| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | ₹37.6 L Quoted ₹38.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹38.7 L+₹52,760 (1.38%)Rejected-Finance 300 STREET NO 10 PREM BASTI SANGRUR PB PUNJAB 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | ₹38.7 L+₹52,760 (1.38%) | L2 | Rejected-Finance L2 |
| 3 | L3₹44.3 L+₹6.1 L (15.9%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹44.3 L+₹6.1 L (15.9%) | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | R D Bansal L3 | Jawandha Enterprises L1 | krishna engineers L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, fixing, including commissioning of 16M high mast 360/150--3/3 shaft in two section suitable for 47 m/sec wind speed along with head frame, luminaires carriage suitable for 6-9 luminaires in symmetrical arrangement and other accessories manufactured in factory. Supply of raising lowering system comprising double drum winch, 4mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial.
(a) Supply and fix foundation bolts along with nuts, washers, anchor plate and common template.
(b) Supply and fix LED type single dome aviation obstruction light.
(c) Supply and fix outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals.Complete all as specified and as directed.
Make:- Bajaj/Utkarsh/Jindal power corporation . | 1 | Each Job | 3,10,000 ₹3,10,000 | 2,10,000 ₹2,10,000 Lowest | 2,85,000 ₹2,85,000 |
| 2.00 | Supply, installing,commissioning and testing 100 Watt Solar AIO LED Street Light with luminair efficacy of 150 lm/W with minimum lumen output of 15000 lumens.The solar panel should be of 150W with Monocrystalline cells with 78Ah LiFePO4 battery pack. Manufacturers Logo/name must be engraved/Embossed on luminaire Housing. Manufacturer must have In-House NABL accredited laboratory with scope of testing & callibration of Electrical, Mechanical & Photometry Parameters as per IS10322:2012, IS16104, IS16106, IEC60598-1, IEC62262:2002, IEC60068-2-75, IEC60529, IES LM79, IS16102 (Part 2, Clause 8).Solar light fitting should be reliable to fit on 410 SP-31 9.00 meter long steel tubular pole complete all specified and as directed by Engineer-in-charge.
Notes:- The bidder shall submitt the following documents alongwith sample for approval of sample by GE
(1) LM79 Report from NABL Accredited Lab of Light supplied.
(2) Technical Data Sheet of Solar Street Light.
(3) Type Test Report of Solar Street Light.
(4) BIS Certificate of Battery.
(5) LM80 Report of LED Chip used in fixture.
(6) Data Sheet of LED Chip used in fixture. | 5 | Each | 55,000 ₹2,75,000 | 35,000 ₹1,75,000 Lowest | 51,000 ₹2,55,000 |
| 3.00 | Material and labour for earthing complete with galvanised steel earth Coil of 50 mm dia have 115 turns, burried directly in to ground ( earth pit size should be 1500mm X 600mm + size of coil) not less than 1500 mm + Coil Size deep below GL with top edge of earth coil not less than 1500mm below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 600mm all around the coil, connected to GI lead wire of 4 mm dia (1.75 m Long) by means of nuts, bolts and washers, checknuts of GI and distance of the earthing bore from the pole should be 1200mm Minimum complete all specified and as directed by Engineer-in-charge. | 5 | Each set | 3,000 ₹15,000 | 2,500 ₹12,500 Lowest | 2,500 ₹12,500 Lowest |
| 4.00 | Material and labour for reinforced cement concrete foundation for the 16 m high mast light considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth including excavation and earth work including the erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour and Installation of the mast feeder pillar by grouting the stand in concrete complete all as specified and as directed by Engineer-in-charge. Notes:- (i) Foundation for hight mast light shall be as recommended by OEM and Designed from IIT/NIT/ Govt Engineering college' as directected by GE and submitted to GE for approval. (ii) Foundation design shall be approved by GE in writting.(iii) The cost of design shall be included in the quoted rates. | 1 | Each Job | 29,000 ₹29,000 | 30,000 ₹30,000 | 25,000 ₹25,000 Lowest |
| 5.00 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp complete all specified and as directed by Engineer-in-charge. | 24 | Each | 3,200 ₹76,800 | 2,500 ₹60,000 Lowest | 2,800 ₹67,200 |
| 6.00 | Connecting /disconnecting connection of air-conditioner in married quarters, OTM, offrs Mess from the existing over head lines complete all specified and as directed by Engineer-in-charge. Note:- Cables and materials for connection will be provided by occupant /user of the accn | 150 | Each Job | 150 ₹22,500 | 100 ₹15,000 | 95 ₹14,250 Lowest |
| 7.00 | Material and labour for providing team of electrian amd helper/ labour, transport and T&P for locating the fault in HT/LT line in OH/UG Line/cable in by visual inspection recce of faulty area and rectify the fault by means of replacement of unservicible Jumpers / fuse wires / burnt lugs / MCCB etc. including restrain of broken/loose ACSR counductors / earth wire etc.and resume the power supply as early as possible. If cable is required to make temporary connection to resume the supply temporarly till the fault is rectify in HT/LT lines, the cable shall be given by MES from the AGE E/M store all as directed by Engineer-in-charge
Area: The area to be covered are:- 66 KV Grid, Sub Stn No.3, AMN Dump Barsat and Baffle Range Dhablan Notes:-(i) Materials requried for fault repairs will be measured under relevant items included in BOQ.
(ii) Contractor will depute the dedicated team and necessary transportation, he will completely responsible for all the safety aspects of his team. No dispute regarding safety of person would be entertain later on. If any mishappening occures during rectifaction of fault in HT/LT lines contractor will be fully liable to bear all the expenses of indls.
(iii) Contractor will provide all set of T & P, communication device (Mobile Phone) to deployed persons, electrcian team for each sub station required for repair of HT/LT Electrical switch gear system including safety equipment such as All type of T&Ps (Bamboo ladders, screw drivers, wire/cable cutters with blades, multi meters, cutting plairs, torch lights etc) for routine maintenance and protection of the trademan incl safety equipment such as Hand gloves, Rubber boots, Sefety belt and helmets etc. | 4,200 | Each job | 150 ₹6,30,000 | 150 ₹6,30,000 | 132 ₹5,54,400 Lowest |
| 8.00 | Supply only the HT copper fuse wire of 5 Amps capacity. | 3 | Kg | 600 ₹1,800 | 1,200 ₹3,600 | 400 ₹1,200 Lowest |
| 9.00 | Supply only the HT copper fuse wire of 10 Amps capacity. | 2 | Kg | 610 ₹1,220 | 1,200 ₹2,400 | 400 ₹800 Lowest |
| 10.00 | Supply only the HT copper fuse wire of 20 Amps capacity. | 2 | Kg | 630 ₹1,260 | 1,200 ₹2,400 | 400 ₹800 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Aug 2026, 6:00 pmClosed
CWE Patiala
HQ COMMANDER WORKS ENGINEER BLDG No 26 NEW LALBAGH PATIALA 147001 Contact - 01712200082
REPAIR/MAINT OF HV/LV ELECTRCAL SYSTEM, DAY TO DAY COMPLAINTS AND IMPROVEMENT OF MES INSTALLATIONS AND CONNECTED WORKS AT SEC A, DABLAN and BARSAT UNDER GE (NORTH) PATIALA
2026_MES_778902_1
CWE/PAT/T-36/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE (North) Patiala
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
₹80,000
18 Sept 2026
16 Jul 2026
15 Aug 2026
16 Jul 2026
13 Aug 2026
30 Jul 2026
16 Jul 2026 - 23 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, fixing, including commissioning of 16M high mast 360/150--3/3 shaft in two section suitable for 47 m/sec wind speed along with head frame, luminaires carriage suitable for 6-9 luminaires in symmetrical arrangement and other accessories manufactured in factory. Supply of raising lowering system comprising double drum winch, 4mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial.
(a) Supply and fix foundation bolts along with nuts, washers, anchor plate and common template.
(b) Supply and fix LED type single dome aviation obstruction light.
(c) Supply and fix outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals.Complete all as specified and as directed.
Make:- Bajaj/Utkarsh/Jindal power corporation . | - | Each Job | 1.25 | - |
| 2 | Supply, installing,commissioning and testing 100 Watt Solar AIO LED Street Light with luminair efficacy of 150 lm/W with minimum lumen output of 15000 lumens.The solar panel should be of 150W with Monocrystalline cells with 78Ah LiFePO4 battery pack. Manufacturers Logo/name must be engraved/Embossed on luminaire Housing. Manufacturer must have In-House NABL accredited laboratory with scope of testing & callibration of Electrical, Mechanical & Photometry Parameters as per IS10322:2012, IS16104, IS16106, IEC60598-1, IEC62262:2002, IEC60068-2-75, IEC60529, IES LM79, IS16102 (Part 2, Clause 8).Solar light fitting should be reliable to fit on 410 SP-31 9.00 meter long steel tubular pole complete all specified and as directed by Engineer-in-charge.
Notes:- The bidder shall submitt the following documents alongwith sample for approval of sample by GE
(1) LM79 Report from NABL Accredited Lab of Light supplied.
(2) Technical Data Sheet of Solar Street Light.
(3) Type Test Report of Solar Street Light.
(4) BIS Certificate of Battery.
(5) LM80 Report of LED Chip used in fixture.
(6) Data Sheet of LED Chip used in fixture. | - | Each | 11 | - |
| 3 | Material and labour for earthing complete with galvanised steel earth Coil of 50 mm dia have 115 turns, burried directly in to ground ( earth pit size should be 1500mm X 600mm + size of coil) not less than 1500 mm + Coil Size deep below GL with top edge of earth coil not less than 1500mm below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 600mm all around the coil, connected to GI lead wire of 4 mm dia (1.75 m Long) by means of nuts, bolts and washers, checknuts of GI and distance of the earthing bore from the pole should be 1200mm Minimum complete all specified and as directed by Engineer-in-charge. | - | Each set | 53 | - |
| 4 | Material and labour for reinforced cement concrete foundation for the 16 m high mast light considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth including excavation and earth work including the erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour and Installation of the mast feeder pillar by grouting the stand in concrete complete all as specified and as directed by Engineer-in-charge. Notes:- (i) Foundation for hight mast light shall be as recommended by OEM and Designed from IIT/NIT/ Govt Engineering college' as directected by GE and submitted to GE for approval. (ii) Foundation design shall be approved by GE in writting.(iii) The cost of design shall be included in the quoted rates. | - | Each Job | 10 | - |
| 5 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp complete all specified and as directed by Engineer-in-charge. | - | Each | 10 | - |
| 6 | Connecting /disconnecting connection of air-conditioner in married quarters, OTM, offrs Mess from the existing over head lines complete all specified and as directed by Engineer-in-charge. Note:- Cables and materials for connection will be provided by occupant /user of the accn | - | Each Job | 22 | - |
| 7Material and labour for providing team of electrian amd helper/ labour, transport and T&P for locating the fault in HT/LT line in OH/UG Line/cable in by visual inspection recce of faulty area and rectify the fault by means of replacement of unservicible Jumpers / fuse wires / burnt lugs / MCCB etc. including restrain of broken/loose ACSR counductors / earth wire etc.and resume the power supply as early as possible. If cable is required to make temporary connection to resume the supply temporarly till the fault is rectify in HT/LT lines, the cable shall be given by MES from the AGE E/M store all as directed by Engineer-in-charge Area: The area to be covered are:- 66 KV Grid, Sub Stn No.3, AMN Dump Barsat and Baffle Range Dhablan Notes:-(i) Materials requried for fault repairs will be measured under relevant items included in BOQ. (ii) Contractor will depute the dedicated team and necessary transportation, he will completely responsible for all the safety aspects of his team. No dispute regarding safety of person would be entertain later on. If any mishappening occures during rectifaction of fault in HT/LT lines contractor will be fully liable to bear all the expenses of indls. (iii) Contractor will provide all set of T & P, communication device (Mobile Phone) to deployed persons, electrcian team for each sub station required for repair of HT/LT Electrical switch gear system including safety equipment such as All type of T&Ps (Bamboo ladders, screw drivers, wire/cable cutters with blades, multi meters, cutting plairs, torch lights etc) for routine maintenance and protection of the trademan incl safety equipment such as Hand gloves, Rubber boots, Sefety belt and helmets etc. | |||||
| 8 | Supply only the HT copper fuse wire of 5 Amps capacity. | - | Kg | 10 | - |
| 9Supply only the HT copper fuse wire of 10 Amps capacity. | |||||
| 10Supply only the HT copper fuse wire of 20 Amps capacity. | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
Tender362627.pdf
Tender Documents • 0.92 MB
BOQ_872406.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .