Loading…
Loading…
Tender ID
Tender Value
Refer Docs
EMD Value
₹46,705
Closing Date
20 Jan 2026, 11:00 pmClosed
Nirmithi Kendra Raichur
Mohan Krishna J E
Supply Installation and Commissioning of Central AC to Nirmithi Kendra, Raichur
NKR/2025-26/IND0015/CALL-3
NKR/2025-26/IND0015/CALL-3
Open
Two Tender Document System(Two Cover)
Special Officer Nirmithi Kendra Raichur
2 documents required · 2 mandatory
As per Tender Document
₹500
₹46,705
12 Jan 2026
12 Jan 2026
22 Jan 2026
20 Jan 2026
16 Jan 2026
Lifting shifting, Loading Unloading and Installation ,transportation charges
Supply & Installation of Propeller fan. 100 CFM
Supply & Installation of Mixed flow inline fan. 500 CFM 15MM static
Supply & Installation of Louverwith bird mesh
Supply & Installation of PVC pipes. Dia -110mm
Supply & Installation of PVC pipes. Dia -160mm
Supply & Installation of Dise valve. Dia -100mm
Supply & Installation of Uninsulated Flexible duct. Dia -150mm
Supply installation testing and commissioning of Al.powder coated Collar damper.
Supply, installation testing and Commissioning of Aluminum Extruded powder coated Grill with blade deflection of 0 - 30 deg as required.
Supply, installation, testing and balancing of GSS Volume Control Dampers with operating handle for Supply air duct branches. The volume control damper shall be of low leakage type with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS. And with necessary flanges for connection etc., as per specification.
Supply ,installation and testing of CLASS O 9mm thick, Elastomeric nitrile rubber or Physically Cross linked polyolefin foam Thermal insulation.
Supply ,installation and testing of Accoustic lining with Physically Crosslinked open cell polyolefin foam insulation for supply and return duct of density 30kg/m3 of Fire Retardant grades with thickness of 10 mm NRC of material should be atleast 0.35 tested as per ISO 354-2000 and calculated in accordance with ASTM C423-90A.
Supply, fabrication, installation fire resistance flexible double canvas sleeve for ductable split and Airwasher fan .
Supply, Fabrication, installation and testing of sheet metal ducts (FACTORY FABRICATED DUCTS) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods, anchor bolts, GI bolts & nuts, canvas connections, duct dampers & splitter dampers etc.,and as required by the specifications. All size duct should be with TDF joints. No C & Ss clip joints should be used 24g
Supply, Fabrication, installation and testing of sheet metal ducts (FACTORY FABRICATED DUCTS) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods, anchor bolts, GI bolts & nuts, canvas connections, duct dampers & splitter dampers etc.,and as required by the specifications. All size duct should be with TDF joints. No C & Ss clip joints should be used 22g
Condensate drain piping for AC Indoor units with hard UPVC pipes with necessary fittings prepainted supports, clamps & with insulation of 9mm thick Nitrile rubber tube insulation of following below sizes. Supply and Installation of Dia 32mm
Additional gas and oil and testing and commissioning of the VRF units with R-410 A.
Supply and installation of suitable refnut joints to connect the VRF indoor units with outdoor unit.
Supply and Installation of MS Stand for Outdoor Unit. For VRF Unit
Supply and laying of Power and Control Cabling and all associated Electrical works for VRV units. 4C x 16 Sqmm copper cable
Supply and laying of Power and Control Cabling and all associated Electrical works for VRV units. 3C x 1.5 Sqmm communication cable
Supply and Installation of Refrigerant Copper piping both suction line and liquidline , As per Tender Document Specification
Supply of HARD DRAWN / softdrawn Refrigerant Copper piping both suction line and liquidline , for harddrawn the copper piping thickness should be As Per Tender Document Specification
Supply and Installation of 22.2 mm with 13 mm thick tubular insulation , Supply of HARD DRAWN / softdrawn Refrigerant Copper piping both suction line and liquidline , for harddrawn the copper piping thickness should be 16 g and for softdrawn the copper piping thickness should be 20 g .
Supply and Installation 28.6 mm with 13 mm thick tubular insulation , Supply of HARD DRAWN / softdrawn Refrigerant Copper piping both suction line and liquidline , for harddrawn the copper piping thickness should be 16 g and for softdrawn the copper piping thickness should be 20 g .
Supply and installation of VRF Indoor unit of following capacity, 7.1 TR (High static ductable unit), Supply, Installation
Supply, of VRF Units, Supply,Installation, testing & commissioning of Modular type Variable Refrigerant Flow (VRF)1.1and 22 hp, , Refrigerant Flow (VRF) outdoor units. .
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
CENTRAL AC TENDER NK TENDER DOCUMENT-12012026.pdf
Tender Document • 1.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .