Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC TEHSIL SARKAGHAT P O RAKHOH VILL GADHANI SARKAGHAT MANDI HP 175024 | MANDI | HIMACHAL PRADESH | 175024 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹27.1 L+₹7.1 L (35.6%)Rejected-Finance | L2 | Rejected-Finance Being 2nd |
Tender Value
₹23.0 L
EMD Value
₹46,100
Closing Date
13 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
REPAIR AND MAINT OF AIR CONDITIONONG AND REFRIGERATION SYSTEM AT AF STATION SARSAWA UNDER GE (AF) SARSAWA
2023_MES_633073_1
8123/SAR-70/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SARSAWA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE(AF) SARSAWA
₹46,100
Yes
5 Mar 2024
16 Dec 2023
20 Jan 2024
16 Dec 2023
13 Jan 2024
30 Dec 2023
16 Dec 2023 - 30 Dec 2023
Amount
Periodical servicing/maintenance of floor monted Air Handling Unit (AHU) of capacity 8338 CFM by carrying following works :- (i) Removal of air filters (primary & secondary) from filter section, removal of dirt/dust partical by compressed air blower followed by washing under running tap water and refixing at site after complete dry . (ii) Removal of dirt/dust particals from aluminium fins of cooling coil by soft brushing followed by air blowing and cleaning of cooling coil by forced spray chemically (such as veni clean solution) all as directed by Engineer-in-Charge. (iii) Cleaning & removing of complete scale from bottom tray and drain pipe of AHUs as directed at site by the Engineer-in-Charge. (iv) Cleaning of drain pipe from AHUs tray to out side plant room manually as well as any de-scaling solution for draining. (v) Checking serviceability/tightening of fan motor V-belt, pulley block, fan blades assembly. (vi) Checking serviceability/tightening of AHU door lache and greasing/oiling.
All as per item srl no. 1 here in before but for floor mounted AHU of capacity 6043 CFM
All as per item srl no. 1 here in before but for floor mounted AHU of capacity 4738 CFM
All as per item srl no. 1 here in before but for celing suspended AHU of capacity 4200 CFM
Supply & fix in replacement washable synthetic non woven type pre air filter having efficiency 90% down to 10 Micron of size :- 610 x 610 x 50 mm
All as per item srl no. 5 here in before but 610 x 305 x 50 mm
Supply & fix in replacement box type bag filter of class MERV-13 washable :- 610 x 610 x 50 mm
All as per item srl no. 7 here in before but 610 x 305 x 50 mm
Supply and fix in replacement of fan belt (Model No A 1509 LP/A 58) for AHU blower motor Make : Fenner/Polyplus/Dunlop.
Supply and fix in replacement mecury in glass filled industrial thermometer 100mm dia SS of temp range 0-50 deg centigrade complete with syphon and isolating valve.
Supply and fix in replacement industrial type pressure gauge 100 mm dia SS of dual pressure range PSI & Kg/Sqcm (0-150PSI & 0-10.6Kg/Sqcm) complete with syphon and isolating valve.
Supply and fix in replacement of water flow switch having pressure rating 150 PSI, temp rating 100 deg centigrade, switching current rating 15Amp, 250V suitable for 25mm thread mounting.Make : Honeywell/Rapid Cool/Danfoss
Supply and fix in replacement hermetic type liquid line filter drier having MAP/MWP : 667 psig/46 bar Make : Honeywell/Rapid Cool/Danfoss
M&L for leakage detection in refrigeration line ckt of scroll chiller, plugging the same, nitrogen pressure testing, vacummizing and testing and commissioning complete
M&L for charging of refrigerant gas 407C complete all as directed by Engr-in-Charge. Make :Floron/Mrfron/DuPont/MPCL
M&L for charging of refrigerant gas 410 complete all as directed by Engr-in-Charge Make :Floron/Mrfron/DuPont/MPCL
M&L for charging of refrigerant gas R22 complete all as directed by Engr-in-Charge Make :Floron/Mrfron/DuPont/MPCL
Supply and fix in replacement scroll compressor Model No. SZ185S4RC suitable for water cooled chiller unit , Make : Danfoss
M&L for De-Scaling of 13 TR condenser cells & tubes unit by chemical circulation, rodding with wire brush to remove deposited scale in condenser including replacement of end plate gasket complete all as directed by Engineer-in-charge.
Supply and fix in replacement anti freeze thermostat in chiller line of adjustable range -30 to +15 deg C complete with stainless steel capillary tube of 2m long with bolted connector, IP44.
M&L for periodical servicing/maint of electric driven mono block pump set of rating 10HP comprising of :- (i) Removal of pump set from condenser line and foundation. (ii) Dismantling of motor end covers and taking out stator unit (iii) Removal of carbon/dust particals from motor stator winding by air blower followed by its chemical washing and varnishing complete as directed by Engineer-in-Charge. (iv) Greasing of bearings. (v) Checking & tightening of pump impeller. (vi) Re-fixing of pump set in position and making all connections and testing complete.
All as per item srl no. 21 here in before but chiller pump set of capacity 7.5HP
All as per item srl no.21 here in before but CT fan motor of capacity 5 HP
All as per item srl no. 21 here in before but blower motor of floor mounted AHU of capacity 5 HP
All as per item srl no. 21 here in before but blower motor of celing suspended AHU of capacity 2 HP
M&L for rewinding of squarell cage induction motor 3-phase, 415V, 2900 RPM, 10 HP with supper enamelled copper wire as per original gauge and pattern including removal, refixing, to & fro transportation, electrical connection at site and testing complete all as directed by Enginee-in-Charge.
All as per item srl no. 26 here-in-before but of capacitity 7.5HP
All as per item srl no. 26 here-in-before but of capacitity 5HP
All as per item srl no. 26 here-in-before but of capacitity 2 HP
Supply and fix in replacement cooling tower fan blade assembly 1500mm dia with 4 nos FRP blades and 01 no aluminium hub sitable for weldon make 125TR cooling tower.
Supply only cooling tower fan motor squirrel cage ,TEFC, IP-55, 3-phase, 415V, 50Hz, 960 RPM, 5 HP direct driven, extended shaft, flange mounted. Make : Oswal/Siemens/Swing
Supply and fix in replacement 125 TR Weldon make cooling tower fan motor FRP canopy with stands
Supply and fix in replacement PVC fillings of size 600x300x150mm suitable for Weldon make 125TR cooling tower Note for item srl no. 30 to 33 : Items to be procurred from OEM of cooling tower only.
M&L for removal of old unserviceable aluminium cable 3 core 16Sqmm
Supply, laying and testing of XLPE insulated PVC innersheathed GI wire armoured, heavy duty electric cable with copper conductor ,1100 volts grade cross sectional area 10 Sqmm, 3 core as per IS 7098(Part-1) 1988 amended up to date, laid on wall/celing/floor with appropriate GI clamps / fixing arrangement with termination with copper lugs as per standard practice.
Supply, laying and testing in replacement XLPE insulated PVC innersheathed GI wire/strip armoured, heavy duty electric cable with stranded aluminium conductor ,1100 volts grade cross sectional area 50 Sqmm, 3.5 core as per IS 7098(Part-1) 1988 amended up to date, laid on wall/celing/floor with appropriate GI clamps / fixing arrangement with termination with aluminium lugs as per standard practice.
Supply, laying and testing in replacement XLPE insulated PVC innersheathed GI wire/strip armoured, heavy duty electric cable with stranded aluminium conductor ,1100 volts grade cross sectional area 16 Sqmm, 4 core as per IS 7098(Part-1) 1988 amended up to date, laid on wall/celing/floor with appropriate GI clamps / fixing arrangement with termination with aluminium lugs as per standard practice.
Supply, laying and testing in replacement XLPE insulated PVC innersheathed GI wire/strip armoured, heavy duty electric cable with stranded aluminium conductor ,1100 volts grade cross sectional area 25 Sqmm, 4 core as per IS 7098(Part-1) 1988 amended up to date, laid on wall/celing/floor with appropriate GI clamps / fixing arrangement with termination with aluminium lugs as per standard practice.
Supply & fix in replacement cable PVC insulated unsheathed with stranded copper conductor of 06 Sqmm single core, green colour, FRLH, 1100 V grade as per IS 694, laid on wall/celing/floor with appropriate GI clamps / fixing arrangement with termination with copper lugs as per standard practice.
Supply and fix in replacement single phase preventer 415 V AC, 50 Hz with tripping provision on reverse phase,phase failiure, over/under voltage.
Supply and fix in replacement non skid synthetic rubber insulated mat 2mm thick for voltage upto 3.3 KV for electrical pupose as per IS 15652-2006 of size 2mx1m. Make : Vardhman/Jyoti/Safe Volt
Supply and fix in replacement digital energy meter dial size 96x96mm panel mounted with input 3P 3W/4W, 415V L-L, 1A/5A, 50 Hz, class 1.0, impulse const 4000 imp/KWh
S& F replacement of MCCB , 4 Pole,200 Amp,25 KA,415 Volt, 50 Hz, Adjustable thermal magnetic Protection unit all as specified and directed.
S& F replacement of MCCB , 4 Pole,125 Amp,25 KA,415 Volt, 50 Hz, Adjustable thermal magnetic Protection unit all as specified and directed.
S& F replacement of MCCB , 4 Pole,63 Amp 16 KA,415 Volt, 50 Hz, Adjustable thermal magnetic Protection unit all as specified and directed.
M& L for Earthing in replacement complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with the top edge of earth plate at depth not less than 1.5 Mtr below ground level connected to galvanised iron earth strip 32 X 6 mm by means of bolts, washers ,watering pipe 20mm dia, medium grade GI pipe,with welded funnel and wire mesh and 40mm dia medium grade GI pipe with fitting as protection pipe for strip from plate electrode to test point /plant/machineries etc. including concrete pit in PCC (1:3:6) type C-I having outer dimension 60cmx60cmx60cm and internal dimension 30cmx30cmx30cm, pre-caste RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia deformed bares @15 cm centre to centre both direction and 10 mm dia MS handle of suitable size charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in electrical plate No 3 of MES Schedule Part I and testing complete all as specified and as directed.
S & F in replacement 32mm x 6 mm GI strip earth continuity conductor or main earthing lead fixed to wall on wooden gutties or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing complete all as specified.
S & F in replacement 4.00 mm dia GI wire as earth continuity conductor or main earthing lead fixed to wall on wooden gutties or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing complete all as specified.
S& F in replacement of 100mm dia Butter Fly valves (Manualy operated) with CI Body, stainless steel disc, nitrile rubber seal & O ring,PN-16 Pressure rating for chilled water circulation.
S& F in replacement of 80mm dia Butter Fly valves (Manualy operated) with CI Body, stainless steel disc, nitrile rubber seal & O ring,PN-16 Pressure rating for chilled water circulation.
S& F in replacement of 50mm dia Butter Fly valves (Manualy operated) with CI Body, stainless steel disc, nitrile rubber seal & O ring,PN-16 Pressure rating for chilled water circulation.
Supply and fix in replacement Y-strainer CI body with SS strainer for water circuit complete with all fittings, jointing materials etc suitable for 100 mm dia.
Supply and fix in replacement Pot -strainer CI body with SS strainer for water circuit complete with all fittings, jointing materials etc suitable for 100 mm dia.
Supply and fix in replacement gun metal gate valve for water circuit complete with all fittings, jointing materials etc suitable for 20 mm dia.
Supply and fix in replacement gun metal gate valve for water circuit complete with all fittings, jointing materials etc suitable for 25 mm dia.
Supply, assembly and erection in replacement of GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessoried such as corner, Cleat. Carriage bolt, Gasket and appropriate sealat on longutudinal joints etc complete of size 24 Guage all as specified and directed by Engr-in-charge. Notes : (i) Duct shall be fabricated from galvanised sheet steel zic coated having zinc coating 120 gm/sqm total conforming to IS-277-2003.
Supply and replacement of copper tubing 1/4 " (as per sample) at installation all as directed by Engr-in-charge.
Supply and replacement of brass flow nuts 1/4 " to 5/8 " (as per sample) all as specified and directed.
S&F aluminium powder coated bird screen with front side lovers and back side jali for free flow air and tripping big size mosquitto and particles comple all as specified and directed.
Supply & fix in replacement Electronic starting circuit relay circuit for 16.5 TR package type AC (As per sample) complete all as specified and as directed. complete all as specified and directed by Engr-in-Charge. Make C&S/L&T/ABB
Supply & fix in replacement Electronic starting circuit relay circuit for 8.75 TR compressor (As per sample) complete all as specified and as directed. complete all as specified and directed by Engr-in-Charge. Make C&S/L&T/ABB
Supply & fix in replacement sealed unit compressor of cap 5.5 TR suitable for package type AC complete all as specified and as directed by Emgr-in-Charge.Note : Repaired and repainted compressor not accepted only gnuine compressor are accepted. with test report and year warranty certificate from OEM. Make :Sanyo/Copeland/Mitsubishi
Supply & fix in replacement sealed unit compressor of cap 4.5 TR suitable for package type AC complete all as specified and directed by Engr-in-Charge.Note : Repaired and repainted compressor not accepted only gnuine compressor are accepted. with test report and year warranty certificate from OEM. Make :Sanyo/Copeland/Mitsubishi
M&L for replacement of compressor oil suitable for danfoss make scroll chillers
Supply and Fix in replacement accoustic insulation lining on wall rooms with 50mm thick, 32 Kg/m3, rigid bonded fibreglass. Accoustic insulation shall be fixed in 610mm x 610mm frame work made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fibre glass tissue paper and finished with 0.8 mm thick fixed on all horizontal and vertical joints by means of screws etc. complete as directed by Engr-in-Charge.
Demolation Mud in roofs, any thicknes, any material including plastering, brick bats, existing tretement and cleaning (Whether full thickness removed or only or part there of) etc in all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 km but not exc 1.5 km complete all as specified & directed by Engr-in-Change.
M&L for providing cement concrete in thpe B0 1:2:4 (using 12.5mm graded crushed stone aggregate)as in roof padding, laid to (consolidated thickness 65mm or less) as leveling course, laid and compacted in min slope 1:30 over roof complete all as specified & directed by Engineer-in-Charge.
M&L screed laid 15mm thick in CM 1:4 as in roof over green concrete surafce finished even and smooth using Lequid WPC Complete all as specified.
M&L for roof treatement using APP based polymeric membrance minimum weighing not less than 3kg/Sqm black finish (wt. not less than 150 gms/Sqm) laid over compatible bitumen primer @0.30 liters per sqm and bitumen 85/25 @ 1.20 Kg per Sqm with help of torching with a proplyne or a butane gas using torch with minimum overlap of 75mm at side and 100mm at ends and sealing including appliying a coat of bitumen primer & bitumen 85/25 applied hot all as per manufacturer instructuions. For parapet in a groove (No separete payment will be made and mesurement will be done for horizontal surfaces) including applying a coat of heat repallant bitumen aluminium paint @ 0.1 liter per Sqm on top of treated surface of roof complete all as specified and directed.
S&F in replacement ball bearing 6205 Make : SKF/NBC/TATA
S&F in replacement ball bearing 6203 Make : SKF/NBC/TATA
S&F in replacement terminal plate suitable for 10HP/7.5 HP motor
M&L for remetalling of bearing housing in 5HP to 10 HP rating motor end cover with machineble welding rod lathe work to make size as per inner dia of bearing and polishing complete all as directed by Eng-in-Charge
M&L for remetalling of bearing seat on shaft of 5HP to 10 HP rating motor with machineble welding rod lathe work to make size as per inner dia of bearing and polishing complete all as directed by Eng-in-Charge
Supply and fix in replacement Contactor kit for ML – 1.5.
Supply and fix in replacement Contactor kit for ML – 2.0
Supply and fix in replacement contactor coil for ML-1.5 .
Supply and fix in replacement contactor coil for ML-2.0
Supply and fix in replacement Contractor4-pole 415V AC as per MCX 13
Supply and fix in replacement Contractor 4-pole 415V AC as per MCX 22
M&L for thermal insulation coating on HVAC duct/pipe line by using starbond chemical UV,water and abration resistanant as per following method: Apply a tack coat of starbond , imbed glass cloth smoothly into the wet coating, apply two finish coat of starbond in such away that 2nd coat is applied only after Ist coat is fully cured.
Mild steel for MS work confirming to Fe-410-O or Fe-310-O as in hanges, supports chaneel, clamps etc including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of syntheic enamel paint over a coating of red oxide primer.
ISHWAR ELECTRICALS AND PROCESS SERVICES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .