| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC Quoting Lowest rate | |
| 2 | L2₹8.9 L+₹23,471 (2.71%)Rejected-Finance NICHUPATY BOLPUR P WEST BENGAL BIRBHUM PIN 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L2 | Rejected-Finance Quoting Higher Rate | |
| 3 | L3₹9.4 L+₹72,041 (8.33%)Rejected-Finance 121004 | L3 | Rejected-Finance Quoting Higher Rate |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
20 Mar 2019, 3:00 pmClosed
Superintending Enginee
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Construction of new office building for Chief Mining Officer at Asansol during 2017-2018 in a District of Paschim Bardhaman- SITC of 62.5 KVA DG Set
2019_WBPWD_217960_1
WBPWD/SEWEC/AED /NIQ-183/2018-19
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Asansol
Please refer Tender documents.
4 documents required · 4 mandatory
₹18,000
Yes
Office of the Superintending Engineer, Western El
12 Mar 2020
20 Feb 2019
25 Mar 2019
20 Feb 2019
20 Mar 2019
26 Feb 2019
20 Feb 2019 - 25 Feb 2019
25 Feb 2019
Amount
Supply , delivery at site on foundation , commissioning of 62.5 -KVA, 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-II approved Engin & Acoustic Enclosure having following specifications :-
ENGINE
Make : Cummins(Jakson)/Greaves/Kirloskar/Ashok Leyland
Engine Type : 4 Stroke Diesel Engine
Rated Output : 80 BHP or Higher
Duty : PRIME
Cooling : Water cooled with radiator
Cylinder : 4
Aspiration : Turbo Charged
Type of Governer : Electronic
Fuel Tank Capacity : Minimum capacity 150 Ltrs.
Fuel Consumption at 75% rated Load with Radiator or Fan : 12 Ltr./ Hr. or Less
Fuel Consumption at 100% rated Load with Radiator or Fan : 16 Ltr./ Hr. or Less
Overload Capacity : 10% overload for one hour for every 12 hours continious running at full load or better
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator
Exhaust Silencer : Residential Type
Starting system : 12V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning
ALTERNATOR
Make: Stamford/Crompton Greaves /Kirloskar/ Ashok Ley Power
Rating : 415 V., 3Ph. 50 Hz., 62.5 KVA, 1500 rpm
Type : Brushless, self excited and self regulated
Insulation : Class H
Protection : screen-protected drip proof with Min.IP-23 degree of protection
Voltage Regulation (max) : ±1%
Winding connection : Star with Neutral
Total Distortion factor : Less than 3%
Total Harmonic distortion in output waveform : < 5%
AMF PANEL
Cubical type floor mounted AMF panel made from 16 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 62.5 KVA DG set having following specification/features.
i) 125A 36KA MCCB with O/L, S/C, E/F protection and microprocessor based protection release , U/V release etc. - 2Sets
ii) In Built By-Pass switch for rated capacity
iii) On -delay timer for load change over
iv) On-delay timer for engine shut off
v) Engine On-Off switch (Push button type)
vii) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.
viii) Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'.
x) Microprocessor based relay with composite meter for digital display of following.
Generator voltage/AC Mains voltage.
Generator Current in all phases
Frequency
Power Factor
Energy
Indication for alternator supply
Running time indications number of hours of operation and service intervals, service due indications
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
ACOUSTIC ENCLOSURE
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustict enclosure must be certified as per CPCB-II norms.
BASE FRAME
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duty etc.
(ii) All materials, equipments & accessories must conform to relavent IS /IEC specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer.
(iii) Nacessary manufacturer's test certificate for Desiel Engin, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(iv) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competant Authority (As per CPCB-II).
(v) Circuit Diagram for AMF Panel must be submited from the Manufacturer/OEM.
(vi) The entire set must be warranted atleast 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier.
Part: B-- Installation of DG set
Supply, transporation & pouring of HSD Oil.
Supply, transporation & pouring of Mobil.
S & F exhaust pipe of 150 mm. dia MS black pipe (Thickness 4 mm) including connection with the existing silencer attached with the fexible coupler and S&F flange, nuts, bolts & washers etc. & necessary fixing materials etc. as required from DG set to nearest building (Vertical Run) with suitable high temperature painting.
S&F exhaust pipe of 100 mm. black pipe (thickness 4 mm.) including S&F flange, nuts, bolts & washers etc. as required from the nearest building wall to top of the building roof. (Horizontal / Vertical run) with suitable high temperature painting.
Making insulation by 2" glass wool including netting arrangement and mvfired with aluminum clading as per direction of the EIC.
a) 150 mm. dia exhaust pipe.
b) 100 mm dia exhaust pipe
c) Residential type silenser pipe
S&F rain protection canopy.
S& delivery of 200 Itrs. Capacity heavy gauge PVC sheet barrel.
Supply & delivery of best quality oil hand pump with 1" dia PVC flexible pipe (12ft. Approx)
Earthing with 50 mm dia(ISI medium) GI pipe in morrum soil as per GS
Excavation of morrum soil for installation of earth electrode and filling & ramming as per GS
Supply & fixing 25 x 6 mm. MS flat. for earth continuty from earth pit to DG set
Supply & fixing black PVC heat shrink sleeve for covering the 25 x 6 mm. GI flat.
Supply & laying 1 x 16 sq. mm. single core flexible copper wire(Make-Havells/KEI/Polycab/Finolex) in suitable size PVC pipe (reinforced) on wall / floor from neutral earth bus to DG set neutral point including both side socketing.
S&F compression type PVC gland for 40 mm dia reinforced pipe.
S&F 2 Kg capacity Gas pressure (ABC/DCP) fire extinguisher on wall by suitable size of iron bracket (Make - Fire shield)
S&F 9 ltr. Capacity round fire bucket with iron hook and duly filled up by sand.
S & F EI danger board, (size : 20 cm. x 30 cm.)
Providing CC Platform for installation of TOWER with dimension of CC foundation is 1 mtr x 1 mtr X 2.5 mtr depth = 2.5 cu.mtr after necessary excavation of earth work with Supply and delivery of all raw material i.e. stone chips, sand and cement and the height of platform 0.3 mtr from ground level with 3mm thick neatly finished cement plaster all round as per GS
S & F MS angle frame of 65x65x8 mm thick (upto the height of 1.5 mtr) and 50x50x6mm thick ( upto the height of 2.5 mtr) for TOWER structure for holding the 150mm dia exhaust pipe and upto the height of 4 mtr from ground level including necessary nuts & bolts as per direction of EIC and necessary paintaing as per GS
Hiring charges for scaffolding by bamboo, coir rope by square type arrangement for smooth working and lifting of MS black pipe for vertical installation including dismantling after completion of work.
Cutting RCC/cemented floor by special tools & tackles very carefully without any damaging and removing the shifted rubbish & leveling up and restoring the surface as per direction of EIC.
Part: C- El work
Supply & laying of 1.1 KV gr 4 core 50 sq. mm. XLPE/Ar. Al. conductor cable (Make-Havells/Polycab/KEI)as to G.S.
a) Laying in UG trench.
b) Laying through floor/wall
Supply & laying of 1.1 KV gr 4 core 25 sq. mm. XLPE/Ar. Al. conductor cable (Make-Havells/Polycab/KEI) as to G.S.
a) Laying in UG trench.
b) Laying through floor/wall
Supplying and fixing compression type gland complete and finishing the end of following cable as per GS
a) 4 core 50 sq.mm.
b) 4 core25 sq mm.
S & F 500v 8way VTPN (IP43 protection ) in sheet steel enclosure with double metal door (Make-Legrand/ABB/Siemens) complete with tinned copper brass neutral bar, earth bar, din rail etc. Suitable for SP/TP out going incorporating the following ratings of MCBs including fixed the DB on Iron Frame On wall/ flushed the DB inside wall as per site conditions including mending good the damages to building works and necy. Earthling attachment as per GS a) Incoming - 125amp 4pole MCCB-1no (Make-Legrand/ABB/Siemens) b) Outgoing - 63amp TPMCB -05 no. (Make-Legrand/ABB/Siemens) 32amp SPMCB-09 no (Make-Legrand/ABB/Siemens)
S/F of 415V 100A off load changeover switch (Make-Legrand/ABB/Siemens) with both side cable entry box on flat iron frame on wall as per GS
S/F 2" dia Gl pipe for cable protection(ISI-M)
NARAYAN CHANDRA DAS
GHOSH ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .