MAJOR ANIRUDDHA SUBBA
DRDO Complex, CV Raman Nagar PO, Bangalore 560 093
REPAIRS AND MAINTENANCE OF CENTRAL PACKAGE TYPE AC PLANT AT GTRE UNDER GE I R AND D EAST BANGALORE
2026_MES_795813_1
8781/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D EAST BANGALORE
CLASS D CATEGORY c(i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D EAST BANGALORE
₹96,000
Yes
3 Nov 2026
3 Nov 2026
25 Nov 2026
3 Nov 2026
23 Nov 2026
17 Nov 2026
3 Nov 2026 - 16 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for periodical maintenance of Central AC plants of any capacity like checking for proper electrical connection, checking/tightening of V belt, checking refrigerant pipe line, arresting refrigerant gas leakage if any, checking of proper functioning of electrical control panel, checking/cleaning of pre filter (twice in a month), and routine checking to ensure smooth running of Central AC plants complete all as specified and as directed:-
NOTE :- Replacement of compressors, spares, condenser fan motors, blower and motor, solenoid valves, drain pumps, refrigerant, Oil, etc, if required shall be measured and paid separately under relevant items of this Schedule. | 9 | EACH JOB PER MONTH | - | - |
| 1.01 | (a) Make: ACCELSMC 4-65 installed at 7A-7B Bldg 3 X 15 TR Central AC plant (01 No as stand By)
(b) Make : BATLIBOI Make at IC Lab 3 X 15 TR Central AC plant (01 No as stand By)
(c) Make Carrier installed at New assembly hanger 3 X 100TR Chiller plant (01 No as stand By)
(d) Make : Bldg No 2 & 5 AC Plant (1 X 15 TR Central AC plant)
(e) Make : Bldg No 3D CM AC Plant (3 X 15 TR Central AC plant (01 No as stand By)
(f) Make : Bldg No 8 A Test Bed 3 X 14 TR Central AC plant (01 No as stand By)
(g) Make : Bldg No 9 2 X 28 TR Central AC plant
(h) Make : Machine Shop IV 1 X 14 TR Central AC plant
(j) Make : MERF Bldg 2 X 28 TR Central AC plant
(l) Make : Machine shop V (GTRE) 2 X37.5 TR Central AC plant | - | - | - | - |
| 2 | Material and labour for periodical maintenance of package AC plants of any capacity like checking for proper electrical connection, checking/tightening of V belt, checking refrigerant pipe line, arresting refrigerant gas leakage if any, checking of proper functioning of electrical control panel, checking/cleaning of pre filter (twice in a month), cleaning of out door unit with soap solution and routine checking to ensure smooth running of package AC plants complete all as specified and as directed:-
Note: Replacement of compressors, condenser fan motors, Blower and motor, PCBs, Solenoid valves, Drain pumps, Refrigerant, Oil, etc., if required shall be measured and paid separately under relevant items of this Schedule. | 9 | EACH JOB PER MONTH | - | - |
| 2.01 | (a) 2 X10 TR Package type (High mass Bldg)
(b) 3 X5 TR Package type (Cell -03)
(c) 3 X10 TR Package type ( Calibration Lab)
(d) 2 X8.5TR Package type ( Material Group)
(e) 2 X15 TR Package type ( Auditorium)
(f) 2 X10 TR Package type (98 Building)
(g) 2 X10 TR Package type ( Welding Shop) | - | - | - | - |
| 3 | Preventive maintenance for ductabe package type AC plants of following capacity consisting of regular inspection and checking of all electrical control panels, refrigerant gas leak testing, inspection/ checking /cleaning of distributions duct systems, checking and cleaning of all electrical motors, belts and fan blades, proper alignment, replacement of unserviceable refrigerant pipe line insulation including rectification of any faults as occurred/replacement of minor parts as required. Cleaning of cooling coil with Alkaline Based cleaner (non-Acid Based) at 2 x 8.5 TR with 1 x 8.5 TR standby at Super computer Bldg No 10
NOTE FOR Sl ITEM No. 1 to 3:
(i) The rates quoted by the contractor shall be deemed to be included for the works as specified here in below. | 9 | EACH JOB PER MONTH | - | - |
| 3.01 | (ii) Spare parts required to be replaced will be measured and paid separately.
(iii) The rate quoted by contractor deemed to be included the cost for deploying a suitable mechanic to checking of functioning of AC Plant for its proper functioning and obtaining users signature in maintenance register/ maintenance schedule sheets and putup the same to Engr-in-Charge.
(iv) The contractor will be responsible to keep the plants room area and surrounding area neat & clean regularly for inspection.
(v) The rate quoted shall be inclusive of the cleaning material / cotton waste etc.
(vi) Quoted rate is to be deemed the charges of necessary boom lift.
(vii) The contractor shall depute supervisor on all working days in MES complaint cell for attending the complaint regarding the Air Conditioner. | - | - | - | - |
| 4 | Material and labour for Evacuating of refrigerant gas from the system into the empty cylinder for up to 100 TR capacity central/Package type AC plants, leak testing of the plant with dry nitrogen gas (N2) pressure by separating the entire system like low side, high side compressor condensers and rectifying the leakage vacummizing re-charging of evacuated refrigerant gas and testing complete all as directed.
Note: Topping up of gas will be measured and paid separately. | 15 | EACH JOB | - | - |
| 5 | Material and labour for disconnecting compressor of up to 100 TR from the system for maintenance/ servicing after closing by suitable dummy plates on suction and discharge valves and opening the compressor & removing of all internal parts, cleaning of the all parts thoroughly, grinding and polishing of crank shaft, including replacement of thrust collers, spring washers and nut bolts etc, and re-fixing back all parts, to the compressor and removing of the dummy plates, leak testing of the compressor, testing and commissioning of the compressor all as directed for following makes :- | 25 | EACH JOB | - | - |
| 5.01 | (i) ACCELSMC 4-65 installed at 7A-7B Bldg 3 X 15 TR Central AC plant (01 No as stand By)
(ii) BATLIBOI Make at IC Lab 3 X 15 TR Central AC plant (01 No as stand By)
(iii) Carrier installed at New assembly hanger 3 X 100TR Chiller plant (01 No as stand By)
(iv) Bldg No 2 & 5 AC Plant (1 X 15 TR Central AC plant)
(v) Bldg No 3D CM AC Plant (3 X 15 TR Central AC plant (01 No as stand By)
(vi) Bldg No 8 A Test Bed 3 X 14 TR Central AC plant (01 No as stand By)
(vii) Bldg No 9 2 X 28 TR Central AC plant
(viii) Machine Shop IV 1 X 14 TR Central AC plant
(ix) MERF Bldg 2 X 28 TR Central AC plant
(x) Machine shop V (GTRE) 2 X37.5 TR Central AC plant
NOTE :- The quoted rate deemed to included for minor spares. | - | - | - | - |
| 6 | Supply and charging of compressor oil servo friz F 68 after draining out old/unserviceable compressor oil complete all as specified and as directed.
Make of oil : INDIAN OIL or equivalent in BPCL/HPCL | 120 | LITRE | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
8781Tender.pdf
Tender Documents • 0.81 MB
BOQ_894154.xls
BOQ • 1.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .