with minor civil works etc complete as required
SITC of duct cladding by 25 mm thick resin bonded glass wool insulation wrapped in hessian faced vapor barrier covered with 24 gage GI sheet for supply air distribution ducts complete as required
SITC of return air boxing (in AC area ) by means of ISI marked exterior grade/grade -I MDF particle board of 12 mm thickness, internal side exposed to return air cladded with 24 gauge GI sheet and outer surface/ duly painted with one coat of primer and two coat of synthetic enamel paint i/c P/F frame work of size not exceeding 1200 mm x 600 mm with not less than 30x25x30mm U shaped channel of 18 SWG CRCA MS Sheet including minor civil works etc. as per specification as required
SITC wall insulation with 25 mm thick resin bonded glass wool covered with ISI marked exterior grade MDF particle board of 12 mm thick including pdg. Frame work of size not exceeding 1200 mm x 600 mm with not less than 30x25x30mm U shaped channel of CRC sheet 18 SWG CRCA MS Sheet and outer surface duly painted with one coat of primer and two coat of synthetic enamel paint including minor civil works etc. as per specification as required
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Dismantle and ITC of existing Announciator control alarm (audio/visual) system at existing M.V. switch panel with repairing/replacement of necessary contactor, fuses, relays, thermostats,humidistat, sensing devices,wiring etc. for A) Audio visual indication incase of following i) Switch room temp. higher than-pre set value 23c+/-3oC ii) Switch room RH higher & lower than preset value 30%-70% iii) fire Alarm iv) Potential free contacts for extension of alarm for remote monitoring v) FA fan failure vi) Fire damper Closer B) INTERLOCKS Interlocking for tripping Main MCCB of panel in case of fire alarm.
SITC of PVC insulated PVC sheathed aluminum conductor armoured cable of following sizes on the existing MS tray /walls with saddles/PVC of cables with glands etc. as required
i) 4 x 10Sqmm (for Pkg.)
SITC of following PVC insulated PVC sheathed copper conductor armoured cable for control wiring on the existing MS tray / walls with saddles/PVC thread/cable tie, screws etc. I/c end termination of cables with glands etc as required.
i) 4 x1.5sqmm
SITC of Plumbing work for drainage requirement with following size pipes i/c reducer, elbows, tees, unions, bends, sockets, flanges etc. for making water line connection for various package Units of system etc. complete as required.
40 mm CPVC Pipe
20 mm CPVC Pipe
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts& nuts, painting suspenders etc as required.
i) 100mm width x 50mm x 1.6mm thickness
i) 150mm width x 50mm x 1.6mm thickness
i) 200mm width x 50mm x 1.6mm thickness
Providing and Fixing 25mm X 5mm G.I. strip on surface or in recess for connections etc. as required
SITC of 06 mm thick (ISI marked) rubber matting at the reqd locations etc complete as reqd.
Painting of existing ducting with two coats of silver paint complete after due cleaning and rubbing of the duct surface etc as reqd.
Pdg. Making wall opening to increase the return air area complete I/c with finishing the same and shifting the debris / malba etc. to ground floor as directed by E-IN-C
Providing & Making Aluminum frame with 80MMX38MM 16 gauge Aluminum member suitable for powder coated grills etc. complete as required
S/F of Wall Mount Wireless Temperature and Humidity Display Meter to display the outdoor and indoor temperature (Fahrenheit or Celsius) and Humidity etc complete a reqd.
Dismantling & removing the existing laid old power/control cables of booster fans, old package units, condenser units, heaters/pre-heaters system, humidification etc. complete by unscrewing/cutting from the related M.S. racks/tray as required, lowering down the same from different floor to ground floor & shifting the same to the place inside the exchange premises as directed by Eng.-in-charge.
Dismantling / removing the existing fitted package A.C. units with related condensers & accessories like canvas, damper & lowering down the same from different floor and terrace to ground floor along with shifting the same to the place inside the exchange premises as directed by Eng.-in-charge.
Dismantling / removing the existing fitted package A.C. units with related condensers & accessories like canvas, damper & lowering down the condensor and shifting from one room to other room (Same Floor) to the place inside the exchange premises as directed by Eng.-in-charge.
Recovering the existing laid refrigerant piping of old defective / worn out Hot gas & cold gas of different sizes complete by cutting/unscrewing /opening etc. fitted in between the package unit & condenser unit lowering down the same from different floor to ground floor and shifting the same to the place inside the exchange premises/keeping in safe custody as directed by Eng.-in-charge.
Dismantling the existing fitted old MS Racks (of cables /gas line pipes ) viz. angle , square pipe, bar, hangers etc. along with shifting the same from different floor to ground floor to the place inside the Exchange premises as directed by Engr.- in-charge (One AC Plant Room = 01Job)
Dismantling / removing the existing laid old worn out defective condensate drain piping, lowering down the same from different floor to ground floor i/c shifting the same to place inside the exchange premises as directed by E-in-charge.
Dismantling the existing old ducts( all different shapes included) of package units along with fine filters & plenum complete by unscrewing, opening the flanges, supports,hangers, lowering down the same from different floor to ground floor i/c shifting the same to the place inside the exchange premises as directed by Eng.-in-charge.
Transportation of the existing old dismantled package A.C. units with related condensers & all other accessories like Cu-piping, Electric Cable , damper etc. from the existing TE Bldg where these pkg units were originally installed in Rajasthan to any other TE Bldg. in Rajasthan where to be redeployed and shifting the same to the new place inside the AC Plant Room at exchange premises as directed by Eng.-in-charge.
Distance up to 250 Km
Distance beyond 250 Km
Installation, Testing and Commissioning of above shifted 7 TR HPAC Package indoor and outdoor units on existing frame, pressure testing, i/c Trial Run or Performance Testing of package Units as per norms etc complete as reqd.
7 TR (Sensible) High Precision AC Package unit
a) The hot gas refrigerant line shall be insulated inside conditioned area with high quality insulating material, nothing extra shall be paid on this account
b) The MS Structure for outdoor units shall be installed on minimum size 300mm x 300mm x 300mm PCC block with 25mmx25mmx3mm angle iron on edges, nothing extra shall be paid on this account. However, the M.S. Structure for outdoor unit / Indoor unit (if required) shall be paid extra .
c) The each outdoor and indoor unit shall be installed on 12 nos. AVM pads (Rubber pad), nothing extra shall be paid on this account.
Supplying and Charging of the Referigerant Gas i/c pressure testing etc. Complete as required.
(1) R-407 or same as per Originally supplied with PKG Units (Excluding R-22)
Supply & fixing of the following sizes 18 gauge ( 1.2 mm) copper referigerant piping on existing MS perforated tray etc. complete as reqd
Size 1-1/8" Single Run
Size 7/8" Single Run
Size 5/8" Single Run
Laying / Fixing of following size of existing recovered copper referigerant piping on the existing MS perforated Tray (wherever required) etc complete as reqd
Size 1-1/8" Single Run
Size 7/8" Single Run
Size 5/8" Single Run
Supplying and laying of following sizes of PVC insulated PVC Sheathed copper conductor armoured cable of 1.1 KV grade conforming to relevent I.S. on wall/ existing trench/ existing MS perforated tray (with saddles) i/c interconnections, end termination, gland etc. complete as reqd. (As per CPWD specifications).
4 x 2.5 sqmm
Providing MS structure for outdoor / Indoor units made out of solid channels / angles/flat i/c cutting, welding , painting etc as reqd.
ITC of following old recovered items complete with fixing/ laying as reqd.
i) 100mm width x 50mm x 1.6mm thickness MS cable Tray
ii) 150mm width x 50mm x 1.6mm thickness MS cable Tray
iii) 40 mm G.I.Pipe (Medium Class)
iv) 25 mm G.I.Pipe (Medium Class)
v) 4 x 10 Sqmm Alu. armoured Cable (for Pkg.)
vi) 4 x 1.5/ 4 x 2.5 Sqmm sqmm Copper armoured Cable
vii) Existing Duct / Fire Dampers in supply air main ducts / branch ducts complete as required
viii) 25 mm x 5 mm thick G.I. strip for loop earthing on cable tray / wall etc as required
Dismantling the existing 2 Nos fresh air fans from Engine room at TE bldg Rajgarh and ITC of these fans for natural cooling system at Tax switch room E10B alwar including making opeining, finishing,complete as required as directed by Eng.-in-charge.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .