Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹39.0 L+₹54,046 (1.40%)Rejected-Finance | L2 | Rejected-Finance Not being L1 bidder | |
| 3 | L3₹39.5 L+₹1.0 L (2.63%)Rejected-Finance | L3 | Rejected-Finance Not being L1 bidder | |
| 4 | L4₹39.9 L+₹1.4 L (3.64%)Rejected-Finance | L4 | Rejected-Finance Not being L1 bidder | |
| 5 | L5₹42.9 L+₹4.4 L (11.5%)Rejected-Finance | L5 | Rejected-Finance Not being L1 bidder |
Tender Value
₹47.2 L
EMD Value
₹94,500
Closing Date
6 Dec 2023, 6:00 pmClosed
GARRISON ENGINEER SOUTH UDHAMPUR
GE SOUTH UDHAMPUR
SPECIAL REPAIR TO BLDG NO NP 157 OF APS AT HQNC UNDER GE SOUTH UDHAMPUR
2023_MES_627519_1
GE/S(U)- /2023-24
Open Tender
Civil Works
Works
240 days
GE SOUTH UDHAMPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹94,500
3 Feb 2024
8 Nov 2023
7 Dec 2023
8 Nov 2023
6 Dec 2023
22 Nov 2023
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sqm each and removing to store complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but n.exc 4 sqm each and removing complete all as specified and as directed.
Taking down cement plaster of any descreption on brick/stone walls or concrete surfaces including racking out joints, hacking for key scrubbing down with water etc on walls and ceiling, complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed.
Dismantling wall and ceiling boards of any description and thickness including cover fillets, complete all as specified and as directed
75 mm thick PCC 1:4:8, type D-2 by using 40 mm graded crushed stone aggregate as in sub base floor complete all as specified and as directed.
Glazed Coloured Ceramic tiles in vertical surface 300x600x7mm thick laid over 10 mm thick rendering/backig coat in CM 1:4, set and joint in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.
Digital glossy finished double charged Vitrified tiles light Shade 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
Digital glossy finished double charged Vitrified tiles light Shade of 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exc 1.0 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
Digital glossy finished double charged Vitrified tiles light Shade 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in vertical surfaces as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick screed bed in CM 1:4 complete all as specified and as directed.
Wall cladding colooured tiles (stone series) in vertical surface 300x600x7mm thick or size as approved by Engr in Charge laid over 10 mm thick rendering/backig coat in CM 1:4, set and joint in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.
Machine cut Kota stone slab flooring 18-20mm thick over cement screed base 15 mm thick in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed 10mm thick in CM 1:4, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Dura stone heavy duty vitrified tiles of size n exc 0.36 Sqm of 8-10mm thick as in floors set and jointed in neat cement slurry and pointed in white cement to match the surface including screed bed in CM 1:6 complete all as specified and as directed.
Solid PVC wall lining consisting of 5mm thick plain colour printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.
Pre-Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws including dismantling of old AC sheet complete all as specified and as directed.
Pre-Painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws including dismantling of old AC sheets complete all as specified and as directed.
4mm thick Cement fibre board (designer ceiling) of size 600mm x 600mm panel conforming to IS 14862 type B category three including GI frame work with size of grid 605mm x 605mm including all accessories and GI suspensions, the fibre sheet should be fire resistant, water resistant, termite resistant, environment friendly & 100% asbestos free complete all as specified and as directed.
Factory made uPVC white/coloured Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-in Charge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Factory made uPVC white/coloured Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi?chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made
8mm Toughned glass (Etching design on glass as approved by Engr in Charge) as in windows, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and as directed.
12mm Toughned glass(etching desgin on glass as approved by Engr in Charge) as in hinged doors, partitions, automatic doors and similar work including cutting to shape, drilling holes required including all accessories like 18" SS handle, floor machine, locking system and all connected accessoried etc complete all as specified and as directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
10-12 mm thick gypsum boards seemess false ceiling including sunk or raised moulding or cop design as approved, moisture resistant, including GI hanging wires & frames with intermediate, perimeter channel ceiling channel, along nuts and bolts connecting plates gypsum boards, dry wall screws soffits cleats, ceiling section, rawel plugs fixtures and screws and applying two coats of emulsion paint over a coat primer on exposed surface complete all as specified and directed by Engr-in-Charge. Note : (a) Design of ceiling board as approved by Engr-in-Charge. (b) GI grid/hanging system shall be of the same make as of false ceiling manufacturer.
Venetian blinds of Horizontal or vertical type using 100mm wide fabric blinds of approved colour/ shade and pattern including operating arrangement such as roller or chord/ thread, counter weight, connecting chain etc., and necessary fittings complete all as specified and as directed.
Granite stone 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking sweeping cleaning & washing down with water to remove dust etc incl removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00 kg/Sqm and applying bituminous primer on roof surfaces @ 0.40 ltr/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm and provide modified polymeric five layered APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polythylene film. Min wt of memebrane will be 3.5 kg/sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm blinded with fine sand in dry condition @ 0.5 kg/sqm all as specified and directed.
Brick work with sub class 'B' bricks exc 6m mean radius straight or curved on plan built in cement mortar 1:6 including demolition of old brick/stone masonry complete all as specified and as directed.
PCC 1:2:4 Type B-1 using 20 mm graded crushed stone aggregate in surface channels and drains complete all as specified and as directed.
Cement concrete 1:2:4 type B-1 (using 20 mm gradded crushed stone aggregate) use in coping, gola, hold fast and similar work including naccesary form work complete all as specified and as directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed.
Rendering 15 mm thick on brick or concrete surfaces of walls in CM (1:4) including finishing the surfaces fair and even without using extra cement complete all as specified and as directed.
Rendering 10mm thick on brick or concrete surfaces of walls in CM (1:6) including finishing the surfaces fair and even without using extra cement complete all as specified and as directed.
Rendering 5mm thick in cement plaster 1:3 on fair faces of brick work or concrete surfaces as on ceiling complete all as specified and as directed.
1000 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I and PTMT ball valve 20mm dia including taking down of old tank and removing from site complete all as specified and as directed.
S & F in repair of gun metal gate valve, painted finish, with forged brass spindle and iron wheel head, screwed both ends for iron pipe of size 20mm bore complete all as specified.
110 mm PVC (SWR) pipes single socket in any length with rubber ring joints fixed to wall complete all as specified and as directed.
110 mm PVC (SWR) bends any redius with access door complete all as specified and as directed.
110 mm PVC (SWR) branch piece, (singal T) equal or unequal with access door complete all as specified and as directed.
Applying 1 mm thick layer of wall putty on walls to give uniform surface, surface scrubed with emery paper and make surface good and clean complete all as specified and as directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed.
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power/ LED Light fittings) complete fitting such as switch, sockets, ceiling rose, pendants socket any type, rectangular board terminal boxes etc and making good disturbed surfaces of walls floors and ceiling keeping the LED lights in safe custody complete all as specified and as directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and as directed.
Taking down Old/ Unserviceable MCB DBs TPN / Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and as directed.
Disconnecting and taking down un serviceable light fittings of any description/ capacity complete all as specified and as directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with Modular sunken boxes & PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly as specified.Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish. Make:Havells/polycab/Finolex
All as per srl item No 49 but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 49 but for 3 pin 6 Amps socket outlet on the same board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed..
All as per Srl item No 49 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
S&F for modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with inner/outer plate complete all as specified and as directed.
S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with inner/outer plate complete all as specified and as directed.
S&F for modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC , with outer/inner cover complete all as specified and as directed.
S&F for modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC , flush type with outer/inner cover complete all as specified and as directed.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block complete all as specified and as directed.
S&F single pole and neutral enclosure surface mounted 240 voltswith 2 pin and earth plug and socket with one single pole MCB 20 Amps with indicator of complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 22W, 230V,AC decorative box type warm white colour with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F in replacement 36W (2 x 2) LED Ceiling/recess light panel for recess mounting warm white colour which provides soft-light and glare free symmetrical illumination complete all as specified and as directed.
Supply and fixing LED luminaire 15 watt, 220 V AC recess mounted downlighter type with high efficiency PC diffuser soft light and symmentrical illumination complete with driver, holders & LED lamp warm white suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F Sheet metal enclosure double door type for MCCB TPN DB upto 125 Amps, 4 way vertical type 415 volts with 400 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
S & F replacement MCCB Three Pole & Neutral capacity of 100 amps 415 volts rupturing capacity 16 KA complete all as specified and as directed.
S&F Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 08 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
S & F in replacement MCB single pole 240 volt any rating from 10 to 40 amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB single pole and neutral 240 volt any rating from 63 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 2x6 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead including taking down old sub main wire complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 2x10 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead including taking down old sub main wire complete all as specified and as directed.
Taking down ceiling fan/Exhaust fans (C/F of any size/make), cleaning its dust particles oiling,greasing,one coat of synthetic enamel white spray painting with blade ,reassemble the same along with all fittings and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring all as specified and as directed by Engr-in-Charge. Note :- (i) The spares like condensor, ball bearing, cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/damage deemed to be replaced and make the ceiling fans functional. No extra payments will be done on this account.
Taking down ceiling fan/Exhaust fans (C/F of any size/make), cleaning its dust particles oiling,greasing,one coat of synthetic enamel white spray painting with blade ,reassemble the same along with all fittings and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring all as specified and as directed by Engr-in-Charge. Note :- (i) The spares like condensor, ball bearing, cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/damage deemed to be replaced and make the ceiling fans functional. No extra payments will be done on this account.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers along with all electrical wire connection complete all as specified and as directed.
Supply and fix ceiling fan, AC single Phase. 230V of size 1200mm sweep with, blades, and frame along with all electrical wire connection complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x6.3 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized steel earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC 1:2:4 type B-1using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore main board complete all as shown in electrical plate No 5 connected to main control board all as specified and testing on completion. Note: Excavation earthwork charcoal PCC pit is covered under this item including taking out existing earth plate etc.Note: if earth resistance of earthing is not found (2 to 5 Ω) satisfactory if will be redone by the contractor on his risk and cost.
Supply and fix Wall fan, AC single Phase. 230V of size 450mm sweep with, blades, and frame along with all electrical wire connection complete all as specified and as directed.
Material & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 25 Sqmm x 3.5 core size all as specified including taking down old cable.Note : Earth work and other connected work shall be measured & paid sperately.
Material & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 4 Sqmm x 2 core size all as specified including taking down old cable.Note : Earth work and other connected work shall be measured & paid sperately.
Excavation in trenches and exceeding 1.5m wide and not exc 1.5m in depth in hard/dense soil and getting out complete all as specified and as directed.
Returing, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete complete all as specified and as directed.
M & L Dry sand for sand cushioning to under ground cable 8 cms thick before laying the cable before and 15 cms thick after laying & streching the cable in trenches, including hand punning and consolidating c complete all as specified and as directed. Note : for payment purpose punned thickness shall be measured
M&L Bricks sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and as directed.
Supply and fixing GI tubing light grade 40 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles complete all as specified and as directed.
M/S SUSHEEL KUMAR Govt. CONTRACTOR
s l sharma and sons
vmd traders
khajuria builders
jyoti parkash sharma
M/s LAL DAYAL CONSTRUCTION CO
SINGH CONST CO
m/s sushila devi
KALSOTRA CONSTRUCTION CO
VIRINDER SINGH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .