| 4 | l4₹76.2 L+₹9.0 L (13.5%)Rejected-Finance | ₹76.2 L+₹9.0 L (13.5%) | l4 | Rejected-Finance Reject |
Tender Value
₹75.9 L
EMD Value
₹1.5 L
Closing Date
30 Sept 2021, 3:00 pmClosed
Incharge Civil
Verka Head Office
Interiors works Puff panelling, Air conditioning, internal electrification Fire fighting etc for setting-up State Central Laboratory NABL accredited at Verka Mohali Dairy
2021_Coop_71040_1
PSF/Civil14272Mohali
Open Tender
Civil Works
Item Rate
180 days
Verka Head Office
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹1.5 L
21 Oct 2021
4 Sept 2021
1 Oct 2021
4 Sept 2021
30 Sept 2021
4 Sept 2021
Amount
Providing and fixing of 60mm thick Powder Coated PUF insulated Wall Panel with 0.60mm thick GPSP (Make-TATA) of Galvanisation in between 340-425 GSM Duly Powder Coated in Interpon Ackzonoble Pure Polyester Powder of Exterior Grade (RAL-9002) with Coating thickness in between 60-80 microns with FR Grade PUF Density 44 Kg/m3 ±5% in metalic tongue and Groove joint system,cut to size, with no loading of wastage with additional 90º bends in Male & Female groove to have proper sealing, Strength & Air Tight joints Panel to Panel,CFC free & Ozone friendly.(Pentane Based) including top/bottom u Channels and inner falshing complete in all respect as directed by E-in -C.
Providing and fixing of 60mm thick Powder Coated PUF insulated View Panel with 0.60 mm thick GPSP (Make-TATA) of Galvanisation in between 340-425 GSM Duly Powder Coated in Interpon Ackzonoble Pure Polyester Powder of Exterior Grade with Coating thickness in between 50-80 microns with FR Grade PUF Density 44 Kg/m3 ±10% in metalic tongue and Groove joint system, cut to size, with no loading of wastage with additional 90º bends in Male & Female groove to have proper sealing, Strength & Air Tight joints Panel to PaneL with 5mm thick clear Toughened Double Glazed Glass 1000x1000mm having 25mm thick Black Boarder along the periphery with SS-304 Grade, Concealed Channel duly sealed with 3M Tape and Dow Corning Silicon Sealant.including top/bottom u Channels and inner falshing complete in all respect as directed by E-in -C.
Providing and fixing of 50mm thick Powder Coated PUF insulated Ceiling Panel with 0.60mm thick GPSP (Make-TATA) of Galvanisation in between 340-425 GSM Duly Powder Coated in Interpon Ackzonoble Pure Polyester Powder of Exterior Grade (RAL-9002) with Coating thickness in between 60-80 microns with FR Grade PUF Density 44 Kg/m3 ±5% in metalic tongue and Groove joint system,cut to size, with no loading of wastage with additional 90º bends in Male & Female groove to have proper sealing, Strength & Air Tight joints Panel to Panel,CFC free & Ozone friendly.(Pentane Based) including aluminum powder coated complete hanging trus with tie road wall angel for cieling complete in all respect as directed by E-in -C.
Providing and fixing of 40mm thick Powder Coated PUF insulated Cladding Panel with 0.60mm thick GPSP (Make-TATA) of Galvanisation in between 340-425 GSM Duly Powder Coated in Interpon Ackzonoble Pure Polyester Powder of Exterior Grade (RAL-9002) with Coating thickness in between 60-80 microns with FR Grade PUF Density 44 Kg/m3 ±5% in metalic tongue and Groove joint system,cut to size, with no loading of wastage with additional 90º bends in Male & Female groove to have proper sealing, Strength & Air Tight joints Panel to Panel,CFC free & Ozone friendly.(Pentane Based) including top/bottom u Channels and inner falshing complete in all respect as directed by E-in -C.
Providing and fixing of 40mm thick Powder Coated PUF insulated View Panel with 0.60 mm thick GPSP (Make-TATA) of Galvanisation in between 340-425 GSM Duly Powder Coated in Interpon Ackzonoble Pure Polyester Powder of Exterior Grade with Coating thickness in between 50-80 microns with FR Grade PUF Density 44 Kg/m3 ±10% in metalic tongue and Groove joint system, cut to size, with no loading of wastage with additional 90º bends in Male & Female groove to have proper sealing, Strength & Air Tight joints Panel to PaneL with 5mm thick clear Toughened Double Glazed Glass 1000x1000mm having 25mm thick Black Boarder along the periphery with SS-304 Grade, Concealed Channel duly sealed with 3M Tape and Dow Corning Silicon Sealant. including top/bottom u Channels and inner falshing complete in all respect as directed by E-in -C
Supply of Clean Room doors shall be of 44mm leaf thickness, 0.80mm GP/SP powder coated metal sheets on both sides filled with 40±2 kg/m³ density PU foam. The door fitted with 1.2mm GPSP Powder coated Chowkhat, SS hinges, Dead Lock, Door closer,D type SS handle/SS push plate, Concealed Tower Bolt for double leaf door, SS kick plate push side upto 300mm height & door bottom drop seal. The door come with a standard view window of size 400 X 600mm.
Size 1000x2400mm (Single Leaf Door)
Size 1200x2400mm (Double Leaf Door)
Size 1500x2400mm (Double Leaf Door)
Providing and fixing of Alunmium powder coated coving R-50 with coving back channel for wall to wall , wall to ceiling joint for the ease of cleaning of edges. Complete in all respects as directed by E-in-C..
Providing & fixing 3mm thick ACP Sheet high class ISI marked complete in all respect as per the directions of Engineer-in-charge.
Providing and fixing of false ceilings at all heights of Gypsum board 12.5 mm thick as per the standard norms laid by India Gypsum Ltd., which includes providing and fixing G.I. per Perimeter channel of size 27 mm & 0.5 mm thick having one glace of 20mm and another flange of 30mm alongwith perimeter of the ceiling, screw and rawl plugs. Then suspended G.I. intermediate channels of size 45 mm x 9mm thick with two gauges of 1.5mm each from the soffit at 1200mm center with still G.I. hangers of which 25mm x 5mm thick fixed to soffit with G.I. cleat and steel expansion fasteners ceiling section of 5mm thickness having knurled wedge of 51.5mm channel with the help of connecting to clips and in direction perpendicular to the intermediate channel at 45mm centre , 12.5mm taped adge Gypsum board to be screw fixed to ceiling section with 25mm drywell screw at 230mm centers. Screw fixing to be done mechanically. The taped and the square edges of the board are to be jointed and finished to flush finish with requisite jointing compound, paper tapes, finisher and primer, suitable for Gypsum plaster boards . Cutouts have to be made for light Fittings, Ac grills diffusers etc. with the frame of perimeter channels as per designs. The rate shall include making good the damages with cement mortar. Complete as per drawings, specifications and to the entire satisfaction of Architech and E-in-C.
Providing and fixing of false ceiling at all heights of 600mmx600mmx15mm ARMSTRONG Mineral Fibre ceiling tiles of type DUNE RH-99 laid in grid system. The frame work comprise of made of Gl, 120 GSM coating with minimum 0.3mm thickness main runner spaced at 1200mm centre to centre securely fixed to the structural soffit by approved hangers at 1200mm maximum centres. Hangersa (Gl wire of 4mm dia) to be fixed by approved roof plug, level adjusters and screw etc. The last hanger at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees (with double stiching) to be interlocked between main runners at 600mm centres to form 1200x600mm modules. Cut across tees with V grooves longer than 600mm to be supported independently. 600x600mm modules to be formed ay fitting 600mm long flush fitting cross tees centrally between the 1200mm cross tees. Perimeter trim to be Armstrong wall angle secured to walls at 450mm maximum centres complete in all respects as per specifications and to the entire satisfaction of E-In-C.
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. Wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:-
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm,1100volts grade. with single control switch.
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm,1100volts grade complete without control switch.
Wiring Fan point- controlled by one switch in PVC insulated copper conductor single core FR cable (ISI marked to the approval of E-in-C). overall 1.5 sq. mm, 1100volts.
Wiring call-bell point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with bell push and electronic buzzer 230 volts AC (including the cost of bell push, electronic buzzer & powder coated concealed metal box for electronic buzzer).
Wiring 3 pin 6 Amp. wall socket (Shuttered) point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FR cable (ISI marked) overall 1 sq. mm, 1100volts grade.
Wiring 3 Pin 6 Amp. Plug control comprising wall socket(shuttered) and switch including bonding to existing earth with PVC insulated copper conductor single core FR cable (ISI marked) overall 1 sq. mm, 1100volts grade complete.
Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch.
Wiring TV sockets and Telephone socket points in powder coated/anodized concealed metal boxes recessed in wall/under floor required for suitable number of modules, for having TV sockets, Telephone sockets RJ11 & RJ45 (one module) etc., and covered with Frame Plate etc., & including the cost of required number of modular TV sockets, Telephone sockets RJ11 & RJ45 (one module) and other petty material etc. including the cost of cutting and filling up of chases complete as directed by the E-in-C.
a) Wiring of TV socket point (one module) including T.V. Jack .
b) Wiring Telephone socket point (one module) including Telephone Jack RJ - 11.
c) Wiring Computer socket point (one module) including Computr Jack RJ -45.
Supplying and erection of P.V.C. insulated single core FR copper conductor cable (ISI marked - to the approval of E-in-C) left bare in pipe or casing of suitable size, excluding the cost of supply and erection of pipe or casing. Complete in all respects. Note:- (Extra rate will be payable only beyond the individual point’s control panel/ board to main D.B. panel)
a) PVC insulated copper conductor single core FR cable overall 1 sq.mm, 1100volts grade.
b) PVC insulated copper conductor single core FR cable overall 1.5 sq.mm, 1100volts grade.
c) PVC insulated copper conductor single core FR cable overall 2.5 sq.mm, 1100volts grade
d) PVC insulated copper conductor single core FR cable overall 4.0 sq.mm, 1100volts grade
Supplying and erection of Miniature circuit breaker (MCB’s) single pole 6 to 32 amp (Breaking capacity 10 kA, Curve-C) suitable for 240/415 volts 50 cycles AC supply, to be fixed in the new/ existing MCBD’s including necessary connections, testing and commissioning etc. complete in all respects as directed by the E-in-c. Make Havells/ Legrand/ Schneider or equivelant approved
a) 6 to 32 A SP MCB
b ) MCB Double Pole 6-32amp. (10kA, Curve-C)
c ) MCB Four Pole 6-32amp. (10kA, Curve-C)
d ) MCB Four Pole 40amp. (10kA, Curve-C)
Supplying and Erection of heavy gauge PVC conduit pipe, fire retardant for wiring purpose - 25mm dia (ISI marked recessed in wall/ on surface) of an approved quality. Including the cost of bends, sockets, inspection boxes etc. complete in all respects as directed by the E-in-C. Note:- (Extra rate will be payable only beyond the individual points control panel/board to main D.B. panel).
Supply and fixing single pole blanking plate in the switch board complete as directed by the E-in-C
Supply and laying PVC DLP channel 100 x50mm consisting of internal angle, external angle, Tee, cable divider, cable retainer end cap and cover etc. with all calping and fixing accessories for networking cable system complete in all respects as directed by the E-in-C.
Supply and fixing of call bell / buzzer A.C. 230V, Single Pole. Make Anchor/Havel/ or equivalent approved by the E-in-C.
Supply and erection of PVC flexible pipes (fire retardant) for wiring purposes including bends, inspection boxes etc., where necessary including other petty material as per PWD General Specifications 2010 complete in all respects as per site requirements.
a) Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) On Surface
b) Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) On Surface
Supply and laying of voice / data wires in existing conduits / raceways and terminating with RJ-45 terminals for data & RJ-11 terminals for voice as indicated on site / drawing.
a) Cat 6 cable for voice outlet for internet facility and networking station and terminating with RJ-45 and RJ -11 terminals for networking and voice data. Make :- Legrand/Systimax or equivalent approved .
SUPPLY AND FIXING OF LIGHTING LUMINARIES CONSISTING OF LIGHTING FIXTURES, TUBE ROD / CFLS/LED LAMP AND ALL INTERCONNECTED WIRING. MAKE PHILIPS/WIPRO /HALONIX OR EQUIVALENT MAKE APPROVED BY THE E-IN-C BEFORE FIXING, DETAILS GIVEN UNDER:- Supply and fixing of recessed mounted600x600mm, 35 Watt high power led fixture having256 nos. of led, p.f. >0.9, view angle 120 deg.,smps based constant driver and complete as per manufacturer's specifications, drawings, and to the entire satisfaction of Architect and E-in-C.
Supply and Erection of Green LED – 900 ( 15 watt ) light panel (Cool white) Philips make complete in all respects as directed by the E-in-C.
SUPPLY AND FIXING CEILING FANS - DOUBLE BALL BEARING TYPE MAKE HAVELS/USHA/BAJAJ ULTIMA/CROMPTON HIBREEZE MODELS Supply and fixing of 48” (1200mm) sweep ceiling fan, double ball bearing suitable for operation on 230 volts, 50 Hz single phase A.C. supply complete and with necessary down rod with fan regulator etc. , complete in all respects, as directed by the E-in-C.
Supply and fixing of wall mounted cabin fan 450 heavy duty OSE type with tilt angle adjustment having 3 speeds including built-in regulator suitable for operation on 230 volts, 50 Hz single phase A.C. supply complete in all respects as directed by the E-in-C. make: Havells/USHA/Crompton Hibreeze model.
SUPPLY AND FIXING - EXHAUST FANS DOUBLE BALL BEARING, TYPE POWDER COATED WITH SUITABLE LOUVERS MAKE HAVELS/USHA/BAJAJ ULTIMA/CROMPTON HIBREEZE MODELS
a) Supply and fixing exhaust fan 12" (300mm sweep)
b) Supply and fixing exhaust fan 18" (450mm sweep)
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc. GROUP-A: (Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA), Hager.
a) Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's,12 way each complete in all respects.
b) Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's, 8 way each complete in all respects.
c) Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's, 4 way each complete inall respects.
d) Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's, 8 way each complete in all respects.
LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS):
Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel.
The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc.n..
The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.
Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work .Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports.
LT Panel enclosure having space for 1No.Incomer MCCB 200Amp. and 4Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 1000 x 300mm)
Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
Supply, Installation,Testing & Commisioning of Microprocessor based 1 loop fire alarm control panel fully networkable,expadable with each loop capable of taking 99 devices and 99 modules , 1 line x 40 character alpha-numeric liquid crystal display.The panel shall be soft addressable type. The Panel should be able to store 500 log events in it's Memory. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier, Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, option to have built in printer to log all fire or fault events complete in all respects, integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification VDS & CNBOP approved.
Supply, Installation, Testing & Commissioning of Analog Addressable Intelligent multisensor detector, soft addressable Photo thermal ( Dual Optical with Forward and backward scattering & One Thermal Chambers) type with inbuilt fault isolator complete with base as required
Supply, Installation, Testing & Commissioning of Addressable Manual Call Point soft addressable type with in built fault isolator complete as required
Supply, Installation, Testing & Commissioning of Addressable transponder/ Monitor Modules 4 input and 2 output for monitoring flow switches/Fire exit doors etc complete as required
Supply and pulling of 2 x 1.5 sq.mm copper armoured FR cable
Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. 6Kg Capacity
Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. 4.5 g Capacity.
Providing and fixing of FIRE EXTINGUISHER, Mechanical Foam Type 9 ltr IS: 15683 Stored Pressure type complete with all accessories as per Manufactures Specification. ISI Mark of approved make complete in all respect. Note :- The Successful tenderer shall obtain N.O.C. from the concerned Fire Officer, in regard to fire fighting system.
Supplying, installation, testing, and commssioning of MISUBISHI, or Equivalent VRV/VRF system of based on digital/vapour njection/inverter scroll technology complete with indoor and outdoor units with individual controller and with refrigerant piping, control cabling suitable for ambient conditions and as per detail given inspecifications and having following items : Outdoor Unit SITC of aircooled variable refrigerant volume modular type airconditioning system with R410a refrigerant suitable for 415±10%, 50 cycles.The unit shall consist of indoor and outdoor units with individual controller Modular type outdoor units equipped with highly efficient inverter type 100% inverter scroll type compressors with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and Outdoor unit suitable for Cooling & Heating of following capacitites: SITC of Distribution Board, isolators, Cables, earthing etc. of suitable ratings for outdoor unit. *The ODUs shall be placed on MS Channel 100 x 50 mm by contractor duly painted &grouted as per drawings. The contractor/ company must quote as per below mentioned capacities as minimum.
a) 20 HP outdoor unit including Header
b) 18 HP outdoor unit including Header
Indoor Air Handling Units :- Supplying, installation, testing, and commssioning of MISUBISHI,or Equivalent Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities as per specifications and drawings. The units shall be suitable for 230V±6%, or 415V±10%, 50 Hz. supply & complete with electrical controls & panels. The cost of indoor unit shall include the cost of wire with plug top (assuming wire (3X2.5Sqmm) length of 8 to 10 Meters as per drawing), including SITC of Fire retardant non porous double layer flexible canvass connection between eachindoor unit and duct as per approved drawings and specifications. Cassette type indoor unit
Supplying, installation and testing of Hi Wall type Indoor unit as per detail given below of MITSUBISHI OR EQUIVALENT APPROVED MAKE complete in all respects. 2TR Hi wall Type Split A/C
Supply, erection and commsioning of Corded Remotes with for Indoor Aircondioner units complete in all respects
Supply, erection and commsioning of Joints of different sizes inrefrigerant Copper piping work as per site requirement complete in all respects .
Supplying, installation, testing and commissioning of following sizes of refrigerant copper piping work (Mandev/Max Flow/ Total Line/ RajcoCopper Piping ) with 19/13mm thick closed cell elastomeric nitrile rubber tubular insulation (A-Flex/K-flex/ Superlon Insulation) between each set of indoor and outdoor units as per specifications duly painted with protective ultra violet paint complete as required. All piping works inside the class room shall be duly supported with MS hangers and clamps complete in all respects.
a) 44.5 mm outer dia (insulation 19mm)
c) 34.93mm outer dia (insulation 19mm)
d) 28.6mm outer dia (insulation 19mm)
e) 22.2mm outer dia (insulation 19mm)
f) 19.1mm outer dia (insulation 13mm)
g) 15.9mm outer dia (insulation 13mm)
i) 12.7mm outer dia (insulation 13mm)
j) 9.5mm outer dia (insulation 13mm)
k) 6.4mm outer dia (insulation 13mm)
Supply and installation of cable tray of following sizes including horizontal and vertical bends, cross member duly supported with suitable hangers and supports complete as required. complete in all respects. a) 150mm (wide) x 50mm(depth) x 1.6mm (thick)
Providing and fixing UPVC drain piping complete with fittings, insulated with 6 mm thick closed cell nitrile rubber insulation duly suported with suports as per specifications and requirement. a) 32 mm dia
Supply, Installation, Testing and Commissioning of control cum transmission wiring of 2 core x 1.50 sq mm copper wire in suitable PVC conduits between indoor & outdoor units to central remote controllers & for connections between indoor unit to outdoor unit
Supplying and laying Remote Controller wire ( core 0.75 mm) from indoor unit to remote , complete in all respects
Supplying and Charging of Gas R-410 in the above said unit (system with R-410A) and circuit omplete in all respects.
Providing and fixing of MS Outdoor stand with frame as per manufacturer of ACs,complete in all respected as directed by E-in E.
ACE Builders and Engineers
NIkhil Jain Govt. Contractors
IKA FURNITURE
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .