Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.0 L+₹90 (0.03%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹3.0 L+₹120 (0.04%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹3.0 L
EMD Value
₹6,043
Closing Date
28 Feb 2026, 3:00 pmClosed
PRODHAN
VILL-NAKKATI,P.O-PUSHNADANGA,P.S-KOTWALI,DIST-COOCHBEHAR,PIN-736134
Implement of safe drinking water point with soakpit at Gouranga Bazaar Swasan ghat at Haribhanga mouza JL no 229 Booth No-132 under Haribhanga Gram Panchayat.
2026_ZPHD_1012828_1
NIT NO-15/HARIBHANGA/2025-2026,SL NO-01 Dt-18/02/2026
Open Tender
CIVIL AND ELECTRICAL WORKS
Percentage
HARIBHANGA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹6,043
7 Oct 2026
23 Feb 2026
2 Mar 2026
23 Feb 2026
28 Feb 2026
23 Feb 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete | 3.84 | cum | 119.27 | ₹457.76 |
| 1.02 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) | 0.77 | CUM | 77.54 | ₹59.55 |
| 1.03 | Single brick flat soling of picked jhama brick including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. | 11.8 | sqm | 322 | ₹3,799.6 |
| 1.04 | Cement concrete with 30 mm down graded shingles excluding shuttering. In ground floor.a. 6:3:1 proportion. | 0.55 | cum | 3,393 | ₹1,862.76 |
| 1.05 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor
as per relevant IS codes. b. River bazree. | 2.18 | cum | 4,069 | ₹8,886.7 |
| 1.06 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction. | 1.37 | qntl | 6,241.9 | ₹8,551.4 |
| 1.07 | Hire and labour charge for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, columns, lintels curved or staight including fitting fixing and striking out after complection of works. (upto roof of ground floor) | 9.22 | sqm | 205 | ₹1,890.1 |
| 1.08 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. | 8 | sqm | 34 | ₹272 |
| 1.09 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. a) for depth up to 150.00m. for 50mm. dia. tube well top enlargement of 100mm dia. | 30 | m | 287 | ₹8,610 |
| 1.1 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. 50mm dia boring etc | 24 | m | 426 | ₹10,224 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.92 MB
BOQ_2487782.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .