Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC AT ROAD HATIALI PO CHABUA DIST DIBRUGARH ASSAM 786184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹49.2 L+₹4.2 L (9.26%)Rejected-Finance MES TINALI PO CHABUA DISTT DIBRUGARH ASSAM 84 | CHABUA | DIBRUGARH | ASSAM | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹49.3 L+₹4.3 L (9.65%)Rejected-Finance PO HATIALI SIDING CHABUA DIST DIBRUGARH ASSAM 786184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹49.5 L+₹4.5 L (10.1%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹49.5 L+₹4.5 L (10.1%)Rejected-Finance C O SREE SUMANGAL A T ROAD TINSUKIA ASSAM 786125 | TINSUKIA | DIBRUGARH | ASSAM | 786125 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹42.4 L
EMD Value
₹84,800
Closing Date
29 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) CHABUA
GE(AF) CHABUA Dibrugarh-Dist Assam-786102
As per BOQ
2024_MES_641857_2
544/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) CHABUA
As per tender documents
6 documents required · 6 mandatory
₹500
GE(AF) CHABUA
₹84,800
Yes
10 May 2024
10 Apr 2024
1 May 2024
10 Apr 2024
29 Apr 2024
22 Apr 2024
Amount
SCH 'A' PART-I
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. n exc 10 sqm on plan and nexc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for providing Cement concrete type D2, 1:4:8 using 40mm graded stone aggregate in in foundations, filling and mass concrete complete all as specified and directed.
M&L for RCC, M-25 (Design mix) using 20mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for Brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for Rendering 10mm thick on fair faces of brickwork or concrete surfaces of 1;4 surface to be finished even & smooth without using extra lime or cement complete all as specified and directed.
M&L for Preparation of new surfaces and applying two coats of cement base paint over one coat of primer on walls complete all as specified and directed.
M&L for Hardcore of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface using broken boulder or stone complete all as specified and directed.
M&L cement concrete 1:4:8 type D2 (40mm graded stone aggregate) as in sub base 75mm thick, complete all as specified and directed.
M&L for 75 mm thick PCC type C-2, 1:3:6 as in plinth protection complete all as specified and directed.
S&F Mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long diameter of neck exc 20mm complete all as specified and directed.
S&F Mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W (Gde E 250 quality A complete all specified and as directed.
M&L for bringing approved soil from out side MoD land including raising (or lowering) earth spreading in layers n exc 30cm thick watering ramming/rolling and finishing to required size shape etc n exc 1.5m high from base and deposited where directed.
Manufacture, Supply, Transportation and Installation of Prefabricated Flat Pack Modular High Altitude Containerized Living Shelter of size 6.00 mtr x 3.00 mtr upto height of 3.20 mtr (Portable cabin) including Toilet block, store, Electrical and plumbing fittings and fixtures (Internal Size - Size 5.84 mtr x 2.84 mtr x 3.00 mtr) complete all as specified. Note:- The shelter should be able to be easily dismantlable for transportation. The Shelter parts like floor. Walls, Roof etc. should be capable of assembling & disassembling by 5-6 men & Hydra Crane in 7-8 Hrs.
Surface excavation n exc 30 cm deep and averaging 25 cm deep in soft/loose soil and getting out complete all as specified and as directed.
M & L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete and as specified.
M & L for Sand filling under floors 25 mm thick including watering and consolidation complete all as specified and directed.
M&L for coloured, glossy finish precast 60mm thick cement concrete interlocking paver block Grade M-35 made with grey cement and pigment manufactured by automatic hydraulic compression with high compressive strength, any size, pattern and shape as approved by GE, laid dry in patterns with different colour paver block /tiles as in path, complete all as specified and directed.
S&F 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
M&L for preparation of concrete Surfaces of any description over 10cm girth or width, not otherwise described applying two coat of synthetic enamel paint complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation of manholes etc as shown in drawings complete all as specified and directed.
M&L for Brick work sub class 'B'' bricks (old size) straight or curved on plan exc 6 m mean radius built in cm (1:4) as in manholes etc complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate in bed plates bends coping benching etc including slighting moulded or chamfered edges complete all as specified and directed.
M&L for Pre cast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in manholes cover set in CM 1:6 including necessary form work complete all as specified and shown on drawings. Note:- Reinforcement shall be measured paid for separately
M&L for TMT bars to 6 mm to 8 mm dia bar bent to shape including cranking bending spirally, hooping and binding with mild steel (Annealed) wire not less than 0.9 mm dia complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channels and drains of manholes etc complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc complete all as specified and directed.
M&L for 15 mm thick cement plaster in CM 1:4 on brick or concrete surfaces mixed with water proofing compound as per manufacturer's instructions surfaces finished even and smooth without using extra complete all as specified and directed.
Supply only water proofing compound complete all as specified and directed.
M&L for PCC 1:3:6 type D-2 using 40 mm crushed graded stone aggregate as in bed of RCC pipe 150 mm NP-3 bore including packing under hunching against the sides of pipe after they are laid and tested complete all as specified and directed.
M&L for 150mm bore (internal dia) Reinforced Concrete pipes, class NP-3 laid in trenches and jointed on concrete bed to required slope jointed and plastered complete all as specified and directed. Note:- Concrete bed cell be measure and paid separately.
M&L for on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 10 users Septic tank shall be installed as per manufacturer's instruction complete all as specified and directed.
M&L for Construction of Soakage well for 10 users as shown on drawings complete all as specified and directed.
SCH 'A' PART-II
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core x 35 Sqmm complete all as specified and directed.
All as per item No. 38 here-in-before but of 2Core. x 16 sqmm (Main LT Panel to each DB and street light) complete all as specified and directed.
Excavating in trenches, nexc 1.5 m wide and exc. 1.50 metre but nexc 3.00 mtr in depth; for foundation, etc nexc 10 sqm on plan and nexc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Supply and laying well burnt Sub Class 'B' locally available best quality laid in trenches perpendicular to UG cable above sand cushioning for cable protection complete all as specified.
Supply and spreading dry coarse sand in trenches for protection of underground electric cable, spread in uniform 23 cm thickness and punned down gently to 18 cm complete all as specified and as directed.
Supply & Fix Factory made, sheet steel distribution boards, SP and N, 8 Ways, 240 Volts double door type, protection class (IP-42) suitable for mounting MCB DBs confirming to IS-13032, IS-8623, BS-5484 with min 200 Amps rating copper bus bar complete all as specified and directed.
S&F MCB SP 6-32 Amps (B curve), breaking capacity 10 KA, 240 Volts with cable connection and copper lugs complete all as specified and directed.
S&F MCB SPN 40 Amps (B curve), breaking capacity 10 KA, 240 Volts with cable connection and copper lugs complete all as specified and directed.
Supply, installation, commissioning and testing of LT outdoor feeder panel of size suitable to accommodate mentioned accessories, factory made (CPRI approved) outdoor compartmental type double door both side openable with hinged doors & locking arrangement made out of not less than 3.15 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50 x50 x6mm angle iron frame including earthing stud labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 stage process), duly fixed in ground with PCC foundation (1:2:4) type B1 with danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled (white) with letters figures and conventional skull and bones in signal red colour suitable for 3 phase 4 wire system 500Volts grade with necessary wiring with PVC sheathed strander al conductor of appropriate length size with and including fixing lugs bolts, screws etc complete all as specified and directed. For safety , panel shall be finger touch proof and it should have IP-20 Protection in module door open condition. Busbars shall be made of high conductivity, and high strength Aluminum E91 grade as per IS 5082-1981, of rectangular cross sections better suitable for full load current for phase bus bars and half/ full rated current for neutral bus bar or as per requirement . The busbars shall be supported on non-breakable, non-hygroscopic epoxy resin or glass fibre reinforced polymer insulated supports. The material and the spacing of the Busbar supports should be same as per the type tested assembly (TTA). All bus bars shall be provided in a separate chamber and all connections shall be done by bolting. Panel comprising of the following accessories:- Incoming:- (a) Aluminium busbar of rated capacity 200 Amps cover with PVC insulated sleeves including insulator, nuts, bolts etc including connection complete - 01 set (b) Supply and fixing MCCB 3 pole 415 Volts of breaking capacity of 16 KA of 125 Amps with Fixed thermal and magnetic setting-01 No (c) Neon indicator lamp with holder (Yellow, Blue, Red)- 01 set (Set of three) (d) Digital VAF meter with suitable CTs - 01 No. Out Going:- (a)Supply and fixing MCB SPN of 40 Amps-08 No (for each bldg DB - 06, Street light- 1 Spare - 1)
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI strip 25 x 4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3, including exc & earth work in any type of soil, disposal of soil, providing alternate layer of charcoal and common salt, construction of pcc earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B1 cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed at site. Note:- (i) Main earth lead beyond 7.5 meter shall be measured and paid separately through deviation order.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
M&L Steel Tubular Swaged welded Pole, type 410 SP-31 (9.00 metres long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws, etc. including applying Two Coat of Black Bituminous Paint Internally and Externally up to Planting Depth and applying with Two Coats of Aluminium Painting over a Coat of red oxide primer including Writing MES LT Pole and Blue reflector strip with Synthetic Enamel Paint (First Grade/quality), complete all as directed. Note:- Earth work and PCC work will be measured and paid separately.
M&L for Cement Concrete (1:4:8) type D-2 (40mm Graded Stone Aggregate) as Lean Concrete, Bed Concrete in Foundation of Poles, etc., including Formwork (as required), complete all as directed.
M&L for Cement Concrete (1:3:6) type C-2 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as required), complete all as directed.
M&L for Cement Concrete (1:2:4) type B-1(20mm Graded Stone Aggregate) as in Coping of Poles, etc. including Formwork (as required), complete all as directed.
S&F 60 Watt LED streetlight made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, iP66 protection, impact resistance of iK07 & 10 KV external SPD. Efficacy 120lm/W complete all as specified and directed.
Supply and fix street light bracket, bend to 120 degree angle, made out of 40 mm bore, galvanised iron, light grade tubing (approx 1.5 mtr in length) including necessary two nos suitable size of clamps with nuts, bolts and washers, etc. and two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
S&F Cable Junction Box 200X160X98mm in size, made out of thermoplastic sheet having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32-2 nos) fixed on poles with flat aluminium clamps of size 25x3mm, nuts, bolts, washers etc. complete all as specified and as directed.
M&L for cutting CI/GI pipe line providing connection for new pipe line with fittings complete all as specified and directed.
Supply, laying and testing galvanized iron pipes of 90mm bore medium grade with all necessary ( such as bends, elbow, tees, short pieces of medium grade pipe connector, back nuts, caps, plug and unions on piping as required, complete all as specified and as directed by Engr-in-Charge.
All as per item No. 57 here-in-before but size 25mm dia, complete all as specified and as directed by Engr-in-Charge.
Supply and fix Cast Iron Sluice Valves size 80mm dia long body with flanged ends of class 1.0 PN including jointing materials, nuts, bolts, rubber gasket and washer etc complete all as specified and directed.
Supply and fix Gate Valves (Brass Insert) of 25 mm bore complete all as specified and directed.
Construction of brick masonry valve pit / chamber of internal dimension 90 cm x 90 cm x 90 cm depth with sub class 'B' old size bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6 mm angle iron 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary breaking of the existing old chamber, excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m, complete all as specified and as directed.
Supply and fixing Water heater storage type, electric supplied and installed complete of capacity 25 litre 5 star rated, rust and shock proof body including heavy grade pipe for cold and hot water (450mm long) complete all as specified and as directed.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 32A complete all as specified and as directed.
Supplying and fixing smart single phase two wire dual source prepaid energy meters BIS 15884 marked in existing meter board/floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 along with parallel home display split unit with inbuilt load control switch containing pro vision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition complete all as specified and directed.
M/S DURGA CONSTRUCTION & CO
M/s Krishna Construction
Dilip Kumar
M/S D P BERLIA
M/S MAHATO ENTERPRISE
M/s PRABIR ENTERPRISE
M/S S. P. ENTERPRISE
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .