| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC | ₹5.6 L | L1 | Accepted-AOC AOC |
| 2 | L2₹6.7 L+₹1.1 L (19.9%)Rejected-Finance 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | ₹6.7 L+₹1.1 L (19.9%) | L2 | Rejected-Finance Higher than L1 |
| 3 | L3₹6.9 L+₹1.3 L (23.0%)Rejected-Finance SRINIKETAN ROAD BOLPUR BIRBHUM 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | ₹6.9 L+₹1.3 L (23.0%) | L3 | Rejected-Finance Higher than L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical valid short fall documents not submitted |
| Sl No | Description | Qty | Unit | MILLENNIUM AIRCON L2 | RAMKRISHNA ELECTRONICS L3 | NEW MODERN COOLING L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing & Commissioning of 1.5 tr. split type AC machines having Cooling Capacity range (5.2 kw - 5.3 kw), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.5 to 3.99), Air flow range CFM (560-600), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments (Make- Mitsubishi Electric/Daikin/Carrier / Voltas/ Blue Star /Hitachi ) | 9 | each | 53,000 ₹4,77,000 Lowest | 75,000 ₹6,75,000 | 56,000 ₹5,04,000 |
| 2.00 | Supply and laying of regriperent copper pipe minimum thickness 1.15 men liquid linie 1/4" dia and gas line 5/8" dia (Make- Ryoku/Mandeep) and insulation of copper pipe by nitrile rubber insulation tube of minimum thickness 19mm (Make - Araflex/ Acoflex) incl. of S&F of 4 core 2.5 sqm PVC insulated copper wire for connecting indoor and outdoor unit also rapping insulation and copper wire with GKB Gold rapping tape. | 245 | mtr. | 199 ₹48,755 | 1 ₹245 Lowest | 100 ₹24,500 |
| 3.00 | Supply & laying fixing drain Water piping work out of PVC pipes Medium ISI of 25mm With 6mm thick nitrile rubber insulation & Necessary clamp and other accessories as required. | 196 | mtr. | 50 ₹9,800 | 1 ₹196 Lowest | 113 ₹22,148 |
| 4.00 | Consmction of MS structure for installation and future maintenance AC's Outdoor units made with MS C Chanel 50x50x75 mm 6mm thick, MS angle 50x50x50mm thick and 40mmx6mm thick MS strip incl.of grouting in wall and painting as per the direction of EIC, Drawing and design to be paved by EIC | 540 | kg | 250 ₹1,35,000 | 1 ₹540 Lowest | 19 ₹10,260 |
| 5.00 | 415V, 300 amp TPN switch with HRC fuse
(For upto 3 days) | 7 | Item | 300 ₹2,100 | 2,000 ₹14,000 | 1 ₹7 Lowest |
Tender Value
₹7.0 L
EMD Value
₹14,021
Closing Date
10 Jan 2025, 2:00 pmClosed
EE_KCED_PWD
Khadya_Bhawan_11A_Mirza_Ghalib_Street_Block_A_3rd_Floor_Kokata_700087
SITC of split type Room Air Conditioners Machine with necessary EI work in the State Legeslators Hostel Office Campus, Kolkata
2024_PWDE_787889_1
WBPWD/EE/25/IR/T/KCED/I of 2024-25(3rd call)
Open Tender
Electrical Work/ Equipment
Item Rate
30 days
MLA HOSTEL OFFICE CAMPUS
Please refer Tender documents.
4 documents required · 4 mandatory
₹14,021
Office_of_EE_KCED_PWD
11 Sept 2026
19 Dec 2024
13 Jan 2025
19 Dec 2024
10 Jan 2025
27 Dec 2024
26 Dec 2024
Amount
Supply, Installation, Testing & Commissioning of 1.5 tr. split type AC machines having Cooling Capacity range (5.2 kw - 5.3 kw), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.5 to 3.99), Air flow range CFM (560-600), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments (Make- Mitsubishi Electric/Daikin/Carrier / Voltas/ Blue Star /Hitachi )
Supply and laying of regriperent copper pipe minimum thickness 1.15 men liquid linie 1/4" dia and gas line 5/8" dia (Make- Ryoku/Mandeep) and insulation of copper pipe by nitrile rubber insulation tube of minimum thickness 19mm (Make - Araflex/ Acoflex) incl. of S&F of 4 core 2.5 sqm PVC insulated copper wire for connecting indoor and outdoor unit also rapping insulation and copper wire with GKB Gold rapping tape.
Supply & laying fixing drain Water piping work out of PVC pipes Medium ISI of 25mm With 6mm thick nitrile rubber insulation & Necessary clamp and other accessories as required.
Consmction of MS structure for installation and future maintenance AC's Outdoor units made with MS C Chanel 50x50x75 mm 6mm thick, MS angle 50x50x50mm thick and 40mmx6mm thick MS strip incl.of grouting in wall and painting as per the direction of EIC, Drawing and design to be paved by EIC
415V, 300 amp TPN switch with HRC fuse (For upto 3 days)
MILLENNIUM AIRCON (BID ID -5928953)
RAMKRISHNA ELECTRONICS (BID ID -5934432)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .