Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.0 LAccepted-AOC 208 2ND FLOOR MANISH CHAMBERS PREMISES CO OP SOCIETY SONAWALA CROSS ROAD ABOVE GOREGAON POST OFFICE GOREGAON EAST MUMBAI 400 063 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | 1 | Accepted-AOC Conforms the BOQ and L1 bidder | |
| 2 | 2₹11.0 L+₹4.0 L (56.9%)Rejected-AOC 7 1 KARUNANIDHI NAGAR SOWRIPALAYAM SOWRIPALAYAM COIMBATORE TAMIL NADU 641028 | COIMBATORE | TAMIL NADU | 641028 | 2 | Rejected-AOC Conforms the BOQ and L2 bidder | |
| 3 | 3₹11.2 L+₹4.2 L (59.7%)Rejected-AOC | 3 | Rejected-AOC Conforms the BOQ and L3 bidder | |
| 4 | Rejected-Technical 23 KULATHANGARAI STREET KULATHANGARAI STREET UTHIRAMERUR KANCHIPURAM TAMIL NADU 603406 | KANCHIPURAM | TAMIL NADU | 603406 | - | Rejected-Technical Not having the supply history of same equipment to Government Engineering colleges of TamilNadu | |
| 5 | Rejected-Technical 1301 13 BVR EK OPP INDER RESIDENCY HOTEL NR WESTOND HOTEL ELLISBRIDGE AHMEDABAD GUJARAT 380006 | AHMADABAD | GUJARAT | 380006 | - | Rejected-Technical Not having authorised service centre in TamilNadu and does not performed Live Demonstration for the same equipment in the previous tender |
Tender Value
Refer Docs
Closing Date
6 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Principal
TPGIT, Vellore-632002
Purchase of one number of Carbonation Chamber to carrying out research activities in civil department
2021_DoTE_198900_1
TPGIT/VELLORE/CIVIL/8A/A3/2020
Open Tender
Laboratory and scientific equipment
Item Rate
30 days
TPGIT
Prequalification requirements for the bidders attached
3 documents required · 3 mandatory
₹0
Exempted
16 Aug 2021
26 Feb 2021
8 Mar 2021
26 Feb 2021
6 Mar 2021
26 Feb 2021
90 days
Amount
CARBONATION CHAMBER
These Chambers are double wall PUF insulated modular panel. • Exterior executed in CRCA epoxy powder coated • Interior executed in Stainless Steel SS 304 • The door shall be made of 80mm thick PUF insulated panel clad with SS 304 inner & CRCA epoxy powder coated on outer, flash type fitted with glass viewing window, imported Cam hinges, lock, and door closer. The door is sealed with the silicon gasket to prevent the leakage. • Lockable & movable PU wheels for easy movement. The use of the most up to date PLC with HMI fully programmable 2 loop PID Controller, ASENSE / NDIR CO2 Detector and Controller with corrosive free MS powder coated exterior to enhance any test facility. PLC with HMI: Provides Precise Temperature, Relative Humidity and CO2 Maintain Uniform and Accurate Environment, Timer, Alarm, Auto-Tuning and Auto Start Stop Function. Shall have feature to run in real time or elapsed time. Control system shall have audio/audiovisual warning/alarm when set temperature/RH/CO2 is below or above the set values. Total no of output: 23 channels. Alert Unexpected Interruption of Electrical Power or Unauthorised change, 4 digit password lock. Data logger with LCD display window capable to store non volatile data memory up to 5000 readings with audit trail facility complies 21 CFR Part 11, change over to stand by system automatically as per schedule or on detecting fault with current system Temperature & Humidity overshoot and under shoot protection. Mobile Alarm system, Door Access system, setting reset, Graph, SMS, Email alert, etc., in built PC port for connectivity for base operation for data management. Protection of UPS system in built with the controller for safe and uninterrupted functioning. Removable SS perforated or rod trays (Qty: 2 nos) of suitable size are provided, are adjustable and slide out for easy clean up. Load bearing capacity 50 kg/per tray. Number of samples loading tray: 2 Weight of concrete sample that can be loaded per tray: 50 kg and total 100 kg. Internal Dimension : 60W x 60D x 60H (cms) Minimum Capacity : 200 Liters Temperature range : +50C to +500C with a incremental range of 0.1 Humidity Range : 30 % RH to 95% RH, Co2Range 0-10% by volume with CO2 NDIR sensors & regulators directly operated from PLC (fully programmable) Alarm : Audio Message Calling / Visual alarms. Power Supply : 230 VACS, +/-10 %, 50 Hz. Filled Co2Cylinder to be supplied by the supplier
Leading Edge Lab Equipments
Sofeel Marketing and Technical Services Pvt. Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .