Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.3 LAccepted-AOC BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L1 | Accepted-AOC L1 | |
| 2 | L2₹46.4 L+₹3.8 L (8.87%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹47.8 L+₹5.3 L (12.4%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹48.9 L+₹6.3 L (14.9%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹49.2 L+₹6.6 L (15.5%)Rejected-Finance 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
22 Feb 2024, 6:00 pmClosed
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
PROVISION OF INDUSTRIAL DEHUMIDIFIER AND ALLIED WORKS AT BLDG NO T-10 DAL STORE AT BV YARD UNDER AGE EM-I AT GE MINNIE BAY PORT BLAIR
2024_MES_638785_1
8358/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Minniebay Port Blair
As per tender documents
10 documents required · 10 mandatory
₹500
GE Minniebay
₹87,000
Yes
20 Apr 2024
23 Jan 2024
24 Feb 2024
24 Jan 2024
22 Feb 2024
9 Feb 2024
Amount
Supply, installation, testing and commissioning of of Desiccant type dehumidifier of capacity 600 CMH with input power supply 415 V, Three phase, 50 Hz, equipped with microprocessor based control system having LED display indicating the status of input, Humidistat with digital display, made out of pre-coated MS sheet , the dehumidifier is having totally self contained eco dry rotor/desiccant rotor, process & reactivation air flow sectors insulated with aluminium foils, unique PTFE bonded bulb seal design to minimize air leakages, the desiccant rotor is made of fluted honeycomb type with stainless steel perimeter flange to incorporate robust internal structure required for industrial quality, durability and easy serviceability and also to extend media and seal life. The desiccant rotor is non flammable and its media shall have high performance metal silicates synthesized in situ, differential air pressure switch to control reactivation air flow and indicating clogging of filters, High temperature thermostat cutout to economize the power consumption, additional cooling thermostat as a safety measure, electrical interlocking of fan motor, heaters and rotor drive as a safety measure, PTFE bonded silicon bulb seal design to minimize air leakage, dehumidifier shall have an option to control reactivation temperature, system parameters complete all as specified and as directed by Engineer in Charge. Model : FFB600 of Make : Bry-Air or equivalent model of make Drystar India Pvt Ltd / Salleria Solutions / Munters / Seibu Giken DST / equivalent approved make of HQ CESC Pune / GE confirming relevant IS provisions.
Note: (i) The quoted rate deemed to be inclusive of necessary foundation work with angle iron frame work all as per OEM recommendation, flexible rubber hose pipes along with perforated end caps for bird proof for connecting reactive air inlet and outlet line up to room outside by core cutting in any type of wall & control cable from equipment to MCB DB for full functionality of machinery.(ii) Manufacturer type test certificates/ test reports for equipments shall be submitted by contractor before claiming payment.(iii) The quoted rate deemed to inclusive of service visit once in three months during defect liability period and contractor shall submit FDR of amount 2% on completion cost of subject item before completion/processing final bill.
S&F sheet metal enclosure along with single MCB TPN 32 Amps, 'C' curve, breaking capacity 10 KA complete all as specified and as directed by Engineer in Charge.
Supply and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cable 3.5 Core 50 Sqmm, XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade complete all as specified and as directed by Engineer-in-Charge. Note: (i) The rates shall be inclusive of Cable lugs at both ends of cable . (ii) Excavation earth, return and re filling shall be measured and paid separately.
Excavation in trenches any type of soil (soft/loose/hard/dense) not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, pipe, laying of cable etc not exc 10 Sqmtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-Charge
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and as directed by Engineer-in -charge.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed by Engineer-in -charge.
Supply & Laying DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm polyethylene including coupler & Bend with smooth internal and corrugated external surface for non pressure under ground cable complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully existing aluminium point wiring (light, fan , socket or power) complete fittings fixture such as switches Ceiling roses, pendents,regulators, sockets etc to be measured separately)unscrewing from Board/outlet boxes, fittings & fixtures such as switches, sockets, ceiling rose lamp holder tube/ceiling fitting, bulk head fittings, tube lights & regulator etc and making good disturbed surfaces of walls, floors etc complete all as specified and as directed by Engineer-in-Charge.
M&L for point wiring with two run of PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm (FRLSH), PVC conduit medium grade/PVC casing capping and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered GI metal flush box and drawing one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable (FRLSH) as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge. Note: The quoted rate inclusive for the following :- (a) Modular cover plate with frame of any module complete. (b) Proper colour coding is to be followed as per IS Specification. (c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing capping as per site requirement. In ceiling Portion surface conduit wiring shall be carried out.)
One light point controlled by one one way switch.
One ceiling fan/exhaust fan point controlled by one switch.
One 3 pin socket outlet 5 Amps on the same board with other switches
One 3 pin socket outlet 5 Amps independent.
All as per srl item No.9.00 above here-in-before but for 15/16 Amps socket out let independent with 2.5 sqmm copper conductor complete all as specified and as directed.
M & L for sub main wiring with four single core PVC insulated unsheathed multistranded copper conductor cable of size 10 sqmm (FRLSH) and one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 10 Sqmm (FRLSH) as earth lead in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing capping of suitable size and making good the disturbed wall surfaces to match with existing specification including taking down unserviceable sub main wiring complete all as specified and as directed. Note : (i) Five runs of cables and one run of PVC conduit/PVC casing and capping will be measured as one unit length.
M & L for sub main wiring with four single core PVC insulated unsheathed multistranded copper conductor cable of size 6 sqmm (FRLSH) and one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 6 Sqmm (FRLSH) as earth lead in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing capping of suitable size and making good the disturbed wall surfaces to match with existing specification including taking down unserviceable sub main wiring complete all as specified and as directed. Note : (i) Five runs of cables and one run of PVC conduit/PVC casing and capping will be measured as one unit length.
M & L for sub main wiring with two single core PVC insulated unsheathed multistranded copper conductor cable of size 6 sqmm (FRLSH) and one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 6 Sqmm (FRLSH) as earth lead in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing capping of suitable size and making good the disturbed wall surfaces to match with existing specification including taking down unserviceable sub main wiring complete all as specified and as directed. Note : (i) three runs of cables and one run of PVC conduit/PVC casing and capping will be measured as one unit length.
All as per item No 17.00 here-in-before but with 1.5 sqmm cable for building security light complete all as specified and as directed. Note for items No 15 to 18: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing capping of suitable size as per site requirement.
Supply & fixing modular switch one way, 6 Amps, 1 module, 240 volts complete all as specified and as directed
Supply & fixing modular switch one way, 16 Amps, 1 module, 240 volts complete all as specified and as directed.
Supply & fixing modular socket, 2/3 pin, 6 amps, 2 module complete all as specified and as directed.
Supply & fixing modular socket, 2/3 pin, 6/16 amps, 2 module complete all as specified and as directed.
Supply & fixing ceiling Rose, 3 terminal polycarbonate isolated body complete all as specified and as directed.
Supply & fixing LED luminaries 600mm X 600mm, 40 watt, 220V AC, 100 lm/watt, 6500K, IP 20, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. Note: Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply & fixing BLDC ceiling fan 1200mm sweep with blades, suitable remote electronic regulator as per OEM design, down rods and connected accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM, 5 star rated of wattage less than 28 watts, equipped with brushless direct current motor (BLDC) including provision of cable from ceiling rose/connector to fan complete all as specified and as directed.
Supply & fixing Wall mounted fan 400mm sweep with blades, mounting accessories kit, blade guard set, guard ring, AC 230V complete all as specified and as directed.
Supply and fixing MCCB DB VTPN 4 way IP-54, IK-09 made of sheet steel phosphatised, powder painted with copper bus bar 200A, neutral link, earth bar and Din rail 415 Volts with double door, suitable for MCCB 4 Pole 100-160 Amps as incomer and MCB Single Pole as outgoing complete all as specified and as directed.
Supply & fixing MCB DB's TPN 4 way, IP-54, IK-09 double door, sheet metal enclosure, 415V, 200 amps rated copper busbar complete all as specified and as directed.
Supply & fixing MCB DB's SPN 8 way, IP-54, IK-09 double door, sheet metal enclosure, 240V, 200 amps rated copper busbar complete all as specified and as directed. Note for item srl No 27.00 to 29.00 : (i) MCCB and MCB will measured and paid separately. (ii) Cost for concealed the DBs on wall including making good disturbed surfaces with existing colour shall be deemed to be included in the quoted rate.
Supply & fixing MCCB 160 Amps, thermal adjustable, 25 KA , AC 415 Volts, four pole complete all as specified and as directed.
Supply & fixing MCB TPN C curve, 415 volts, 40 to 100 amps, with rupturing capacity 10 KA, complete all as specified and as directed.
Supply & fixing MCB TPN, C curve, 415 volts, 16 to 32 amps with rupturing capacity 10 KA, complete all as specified and as directed.
Supply & fixing MCB SPN C curve ,240 volts, 40 to 63 amps, with rupturing capacity 10 KA, complete all as specified and as directed.
Supply & fixing MCB single pole 240 volts, 6 to 32 amps, with rupturing capacity 10 KA, complete all as specified and as directed.
M&L for earthling complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised iron strip 32 x 6 mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth strip and GI protection pipe up to 7.5mtr length shall be deemed to be included in the rate quoted for this item (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit, test point complete
S & F Aluminium flat iron work in, wind ties screwed as directed, including all necessary drilling, bolting or riveting etc and similar work complete all as specified and as directed by Engr-in-Charge
S & F in repairs anodized aluminium grid work 605 x 605 mm with using 36.5mmx23.5mmx1.5mm thick main tee, 23.5 x23.5mmx1.28mm cross tee and 25x25x1.5mm angles fixed to perimeter of wall for false ceiling including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified & directed all as specified & directed
M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid / inserted to timber/ GI / Aluminium framework with screws complete all as specified and as directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished fair and even without using extra cement.
M & L for preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed by Engr-in-Charge
M & L for preparation of old distempered surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed by Engr-in-Charge.
M & L for preparation of old steel surfaces exc 10cm width and girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engr-in-Charge.
S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 MPA as in roof covering fixed with self tapping screws as specified and as per manufacturers instructions complete all as specified and directed
S&F prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 MPA as in ridges fixed with self tapping screws as specified and as per manufacturers instructions complete all as specified and directed.
S&F Anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engr-in-Charge.
S & F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as Peg stays 150mm long (1 No), hinges type B-21,100 long (2 No) suitable handle (1 no.) complete all as specified and as directed by Engr-in-Charge. Note : labour Cost of fixing sheet glass and wire cloth included in this quoted rate and material shall deemed to be paid under "Supply only" items.
Supply only 4 mm thick sheet glass ordinary quality and glazing with oil putty in squares exceeding 0.5 Sq.m in each pane complete all as specified and as directed by Engr-in-Charge.
Taking down chowkats & frames exc. 1.50 sqm but not exc. 4.00 sqm with shutters and grills ( if fixed) without taking off shutter the frame including iron mongries and complete all as speicifed and as directed by Engr-in-Charge.
Supply only Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by Engr-in-Charge
SKY GROUP
Prasur Electricals & Engineering Co.
DHAKSHNA MOORTHY AND SON
Ravi Enterprises
M/s Karbhagam Sales Agency
Chandra Construction Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .