GE I R AND D GIRINAGAR PUNE 411025
GE I R AND D GIRINAGAR PUNE 411025
REPAIR REPLACEMENT OF ELECTRIC FITTINGS AND FIXTURES DB WIRING SUB MAIN WIRING EARTHING ETC REAPIR OVERHAULING OF CEILING FANS SUMMER COOLING APPLIANCES AT CERTAIN BLDG OF TECH AND RESI AREA AT R AND D E ENGRS DIGHI AND OCRI AND PROOF RANGE AT KIRKEE
2020_MES_397900_2
GE I R AND D GNR TOKEN 40 OF 2020 21
Open Tender
Civil Works
Works
180 days
GE I R AND D GIRINAGAR PUNE 411025
REPAIR REPLACEMENT OF ELECTRIC FITTINGS AND FIXTURES DB WIRING SUB MAIN WIRING EARTHING ETC REAPIR OVERHAULING OF CEILING FANS SUMMER COOLING APPLIANCES AT CERTAIN BLDG OF TECH AND RESI AREA AT R AND D E ENGRS DIGHI AND OCRI AND PROOF RANGE AT KIRKEE
6 documents required · 6 mandatory
₹500
Yes
GE I R AND D GIRINAGAR PUNE 411025
₹46,000
Yes
11 Jan 2021
24 Dec 2020
9 Jan 2021
24 Dec 2020
8 Jan 2021
25 Dec 2020
24 Dec 2020 - 25 Dec 2020
Amount
Taking down carefully Copper aluminium point wiring light, Fan, socket or power complete including fixture & fitting such as switches, sockets or power socket complete fitting bracket holder, boards, and making good disturbed surfaces of wall and ceiling etc.
Taking down carefully unserviceable sub main wiring including conduit/casing patti etc.
Taking down unserviceable DBs any type / size carefully disconnecting and making good disturbed surfaces complete all as directed.
Taking down unserviceable MCB SP/SPN/Isolator of any rating & size.
M & L for Point wiring complete with 1.5 Sqmm single core unsheathed PVC insulated 1100 V, FR grade with multistranded copper conductor ISI marked drawn through in existing concealed / surface PVC/Steel conduit and accessories and existging MS pressed steel terminal box and replace laminated sheet 3mm thick for mounting of switches, socket regulator etc including 1.5 Sqmm PVC insulated unsheathed cable multistranded copper conductor and connecting to earth dolly for light, Fan, Plug and bell all as directed and specified by Engr-in-charge. (a) One light point controlled by one 5 Amps one way switch.
(b) One light point controlled by two Two way switch
© One ceiling Fan, Exhaust Fan point controlled by one 5 Amps switch.
(d) One bell/buzzer point controlled by one bell push button on independent board.
(e) One 3 Pin 6 Amps socket point on the independent board.
(f) One 3 pin 6 Amp socket point on the same board with other switch.
All as per above item No-5 but with 2.5 Sqmm cable for 15 Amp switch socket out let point on independent board including 1.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor all as directed and specified by Engr-in-charge.
M &L for Point wiring complete with 1.5 Sqmm single core unsheathed PVC insulated 1100 V, FR grade with multistranded copper conductor ISI marked drawn through and including PVC casing & caping fixed on surface wall/ceiling and including pressed steel terminal box, grouted in wall and the 3mm thick terminated sheet top cover for mounting of switches, sockets regulators etc including 1.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor and connecting to earth dolly for light, fan, plug and bell all as directed and specified by Engr-in-charge. (a) One light point controlled by one 5 Amps one way switch.
(b) One light point controlled by two way switch
(c) One ceiling Fan, Exhaust Fan point controlled by one 5 Amps switch.
(d ) One bell/buzzer point controlled by one bell push button on independent board.
(e) One 3 Pin 6 Amps socket point on the independent board.
(f) One 3 pin 6 Amp socket point on the same board with other switch.
All as per above item No-7 but with 4 Sqmm cable for 15 Amp switch socket out let point on independent board including 2.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor all as directed and specified by Engr-in-charge.
M&L for point wiring with FR PVC insulated sheathed copper conducter of size 1.5 Sqmm (nominal area) with multistranded copper conductor drawn through in PVC conduit including concealing conduit in wall/floors etc. medium grade of suitable size with all fittings and accessories including cutting chases in wall for fixing rigid PVC conduit and MS galvanised shunk type box covered with laminated PVC sheet fixed with brass screw of suitable size for housing/mounting of switches/sockets including 1.5 Sqmm FR PVC insulated sheathed multistandard copper conductor for one light /fan contineous earth wire connected to common earth dolly for one light/fan point control by one switch and making good the distributed surfacess completely matched and finished with existing surfacess including painting of walls etc. all as specified and as directed by Engr-in-Charge. (a) One light point controlled by one 6 Amps one way switch
(b) One ceiling Fan, Exhaust Fan point controlled by one 6 Amps switch.
(c ) One bell/buzzer point controlled by one bell push button on independent.
(d) One light point controlled by 2 Nos ,6 amps Two way switch.
(e) One 3 pin socket out let 6 Amp point on independent board
(f) One 3 Pin socket out let 6 Amp point on the same board with other switch.
All as per above item No-9 but with 4 Sqmm cable for 16 Amps switch sockets out let point on independent board including 2.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor.
M&L for Rigid non-metallic PVC conduit 25mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
M&L for Rigid non-metallic PVC Junction boxes (1 to 4 way)
M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall all as directed by Eng-in-charge.
Supply and fixing switch piano flush button type , singlepole one way 5 Amps complete all as specified and directed by Eng-in-charge..
Supply and fixing switch piano flush button type , single pole two way 5 Amps complete all as specified and directed by Eng-in-charge..
Supply and fixing Bell push flush type SP 5 Amps.
Supply and fixing switch socket combination out let 5 pin 6 Amps flush type.
Supply and fixing switch socket out let 2 in 1, 3 pin 5 and 16 Amps flush type Universal.
Supply and fixing Bell push modular type SP 6 Amps.
Supply and fixing socket combination outlet 2/3 pin 6 Amps modular type.
Supply and fixing switch socket outlet 2 / 3 pin 6 and 16 Amps 2 modular type.
S & F ceiling rose ,3 phase, PVC polycarbonate, insulated body.
Supply and fix stepped type elctronic fan regulator 240 V 50 HZ , 100Watts flush type suitable for 1200/1400mm sweep ceiling fan complete including connection and dismantling of unsv regulator all as specified and directed.
Supply and fix fan regulator electronic 2 modular type volts AC 50 HZ ,300 Watts,4step complete all as directed.
Supply and fix call bell (Ding Dong) 240 V, 50 Hz
M&L for lamp holder pendant/angle type insulated body with back plate all as directed and specified by Engineer-in-Charge.
Supply and fixing in replacement of existing unserviceable T/L batten 36/40 W on existing pole/wall with new batten for LED light fitting suitable for 18/20 watts LED tube rod, with necessary braket,clamps ,incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. Make-Bajaj Cat No BLRB-DB-118 Or eqvt make of PHILIPS/WIPRO/CG
Supply and fixing in replacement of existing unserviceable T/L fitting 20 W/Lamp holder on existing pole/wall with LED light fitting 9/10 watts with LED tube rod, ready to use pack with necessary braket,clamps ,incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. Make-Bajaj Cat No BCLSB 10 WH Or eqvt make of PHILIPS/WIPRO/CG
Supply & fixing of surface mounting round downlight LED 12 watt luminarie complete fitting with all fixing arrangement all as specified and directed by Engr-in-Charge. Make-Bajaj Cat No BGCML 12 01 WH Or eqvt make of PHILIPS/WIPRO/CG
Supply & fixing of Recessed mounting 2x2 LED luminarie 30 W white powder coated CRCA housing with LEDs seamless front fram with flat white high transmission acrylic cover complete fitting with all fixing arrangement all as specified and directed by Engr-in-Charge. Make-Bajaj Cat No BZRSQL 36W GZi WH LED Or eqvt make of PHILIPS/WIPRO/CG
Supply & fixing of Recessed/surface mounting 2x2 LED luminarie 30 W white powder coated CRCA housing with LEDs seamless front fram with flat white high transmission acrylic cover complete fitting with all fixing arrangement all as specified and directed by Engr-in-Charge. Make-Bajaj Cat No BZRSQL 30W GZ WH Or eqvt make of PHILIPS/WIPRO/CG
Supply & fixing of Recessed/surface mounting 1x4 LED luminarie 36 W complete fitting with all fixing arrangement all as specified and directed by Engr-in-Charge. Make-Bajaj Cat No BZRSLL 36W GZ1 CW Or eqvt make of PHILIPS/WIPRO/CG
Supply & fixing of LED standalon suspended sleek luminaires 20 W (1x4 ft) complete fitting with suspension of 1.5 mtr(2 Nos) is included, all fixing arrangement all as specified and directed by Engr-in-Charge. Make-Bajaj Cat No BPTXn 20W LED 4F WH Or eqvt make of PHILIPS/WIPRO/CG
Supply & fixing of LED security light fitting with pressure dia cast housing, prismatic, polycarbonate diffuser and IP65 protection with 0.6 mtr long 20/25 mm (as per manufacturer standard) dia GI Pipe in 45 degree bend shape and necessary clamping devices required at site complete all as specified and directed by Engr-in-Charge. Make-Bajaj Cat No BCLST 20W LED IV2 or eqvt make of PHILIPS/WIPRO/CG
Supply & fix LED 40 watt decorative post top lantern made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP 65 protection, resistance to impact and corrosion, glare free and better uniformity includes necessary PCC foundation for fixing of light fitting etc. all as directed and specified. Make-Bajaj Cat No BGCL 40W LED WH Or eqvt make of PHILIPS/WIPRO/CGand all as specified and directed by Eng-in-charge..
Supply & fix LED 4 watt decorative post top lantern made in die cast aluminium housing with decorative clear opal acrylic diffuse rand IP 65 protection, resistance to impact and corrosion, glare free and better uniformity includes necessary PCC foundation for fixing of light fitting etc. all as directed and specified. Make-Bajaj Cat No BGCT W4 LED WW Or eqvt make of PHILIPS/WIPRO/CG
Supply & fix LED decorative garden light inverted pyramid tripod type LED bollard with soft 30 degree light, IP 65 protection, resistance to impact and corrosion, glare free and better uniformity includes necessary PCC foundation for fixing of light fitting etc. all as directed and specified. Make-Bajaj Cat No BGBOM 650 9W LED Or eqvt make of PHILIPS/WIPRO/CG and all as specified and directed by Eng-in-charge..
Supply and fixing in replacement of existing tube rod 36/40 from existing fitting by making connection as per requirement of connection of new tube rod with old T/L fitting with LED tube rod 18/20 watts etc complete all as specifed and directed by Engineer-in-charge. Make-Bajaj Cat No BLRB 18W CW Or eqvt make of PHILIPS/WIPRO/CG
Supply and fixing in replacement of existing tube rod 4 pin 36/40 from existing fitting by making connection as per requirement of connection of new tube rod with old T/L fitting with LED tube rod 15 watts etc complete all as specifed and directed by Engineer-in-charge. Make-Bajaj Cat No PRO BLL 15W LED 2G11 Or eqvt make of PHILIPS/WIPRO/CG
S&F modular metal flush box 1/2 module for mounting modular type switches/sockets all as directed. Make : ANCHOR WOODS/ CRABTREE / L & T /LEGRAND and all as specified and directed by Eng-in-charge..
S&F modular metal flush box 3 module for mounting of modular type switches/sockets all as directed. Make : ANCHOR WOODS/ CRABTREE / L & T /LEGRAND and all as specified and directed by Eng-in-charge..
S&F modular metal flush box 4 module for mounting of modular type switches/sockets all as directed. Make : ANCHOR WOODS/ CRABTREE / L & T /LEGRAND and all as specified and directed by Eng-in-charge..
S&F modular metal flush box 6 module for mounting modular type switches/sockets all as directed. Make : ANCHOR WOODS/ CRABTREE / L & T /LEGRAND and all as specified and directed by Eng-in-charge..
S&F modular metal flush box 8 module for modular type switches/sockets all as directed. Make : ANCHOR WOODS/ CRABTREE / L & T /LEGRAND and all as specified and directed by Eng-in-charge..
Supply and fix modular White cover plate with frame, 1 module
Supply and fix modular white cover plate with frame but 2 module
Supply and fix modular white cover plate with frame but 3 module
Supply and fix modular white cover plate with frame but 4 module
Supply and fix modular white cover plate with frame but 6 module
Supply and fix modular white cover plate with frame but 8 module
S&F RCCB, DP, with earth leakage, over load and short circuit protection , 230 volts, 10 amps, with 30mA
M & L for Sub main wiring complete with 2 runs of 4 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn through existing concealed PVC/Steel conduit and including 1 run of 2.5 Sqmm PVC insulated unsheathed copper conducter with multistranded copper conductor as earth continuity. Note : Two runs of copper conducter and one run of earth copper conducter shall be measured as one length.
M & L Sub main wiring complete with 2 runs of 2.5 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn through PVC cassing and capping / PVC conduit accessories fixed on surface/wall celing etc including provision of 1 run of 1.5 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity. Note : Two runs of copper conducter and 1 runs of earth copper conducter shall be measured as one length.
M & L for Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn through existing concealed PVC/Steel conduit and including 1 run of 4 Sqmm PVC insulated unsheathed copper conducter with multistranded copper conductor as earth continuity. Note : Two runs of copper conducter and one run of earth copper conducter shall be measured as one length.
M & L Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn throughn and including PVC rigid conduit/casing capping and conduit accessories fixed on surface/wall celing etc including provision of 1 run of 4 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity. Note : Two runs of copper conducter and one run of earth copper conducter shall be measured as one length.
M & L for Sub main wiring complete with 4 runs of 6 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn through existing concealed PVC/Steel conduit including 2 runs of 4 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity. Note : Four runs of copper conducter and 2 runs of earth copper conducter shall be measured as one length. Note : Four runs of copper conducter and Two runs of earth copper conducter shall be measured as one length.
M & L Sub main wiring complete with 4 runs of 6 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn throughn and including PVC rigid conduit/PVC casing capping and conduit accessories fixed on surface/wall/ celing etc including provision of 2 runs of 4 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity. Note : Four runs of copper conducter and Two runs of earth copper conducter shall be measured as one length.
Supply & fix MCCB DB VTPN 4 ways,with metal double door ,IP -43 protection suitable for MCCB as incommer and MCB as out going, 415 volt 3 phase complete with appropriate size copper bus bar and neutral link confirming to cat part no-607750 of legrand including 63 Amp capacity 4 pole MCCB, 16 kA complete including cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site i.e directed by Engr-in charge. Make : Legrand Or eqvt make of ABB/Siemens/Merlin Gerin
Supply & fix MCCB DB VTPN 8 ways,with metal double door ,IP -43 protection suitable for MCCB as incommer and MCB as out going, 415 volt 3 phase complete with appropriate size copper bus bar and neutral link confirming to cat part no-607751 of legrand including 63 Amp capacity 4 pole MCCB, 16 kA complete including cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site i.e directed by Engr-in charge. Make : Legrand Or eqvt make of ABB/Siemens/Merlin Gerin
Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 4 way with IP-43 IK-09 protection single door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification. Make : Legrand Or eqvt make of ABB/Siemens/Merlin Gerin
Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 8 way with IP-43 IK-09 protection single door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .Make : Legrand Or eqvt make of ABB/Siemens/Merlin Gerin
Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 12 way with IP-43 IK-09 protection single door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification. Make : Legrand Or eqvt make of ABB/Siemens/Merlin Gerin
S & F sheet metal enclosures DB's 2 way SPN single door suitable for 240 V complete fixed flush in wall including chases in wall for fixing DB and making good distributed wall surfaces to match with existing specification. Make : Legrand Or eqvt make of ABB/Siemens/Merlin Gerin
S & F MCB single pole (SP) 240 volt 06-32 amp for inductive load connected through cable lugs of suitable size complete all as directed and specified. Make: Legrand/ABB/Siemens/Merlin Gerin
S & F MCB double pole (DP) 240 volt 06-32 amp for inductive load connected through cable lugs of suitable size complete all as directed and specified. Make: Legrand/ABB/Siemens/Merlin Gerin
S & F MCB Tripple pole (TP) 240 volt 06-32 amp for inductive load connected through cable lugs of suitable size complete all as directed and specified. Make: Legrand/ABB/Siemens/Merlin Gerin
S & F Isolator triple pole and neutral 415 volt 40 amps for inductive load through cable lugs of suitable size complete all as specified . Make : Legrand Or eqvt make of ABB/Siemens/Merlin Gerin
S & F Isolator triple pole and neutral 415 volt 63 Amps triple pole and neutral for inductive load connected through cable lugs of suitable size complete all as specified . Make : Legrand Or eqvt make of ABB/Siemens/Merlin Gerin
M & L for galvanised steel earth earthing complete with 60 cm x 60 cm x 6 mm thick galvanised steel earth electrode and 04 mm dia galvanised earth lead wire burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to earth lead 4.0 mm dia GI wire protected by 15 mm bore light grade galvanised iron pipe and other and connected to test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron wire mesh, charcoal and common salt in alternater of 15 cm complete thickness all around the GI plate electrode complete with earth pit PCC 1:3:6 type CI and RCC cover and necesary excavation and earth work in hard/dense soil and disposal of spoil to a distance not exc 50 mtr and necessary testing complete all as shown in electorical plate No 03 connected to earthing test point including following elements/works all as specified.
Taking down carefully after disconnecting electrical/water supply connections and transporting to the work shop for carry out the servicing / over hauling of the storage type electric water heaters (Geysers) of storage capacity 25 / 50 litres of any make / type by cleaing the inner surface of the tank / heating element with chemical to remove the scaling / rust & reassembling the same after replacing burnt out parts and refixing on its original position including testing complete all as directed.
Supply & replace heating element of the following ratings as required at site including rubber washer/packing. Make : "RECOLD /THEETA / SWARNA or equivalent ISI marked. (a) 1/1.5 KW
Supply & replace base assembly complete i.e., "SIPHON SET" inlet, outlet, thermostat pockets with drain plugs & screws for fixing the element inclusive of clamps for holding the element with nuts & bolts.
Supply & replace thermostat stem type suitable for geysers 25 / 50 litres. ISI marked.
Supply & replace cut off for geyser as per sample suitable for geysers 25 / 50 litres. ISI marked.
Supply & replace 15 mm dia chromium plated copper tube with two brass adopters 18" long and fixing in position for hot water/outlet connections.
Supply & replace PVC connecting pieces with two brass adaptors 18" long & fixing in position for cold / Hot water / inlet connection.
Supply & fix in replacement stop cock brass ISI marked 15mm dia & connecting up in position all as directed.
Repairs to leaking copper inner water tank by soldering/brazing including replacement of nut, bolts etc complete all as specified.
Repairs to siphon set by soldering/brazing including replacement of bolts/nuts/washers/rubber gaskets etc complete all as directed.
Supply & fix in replacement Gun metal Non-Return valve 15mm dia complete all as specified.
Supply & replace indicator lamp rectangular / round type suitable for 25 / 50 litres geysers.
Supply and fix in repair pressure release valve 15mm dia complete all as specified.
Supply and replace unserviceable corroded bottom plate of geyser with PVC two portion plate complete as specified.
Supply & fix GI Pipe medium grade 15mm dia on wall ceiling for geyser inlet including GI specials clamps etc & wherever necessary making of holes in the walls incl redressing disturbed surfaces complete all as directed.
Material & labour for painting of storage type water heater any capacity (25/50 litres) after preparation of surface and applying two coats of synthetic enamel paint, white externally complete all as specified.
Taking down the defective ceiling fan of any sweep and make after disconnecting electrically & mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:- (a) Servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation value complete.
(b) Re-winding of ceiling fan any sweep taking down vide item No 93 with same guage supper enameled copper wire to maintain speed at load.
(c )Painting of ceiling fan any sweep taking down vide item No 93 by applying one coats of synthetic enamel paint after preparation of surface complete.
Supply & replace ball bearings for exhaust/ceiling fan of any sweep. Make : SKF/NBC/FAG
Supply & replace GUN METAL BUSH for exhaust / ceiling fan of any sweep.
Supply and fix in repairs fan condenser of following sizes :- (a) 2.5 mfd
(b) 4 to 6 mfd, Make : Asian / EPCOS
Supply anf fix in repair rubber reel, nut bolts, washer, split pin complete set by dismantling existing u/s are as specified.
S & F Fan connector suitable for wire connection.
Supply & Fix ceiling fan down rod of MS pipe 15mm bore 1.2 Mtr length oulding cutting/threading making tide for fixing providing check nuts wachers etc complete.
Taking down the repairable exhaust fan of 300 MM / 380 MM sweep, any make, single phase, 230 volts, 50 hz, AC after disconnecting electrically and mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:- (a) Servicing/overhauling the exhuast fan by thoroughly clelaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the resistance value.
(b) Re-winding of exhaust fan 300 MM / 380 MM sweep, any make, taking down vide item No 94 with same guage supper enameled copper wire to maintain speed at load.
(c ) Painting of exhaust fan 300 MM / 380 MM sweep, any make, taking down vide item No 94 by applying one coats of synthetic enamel paint after preparation of surface complete.
Supply & replace ball bearings for exhaust/ceiling fan of any sweep. Make : SKF/NBC/FAG
Supply & replace GUN METAL BUSH for exhaust / ceiling fan of any sweep.
All as per above item No- 94 but exhaust fan 450mm sweep. (a) Servicing/overhauling the exhaust fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation resistance value.
(b) Re-winding of exhaust fan 450 MM sweep, any make, taking down vide item No 95 with same guage supper enameled copper wire to maintain speed at load.
(c ) Painting of exhaust fan 450 MM sweep, any make, taking down vide item No 95 by applying one coats of synthetic enamel paint after preparation of surface complete.
Taking down the repairable air circulator wall mounted 300 to 450 mm sweep any make single phase 230 Volts, 50 Hz AC after disconnecting electrical and mechanically and transporting to the work shop dismantling examine and carry out the repairs as required and broght back to site re-fixing testing in all respect for smooth running and comprising of the following. (a) Servicing/overhauling the Air circulator industrial type of thoroughtly cleaning the bearing, shaft, stator, rotor and applying the lubricant/grease to the bearing including applying one coat of super enameled varnish over the winding to improve the resistance value.
(b) Re-winding of Air circulator 300 to 450 MM sweep, any make, taking down vide item No 96 with same guage supper enameled copper wire to maintain speed at load.
Taking down the defective flame proof ceiling fan of any sweep and make after disconnecting electrically & mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:-(a) Servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation value complete.(b) All as per item No 98 (a) here in before, but re-winding the burnt/short circuited winding with same guage supper enameled copper wire to maintain speed at load.
Taking down the existing unserviceabvle Geyser and handed over to MES store and fixing only new Geyser of capacity25/50 Ltrs vertical/ Horizontal type of any make inlcuding making Electrical / Water supply connection and additions / Alterations all Existing Brackets testing complete all as directed. Note : (i) Geysers 25/50 Ltrs will issued under schedule 'B' free for fixing only. (ii) Retreived Geyser has to be handed over to MES store yard. (ii) Refixing of existing Geyser with accessories in suitable condition
Taking down the existing un-serviceable exhaust fan of any sweep and fixing only new exhaust fan single phase 230 volts, 50 Hz including provision of new anti vibration rubber bushes, bolts, nuts, for mounting etc complete. Note : (i) Exhaust fan shall be issued under Sch 'B' free for fixing only. (ii) Retrieved Exhaust fan has to be handed over to MES Store. (iii) Refixing of existing Exhaust Fan with accessories in suitable condition.
Dismanlting existing defective/ damaged lightening protection conductor from complete roof and down conductor fitted on wall as as specified.
Supply and fix aluminium strip 25 x 3.15 mm with saddle and fixing screws and fixing screws etc for roof and down on wall up to ground up to test point complete.
Supply and laid in ground galvanised iron strip of size 32 x 6 mm as earth continuty conductor complete.
Supply and fix test point terminal block made of gun metal or phosphoras bronze size 75 x 75 x 25 mm drilled and screwed inc;uding 3 Nos 8 mm dia 25 mm long hax head screws complete.
Supply and fix air termination single pointed aluminium rod 12 mm dia 300 mm long all as speiifed.
Earthing complete with galvanised steel earth plate electrode 60 x 60 x 6 mm thick burned directly in ground earth pit not less than 2.25 mtr deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvansied iron strip 32 x 6 mm as earthing lead by means of bolts nuts check nuts and washers of galvanised iron steel all as shown in electrical plate No 5 connecting to earthing test point all as specified and testing complete.
M&L for Providing PCC block of size 15 x 15 x 10 cms with PCC 1:2:4 for mounting of aluminium strip with porcelain insulator on roof top all as specified and directed
Supply and fixing porcelain insulator for mounting of aluminium strip on roof top/ on wall for down conductor all as specified and directed
M&L for repairs to flame proof tube light fitting incl replacement of choke, tube rod 36 watts etc all as specified and directed
Providing services to attend and rectify Electrical complaint of internal and external electric supply. ( Repair/ Maintenance works) in entire Technical area (R&D Dighi, OCRI & Proof Range) with suitable qualified electrician and helper including carrying out following nature of job all as specified and directed by Engr-in-charge. Operating Staff Required - (i) One Electrician (Skilled) and One Mate Electrician (Semi Skilled) Shift Required - One shift of 08 Hours daily including Sudays and Holidays. Shift timing as decided by JE E/M or Enginner-in-Charge. (a) To attend no light complaint. (b) Replacement of UNSV switches /sockets/switch socket combinations of 6A/16A as per site conditions. (c) Replacement of defective/UNSV MCBs/MCCBs in DBs/LT Panels as directed. (d) Replacement of defective /UNSV tube lights fitting any type /size ,ceiling fitting recessed/surface .(e) Replacement of fused tube rods/CFL. (f) Repair to ceiling fan/exhaust fan/wall fan / air circulator / table fan incl replacement of condensor etc and making it functional (g) Checking and Repairing of switch boards removing short circuit if any and replacament of burnt wires etc. (h) Replacement of broken switch boards. Note :- (i) The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the fitting and fixtures functional. If replacement of parts/items is required to make the fittings functional, will be provided from supply only items/from store. (ii) The electrician and Helper who is on duty must be provided with common mobile cell to facilitate and render good services to the users and the same shall be deemed to be included in the unit rate. (iii) Complaint slip to be collected daily from complaint cell/AGE E/M Dighi office and same shall be returned on completion of job.(iv) All relevant norms and IE rules provisions shall be adhered while working on electric circuits and necessary protective devises and tools required shall be inclusive of the provisions and the same shall be deemed to be included in the unit rate. (v) Contractor shall provide all tools required for attending complaint with proper tool bag. (vi) If individual remains absent on site, contractor shall make an alternative arrangement ,If contractor fails to make such arrangement recovery shall be made at Rs. 1000 for electrician and for Rs. 750 for helper per day. (vii) Contractor shall provide all tools required for attending complaint with proper tool bag. (viii) Contractor shall regularly maintain attendence of persons and every morning register put up to Engr-in-charge or JE E/M.(ix) Any emergency HT/LT fault shall be rectified as per direction of Engr-in-charge/JE E/M. (x) Contractor have to be submitted valid Police Verification Certificate of electrician/helper at this office and security office of R&DE Dighi/OCRI/Proof Range at the time of commencement of work and obtain police verification certificate is a contractor responsibility. (All the documents (Ex. Residential proof, Adress proof, ID proof, Photos, police verification etc.) required in security office to entry in the technical area will be submitted by the contractor to security office and its contractors responsibiliy to produce the same at the time of commencement of work) (xi) Contractor have to submit Educational Qualification certificate to this office at the time of commencement of work, If contractor fails to bring educational qualification as per trade of electrician/ helper recovery shall be made at double the quoted rate as specified in Sch A as per included for same. (x) Contractor will submit the nominal roll and qualification certificate of every operator to Engr-in-charge at the time of commencement of work. (xi) All the documents: Residential proof, Address proof, ID proof, photos, police verification certificate, Bank details of individuals etc has to be submitted by the contractor at the time of commencement of work.(xii) The trades man employed must wear the uniform and shoes with name plate of individual and with name of firm. (xiii) All relevant norms of IE rules provisions shall be adhered working on electrical circuits and necessary protective device and tools required shall be provided by the contractor and the same shall be deemed to be included in the unit rate. (xiv) If any duty person is not present in installation immediately contractoer will provide alternative arrangement on duty if contractor fails to make such arrangement recovery shall be made at the double the quoted rate as specified in BOQ. (xv) The contractor shall provide all the necessary stationary such as book, attendance register etc to the operator for maintenance the plant running record. (xvi) Contractor shall submit the duty roaster, payment statement with operators passbook every 1st week of month.
Supply only electronic ballast 36 watts suitable for 36 w, T5 fitting
Supply only stepped type elctronic fan regulator 240 V 50 HZ , 100Watts flush type suitable for 1200/1400mm sweep ceiling fan complete
Supply only Insulation Tape (Dimenson-2.5 cm x 25 m x 0.125 mm). Make:- Steel grip
Supply only switch piano 5/6 amps.
Supply only Switch socket combination 5 amp 5 pin.
Supply only Switch socket combination 15 amp 3 pin universal.
Supply only switch modular 5A
Supply only switch modular 15A
Supply only Socket 6 amp 5 pin modular type.
Supply only Socket 16 amp 5 pin modular type.
Supply only starter 20/40 watt.
Supply only flourscent tube light of 1 x 18/20 watt slim type.
Supply only flourscent tube light of 1 x 28 watt slim type.
Supply only Flexible copper wire 23/0.0076
Supply only Cable PVC Insulated unsheathed standard copper conductor 1.5 sqmm
Supply only Cable PVC Insulated unsheathed standard copper conductor 2.5 sqmm
Supply only Cable PVC Insulated unsheathed standard copper conductor 4 sqmm
Supply only Cable PVC Insulated unsheathed standard copper conductor 6 sqmm
Supply only Flat twin core weather proof service cable 6 sqmm
Supply only of size Screw 35/8 mm
Supply only of size Screw 50/8 mm
Supply only of size Screw 60/8 mm
Supply only of size Screw 70/8 mm
Supply only PVC Box of size 7" x 8"
Supply only PVC Box of size 4.5" x 3" suitable for 15 amp switch-socket
Supply only Casing Caping of size 20 mm, ISI marked
Supply only rawl plug (Each box contains minimum 30 piece of wood stick)
Fixing only electric meter single phase for common supply (staircase & bldg) at new place or site condition or decided by Eng-in-Charge, including wooden box for fixing of electric meter on it of size 200mm x 300mm x 150mm with locking arrangement and fixing on wall, necessary copper wiring for incoming and outgoing connection upto 3 mtr each etc all as directed and specified by Engineer-in-Charge. Note- (i) Contractor insure that all common point are connected to this meter. (ii) If change in wiring required then this measures in wiring portion. (iii) Contractor collect electric meter from MES store yard.
To attend any brake down of the summer appliances i.e. split type AC, window type AC , water cooler ,desert cooler / air cooler and aquaguard of any capacity or make/model/ year if manufacture, installed at R&DE, OCRI, Proof Range complex as and when required during working /non working hours all as directed by the Engineer-in-charge. Note:- (i) Spares will be measured and paid separately under relevant item (ii) Complaint if not attended with in 24 hours after receiving complaint, penalty will be recovered at double the rate quoted by the contractor
Taking out carefully existing defective sealed compressor of window type AC 1.5/2 ton capacity by dismantling the same, supply and fixing new sealed compressor as per existing model and make including bracing, leak testing, vacuuming charging the oil, refrigerant as required to maintain design grill temperature, testing and commissioning in all respect all as specified and directed by Engineer-in-Charge.
All as per item No 141 above but for split type AC 1.5 / 2 ton capacity.
All as per item No 141 above but for storage type water cooler of 40 liters capacity.
All as per item No 141 above but for storage type water cooler of 60/150 liters capacity. Note for item No 141 to 144:- (i) Rate quoted deemed to include the cost of compressor oil for topping up and refrigerant. (ii) Spares will be measured and paid separately under relevant items.
M&L for taking down the existing defective fan/ blower motor and transporting to the work shop and dismantled burnt motor, removing the burnt winding & rewinding with super enameled copper wire of suitable size and gauge & replacement of unserviceable bearing of motor of following :- (a) Fan motor (two speed i.e low & high) for window type AC 1/5 HP.
(b) Condenser fan motor for water cooler 1/6 HP capacity
(c) Condenser fan motor for split type AC unit condensing unit /out door unit)
(d) Blower fan motor for split type AC unit (indoor/cooling unit)
Supply in repairs capacitors of following capacity:- (a) Capacitors 80-100/120 Mfd
(b) Capacitor 36 Mfd
(c) Capacitor 45-50 Mfd
(d) Capacitors 10-25 Mfd
(e) Capacitor 6.3 Mfd
(f) Capacitor 4 Mfd
(g) Capacitor 2.5 Mfd
Disconnecting and taking out the defective split type AC 1.5/2.0 ton capacity remote circuit complete and supplying and fixing new remote circuit (PCB) as per existing make/model complete all as specified and directed by Engineer-in-Charge.
Removing the damaged PUF insulation of suction pipe and supplying and fixing new thermal sleeve insulation for suction/delivery line including providing hard plastic tape over the thermal insulation for split type AC 1.5/2.0 ton capacity etc complete all as directed by Engineer-in-Charge.
Supply and fix in replacement overload protectors relays for the following:- (a) Water cooler
(b) Window type AC
(c ) Split type AC
Taking out defective fan blade and supplying and fixing new blades for water cooler of 40/80/100 liters capacity complete all as directed by Engineer-in-Charge
Taking out defective push cock and supplying and fixing new push cock chromium plated brass, 15 mm bore of approved make for water cooler complete all as directed by Engineer-in-charge.
Taking out old PVC conduit condensation water pipe 20mm dia from indoor unit to ground floor by using new PVC conduit ISI mark condensation water pipe 20mm dia, fixing/laying on wall by using clamps and insert into wall by making hole and grouting with cement mortar complete all as specified and as directed by Engineer-in-Charge.
Taking down old metallic socket neutral enclosures single pole with 2 pin and supply and fixing, new single pole and neutral enclosure with 2 pin and earth plug socket complete with one SP MCB-240 volts, 32 amps fixed on sheet metal encloser complete all as specified and directed by Engr-in-Charge.
Taking down window type AC of any capacity / make/ model from existing position and carry out the servicing by cleaning the unit with water, tightening the terminal connections to avoid loose connections, applying the oiling/greasing to fan motor, bearings all as specified for smooth running including cleaning the air filter/check the thermometer setting etc. and directed by Engineer in charge.
All as per item No 154 above but for split type AC 1.5-3.0 ton capacity.
Taking down from existing position storage type water cooler of any capacity and make and servicing the same by cleaning of water tank, cleaning condensing unit by hand blower and including supply and replacement of damaged aluminium hinges, wiring with PVC insulated copper wire of same gauge, PVC drain pipe 25 mm dia, 1.5 m length, servicing/oiling/greasing of condenser motor with supply and replacement of mounting rubber bushes, tightening of all loose parts, contacts, wiring, nuts, bolts, complete including re-fixing in original position, testing and commissioning to the entire satisfaction of Engineer-in-Charge.
All as per item No 156 above but with out painting Note for the item No. 154 to 157:- Servicing shall be carried out in the presence of Engr-in-charge.
(a) Supply and fix in replacement of relay suitable for window type AC
(b) Supply and fix in replacement of relay suitable for water cooler.
(c) Supply and fix in replacement of relay suitable for split type AC of any capacity. Make :- USHA/SHRIRAM/ ANNAPURNA
Supply and fix in replacement of air filter pad for window type AC
Supply and fix in replacement of filter pad/wood wool net for desert cooler and air cooler as per sample.
Supply and fix in replacement of outer casing for window AC 1.5 TR.
Supply and fix in replacement of front grill for window AC of suitable size / shape / model as required at site. Make :- VOLTAS / LG /Carriar
Supply and fix in replacement of auto cut thermostat for window type AC / split type AC.
Supply and fix in replacement of auto cut thermostat for water cooler.
Supply and charging / topping up refrigerant R-22 to window type / split type AC as directed by Engineer-in-charge.
Supply and charging / topping up oil to window type / split type AC and Water cooler compressors as directed by Engineer-in-charge.
Detecting of gas/refrigerant leakage in the system by pressure testing with nitrogen gas and rectifying the same by brazing if required replace the copper tube as required and vacuumising, recharging of refrigerant F-22 /F-12/Refron/Mafron as recommended by manufacture to maintain the design grill temperature by testing & commissioning including changing of compressor oil (CAPILA-D) for window type AC 1.5/2 TR capacity complete all as specified and directed by Engineer-in-Charge.
All as per item No 168 here in before but for split type A/C 1.5/2 TR capacity.
All as per item No 168 here in before but for water cooler any type/capacity.
S&F in replacement of water pump for desert cooler / air cooler vertical type single phase, 230 Volts, 1/7 HP, 900 RPM as per existing model all as directed by engineer-in-charge.
M&L for painting out door unit of 1.5/2.0/3.0 Ton capacity split type A/C by one coat of spary painting using super enamel paint over one coat of anticorrosive primer including preparation old surfaces by scraping etc complete all as specified and directed by Engineer-in-Charge
M&L for painting Window type AC unit of 1.5/2.0 Ton capacity by one coat of spary painting using super enamel paint over one coat of anticorrosive primer including preparation old surfaces by scraping etc complete all as specified and directed by Engineer-in-Charge
Taking down the defective voltage stabilizer 2-5 KVA, carry out the repair by replacing the unserviceable parts & refixing the same including testing. (a) Volt meter (As per sample)
(b) Indication lamp
(d) Transformer rewinding
Supply and provide 3 core 2.5 sqmm flexible copper wire including dismantling of existing copper cable complete all as specified and as directed by Engineer-in-charge.
Supply and provide 3 core 4 sqmm flexible copper wire including dismantling of existing copper cable complete all as specified and as directed by Engineer-in-charge.
Core cutting in any type of wall as per standerd diameter to pass Inlet/outlet pipes through wall or as directed by Engineer-in-Charge
S&F copper tubing along with necessary insulation as per manufacture standerd for 1.5/2 TR split AC unit, or as directed by Engineer-in-Charge
Supply and fix universal remote for 1.5/2 TR AC, remote is as per same make of AC unit or as directed by Engineer-in-Charge.
M/S OMSAI ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .